Brian F. Kraus
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Brian F. Kraus has a total of 239 co-authors. Here are the top co-authors by number of shared publications:
- Lan Gao
Princeton Plasma Physics Laboratory, Princeton University 1 , Princeton, New Jersey 08543
17 shared publications - Kenneth W Hill
Princeton Plasma Physics Laboratory
16 shared publications - Novimir Antoniuk Pablant
Princeton Plasma Physics Laboratory
11 shared publications - Manfred Bitter
Princeton Plasma Physics Laboratory, Princeton University 2 , Princeton, New Jersey 08540
9 shared publications M. Bitter
Princeton Plasma Physics Laboratory, Princeton University, Princeton, New Jersey 08543, USA
8 shared publications- Marilyn B. Schneider
Lawrence Livermore National Laboratory , Livermore, California 94550
8 shared publications
Latest Publications
- Open Access
- 26 October 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
Platform for high repetition rate proton stopping power measurements in Warm Dense Matter
We present a high-repetition-rate experimental platform for proton stopping-power measurements in warm dense matter in a regime where the projectile velocity approaches the electron thermal velocity and theoretical predictions remain highly uncertain. The platform combines laser-driven proton generation via target normal sheath acceleration with a compact magnetic energy selector to produce quasi-monoenergetic proton beams in the 0.3–0.6 MeV range with energy bandwidths of tens of keV and sub-nanosecond duration. Warm dense matter is generated by femtosecond laser heating of thin carbon foils and characterized using streaked optical pyrometry and x-ray pinhole grating spectroscopy, supported by radiation-hydrodynamic simulations. We further investigate the present limitations of the approach, including uncertainties in sample conditions, finite proton bunch duration, and proton scattering, and discuss pathways toward improved measurements. The results demonstrate a versatile and scalable approach for systematic, high-statistics studies of ion stopping power in warm dense matter relevant to inertial confinement fusion and charged-particle transport in high-energy-density plasmas.
- 26 October 2026
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
Open AccessPlatform for high repetition rate proton stopping power measurements in Warm Dense Matter
We present a high-repetition-rate experimental platform for proton stopping-power measurements in warm dense matter in a regime where the projectile velocity approaches the electron thermal velocity and theoretical predictions remain highly uncertain. The platform combines laser-driven proton generation via target normal sheath acceleration with a compact magnetic energy selector to produce quasi-monoenergetic proton beams in the 0.3–0.6 MeV range with energy bandwidths of tens of keV and sub-nanosecond duration. Warm dense matter is generated by femtosecond laser heating of thin carbon foils and characterized using streaked optical pyrometry and x-ray pinhole grating spectroscopy, supported by radiation-hydrodynamic simulations. We further investigate the present limitations of the approach, including uncertainties in sample conditions, finite proton bunch duration, and proton scattering, and discuss pathways toward improved measurements. The results demonstrate a versatile and scalable approach for systematic, high-statistics studies of ion stopping power in warm dense matter relevant to inertial confinement fusion and charged-particle transport in high-energy-density plasmas.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
A proposal for a 1D-imaging broadband x-ray crystal spectrometer enabled by a sagittally focusing x-ray mirror
Measurements of x-ray absorption/opacity in ionized plasmas at the National Ignition Facility in experiments with high neutron yields require large detector standoff distances, motivating advances in opacity spectrometer design. We propose a spectrometer in which x rays first reflect from a sagittally focusing mirror with a variable-radius sagittal profile. The mirror sets the sagittal imaging condition so that, after subsequent reflection from a meridionally bent crystal, the x rays form a sagittally focused spectrum at the detector plane. The crystal provides spectral dispersion in the meridional direction, while sagittal focusing by the mirror enables 1D imaging of an emitting (or backlit) object. The basic characteristics of the spectrometer are described analytically. The imaging performance of a selected high-magnification design is studied numerically via ray tracing. We show that a large spectral range (Emax − Emin)/E0 ≃ 1/2, high spectral resolving power E/ΔE ≃ 1000, high magnification, M ≃ 10, and 1D spatial resolution of better than 100 μm can be achieved simultaneously.
- 1 October 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (10)
A proposal for a 1D-imaging broadband x-ray crystal spectrometer enabled by a sagittally focusing x-ray mirror
Measurements of x-ray absorption/opacity in ionized plasmas at the National Ignition Facility in experiments with high neutron yields require large detector standoff distances, motivating advances in opacity spectrometer design. We propose a spectrometer in which x rays first reflect from a sagittally focusing mirror with a variable-radius sagittal profile. The mirror sets the sagittal imaging condition so that, after subsequent reflection from a meridionally bent crystal, the x rays form a sagittally focused spectrum at the detector plane. The crystal provides spectral dispersion in the meridional direction, while sagittal focusing by the mirror enables 1D imaging of an emitting (or backlit) object. The basic characteristics of the spectrometer are described analytically. The imaging performance of a selected high-magnification design is studied numerically via ray tracing. We show that a large spectral range (Emax − Emin)/E0 ≃ 1/2, high spectral resolving power E/ΔE ≃ 1000, high magnification, M ≃ 10, and 1D spatial resolution of better than 100 μm can be achieved simultaneously.
