Bvvsn Prabhakar Rao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bvvsn Prabhakar Rao has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Sanket Goel
Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad, India
4 shared publications - Khairunnisa Amreen
Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India
3 shared publications - Prasant Kumar Pattnaik
School of Computer Engineering, KIIT Deemed to be University, Bhubaneswar, India
3 shared publications - Aurnab Mandal
MEMS, Microfluidics and Nanoelectronics Laboratory, Birla Institute of Technology and Science, Pilani, Hyderabad, India
2 shared publications - Mary Salve
Department of Electrical and Electronics Engineering, MEMS, Microfluidics and Nanoelectronics Laboratory, Birla Institute of Technology and Science (BITS) Pilani, Hyderabad Campus, Hyderabad, India
2 shared publications - Ankit Patil
Laboratory of MEMS, Microfluidics and Nanoelectronics (MMNE) Lab, Birla Institute of Technology and Science Pilani, Hyderabad Campus, Hyderabad, India
1 shared publication
Latest Publications
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (1) , 45-51
Enhanced Electrochemical Sensitivity and Performance Using 3D Printed and Screen Printed Interdigitated Three-Electrode System
Three-electrode miniaturized interdigitated system (IDEs) for electrochemical measurements with enhanced sensitivity and performance was reported here. The system included a reference electrode, a counter electrode, and a working electrode, all configured as interconnected electrodes. Present work focused on optimizing the number of working electrodes and their geometric parameters to achieve peak performance, with bench marking system Potassium Ferricyanide. This optimization addressed the critical interplay between capacitance, resistance, sensitivity, and aspect ratio. Unlike previous configurations where the reference electrode was separated from the interdigitated design, the present approach integrates the reference electrode into the interdigitated configuration, greatly increasing sensitivity. Despite using a low-cost conductive material such as carbon PLA (polylactic acid) for 3D printed (3DP) electrodes, in a three-electrode interdigitated system, the current observed at the oxidation peak showed a significant increase of 97-98%, while the reduction peak exhibits an increase of 65-66% compared to the two-electrode interdigitated system. The screen-printed (SP) electrodes used for design validation exhibited minimal variation in cycles in a two working electrode interdigitated configuration. This progress highlighted the potential of interconnected electrodes in developing susceptible and efficient electrochemical sensors.
- 29 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nanobioscience
- Vol. 25 (1) , 45-51
Enhanced Electrochemical Sensitivity and Performance Using 3D Printed and Screen Printed Interdigitated Three-Electrode System
Three-electrode miniaturized interdigitated system (IDEs) for electrochemical measurements with enhanced sensitivity and performance was reported here. The system included a reference electrode, a counter electrode, and a working electrode, all configured as interconnected electrodes. Present work focused on optimizing the number of working electrodes and their geometric parameters to achieve peak performance, with bench marking system Potassium Ferricyanide. This optimization addressed the critical interplay between capacitance, resistance, sensitivity, and aspect ratio. Unlike previous configurations where the reference electrode was separated from the interdigitated design, the present approach integrates the reference electrode into the interdigitated configuration, greatly increasing sensitivity. Despite using a low-cost conductive material such as carbon PLA (polylactic acid) for 3D printed (3DP) electrodes, in a three-electrode interdigitated system, the current observed at the oxidation peak showed a significant increase of 97-98%, while the reduction peak exhibits an increase of 65-66% compared to the two-electrode interdigitated system. The screen-printed (SP) electrodes used for design validation exhibited minimal variation in cycles in a two working electrode interdigitated configuration. This progress highlighted the potential of interconnected electrodes in developing susceptible and efficient electrochemical sensors.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (4) , 1-4
Boron Doped Laser-Induced Graphene: A Suitable Substrate for Flexible and Wearable Sensor and Supercapacitor
