Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Caro Franck has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Eric Achten

    From the Department of Medical Physics, Ghent University, Profetuinstraat 86, 9000 Ghent, Belgium (C.F., K.B.); and Departments of Radiology (P.S., E.A.) and Medical Oncology (L.L.), Ghent University Hospital, Ghent, Belgium

    3 shared publications
  • Klaus Bacher

    From the Department of Medical Physics, Ghent University, Profetuinstraat 86, 9000 Ghent, Belgium (C.F., K.B.); and Departments of Radiology (P.S., E.A.) and Medical Oncology (L.L.), Ghent University Hospital, Ghent, Belgium

    3 shared publications
  • Peter Smeets

    From the Department of Medical Physics, Ghent University, Profetuinstraat 86, 9000 Ghent, Belgium (C.F., K.B.); and Departments of Radiology (P.S., E.A.) and Medical Oncology (L.L.), Ghent University Hospital, Ghent, Belgium

    3 shared publications
  • An De Crop

    Department of Nuclear Medicine, AZ Delta, Roeselare, Belgium

    2 shared publications
  • Annelies Mondelaers

    Department of Radiology, Antwerp University Hospital (UZA), 2650 Edegem, Belgium

    1 shared publication
  • Annemiek Snoeckx

    Antwerp University Hospital

    1 shared publication

Latest Publications

  • Open Access

    A systematic review and meta-analysis on the radiation dose of computed tomography in hybrid nuclear medicine imaging

    by Gwenny Verfaillie, Caro Franck, An De Crop, Laurence Beels, Yves D’asseler, Klaus Bacher

    Background: While diagnostic reference levels (DRLs) are well-established for the radiopharmaceutical part, published DRLs for the CT component of positron emission tomography/computed tomography (PET/CT) and single photon emission computed tomography/computed tomography (SPECT/CT) are limited. This systematic review and meta-analysis provides an overview of the different objectives of CT in hybrid imaging and summarizes reported CT dose values for the most common PET/CT and SPECT/CT examinations. Also, an overview of already proposed national DRLs is given. Methods: A systematic literature search was performed to identify original articles reporting CT dose index volume (CTDIvol), dose-length product (DLP) and/or national DRLs for the most frequently performed PET/CT and/or SPECT/CT examinations. Data were grouped according to the clinical objective: diagnostic (D-CT), anatomical localisation (AL-CT) or attenuation correction (AC-CT) CT. Random-effects meta-analyses were conducted. Results: Twenty-seven articles were identified of which twelve reported national DRLs. For brain and tumour PET/CT imaging, CTDIvol and DLP values were higher for a D-CT (brain: 26.7 mGy, 483 mGy cm; tumour: 8.8 mGy, 697 mGy cm) than for an AC/AL-CT (brain: 11.3 mGy, 216 mGy cm; tumour: 4.3 mGy, 419 mGy cm). Similar conclusions were found for bone and parathyroid SPECT/CT studies: D-CT (bone: 6.5 mGy, 339 mGy cm; parathyroid: 15.1 mGy, 347 mGy cm) results in higher doses than AL-CT (bone: 3.8 mGy, 156 mGy cm; parathyroid: 4.9 mGy, 166 mGy cm). For cardiac (AC-CT), mIBG/octreotide, thyroid and post-thyroid ablation (AC/AL-CT) SPECT/CT pooled mean CTDIvol (DLP) values were 1.8 mGy (33 mGy cm), 4.6 mGy (208 mGy cm), 3.1 mGy (105 mGy cm) and 4.6 mGy (145 mGy cm), respectively. For all examinations, high variability in nuclear medicine practice was observed. Conclusion: The large variation in CT dose values and national DRLs highlights the need for optimisation in hybrid imaging and justifies the clinical implementation for nuclear medicine specific DRLs.


