Zhixiang Hua
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhixiang Hua has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Jin Yang
Department of Ophthalmology, Eye, Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People’s Republic of China
7 shared publications - Lei Cai
Department of Ophthalmology, Eye, Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
3 shared publications - Xiaoyan Han
Department of Ophthalmology and the Eye Institute, Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
3 shared publications - Baoxian Zhuo
Department of Ophthalmology, Eye, Ear, Nose, and Throat Hospital of Fudan University, Shanghai, People's Republic of China
2 shared publications - Dongmei Ma
Department of Ophthalmology and the Eye Institute, Eye and Ear, Nose, and Throat Hospital, Fudan University, Shanghai, China
2 shared publications - Jiying Shen
Department of Ophthalmology, Shanghai Heping Eye Hospital, Shanghai, China
2 shared publications
Latest Publications
- 16 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (12) , 1203-1209
Rotational stability of three toric intraocular lens platforms after cataract surgery: prospective multicenter randomized trial
Purpose: To compare the postoperative rotational stability of 3 toric intraocular lens (IOL) platforms and identify platform-specific biometric factors associated with rotation. Setting: 3 eye centers in China. Design: Prospective multicenter randomized controlled trial. Methods: A total of 256 eyes of 172 cataract patients with regular corneal astigmatism that completed 3 months of follow-up after phacoemulsification with implantation of TECNIS Toric II, Clareon Toric, or AT TORBI 709M were included. Participants were randomly assigned to one of the 3 toric IOL platforms. Baseline rotational alignment was defined at the end of surgery and compared with retroillumination images obtained at 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. Results: Absolute rotation changed most prominently within the first week and then progressively stabilized. Rotational stability was reached earlier in the ZCU and CNW0T groups, which plateaued at 1 week, whereas the AT TORBI 709M approached stability between 2 weeks and 1 month. Throughout follow-up, the AT TORBI 709M showed greater rotation than the CNW0T, whereas the ZCU demonstrated the least rotation. Significant rotation of ≥10 degrees occurred in 1.2%, 2.4%, and 12.2% of eyes, respectively. White-to-white distance was associated with greater rotation in the CNW0T and AT TORBI 709M groups, lens thickness was additionally associated with greater rotation in the AT TORBI 709M group, and no biometric factor reached significance in the ZCU group. Conclusions: Hydrophobic C-loop toric IOLs showed better early rotational stability than the hydrophilic plate-haptic toric IOL. Biometric correlates of rotation differed across platforms, supporting individualized toric IOL selection and postoperative monitoring.
- 16 July 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (12) , 1203-1209
Rotational stability of three toric intraocular lens platforms after cataract surgery: prospective multicenter randomized trial
Purpose: To compare the postoperative rotational stability of 3 toric intraocular lens (IOL) platforms and identify platform-specific biometric factors associated with rotation. Setting: 3 eye centers in China. Design: Prospective multicenter randomized controlled trial. Methods: A total of 256 eyes of 172 cataract patients with regular corneal astigmatism that completed 3 months of follow-up after phacoemulsification with implantation of TECNIS Toric II, Clareon Toric, or AT TORBI 709M were included. Participants were randomly assigned to one of the 3 toric IOL platforms. Baseline rotational alignment was defined at the end of surgery and compared with retroillumination images obtained at 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. Results: Absolute rotation changed most prominently within the first week and then progressively stabilized. Rotational stability was reached earlier in the ZCU and CNW0T groups, which plateaued at 1 week, whereas the AT TORBI 709M approached stability between 2 weeks and 1 month. Throughout follow-up, the AT TORBI 709M showed greater rotation than the CNW0T, whereas the ZCU demonstrated the least rotation. Significant rotation of ≥10 degrees occurred in 1.2%, 2.4%, and 12.2% of eyes, respectively. White-to-white distance was associated with greater rotation in the CNW0T and AT TORBI 709M groups, lens thickness was additionally associated with greater rotation in the AT TORBI 709M group, and no biometric factor reached significance in the ZCU group. Conclusions: Hydrophobic C-loop toric IOLs showed better early rotational stability than the hydrophilic plate-haptic toric IOL. Biometric correlates of rotation differed across platforms, supporting individualized toric IOL selection and postoperative monitoring.
