    The Influence of Electrochromic Film on Indoor Environmental Quality

    by Kuan-Ting Yeh, Wei-Chieh Hu, Chun-Kuei Chen, Ta-Hui Lin, Feng-Yi Lin, Chung-Chih Cheng, Tzu-Ching Su, Pei-Yu Yu

    This study was conducted at SPINLab. The full-scale experiments were performed using two experimental spaces of identical specifications to investigate the effects of electrochromic film (OG + ECON or OG + ECOFF) on indoor environment and air conditioning electricity consumption in buildings with different orientations (East and West). The electricity-saving effects are more pronounced on the building’s west-facing side than on its east-facing side. For the east-facing side, the average electricity savings for OG + ECON and OG + ECOFF were 4.5%, and 5.1%, respectively. For the west-facing side, the average electricity savings increased to 9.2% and 9.4% for OG + ECON and OG + ECOFF. The research results on thermal comfort indicate (PMV) that applying electrochromic film (OG + ECON or OG + ECOFF) significantly improved indoor thermal comfort compared to using clear glass (OG) alone. The visual comfort analysis results indicate that the opaque (OG + ECOFF) and transparent (OG + ECON) states of electrochromic film could reduce daylight glare probability (DGP) values. However, due to the light-scattering properties of the liquid crystal droplets, the OG + ECOFF and OG + ECON states of the electrochromic film increased DGP values in 26.5% and 41.5% of the cases, respectively, when sunlight directly entered the interior.


  • Open Access

    Evaluation of the Effects of Window Films on the Indoor Environment and Air-Conditioning Electricity Consumption of Buildings

    by Hsing-Yun Huang, Wei-Chieh Hu, Chun-Kuei Chen, Ta-Hui Lin, Feng-Yi Lin, Chung-Chih Cheng, Tzu-Ching Su, Pei-Yu Yu

    The objective of this study was to evaluate the effects of window films on indoor environmental conditions and electricity consumption of air conditioning. The research focused on the performance of different window films (HAG, RG), taking into account variations from different building orientations. The findings of this research indicated that building orientation could significantly influence the duration of direct sunlight entering the interior, with the areas closer to the glass being more susceptible to the effects of outdoor temperature and solar radiation. The clear glass with heat-absorbing film (HAG) and reflective film (RG) both reduced the indoor temperature and indoor illuminance while increasing indoor comfort. The RG could accumulate less heat on the glass surface compared with the HAG. The glass temperature of the RG will be lower than the HAG. The electricity-saving ratios of the HAG were 1.4%, 1.9%, 1.4%, and 1.2%, respectively, when facing the east, south, west, and northwest orientations compared with the clear glass (OG). The electricity-saving ratios of the RG were 3%, 4.2%, 4.2%, and 10.3%, respectively.


  • Open Access

    A Study on Control Strategy for Air Conditioning of Western Exposed Rooms in Subtropical Region

    by Tzu-Yang Hu, Chun-Kuei Chen, Wei-Chieh Hu, Ta-Hui Lin, Feng-Yi Lin, Chung-Chih Cheng, Tzu-Ching Su, Pei-Yu Yu

    Recently, energy saving has been a major issue in all aspects. In buildings, air conditioning is one major part of power consumption. In this study, we examined the effect of an intermittent control strategy for air conditioning on energy saving in western-exposed rooms under subtropical weather conditions. The strategy applied periodic deactivation and reactivation to the air conditioners. Room temperatures, power consumption, and readings from sensors of air conditioners of two identical rooms were monitored and analyzed. For indoor temperatures, we found that the deactivation of the air conditioner for 15 min resulted in temperature peaks that were 4 to 5 °C higher than the control room. The reactivation of the air conditioner was able to cool down the room within 10 min based on the built-in sensor. However, due to the location and resolution of the sensor, the overall temperature from the four temperature and humidity sensors was still higher than the target setting, which may cause thermal discomfort. For power consumption, the strategy led to power peaks while reactivating, but the summation was 2.9% lower.