X-ray sources for in situ wavelength calibration of x-ray imaging crystal spectrometers
- 1 September 2024
- journal article
- research article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Abstract
X-ray sources for a range of wavelengths are being considered for in situ calibration of X-ray Imaging Crystal Spectrometers (XICSs) and for monitoring line shifts due to changes in the crystal temperature, which can vary during experimental operation over a day [A. Ince-Cushman et al., Rev. Sci. Instrum. 79, 10E302 (2008), L. Delgado-Aparicio et al., Plasma Phys. Control. Fusion 55, 125011 (2013)]. Such crystal temperature dependent shifts, if not accounted for, could be erroneously interpreted as Doppler shifts leading to errors in plasma flow-velocity measurements. The x-ray sources encompass characteristic x-ray lines falling within the wavelength range of 0.9–4.0 Å, relevant for the XICSs on present and future fusion devices. Several technological challenges associated with the development of x-ray sources for in situ calibration are identified and are being addressed in the design of multiple x-ray tubes, which will be installed inside the spectrometer housing of the XICS for the JT-60SA tokamak. These x-ray sources will be especially useful for in situ calibration between plasma discharges. In this paper, laboratory experiments are described that were conducted with a Cu x-ray source, a heated quartz (102) crystal, and a pixelated Pilatus detector to measure the temperature dependent shifts of the Cu Kα1 and Kα2 lines at 1.5405 and 1.5443 Å, respectively, and to evaluate the 2d-lattice constant for the Bragg reflecting crystal planes as a function of temperature, which, in the case of in situ wavelength calibration, would have to be used for numerical analysis of the x-ray spectra from the plasma.Keywords
Funding Information
- U.S. Department of Energy (DE-AC02-09CH11466)
This publication has 22 references indexed in Scilit:
- Design of tangential x-ray crystal spectrometer for Aditya-U tokamakReview of Scientific Instruments, 2018
- Development of wavelength calibration techniques for high-resolution x-ray imaging crystal spectrometers on the EAST tokamakReview of Scientific Instruments, 2018
- In situ wavelength calibration system for the X-ray Imaging Crystal Spectrometer (XICS) on W7-XReview of Scientific Instruments, 2018
- Experimentally determining the relative efficiency of spherically bent germanium and quartz crystalsReview of Scientific Instruments, 2016
- Measurement of helium-like and hydrogen-like argon spectra using double-crystal X-ray spectrometers on EASTReview of Scientific Instruments, 2016
- Rest-wavelength fiducials for the ITER core imaging x-ray spectrometerReview of Scientific Instruments, 2012
- The first experimental results from x-ray imaging crystal spectrometer for KSTARReview of Scientific Instruments, 2010
- Spatially resolved high resolution x-ray spectroscopy for magnetically confined fusion plasmas (invited)Review of Scientific Instruments, 2008
- A spatially resolving x-ray crystal spectrometer for measurement of ion-temperature and rotation-velocity profiles on the Alcator C-Mod tokamakReview of Scientific Instruments, 2008
- Charge exchange recombination spectroscopy as a plasma diagnostic tool (invited)Review of Scientific Instruments, 1985