- 1 June 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (6) , 594-601
Nomogram for predicting significant rotation after plate-haptic toric intraocular lens implantation in a Chinese population
Purpose: To identify independent risk factors associated with significant postoperative rotation (≥10 degrees) of plate-haptic toric intraocular lenses (IOLs) and to develop and externally validate a predictive nomogram. Setting: 2 independent eye centers in China. Design: Prospective observational study with a training cohort and an external validation cohort. Methods: 805 eyes from 805 cataract patients with regular corneal astigmatism (≥0.75 diopter) who underwent phacoemulsification and plate-haptic toric IOL implantation between August 2021 and December 2024 were included. Patients from 1 center formed the training cohort, while patients from the second center served as the external validation cohort. Least absolute shrinkage and selection operator regression followed by multivariate logistic regression was used to identify predictors of significant toric IOL rotation (≥10 degrees at 2 weeks postoperatively). A predictive nomogram was developed and validated through receiver operating characteristic analysis, calibration curve, and decision curve analysis (DCA). Results: Age (odds ratio [OR] = 1.04, P = .002), anterior chamber depth (ACD) (OR = 7.71, P < .001), lens thickness (LT) (OR = 5.13, P < .001), and white-to-white (WTW) (OR = 2.36, P = .002) were identified as independent predictors. The nomogram demonstrated good discriminative performance with an area under the curve of 0.809 in the training cohort and 0.848 in the validation cohort. Calibration and DCA analyses confirmed the accuracy and clinical utility of the model. Conclusions: A validated nomogram based on age, ACD, LT, and WTW provides a useful tool for individualized preoperative risk assessment of significant toric IOL rotation, aiding surgical decision-making.
- 1 June 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (6) , 594-601
Nomogram for predicting significant rotation after plate-haptic toric intraocular lens implantation in a Chinese population
Purpose: To identify independent risk factors associated with significant postoperative rotation (≥10 degrees) of plate-haptic toric intraocular lenses (IOLs) and to develop and externally validate a predictive nomogram. Setting: 2 independent eye centers in China. Design: Prospective observational study with a training cohort and an external validation cohort. Methods: 805 eyes from 805 cataract patients with regular corneal astigmatism (≥0.75 diopter) who underwent phacoemulsification and plate-haptic toric IOL implantation between August 2021 and December 2024 were included. Patients from 1 center formed the training cohort, while patients from the second center served as the external validation cohort. Least absolute shrinkage and selection operator regression followed by multivariate logistic regression was used to identify predictors of significant toric IOL rotation (≥10 degrees at 2 weeks postoperatively). A predictive nomogram was developed and validated through receiver operating characteristic analysis, calibration curve, and decision curve analysis (DCA). Results: Age (odds ratio [OR] = 1.04, P = .002), anterior chamber depth (ACD) (OR = 7.71, P < .001), lens thickness (LT) (OR = 5.13, P < .001), and white-to-white (WTW) (OR = 2.36, P = .002) were identified as independent predictors. The nomogram demonstrated good discriminative performance with an area under the curve of 0.809 in the training cohort and 0.848 in the validation cohort. Calibration and DCA analyses confirmed the accuracy and clinical utility of the model. Conclusions: A validated nomogram based on age, ACD, LT, and WTW provides a useful tool for individualized preoperative risk assessment of significant toric IOL rotation, aiding surgical decision-making.
- Open Access
- 9 May 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (19) , e42357
Cathepsins and age-related macular degeneration: A Mendelian randomization study unveiling causal relationships
Age-related macular degeneration (AMD) is a leading cause of vision impairment and blindness in older adults, profoundly affecting millions of individuals worldwide. Cathepsins are a crucial class of proteolytic enzymes that participates in multiple biological process. However, the role of cathepsins in AMD still remains unclear. This study aims to probe into the causal relationship between cathepsins and AMD using a 2-sample Mendelian randomization (MR). Instrumental variables associated with exposure (cathepsins) and the outcome (AMD) were sourced from published genome-wide association studies. To estimate the causal effects, methodologies such as inverse variance weighted, MR-Egger, and weighted median estimation (WM) were employed. Reverse MR and multivariate MR analyses were also performed. The elevated levels of cathepsin B significantly increased the risk of dry AMD, with an odds ratio (OR) of 1.068 (95% CI = 1.007–1.133) and a P -value of .029). Sensitivity analyses confirmed the robustness of these findings, with no evidence of heterogeneity or pleiotropy. Reverse MR analyses indicated that total AMD might elevate levels of cathepsin E (OR = 1.04, P = .029). Multivariate MR analysis showed significant associations between specific cathepsins and AMD subtypes, including cathepsin G and cathepsin O with significantly increasing risk. The study revealed a potential causal effect of cathepsin B on AMD, especially dry AMD. These findings provide potential therapeutic targets for AMD, and further research is needed to understand the underlying mechanisms.