  • Open Access

    Selective Angiographic Flat Detector Computer Tomography Blood Volume Imaging in Pre-Operative Vascular Mapping and Embolization of Hypervascular Intracranial Tumors—Preliminary Clinical Experience

    by Thijs van der Zijden, Annelies Mondelaers, Caro Franck, Maurits Voormolen, Tomas Menovsky

    Pre-operative embolization of hypervascular intracranial tumors can be performed to reduce bleeding complications during resection. Accurate vascular mapping of the tumor is necessary for both the correct indication setting for embolization and for the evaluation of the performed embolization. We prospectively examined the role of whole brain and selective parenchymal blood volume (PBV) flat detector computer tomography perfusion (FD CTP) imaging in pre-operative angiographic mapping and embolization of patients with hypervascular intracranial tumors. Whole brain FD CTP imaging with a contrast injection from the aortic root and selective contrast injection in the dural feeding arteries was performed in five patients referred for tumor resection. Regional relative PBV values were obtained pre- and post-embolization. Total tumor volumes with selective external carotid artery (ECA) supply volumes and post-embolization devascularized tumor volumes were determined as well. In all patients, including four females and one male, with a mean age of 54.2 years (range 44–64 years), the PBV scans were performed without adverse events. The average ECA supply was 54% (range 31.5–91%). The mean embolized tumor volume was 56.5% (range 25–94%). Relative PBV values decreased from 5.75 ± 1.55 before embolization to 2.43 ± 1.70 post-embolization. In one patient, embolization was not performed because of being considered not beneficial for the resection. Angiographic FD CTP imaging of the brain tumor allows 3D identification and quantification of individual tumor feeder arteries. Furthermore, the technique enables monitoring of the efficacy of pre-operative endovascular tumor embolization.


  • Open Access

    Lesion measurement on a combined “all-in-one” window for chest CT: effect on intra- and interobserver variability

    by Annemiek Snoeckx, Jeroen Cant, Caro Franck, Elisa Luyckx, Ken Carpentier, Simon Nicolay, Astrid Van Hoyweghen, Maarten J. Spinhoven, Pieter Vuylsteke, Paul M. Parizel

    Purpose: A newly developed image processing technique fuses conventional windows into a single ‘All-In-One’ (AIO) window. This study aims to evaluate variability of CT measurement of lesions in thoracic oncology patients on this novel AIO-window. Methods: Six radiologists with different levels of expertise measured 368 lesions of various size, origin and sharpness. All lesions were measured twice on the AIO-window and twice on the conventional window settings. Intraclass correlation coefficients and Bland-Altman plots were used to assess intra- and interobserver variability. Results: Overall intra-observer agreement for lesion diameters on the AIO-window and conventional window settings was 0.986 (95% Confidence interval (CI): 0.983–0.989) and 0.991 (95% CI 0.989–0.993) respectively. For interobserver agreement this was 0.982 (95% CI 0.979–0.985) (AIO) and 0.979 (95% CI 0.957–0.982) (conventional). For both the AIO and conventional windows, intra- and interobserver agreement were dependent on size, sharpness and reader experience. Measurement variability decreased with increasing lesion size. Regarding sharpness, inter- and intra-observer agreement ranged from 0.986–0.989 (AIO) and 0.985–0.992 (conventional) for well-defined lesions and from 0.978–0.983 (AIO) and 0.974–0.991 (conventional) for ill-defined lesions. Conclusions: Lesion diameters were consistently smaller on the AIO-window compared to conventional window settings. Overall intra- and interobserver variability rates were similar for the AIO-window and conventional window settings. We conclude that the AIO-window offers a reliable and reproducible alternative for measurement of thoracic lesions.


  • Estimating the Patient-specific Dose to the Thyroid and Breasts and Overall Risk in Chest CT When Using Organ-based Tube Current Modulation

