Pradeep Sivanantham
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pradeep Sivanantham has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Beulah Gnana Ananthi Gurupatham
Department of Civil Engineering, College of Engineering Guindy Campus, Anna University, Chennai 600025, India
3 shared publications - Krishanu Roy
School of Engineering, Civil Engineering, The University of Waikato, Hamilton 3216, New Zealand
3 shared publications - Deepak Pugazhlendi
Department of Civil Engineering, SRM Institute of Science and Technology, Chennai 603203, India
2 shared publications - Karthikeyan Rajendiran
Department of Civil Engineering SRMIST, Chennai 603203, India
1 shared publication - Satyanarayanan Kachabeswara Srinivasan
Civil Engineering Department, SRM Institute of Science & Technology, Kattankulathur, India
1 shared publication - Senthil Selvan Subramanian
Department of Civil Engineering, SRM Institute of Science and Technology, Kattankulathur, India
1 shared publication
Latest Publications
- Open Access
Influence of Infill on Reinforced Concrete Frame Resting on Slopes under Lateral Loading
When compared to traditional reinforced concrete constructions on level surfaces, buildings situated on hills with slopes require additional consideration, particularly when seismic loading is an important factor. In hilly slopes, the ground-level columns of structures have different heights due to the nature of the slope, which leads to a short column effect. This paper represents an experimental and analytical investigation of the behaviour of reinforced concrete frames and their response in sloped regions of hills, in which global retrofitting techniques were adopted by providing solid infill in the short column effect zone for the columns in the same storey of differentheights. Numerical analysis was conducted on how infill affected the short column effect under lateral cyclic loads. It was discovered that compared to bare reinforced concrete frames, masonry infill greatly increased the lateral load-carrying capacity by up to 50%. In the meantime, the frame’s ability to dissipate energy increased linearly. After infill was added to the frame with the short column effect, the reinforced concrete structure’s different reactions, including ultimate load displacement, crack pattern, energy dissipation, and energy absorption, were examined. With the addition of a solid infill, the reinforced concrete structure’s lateral strength and energy dissipation capacity were increased by 2.45 times. The damage development on the reinforced concrete frame with infill and the short column effect was less impacted by lateral stress than the reinforced concrete frame without infill.
Open AccessInfluence of Infill on Reinforced Concrete Frame Resting on Slopes under Lateral Loading
When compared to traditional reinforced concrete constructions on level surfaces, buildings situated on hills with slopes require additional consideration, particularly when seismic loading is an important factor. In hilly slopes, the ground-level columns of structures have different heights due to the nature of the slope, which leads to a short column effect. This paper represents an experimental and analytical investigation of the behaviour of reinforced concrete frames and their response in sloped regions of hills, in which global retrofitting techniques were adopted by providing solid infill in the short column effect zone for the columns in the same storey of differentheights. Numerical analysis was conducted on how infill affected the short column effect under lateral cyclic loads. It was discovered that compared to bare reinforced concrete frames, masonry infill greatly increased the lateral load-carrying capacity by up to 50%. In the meantime, the frame’s ability to dissipate energy increased linearly. After infill was added to the frame with the short column effect, the reinforced concrete structure’s different reactions, including ultimate load displacement, crack pattern, energy dissipation, and energy absorption, were examined. With the addition of a solid infill, the reinforced concrete structure’s lateral strength and energy dissipation capacity were increased by 2.45 times. The damage development on the reinforced concrete frame with infill and the short column effect was less impacted by lateral stress than the reinforced concrete frame without infill.
- Open Access
- 6 December 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (12) , 374
Influence of Steel Fiber and Carbon Fiber Mesh on Plastic Hinge Length of RCC Beams under Monotonic Loading
The most susceptible area of a structural member, where the most inelastic rotation would take place, is the plastic hinge. At this stage, flexural elements in particular achieve their maximal bending flexibility. This study uses finite element analysis (FEA) and experimental inquiry to analyze and test the effects of carbon fiber mesh jacketing and steel fiber reinforcement at the concrete beam’s plastic hinge length subjected to a vertical monotonic load. The compressive strength, split tensile strength, and flexural strength tests are used to evaluate the mechanical qualities, such as compressive strength and tensile strength, of M25 grade concrete that is used to cast specimens. While conducting this analysis, seven different parameters are taken into account. After the conventional concrete beam has been cast, the steel-fiber reinforced beam is cast. Several empirical formulas drawn from Baker, Sawyer, Corley, Mattock, Paulay, Priestley, and Park’s methods were used to calculate the length of the beam’s plastic hinge. Finally, the steel fiber was inserted independently at 150 mm into the concrete beam’s plastic hinge length mechanism using the techniques described by Paulay and Priestley. The analytical and experimental results are compared. The results obtained from the investigations by applying monotonic loads to the beam show that fibers used at specific plastic hinge lengths show a 41 kN ultimate load with 11.63 mm displacement, which is similar to that of conventional beam displacement, and performance. Meanwhile, the carbon fiber mesh wrapped throughout the beam behaves better than other members, showing an ultimate load of 64 kN with a 15.95 mm deflection. The fibers provided at the plastic hinge length of the beam perform similarly to those of a conventional beam; eventually, they become economical without sacrificing strength.