- 9 May 2025
- Published by Wolters Kluwer Health in Medicine
- Vol. 104 (19) , e42357
Open AccessCathepsins and age-related macular degeneration: A Mendelian randomization study unveiling causal relationships
Age-related macular degeneration (AMD) is a leading cause of vision impairment and blindness in older adults, profoundly affecting millions of individuals worldwide. Cathepsins are a crucial class of proteolytic enzymes that participates in multiple biological process. However, the role of cathepsins in AMD still remains unclear. This study aims to probe into the causal relationship between cathepsins and AMD using a 2-sample Mendelian randomization (MR). Instrumental variables associated with exposure (cathepsins) and the outcome (AMD) were sourced from published genome-wide association studies. To estimate the causal effects, methodologies such as inverse variance weighted, MR-Egger, and weighted median estimation (WM) were employed. Reverse MR and multivariate MR analyses were also performed. The elevated levels of cathepsin B significantly increased the risk of dry AMD, with an odds ratio (OR) of 1.068 (95% CI = 1.007–1.133) and a P -value of .029). Sensitivity analyses confirmed the robustness of these findings, with no evidence of heterogeneity or pleiotropy. Reverse MR analyses indicated that total AMD might elevate levels of cathepsin E (OR = 1.04, P = .029). Multivariate MR analysis showed significant associations between specific cathepsins and AMD subtypes, including cathepsin G and cathepsin O with significantly increasing risk. The study revealed a potential causal effect of cathepsin B on AMD, especially dry AMD. These findings provide potential therapeutic targets for AMD, and further research is needed to understand the underlying mechanisms.
- Open Access
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (1) , 31-39
Rotational stability of plate-haptic toric intraocular lenses implantation with a capsular tension ring: prospective randomized paired-eye study
Purpose: To compare the rotational stability and visual outcomes of plate-haptic toric intraocular lenses (IOLs) with and without a capsular tension ring (CTR) in paired eyes. Setting: Eye and Ears, Nose, and Throat Hospital of Fudan University, Shanghai, China. Design: Prospective, randomized, paired-eye study. Methods: Patients with bilateral cataracts and coexisting regular corneal astigmatism were enrolled. The 2 eyes of each patient were randomly assigned to the CTR or non-CTR (NCTR) group. Both eyes of each patient were subjected to phacoemulsification and toric IOL implantation. CTRs were implanted into the eyes of the CTR group. All patients were followed up for 12 months; uncorrected distance visual acuity (UDVA), residual astigmatism (RAS), and rotational degree of the toric IOL were recorded. Results: 186 eyes of 93 patients were eligible for analysis. At each visit, UDVA improved significantly postoperatively in all eyes (P < .001). The mean rotational degree and RAS were significantly smaller in the CTR group at the 2-week visit (P < .05). The toric IOLs achieved rotational stability at 1 week postoperatively in the CTR group while at 2 weeks postoperatively in the NCTR group. In the subgroup analyses, CTR coimplantation significantly reduced the 2-week IOL rotation in eyes meeting specific ocular measurements. Conclusions: CTR coimplantation could increase the rotational stability of plate-haptic toric IOLs, by reducing the amount of IOL rotation in the early postoperative period and accelerating the stabilization of IOLs in the capsular bag.