    by Caro Franck, Peter Smeets, Lore Lapeire, Eric Achten, Klaus Bacher

    The potential benefit of organ-based tube current modulation to the female breast in chest CT is overestimated because of a limited reduced tube current zone; despite a 9% dose reduction to the female breast, posterior organs will absorb up to 26% more radiation, resulting in no reduction in radiation-induced malignancies. Purpose To assess the potential dose reduction to the thyroid and breasts in chest computed tomography (CT) with organ-based tube current modulation (OBTCM). Materials and Methods In this retrospective study (from January 2015 to December 2016), the location of the breasts with respect to the reduced tube current zone was determined. With Monte Carlo simulations, patient-specific dose distributions of chest CT scans were calculated for 50 female patients (mean age, 53.7 years ± 17.5; range, 20–80 years). The potential dose reduction with OBTCM was assessed. In addition, simulations of clinical OBTCM scans were made for 17 of the 50 female patients (mean age, 43.8 years ± 17.1; range, 20–69 years). Posterior organs in the field of view were analyzed and lifetime attributable risk (LAR) of cancer incidence and mortality was estimated. Image quality between standard CT and OBTCM scans was compared. Results No women had all breast tissue within the reduced tube current zone. Dose reductions of 18% in the thyr...


  • Evaluation of automatic image quality assessment in chest CT – A human cadaver study

    by Caro Franck, An De Crop, Bieke De Roo, Peter Smeets, Merel Vergauwen, Tom Dewaele, Mathias Van Borsel, Eric Achten, Tom Van Hoof, Klaus Bacher


  • INFLUENCE OF LOCALIZER AND SCAN DIRECTION ON THE DOSE-REDUCING EFFECT OF AUTOMATIC TUBE CURRENT MODULATION IN COMPUTED TOMOGRAPHY

    by C. Franck, K. Bacher

    The purpose of this study was to investigate the influence of the localizer and scan direction on the dose-reducing efficacy of the automatic tube current modulation (ATCM) in computed tomography (CT). Craniocaudal and caudocranial chest CT scans, based on anterior–posterior (AP), posterior–anterior (PA), lateral (LAT) or dual AP/LAT localizers, of an anthropomorphic phantom containing thermoluminescent dosimeters (TLDs), were made on three Siemens systems. TLD readings were converted to lung and thyroid doses. A second dose estimation was performed based on Monte Carlo simulations. In addition, the ATCM behaviour of GE and Toshiba was evaluated based on AP, PA and LAT localizers. Compared with AP, tube currents of PA and AP/LAT scans were on average 20 % higher and 40 % lower, respectively, for the Siemens systems. Consequently, thyroid and lung doses increased with 60 % with a PA instead of an AP/LAT scan, with significant differences in image noise. Moreover, the thyroid dose halves by taking the scan in caudocranial direction. Noise values were not significantly different when changing scan direction.


  • The role of Size-Specific Dose Estimate (SSDE) in patient-specific organ dose and cancer risk estimation in paediatric chest and abdominopelvic CT examinations

    by Caro Franck, Charlot Vandevoorde, Ingeborg Goethals, Peter Smeets, Eric Achten, Koenraad Verstraete, Hubert Thierens, Klaus Bacher

    Objectives To develop a clinically applicable method to estimate patient-specific organ and blood doses and lifetime attributable risks (LAR) from paediatric torso CT examinations. Methods Individualized voxel models were created from full-body CT data of 10 paediatric patients (2–18 years). Patient-specific dose distributions of chest and abdominopelvic CT scans were simulated using Monte Carlo methods. Blood dose was calculated as a weighted sum of simulated organ doses. LAR of cancer incidence and mortality were estimated, according to BEIR-VII. A second simulation and blood dose calculation was performed using only the thoracic and abdominopelvic region of the original voxel models. For each simulation, the size-specific dose estimate (SSDE) was calculated. Results SSDE showed a significant strong linear correlation with organ dose (r > 0.8) and blood dose (r > 0.9) and LAR (r > 0.9). No significant differences were found between blood dose calculations with the full-body voxel models and the thoracic or abdominopelvic models. Conclusion Even though clinical CT images mostly do not cover the whole body of the patient, they can be used as a voxel model for blood dose calculation. In addition, SSDE can estimate patient-specific organ and blood doses and LAR in paediatric torso CT examinations. Key Points • Blood dose can be simulated using the patient’s clinical CT images. • SSDE estimates patient-specific organ/blood dose and LAR in paediatric CAP CT-examinations. • SSDE makes on-the-spot dose and LAR estimations possible in routine clinical practice.