- Open Access
- 1 November 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (11)
Toward electron temperature profiles in hot-dense plasmas from x-ray spectral ensembles
High repetition rate laser systems enable new strategies for diagnosing plasma behavior with large datasets. Here, we define an ensemble technique that relies on randomized targeting of x-ray tracer micro-stripes. On each shot, a high-intensity laser pulse is focused on a solid target with Ti tracer stripes embedded in an Al foil, randomly targeting a micro-stripe, a portion of a stripe, or a gap between stripes. High-resolution, time-integrated x-ray spectrometers capture line emission from the portion of the micro-stripe that is heated to sufficiently high electron temperatures. Accumulation of many such cases is used to construct ensemble distributions of x-ray line intensities that encompass all relative offsets of the laser focus to the micro-stripe centers. Synthetic intensity distributions are likewise generated using collisional-radiative modeling. Bayesian fitting of modeled to measured intensity distributions establishes the most likely radial temperature profiles, enabling comparison to hydrodynamic models and calling into question the cylindrical symmetry of these micro-stripe-embedded systems. Ensemble techniques have significant potential for high-energy-density plasma diagnostics, especially with the advent of high repetition rate experiments.
- 1 November 2024
- Published by AIP Publishing in Physics of Plasmas
- Vol. 31 (11)
Open AccessToward electron temperature profiles in hot-dense plasmas from x-ray spectral ensembles
High repetition rate laser systems enable new strategies for diagnosing plasma behavior with large datasets. Here, we define an ensemble technique that relies on randomized targeting of x-ray tracer micro-stripes. On each shot, a high-intensity laser pulse is focused on a solid target with Ti tracer stripes embedded in an Al foil, randomly targeting a micro-stripe, a portion of a stripe, or a gap between stripes. High-resolution, time-integrated x-ray spectrometers capture line emission from the portion of the micro-stripe that is heated to sufficiently high electron temperatures. Accumulation of many such cases is used to construct ensemble distributions of x-ray line intensities that encompass all relative offsets of the laser focus to the micro-stripe centers. Synthetic intensity distributions are likewise generated using collisional-radiative modeling. Bayesian fitting of modeled to measured intensity distributions establishes the most likely radial temperature profiles, enabling comparison to hydrodynamic models and calling into question the cylindrical symmetry of these micro-stripe-embedded systems. Ensemble techniques have significant potential for high-energy-density plasma diagnostics, especially with the advent of high repetition rate experiments.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)
High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. In this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
Measurements of K-edge and L-edge extended x-ray absorption fine structure at the national ignition facility (invited)
High-energy-density laser facilities and advances in dynamic compression techniques have expanded access to material states in the Terapascal regime relevant to inertial confinement fusion, planetary science, and geophysics. However, experimentally determining the material temperature in these extreme conditions has remained a difficult challenge. Extended X-ray Absorption Fine Structure (EXAFS), referring to the modulations in x-ray absorption above an absorption edge from photoelectrons’ interactions with neighboring atoms, has proven to be a versatile and robust technique for probing material temperature and density for mid-to-high Z elements under dynamic compression. The current platform at the National Ignition Facility has developed six configurations for EXAFS measurements between 7 and 18 keV for different absorption edges (Fe K, Co K, Cu K, Ta L3, Pb L3, and Zr K) using a curved-crystal spectrometer and a bright, continuum foil x-ray source. In this work, we describe the platform geometry, x-ray source performance, spectrometer resolution and throughput, design considerations, and data in ambient and dynamic-compression conditions.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis
X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. A Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.
- 1 October 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (10)
In-situ relative calibration of Bragg crystals with Monte Carlo line ratio analysis
X-ray line emission spectra can thoroughly characterize hot plasmas, especially when line shapes and ratios convey distinct aspects of plasma conditions. However, the high spectral resolution required for observing line shapes is often at odds with the large bandwidth required to observe many line ratios across a wide spectral range. One strategy to obtain high spectral resolution over a wide bandwidth is to use multiple crystals with calibrated reflectivity so that line intensities across different crystals can be compared. Here, we explore the use of a low-resolution, wide-bandwidth mica survey spectrometer to infer relative reflectivity of two high-resolution, narrow-bandwidth quartz crystals. A Monte Carlo error analysis determines comparable x-ray line ratios measured from both spectrometers, resulting in an in situ calibration factor and associated uncertainty for the relative reflectivity of the high-resolution crystals.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers
X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. In this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα1 and Kα2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers
X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. In this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα1 and Kα2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Learning from each other: Cross-cutting diagnostic development activities between magnetic and inertial confinement fusion (invited)
Inertial Confinement Fusion and Magnetic Confinement Fusion (ICF and MCF) follow different paths toward goals that are largely common. In this paper, the claim is made that progress can be accelerated by learning from each other across the two fields. Examples of successful cross-community knowledge transfer are presented that highlight the gains from working together, specifically in the areas of high-resolution x-ray imaging spectroscopy and neutron spectrometry. Opportunities for near- and mid-term collaboration are identified, including in chemical vapor deposition diamond detector technology, using gamma rays to monitor fusion gain, handling neutron-induced backgrounds, developing radiation hard technology, and collecting fundamental supporting data needed for diagnostic analysis. Fusion research is rapidly moving into the igniting and burning regimes, posing new opportunities and challenges for ICF and MCF diagnostics. This includes new physics to probe, such as alpha heating; increasingly harsher environmental conditions; and (in the slightly longer term) the need for new plant monitoring diagnostics. Substantial overlap is expected in all of these emerging areas, where joint development across the two subfields as well as between public and private researchers can be expected to speed up advancement for all.