- 1 January 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (1) , 31-39
Open AccessRotational stability of plate-haptic toric intraocular lenses implantation with a capsular tension ring: prospective randomized paired-eye study
Purpose: To compare the rotational stability and visual outcomes of plate-haptic toric intraocular lenses (IOLs) with and without a capsular tension ring (CTR) in paired eyes. Setting: Eye and Ears, Nose, and Throat Hospital of Fudan University, Shanghai, China. Design: Prospective, randomized, paired-eye study. Methods: Patients with bilateral cataracts and coexisting regular corneal astigmatism were enrolled. The 2 eyes of each patient were randomly assigned to the CTR or non-CTR (NCTR) group. Both eyes of each patient were subjected to phacoemulsification and toric IOL implantation. CTRs were implanted into the eyes of the CTR group. All patients were followed up for 12 months; uncorrected distance visual acuity (UDVA), residual astigmatism (RAS), and rotational degree of the toric IOL were recorded. Results: 186 eyes of 93 patients were eligible for analysis. At each visit, UDVA improved significantly postoperatively in all eyes (P < .001). The mean rotational degree and RAS were significantly smaller in the CTR group at the 2-week visit (P < .05). The toric IOLs achieved rotational stability at 1 week postoperatively in the CTR group while at 2 weeks postoperatively in the NCTR group. In the subgroup analyses, CTR coimplantation significantly reduced the 2-week IOL rotation in eyes meeting specific ocular measurements. Conclusions: CTR coimplantation could increase the rotational stability of plate-haptic toric IOLs, by reducing the amount of IOL rotation in the early postoperative period and accelerating the stabilization of IOLs in the capsular bag.
- 1 March 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (3) , 253-258
Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors
Purpose: To investigate the rotational stability of plate-haptic toric intraocular lenses (IOLs) during 3-month follow-up. Setting: Eye and ENT Hospital of Fudan University, Shanghai, China. Design: Prospective observational study. Methods: Patients with cataracts implanted with AT TORBI 709M toric IOLs were enrolled and followed at 1 hour, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was applied to investigate the time course of absolute IOL rotation change. The 2-week overall IOL rotation was analyzed in the age, sex, axial length (AL), lens thickness (LT), preexisting astigmatism, and white-to-white subgroups. Results: A total of 328 eyes of 258 patients were included. The rotation from the end of surgery to 1 hour and 1 day to 3 days was significantly smaller compared with the rotation from 1 hour to 1 day but more than that at other time intervals in the overall group. 2 weeks postoperatively, the mean uncorrected distance visual acuity and remaining positive cylinder were 0.19 ± 0.22 logMAR and 0.60 ± 0.44 diopters, respectively. Significant between-group differences in 2-week overall rotation were found in the age, AL, and LT subgroups. Conclusions: Maximum rotation occurred within 1 hour to 1 day postoperatively, and the first 3 days postoperatively was a high-risk period for the plate-haptic toric IOL rotation. Surgeons should make the patients aware of this.
- 1 March 2023
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 49 (3) , 253-258
Rotational stability of plate-haptic toric intraocular lenses in Asian eyes: risk period for intraocular lens rotation and its influencing factors
Purpose: To investigate the rotational stability of plate-haptic toric intraocular lenses (IOLs) during 3-month follow-up. Setting: Eye and ENT Hospital of Fudan University, Shanghai, China. Design: Prospective observational study. Methods: Patients with cataracts implanted with AT TORBI 709M toric IOLs were enrolled and followed at 1 hour, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was applied to investigate the time course of absolute IOL rotation change. The 2-week overall IOL rotation was analyzed in the age, sex, axial length (AL), lens thickness (LT), preexisting astigmatism, and white-to-white subgroups. Results: A total of 328 eyes of 258 patients were included. The rotation from the end of surgery to 1 hour and 1 day to 3 days was significantly smaller compared with the rotation from 1 hour to 1 day but more than that at other time intervals in the overall group. 2 weeks postoperatively, the mean uncorrected distance visual acuity and remaining positive cylinder were 0.19 ± 0.22 logMAR and 0.60 ± 0.44 diopters, respectively. Significant between-group differences in 2-week overall rotation were found in the age, AL, and LT subgroups. Conclusions: Maximum rotation occurred within 1 hour to 1 day postoperatively, and the first 3 days postoperatively was a high-risk period for the plate-haptic toric IOL rotation. Surgeons should make the patients aware of this.
