WSWenjuan Sun

Wenjuan Sun

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wenjuan Sun has a total of 58 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • The realisation of fast X-ray computed tomography using a limited number of projection images for dimensional metrology

    by Wenjuan Sun, Stephan Chretien, Ander Biguri, Manuchehr Soleimani, Thomas Blumensath, Jessica Talbott


  • Open Access

    Effects of fast x-ray cone-beam tomographic measurement on dimensional metrology

    by Charalambos Rossides, Hossein Towsyfyan, Ander Biguri, Hans Deyhle, Reuben Lindroos, Mark Mavrogordato, Richard Boardman, Wenjuan Sun, Thomas Blumensath

    X-ray computed tomography (XCT) is increasingly used for dimensional metrology, where it can offer accurate measurements of internal features that are not accessible with other techniques. However, XCT scanning can be relatively slow, which often prevents routine uptake for many applications. This paper explores the feasibility of improving the speed of XCT measurements while maintaining the quality of the dimensional measurements derived from reconstructed volumes. In particular, we compare two approaches to fast XCT acquisition, the use of fewer XCT projections as well as the use of shortened x-ray exposure times for each projection. The study shows that the additional Poisson noise produced by reducing the exposure for each projection has significantly less impact on dimensional measurements compared to the artefacts associated with strategies that take fewer projection images, leading to about half the measurement error variability. Advanced reconstruction algorithms such as the conjugate gradient least squares method or total variation constrained approaches, are shown to allow further improvements in measurement speed, though this can come at the cost of increased measurement bias (e.g. 2.8% increase in relative error in one example) and variance (e.g. 25% in the same example).


  • 3D roughness standard for performance verification of topography instruments for additively-manufactured surface inspection

    by Christopher W Jones, Wenjuan Sun, Hal Boulter, Stephen Brown

    The unique complex topography of additively-manufactured surfaces—and the recent rapid evolution of instruments and techniques to measure them—limits trust in inspection data, in direct conflict with the requirements of application areas such as aerospace, where failure of a part can have serious safety consequences. Topography instrument manufacturers and end-users require measurement standards with a controlled reproduction of representative additively-manufactured surfaces to calibrate, performance-verify and intercompare instruments for inspection tasks, thereby improving confidence in measurement. The design of such a surface texture measurement standard is reported, optimised for optical areal topography-measuring instruments and compatible with x-ray computed tomography instruments. Machined from an additively-manufactured blank, the standard’s four sides represent increasing levels of post-processing from the as-deposited surface. Datum features on the measurement standard facilitate direct comparison between topography instruments. Integrated step features support the calibration of an instrument’s Z scale. Calibration of a prototype of the standard is reported; the prototype is matched to a typical aerospace Scalmalloy™ additive manufacturing process. The calibration is also a trial application of a large-area chromatic confocal microscope; this instrument appears capable of calibrating relatively rough measurement standards if required to do so. Reference Ra and S -parameter measurements and associated measurement uncertainties are presented, correlation between parameters noted, and choice and consequences of filter settings discussed.


  • Review of high energy x-ray computed tomography for non-destructive dimensional metrology of large metallic advanced manufactured components

    by Wenjuan Sun, Daniel R Symes, Ceri M Brenner, Michael Böhnel, Stephen Brown, Mark N Mavrogordato, Ian Sinclair, Michael Salamon

    Advanced manufacturing technologies, led by additive manufacturing, have undergone significant growth in recent years. These technologies enable engineers to design parts with reduced weight while maintaining structural and functional integrity. In particular, metal additive manufacturing parts are increasingly used in application areas such as aerospace, where a failure of a mission-critical part can have dire safety consequences. Therefore, the quality of these components is extremely important. A critical aspect of quality control is dimensional evaluation, where measurements provide quantitative results that are traceable to the standard unit of length, the metre. Dimensional measurements allow designers, manufacturers and users to check product conformity against engineering drawings and enable the same quality standard to be used across the supply chain nationally and internationally. However, there is a lack of development of measurement techniques that provide non-destructive dimensional measurements beyond common non-destructive evaluation focused on defect detection. X-ray computed tomography (XCT) technology has great potential to be used as a non-destructive dimensional evaluation technology. However, technology development is behind the demand and growth for advanced manufactured parts. Both the size and the value of advanced manufactured parts have grown significantly in recent years, leading to new requirements of dimensional measurement technologies. This paper is a cross-disciplinary review of state-of-the-art non-destructive dimensional measuring techniques relevant to advanced manufacturing of metallic parts at larger length scales, especially the use of high energy XCT with source energy of greater than 400 kV to address the need in measuring large advanced manufactured parts. Technologies considered as potential high energy x-ray generators include both conventional x-ray tubes, linear accelerators, and alternative technologies such as inverse Compton scattering sources, synchrotron sources and laser-driven plasma sources. Their technology advances and challenges are elaborated on. The paper also outlines the development of XCT for dimensional metrology and future needs.