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessLearning from each other: Cross-cutting diagnostic development activities between magnetic and inertial confinement fusion (invited)
Inertial Confinement Fusion and Magnetic Confinement Fusion (ICF and MCF) follow different paths toward goals that are largely common. In this paper, the claim is made that progress can be accelerated by learning from each other across the two fields. Examples of successful cross-community knowledge transfer are presented that highlight the gains from working together, specifically in the areas of high-resolution x-ray imaging spectroscopy and neutron spectrometry. Opportunities for near- and mid-term collaboration are identified, including in chemical vapor deposition diamond detector technology, using gamma rays to monitor fusion gain, handling neutron-induced backgrounds, developing radiation hard technology, and collecting fundamental supporting data needed for diagnostic analysis. Fusion research is rapidly moving into the igniting and burning regimes, posing new opportunities and challenges for ICF and MCF diagnostics. This includes new physics to probe, such as alpha heating; increasingly harsher environmental conditions; and (in the slightly longer term) the need for new plant monitoring diagnostics. Substantial overlap is expected in all of these emerging areas, where joint development across the two subfields as well as between public and private researchers can be expected to speed up advancement for all.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Statistical data analysis of x-ray spectroscopy data enabled by neural network accelerated Bayesian inference
Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. We present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Statistical data analysis of x-ray spectroscopy data enabled by neural network accelerated Bayesian inference
Bayesian inference applied to x-ray spectroscopy data analysis enables uncertainty quantification necessary to rigorously test theoretical models. However, when comparing to data, detailed atomic physics and radiation transfer calculations of x-ray emission from non-uniform plasma conditions are typically too slow to be performed in line with statistical sampling methods, such as Markov Chain Monte Carlo sampling. Furthermore, differences in transition energies and x-ray opacities often make direct comparisons between simulated and measured spectra unreliable. We present a spectral decomposition method that allows for corrections to line positions and bound–bound opacities to best fit experimental data, with the goal of providing quantitative feedback to improve the underlying theoretical models and guide future experiments. In this work, we use a neural network (NN) surrogate model to replace spectral calculations of isobaric hot-spots created in Kr-doped implosions at the National Ignition Facility. The NN was trained on calculations of x-ray spectra using an isobaric hot-spot model post-processed with Cretin, a multi-species atomic kinetics and radiation code. The speedup provided by the NN model to generate x-ray emission spectra enables statistical analysis of parameterized models with sufficient detail to accurately represent the physical system and extract the plasma parameters of interest.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing
A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing
A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe44+, Xe47+, and Xe51+, based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.
- 2 December 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (23) , 235001
Ablating Ion Velocity Distributions in Short-Pulse-Heated Solids via X-Ray Doppler Shifts
Solids ablate under laser irradiation, but experiments have not previously characterized the initiation of this process at ultrarelativistic laser intensities. We present first measurements of bulk ion velocity distributions as ablation begins, captured as a function of depth via Doppler-shifted x-ray line emission from two viewing angles. Bayesian analysis indicates that bulk ions are either nearly stationary or flowing outward at the plasma sound speed. The measurements quantitatively constrain the laser-plasma ablation mechanism, suggesting that a steplike electrostatic potential structure drives solid disassembly.
- 2 December 2022
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 129 (23) , 235001
Ablating Ion Velocity Distributions in Short-Pulse-Heated Solids via X-Ray Doppler Shifts
Solids ablate under laser irradiation, but experiments have not previously characterized the initiation of this process at ultrarelativistic laser intensities. We present first measurements of bulk ion velocity distributions as ablation begins, captured as a function of depth via Doppler-shifted x-ray line emission from two viewing angles. Bayesian analysis indicates that bulk ions are either nearly stationary or flowing outward at the plasma sound speed. The measurements quantitatively constrain the laser-plasma ablation mechanism, suggesting that a steplike electrostatic potential structure drives solid disassembly.