- Open Access
- 20 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
Toric Intraocular Lens Implantation in the Correction of Moderate‐To‐High Corneal Astigmatism in Cataract Patients: Clinical Efficacy and Safety
Background/Aims . To investigate the long‐term efficacy and rotational stability of toric intraocular lenses (IOLs) implanted for the correction of moderate‐to‐high corneal astigmatism. Methods . A total of 57 cataract patients (57 eyes) with regular corneal astigmatism (≥2.57 D) were enrolled in this retrospective cohort study. Phacoemulsification with toric IOL implantation was performed for all patients. The uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were recorded before and one year after surgery, and statistical analysis of preoperative corneal astigmatism, postoperative residual astigmatism, aberrations, IOL rotation, and related factors was performed to evaluate the efficacy, safety, and stability of toric IOLs in correcting moderate‐to‐high corneal astigmatism. Results . One year after surgery, visual acuity was significantly improved compared with that before surgery (preoperative log MAR 0.87 ± 0.34 vs. postoperative log MAR 0.31 ± 0.26, p < 0.001), and the self‐reported spectacle independence rate was 68.42%. The total residual astigmatism was 1.18 ± 0.85 D, which was significantly less than the preoperative value (3.41 ± 0.99 D) ( p < 0.001). The degree of toric IOL rotation was 4.93 ± 3.02°, and 54.39% of patients had a lens rotation of less than 5°. The IOLs of 5.26% (3 eyes) of patients rotated more than 10°, and these patients received glasses instead of undergoing IOL repositioning. Conclusions . Toric IOL implantation provided optimal vision outcomes and low spectacle dependence during a one‐year follow‐up period. The results from our study show that toric IOL implantation is a safe and effective option for cataract patients with moderate‐to‐high corneal astigmatism.
- 20 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
Open AccessToric Intraocular Lens Implantation in the Correction of Moderate‐To‐High Corneal Astigmatism in Cataract Patients: Clinical Efficacy and Safety
Background/Aims . To investigate the long‐term efficacy and rotational stability of toric intraocular lenses (IOLs) implanted for the correction of moderate‐to‐high corneal astigmatism. Methods . A total of 57 cataract patients (57 eyes) with regular corneal astigmatism (≥2.57 D) were enrolled in this retrospective cohort study. Phacoemulsification with toric IOL implantation was performed for all patients. The uncorrected visual acuity (UCVA) and best corrected visual acuity (BCVA) were recorded before and one year after surgery, and statistical analysis of preoperative corneal astigmatism, postoperative residual astigmatism, aberrations, IOL rotation, and related factors was performed to evaluate the efficacy, safety, and stability of toric IOLs in correcting moderate‐to‐high corneal astigmatism. Results . One year after surgery, visual acuity was significantly improved compared with that before surgery (preoperative log MAR 0.87 ± 0.34 vs. postoperative log MAR 0.31 ± 0.26, p < 0.001), and the self‐reported spectacle independence rate was 68.42%. The total residual astigmatism was 1.18 ± 0.85 D, which was significantly less than the preoperative value (3.41 ± 0.99 D) ( p < 0.001). The degree of toric IOL rotation was 4.93 ± 3.02°, and 54.39% of patients had a lens rotation of less than 5°. The IOLs of 5.26% (3 eyes) of patients rotated more than 10°, and these patients received glasses instead of undergoing IOL repositioning. Conclusions . Toric IOL implantation provided optimal vision outcomes and low spectacle dependence during a one‐year follow‐up period. The results from our study show that toric IOL implantation is a safe and effective option for cataract patients with moderate‐to‐high corneal astigmatism.
- Retracted
- 9 January 2020
- Published by Elsevier in International Immunopharmacology
- Vol. 80, 106123
RETRACTED: Oroxylin A inhibits carcinogen-induced skin tumorigenesis through inhibition of inflammation by regulating SHCBP1 in mice
- 9 January 2020
- Published by Elsevier in International Immunopharmacology
- Vol. 80, 106123
RetractedRETRACTED: Oroxylin A inhibits carcinogen-induced skin tumorigenesis through inhibition of inflammation by regulating SHCBP1 in mice