Feng-Yi Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Feng-Yi Lin has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Kuei Chen
Research Center for Energy Technology and Strategy, National Cheng Kung University, Tainan 70101, Taiwan
4 shared publications - Ta-Hui Lin
Department of Mechanical Engineering, National Cheng Kung University, Tainan 70101, Taiwan
4 shared publications - Chung-Chih Cheng
Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4 Chung Hsing Rd., Chutung, Hsinchu 310401, Taiwan
3 shared publications - Pei-Yu Yu
Green Energy and Environment Research Laboratories, Industrial Technology Research Institute, 195, Sec. 4 Chung Hsing Rd., Chutung, Hsinchu 310401, Taiwan
3 shared publications - Tzu-Ching Su
Green Energy and Environment Research Laboratories (GEL), Industrial Technology Research Institute (ITRI), Hsinchu 310, Taiwan
3 shared publications - Wei-Chieh Hu
Research Center for Energy Technology and Strategy, National Cheng Kung University, Tainan 70101, Taiwan
3 shared publications
Latest Publications
- Open Access
The Influence of Electrochromic Film on Indoor Environmental Quality
This study was conducted at SPINLab. The full-scale experiments were performed using two experimental spaces of identical specifications to investigate the effects of electrochromic film (OG + ECON or OG + ECOFF) on indoor environment and air conditioning electricity consumption in buildings with different orientations (East and West). The electricity-saving effects are more pronounced on the building’s west-facing side than on its east-facing side. For the east-facing side, the average electricity savings for OG + ECON and OG + ECOFF were 4.5%, and 5.1%, respectively. For the west-facing side, the average electricity savings increased to 9.2% and 9.4% for OG + ECON and OG + ECOFF. The research results on thermal comfort indicate (PMV) that applying electrochromic film (OG + ECON or OG + ECOFF) significantly improved indoor thermal comfort compared to using clear glass (OG) alone. The visual comfort analysis results indicate that the opaque (OG + ECOFF) and transparent (OG + ECON) states of electrochromic film could reduce daylight glare probability (DGP) values. However, due to the light-scattering properties of the liquid crystal droplets, the OG + ECOFF and OG + ECON states of the electrochromic film increased DGP values in 26.5% and 41.5% of the cases, respectively, when sunlight directly entered the interior.
Open AccessThe Influence of Electrochromic Film on Indoor Environmental Quality
This study was conducted at SPINLab. The full-scale experiments were performed using two experimental spaces of identical specifications to investigate the effects of electrochromic film (OG + ECON or OG + ECOFF) on indoor environment and air conditioning electricity consumption in buildings with different orientations (East and West). The electricity-saving effects are more pronounced on the building’s west-facing side than on its east-facing side. For the east-facing side, the average electricity savings for OG + ECON and OG + ECOFF were 4.5%, and 5.1%, respectively. For the west-facing side, the average electricity savings increased to 9.2% and 9.4% for OG + ECON and OG + ECOFF. The research results on thermal comfort indicate (PMV) that applying electrochromic film (OG + ECON or OG + ECOFF) significantly improved indoor thermal comfort compared to using clear glass (OG) alone. The visual comfort analysis results indicate that the opaque (OG + ECOFF) and transparent (OG + ECON) states of electrochromic film could reduce daylight glare probability (DGP) values. However, due to the light-scattering properties of the liquid crystal droplets, the OG + ECOFF and OG + ECON states of the electrochromic film increased DGP values in 26.5% and 41.5% of the cases, respectively, when sunlight directly entered the interior.
