SUStephan Ulrich

Stephan Ulrich

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Stephan Ulrich has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Morphology and Photoelectrochemical Properties of Sputtered WO 3 :Mo Anodes

    by David Adner, Michael Arnold, Julia Hilbig, Ralf Bandorf, Arno Görne, A. Wouter Maijenburg, Marko Turek, Christian Hagendorf, Stephan Ulrich

    We present an investigation of sputtered WO 3 :Mo thin films as anodes for photoelectrochemical water splitting. The films were deposited by reactive sputtering from a W:Mo target ( w Mo = 10 at.%) on SnO 2 :F/glass with a systematic variation of the pressure p (0.40, 0.55, 0.70 Pa), the oxygen partial pressure p O2 (4–19 mPa), the substrate temperature T s (245, 280, 320 °C), the deposition rate r (0.6–7.8 nm min –1 ), and the thickness d (0.83–1.88 µm). For high T s , the layers consist of well‐defined crystals, whereas samples grown at a lower temperature show a high percentage of microcrystalline structures. The morphology correlates with the photocurrent density J , which is generally higher for crystalline layers. No correlations were found between J and p , p O2 , r , or d in the investigated parameter space. The highest measured J was 0.784 mA cm –2 at a potential of 1.23 V versus RHE.

  • Mixed metal oxides as optically-passive ion storage layers in electrochromic devices based on metallopolymers

    by Lukas Niklaus, Marco Schott, Jonas Subel, Stephan Ulrich, Daniel Reichert, Uwe Posset, Guinevere A. Giffin


  • Scale effects of the rheological properties of electrorheological suspensions

    by Holger Freyer, Andreas Breitfeld, Stephan Ulrich, Steffen Schneider, Rainer Bruns, Jens Wulfsberg

    The knowledge about the rheological behavior of electrorheological suspensions in all prevalent conditions is essential for the design process of applications. Of particular importance is the dependence of fluid viscosity on the electric field strength, the temperature, and the shear rate. Previous research has pointed out the difficulties in determining the relevant rheological parameters independent from the geometry and flow conditions. For example, experimental results obtained using a capillary rheometer are different from the results gained in flow channel experiments. Even the results from one flow channel could not easily be used to predict the performance of a channel with, for example, a different distance between the electrodes. Some possible effects such as wall slip, interactions of the particles with the surface of the electrodes, or scale effects based on the particle size distribution in relation to the dimension of the flow channel may complicate the determination of the rheological parameters. To investigate these effects, a flow channel test rig that allows systematic changes to the flow conditions was developed. The distance of the electrodes can continuously be changed from 0.02 to 1 mm with an apparent shear rate from 100 to 10,000 s−1. The electrodes can easily be replaced to determine the influence of surface structure. This article will first discuss the design of the flow channel followed by the experimental results obtained under different test conditions. The aim of this research is to gain insight into the scale effects of electrorheological suspensions in order to develop microfluidic applications.