Aurnab Mandal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Aurnab Mandal has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Bvvsn Prabhakar Rao
Laboratory of MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science Pilani, Hyderabad Campus, Hyderabad, India
2 shared publications - Khairunnisa Amreen
Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India
2 shared publications - Mary Salve
Department of Electrical and Electronics Engineering, MEMS, Microfluidics and Nanoelectronics Laboratory, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India
2 shared publications - Prasant Kumar Pattnaik
School of Computer Engineering, KIIT Deemed to be University, Bhubaneswar, India
2 shared publications - Sanket Goel
Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad, India
2 shared publications
Latest Publications
- Open Access
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-2
Erratum to “A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out”
In the above article [1] , the corrected Table I is shown below.
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-2
Open AccessErratum to “A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out”
In the above article [1] , the corrected Table I is shown below.
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out
Herein, a portable 3D-printed miniaturized bipolar electrode-electrochemiluminescence (BPE-ECL) platform is presented. The platform has a smartphone enabled read-out method for ECL signal analysis, 9 V Hi-watt battery for power supply and graphtized mesoporous carbon/multiwalled carbon nanotube (GMC/MWCNT) nanomaterial modified pencil graphite electrodes (PGE) as bipolar and driving electrodes. The nanomaterial modified pencil graphite bipolar electrode (PG-BPE) showed great electro-catalytic activity towards luminol-H2O2, luminol-O2 ECL reaction in neutral medium. The sensitized luminol-O2, luminol-H2O2 reactions were successfully applied for sensing of H2O2, O2 and CO2. With optimize parameters determination of H2O2, O2 and CO2 can be in the linear range of 0.08 μM -5000 μM, 0.3 - 9 mg/L, 0.6 - 9 mg/L with detection limit of 0.069 μM, 0.15 mg/L, 0.45 mg/L. As a prototype application, quantitative detection of glucose has been carried out with modified PGE anchored with GOX (GMC/MWCNT@GOX). The prepared electrode was analysed for physico-chemical and microscopic characterizations. The modified PGE showed an excellent ability to detect glucose in a linear range of 1 μM – 10 mM with a detection limit of 0.31 μM. Finally, the platform was subjected to real sample analysis of H2O2 in clinical H2O2, cosmetic bleach, O2 and CO2 in lake water and tap water, and glucose in human blood serum samples. The results indicated that the proposed platform offered excellent reliability, accuracy and amenable to be used for multiple point-of-care biochemical analysis.
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out
Herein, a portable 3D-printed miniaturized bipolar electrode-electrochemiluminescence (BPE-ECL) platform is presented. The platform has a smartphone enabled read-out method for ECL signal analysis, 9 V Hi-watt battery for power supply and graphtized mesoporous carbon/multiwalled carbon nanotube (GMC/MWCNT) nanomaterial modified pencil graphite electrodes (PGE) as bipolar and driving electrodes. The nanomaterial modified pencil graphite bipolar electrode (PG-BPE) showed great electro-catalytic activity towards luminol-H2O2, luminol-O2 ECL reaction in neutral medium. The sensitized luminol-O2, luminol-H2O2 reactions were successfully applied for sensing of H2O2, O2 and CO2. With optimize parameters determination of H2O2, O2 and CO2 can be in the linear range of 0.08 μM -5000 μM, 0.3 - 9 mg/L, 0.6 - 9 mg/L with detection limit of 0.069 μM, 0.15 mg/L, 0.45 mg/L. As a prototype application, quantitative detection of glucose has been carried out with modified PGE anchored with GOX (GMC/MWCNT@GOX). The prepared electrode was analysed for physico-chemical and microscopic characterizations. The modified PGE showed an excellent ability to detect glucose in a linear range of 1 μM – 10 mM with a detection limit of 0.31 μM. Finally, the platform was subjected to real sample analysis of H2O2 in clinical H2O2, cosmetic bleach, O2 and CO2 in lake water and tap water, and glucose in human blood serum samples. The results indicated that the proposed platform offered excellent reliability, accuracy and amenable to be used for multiple point-of-care biochemical analysis.