- Open Access
Evaluation of the Effects of Window Films on the Indoor Environment and Air-Conditioning Electricity Consumption of Buildings
The objective of this study was to evaluate the effects of window films on indoor environmental conditions and electricity consumption of air conditioning. The research focused on the performance of different window films (HAG, RG), taking into account variations from different building orientations. The findings of this research indicated that building orientation could significantly influence the duration of direct sunlight entering the interior, with the areas closer to the glass being more susceptible to the effects of outdoor temperature and solar radiation. The clear glass with heat-absorbing film (HAG) and reflective film (RG) both reduced the indoor temperature and indoor illuminance while increasing indoor comfort. The RG could accumulate less heat on the glass surface compared with the HAG. The glass temperature of the RG will be lower than the HAG. The electricity-saving ratios of the HAG were 1.4%, 1.9%, 1.4%, and 1.2%, respectively, when facing the east, south, west, and northwest orientations compared with the clear glass (OG). The electricity-saving ratios of the RG were 3%, 4.2%, 4.2%, and 10.3%, respectively.
Open AccessEvaluation of the Effects of Window Films on the Indoor Environment and Air-Conditioning Electricity Consumption of Buildings
The objective of this study was to evaluate the effects of window films on indoor environmental conditions and electricity consumption of air conditioning. The research focused on the performance of different window films (HAG, RG), taking into account variations from different building orientations. The findings of this research indicated that building orientation could significantly influence the duration of direct sunlight entering the interior, with the areas closer to the glass being more susceptible to the effects of outdoor temperature and solar radiation. The clear glass with heat-absorbing film (HAG) and reflective film (RG) both reduced the indoor temperature and indoor illuminance while increasing indoor comfort. The RG could accumulate less heat on the glass surface compared with the HAG. The glass temperature of the RG will be lower than the HAG. The electricity-saving ratios of the HAG were 1.4%, 1.9%, 1.4%, and 1.2%, respectively, when facing the east, south, west, and northwest orientations compared with the clear glass (OG). The electricity-saving ratios of the RG were 3%, 4.2%, 4.2%, and 10.3%, respectively.
- Open Access
Influence of Roller Blinds Shading Strategy on West and South Facing Buildings
This study investigates the impact of roller blinds as an energy-saving strategy in a subtropical climate. Lighting control experiments were performed on west-facing and south-facing windows in the Subtropical Performance-Testbed for Innovative eNergy Research in Buildings Laboratory (SPINLab). This study accepts sunlight below 8000 lux and requires the indoor lighting of at least a reading of 500 lux. For the west-facing window experiment, the curtain energy-saving strategy implemented in this study resulted in 10% less energy consumption for air-conditioning and saved 90% of the lighting power consumption of the west facing window building. For the south-facing window experiment, we found that sunlight can fully supplement the lighting without adjusting the roller blinds because the window opening is different from the sunlight direction. In addition, the significant heat flux difference between the west-facing and south-facing windows experiments is also reflected in the energy consumption of the air conditioners.
Open AccessInfluence of Roller Blinds Shading Strategy on West and South Facing Buildings
This study investigates the impact of roller blinds as an energy-saving strategy in a subtropical climate. Lighting control experiments were performed on west-facing and south-facing windows in the Subtropical Performance-Testbed for Innovative eNergy Research in Buildings Laboratory (SPINLab). This study accepts sunlight below 8000 lux and requires the indoor lighting of at least a reading of 500 lux. For the west-facing window experiment, the curtain energy-saving strategy implemented in this study resulted in 10% less energy consumption for air-conditioning and saved 90% of the lighting power consumption of the west facing window building. For the south-facing window experiment, we found that sunlight can fully supplement the lighting without adjusting the roller blinds because the window opening is different from the sunlight direction. In addition, the significant heat flux difference between the west-facing and south-facing windows experiments is also reflected in the energy consumption of the air conditioners.