  • Open Access

    Fast Hyperparameter Calibration of Sparsity Enforcing Penalties in Total Generalised Variation Penalised Reconstruction Methods for XCT Using a Planted Virtual Reference Image

    by Stéphane Chrétien, Camille Giampiccolo, Wenjuan Sun, Jessica Talbott

    The reconstruction problem in X-ray computed tomography (XCT) is notoriously difficult in the case where only a small number of measurements are made. Based on the recently discovered Compressed Sensing paradigm, many methods have been proposed in order to address the reconstruction problem by leveraging inherent sparsity of the object’s decompositions in various appropriate bases or dictionaries. In practice, reconstruction is usually achieved by incorporating weighted sparsity enforcing penalisation functionals into the least-squares objective of the associated optimisation problem. One such penalisation functional is the Total Variation (TV) norm, which has been successfully employed since the early days of Compressed Sensing. Total Generalised Variation (TGV) is a recent improvement of this approach. One of the main advantages of such penalisation based approaches is that the resulting optimisation problem is convex and as such, cannot be affected by the possible existence of spurious solutions. Using the TGV penalisation nevertheless comes with the drawback of having to tune the two hyperparameters governing the TGV semi-norms. In this short note, we provide a simple and efficient recipe for fast hyperparameters tuning, based on the simple idea of virtually planting a mock image into the model. The proposed trick potentially applies to all linear inverse problems under the assumption that relevant prior information is available about the sought for solution, whilst being very different from the Bayesian method.


  • Open Access

    FVM and XCT Measurement of Surface Texture of Additively Manufactured Parts

    by Weidong Liu, Xiao Chen, Wenhan Zeng, Wenjuan Sun, Xiangqian Jiang, Paul Scott, Shan Lou

    Focus variation microscopy (FVM) and X-ray computed tomography (XCT) are two popular technologies employed to measure the surface texture of additively manufactured components. The impacts of various influence factors of these two measurement techniques on surface texture measurement are investigated, respectively. A two-stage surface registration program is developed to allow the accurate comparison of surface topographies measured by two instruments at the same location on the surface. The associated surface texture parameters Sa, Sq, Ssk, and Sku are also compared. The results indicate XCT can capture re-entrant features, while FVM can capture more details. However, XCT measurement is limited in its resolution and FVM measurement is restricted by the line-of-sight constraint. The surface parameters of two measurement techniques are closer in the cases where surface texture of the parts is higher.


  • Open Access

    Ant Colony-Based Hyperparameter Optimisation in Total Variation Reconstruction in X-ray Computed Tomography

    by Manasavee Lohvithee, Wenjuan Sun, Stephane Chretien, Manuchehr Soleimani

    In this paper, a computer-aided training method for hyperparameter selection of limited data X-ray computed tomography (XCT) reconstruction was proposed. The proposed method employed the ant colony optimisation (ACO) approach to assist in hyperparameter selection for the adaptive-weighted projection-controlled steepest descent (AwPCSD) algorithm, which is a total-variation (TV) based regularisation algorithm. During the implementation, there was a colony of artificial ants that swarm through the AwPCSD algorithm. Each ant chose a set of hyperparameters required for its iterative CT reconstruction and the correlation coefficient (CC) score was given for reconstructed images compared to the reference image. A colony of ants in one generation left a pheromone through its chosen path representing a choice of hyperparameters. Higher score means stronger pheromones/probabilities to attract more ants in the next generations. At the end of the implementation, the hyperparameter configuration with the highest score was chosen as an optimal set of hyperparameters. In the experimental results section, the reconstruction using hyperparameters from the proposed method was compared with results from three other cases: the conjugate gradient least square (CGLS), the AwPCSD algorithm using the set of arbitrary hyperparameters and the cross-validation method.The experiments showed that the results from the proposed method were superior to those of the CGLS algorithm and the AwPCSD algorithm using the set of arbitrary hyperparameters. Although the results of the ACO algorithm were slightly inferior to those of the cross-validation method as measured by the quantitative metrics, the ACO algorithm was over 10 times faster than cross—Validation. The optimal set of hyperparameters from the proposed method was also robust against an increase of noise in the data and can be applicable to different imaging samples with similar context. The ACO approach in the proposed method was able to identify optimal values of hyperparameters for a dataset and, as a result, produced a good quality reconstructed image from limited number of projection data. The proposed method in this work successfully solves a problem of hyperparameters selection, which is a major challenge in an implementation of TV based reconstruction algorithms.


  • Open Access

    Establishing waveguide lines as primary standards for scattering parameter measurements at submillimetre wavelengths

    by Nick Ridler, S Johny, Martin Salter, Xiaobang Shang, Wenjuan Sun, Alan Wilson, Amrutha Susan Johny

    This paper presents a detailed assessment of two rectangular metallic waveguide lines in order that they can be used as primary standards to provide metrological traceability for electrical scattering parameter measurements at submillimetre wavelengths. The assessment comprises a series of dimensional measurements to determine the overall quality of the lines in terms of the waveguide aperture size and alignment. This is followed by electrical measurements to confirm the electrical behaviour of the lines. Finally, the lines are employed as standards to calibrate a vector network analyser which is used to measure devices to verify the performance of the lines as calibration standards, in operando. The waveguide size is WM-380, which operates from 500 GHz to 750 GHz.