- 6 December 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (12) , 374
Open AccessInfluence of Steel Fiber and Carbon Fiber Mesh on Plastic Hinge Length of RCC Beams under Monotonic Loading
The most susceptible area of a structural member, where the most inelastic rotation would take place, is the plastic hinge. At this stage, flexural elements in particular achieve their maximal bending flexibility. This study uses finite element analysis (FEA) and experimental inquiry to analyze and test the effects of carbon fiber mesh jacketing and steel fiber reinforcement at the concrete beam’s plastic hinge length subjected to a vertical monotonic load. The compressive strength, split tensile strength, and flexural strength tests are used to evaluate the mechanical qualities, such as compressive strength and tensile strength, of M25 grade concrete that is used to cast specimens. While conducting this analysis, seven different parameters are taken into account. After the conventional concrete beam has been cast, the steel-fiber reinforced beam is cast. Several empirical formulas drawn from Baker, Sawyer, Corley, Mattock, Paulay, Priestley, and Park’s methods were used to calculate the length of the beam’s plastic hinge. Finally, the steel fiber was inserted independently at 150 mm into the concrete beam’s plastic hinge length mechanism using the techniques described by Paulay and Priestley. The analytical and experimental results are compared. The results obtained from the investigations by applying monotonic loads to the beam show that fibers used at specific plastic hinge lengths show a 41 kN ultimate load with 11.63 mm displacement, which is similar to that of conventional beam displacement, and performance. Meanwhile, the carbon fiber mesh wrapped throughout the beam behaves better than other members, showing an ultimate load of 64 kN with a 15.95 mm deflection. The fibers provided at the plastic hinge length of the beam perform similarly to those of a conventional beam; eventually, they become economical without sacrificing strength.
- Open Access
- 2 June 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (6) , 164
Plastic Hinge Length Mechanism of Steel-Fiber-Reinforced Concrete Slab under Repeated Loading
The plastic hinge is the most critical damaging part of a structural element, where the highest inelastic rotation would occur. In particular, flexural members develop maximum bending abilities at that point. The current paper experimentally investigates the influence of steel fiber reinforcement at the plastic hinge length of the concrete slab under repeated loading, something which has not been reported by any researcher. Mechanical properties such as compressive strength and tensile strength of M20-grade concrete that are used for casting specimens are tested through the compressive strength test and the split tensile strength test. Six different parameters are considered in the slab while carrying out this study. First, the conventional concrete slab and then the steel-fiber-reinforced slab were cast. The plastic hinge length of the slab was calculated through different empirical expressions taken from methods by Baker, Sawyer, Corley, Mattock, Paulay, Priestley and Park. Finally, the steel fiber was added as per methods detailed by Paulay, Priestley and Park in the plastic hinge length mechanism in the concrete slab at 70 mm and 150 mm separately. The results arrived through experimental investigation by applying repeated loads to the slab, indicating that steel fibers used at critical sections of plastic hinge length provide similar strength, displacement, and performance as that of the conventional RCC slab and fully steel-fiber-reinforced concrete slabs. Steel fiber at a plastic hinge length of slab has a better advantage over a conventional slab.
- 2 June 2022
- Published by MDPI AG in Journal of Composites Science
- Vol. 6 (6) , 164
Open AccessPlastic Hinge Length Mechanism of Steel-Fiber-Reinforced Concrete Slab under Repeated Loading
The plastic hinge is the most critical damaging part of a structural element, where the highest inelastic rotation would occur. In particular, flexural members develop maximum bending abilities at that point. The current paper experimentally investigates the influence of steel fiber reinforcement at the plastic hinge length of the concrete slab under repeated loading, something which has not been reported by any researcher. Mechanical properties such as compressive strength and tensile strength of M20-grade concrete that are used for casting specimens are tested through the compressive strength test and the split tensile strength test. Six different parameters are considered in the slab while carrying out this study. First, the conventional concrete slab and then the steel-fiber-reinforced slab were cast. The plastic hinge length of the slab was calculated through different empirical expressions taken from methods by Baker, Sawyer, Corley, Mattock, Paulay, Priestley and Park. Finally, the steel fiber was added as per methods detailed by Paulay, Priestley and Park in the plastic hinge length mechanism in the concrete slab at 70 mm and 150 mm separately. The results arrived through experimental investigation by applying repeated loads to the slab, indicating that steel fibers used at critical sections of plastic hinge length provide similar strength, displacement, and performance as that of the conventional RCC slab and fully steel-fiber-reinforced concrete slabs. Steel fiber at a plastic hinge length of slab has a better advantage over a conventional slab.