- Open Access
A Study on Control Strategy for Air Conditioning of Western Exposed Rooms in Subtropical Region
Recently, energy saving has been a major issue in all aspects. In buildings, air conditioning is one major part of power consumption. In this study, we examined the effect of an intermittent control strategy for air conditioning on energy saving in western-exposed rooms under subtropical weather conditions. The strategy applied periodic deactivation and reactivation to the air conditioners. Room temperatures, power consumption, and readings from sensors of air conditioners of two identical rooms were monitored and analyzed. For indoor temperatures, we found that the deactivation of the air conditioner for 15 min resulted in temperature peaks that were 4 to 5 °C higher than the control room. The reactivation of the air conditioner was able to cool down the room within 10 min based on the built-in sensor. However, due to the location and resolution of the sensor, the overall temperature from the four temperature and humidity sensors was still higher than the target setting, which may cause thermal discomfort. For power consumption, the strategy led to power peaks while reactivating, but the summation was 2.9% lower.
Open AccessA Study on Control Strategy for Air Conditioning of Western Exposed Rooms in Subtropical Region
Recently, energy saving has been a major issue in all aspects. In buildings, air conditioning is one major part of power consumption. In this study, we examined the effect of an intermittent control strategy for air conditioning on energy saving in western-exposed rooms under subtropical weather conditions. The strategy applied periodic deactivation and reactivation to the air conditioners. Room temperatures, power consumption, and readings from sensors of air conditioners of two identical rooms were monitored and analyzed. For indoor temperatures, we found that the deactivation of the air conditioner for 15 min resulted in temperature peaks that were 4 to 5 °C higher than the control room. The reactivation of the air conditioner was able to cool down the room within 10 min based on the built-in sensor. However, due to the location and resolution of the sensor, the overall temperature from the four temperature and humidity sensors was still higher than the target setting, which may cause thermal discomfort. For power consumption, the strategy led to power peaks while reactivating, but the summation was 2.9% lower.
- Open Access
- 19 January 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (2) , 960
Application of a High-Density Temperature Measurement System for the Management of the Kaohsiung House Project
In Taiwan, the daytime temperature usually exceeds 37 °C in summer, and the increase in air-conditioning usage has led to higher energy demand, which brings a heavy burden to power plants. The Kaohsiung House Project, undertaken by the city government, encourages the installation of greening facilities in buildings, such as photovoltaic (PV) panels on rooftops and vertical gardens on balconies, in order to preserve energy and reduce carbon emissions. In the present study, the urban heat island effect and temperature distribution within the city was examined through the establishment of 16 temperature measurement sites within a 7.5 km × 6 km area. A between-site temperature difference of 2 °C was observed between April and August. Areas with higher temperature are recommended to increase their green space ratio through the project. Moreover, relocating PV panels in low-temperature areas increased the overall generation efficiency by 0.8%. Through the analysis of the measured data, this study determined which areas were more appropriate for green space expansion, and which would best serve for green energy generation, all with the aim of improving external environmental comfort and maximizing carbon reduction. Recommendations regarding the implementation of subsequent policies were issued and they provide reference for implementation in other cities.
- 19 January 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (2) , 960
Open AccessApplication of a High-Density Temperature Measurement System for the Management of the Kaohsiung House Project
In Taiwan, the daytime temperature usually exceeds 37 °C in summer, and the increase in air-conditioning usage has led to higher energy demand, which brings a heavy burden to power plants. The Kaohsiung House Project, undertaken by the city government, encourages the installation of greening facilities in buildings, such as photovoltaic (PV) panels on rooftops and vertical gardens on balconies, in order to preserve energy and reduce carbon emissions. In the present study, the urban heat island effect and temperature distribution within the city was examined through the establishment of 16 temperature measurement sites within a 7.5 km × 6 km area. A between-site temperature difference of 2 °C was observed between April and August. Areas with higher temperature are recommended to increase their green space ratio through the project. Moreover, relocating PV panels in low-temperature areas increased the overall generation efficiency by 0.8%. Through the analysis of the measured data, this study determined which areas were more appropriate for green space expansion, and which would best serve for green energy generation, all with the aim of improving external environmental comfort and maximizing carbon reduction. Recommendations regarding the implementation of subsequent policies were issued and they provide reference for implementation in other cities.