In this letter, a new approach for the development of boron-doped laser-induced gra-phene (LIG) employing a blue visible light laser is presented. The doped graphitized electrode shows good electrical conductivity compared with bare LIG. The synthesized substrate is flexible and wearable, making it appropriate for different relevant applications, such as supercapacitors and sensing. Morphological analysis techniques, such as SEM and EDX, are employed for material characterization. Doped LIG shows potential for energy storage and physical sensors. Cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD) techniques are employed to characterize the electrochemical characterization of the supercapacitor. These techniques assess the electrochemical performance of the devices. Electrical characterization is utilized in physical sensor characterization.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (4) , 1-4
Boron Doped Laser-Induced Graphene: A Suitable Substrate for Flexible and Wearable Sensor and Supercapacitor
In this letter, a new approach for the development of boron-doped laser-induced gra-phene (LIG) employing a blue visible light laser is presented. The doped graphitized electrode shows good electrical conductivity compared with bare LIG. The synthesized substrate is flexible and wearable, making it appropriate for different relevant applications, such as supercapacitors and sensing. Morphological analysis techniques, such as SEM and EDX, are employed for material characterization. Doped LIG shows potential for energy storage and physical sensors. Cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD) techniques are employed to characterize the electrochemical characterization of the supercapacitor. These techniques assess the electrochemical performance of the devices. Electrical characterization is utilized in physical sensor characterization.
- 7 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 30 (6) , 755-768
Memristors Enabled Computing Correlation Parameter In-Memory System: A Potential Alternative to Von Neumann Architecture
The von Neumann bottleneck has significantly increased the energy consumption of processing units and memory systems, especially in data-intensive computations such as the correlation parameter, which is being used in medical research, financial market analysis, biometrics, etc. Recently, memristor-enabled in-memory processing has gained tremendous research attraction to extenuate the von Neumann bottleneck as it processes operands at the location of storage, which obviates the need to transfer data between memory and the processing units. Hence, in this article, an innovative memristor crossbar-based architecture computing correlation parameter in-memory (CoCoPIM) has been proposed to accelerate correlation coefficient computations. Three different applications such as computing correlation between electrocardiogram (ECG) signals, faces, and H1N1 models were implemented based on the architecture. To evaluate the architecture, Neurosim was modified to support data mapping and computation steps, whereas Micro Architectural and System Simulator (MARSS) and multicore power, area, and timing (McPAT) were used to evaluate the von Neumann machine. In these applications, it was found that CoCoPIM was$41.04\times $ ,$66.5\times $ ,$67\times $ , and$33.2\times $ times energy-efficient against a four-core out-of-order processor in performing the respective tasks. It also achieved a speedup of$143.5\times $ ,$52.5\times $ ,$52.5\times $ , and$597\times $ times against the same von Neumann machine (multicore processor) for the respective tasks.- 7 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Very Large Scale Integration (VLSI) Systems
- Vol. 30 (6) , 755-768
Memristors Enabled Computing Correlation Parameter In-Memory System: A Potential Alternative to Von Neumann Architecture
The von Neumann bottleneck has significantly increased the energy consumption of processing units and memory systems, especially in data-intensive computations such as the correlation parameter, which is being used in medical research, financial market analysis, biometrics, etc. Recently, memristor-enabled in-memory processing has gained tremendous research attraction to extenuate the von Neumann bottleneck as it processes operands at the location of storage, which obviates the need to transfer data between memory and the processing units. Hence, in this article, an innovative memristor crossbar-based architecture computing correlation parameter in-memory (CoCoPIM) has been proposed to accelerate correlation coefficient computations. Three different applications such as computing correlation between electrocardiogram (ECG) signals, faces, and H1N1 models were implemented based on the architecture. To evaluate the architecture, Neurosim was modified to support data mapping and computation steps, whereas Micro Architectural and System Simulator (MARSS) and multicore power, area, and timing (McPAT) were used to evaluate the von Neumann machine. In these applications, it was found that CoCoPIM was$41.04\times $ ,$66.5\times $ ,$67\times $ , and$33.2\times $ times energy-efficient against a four-core out-of-order processor in performing the respective tasks. It also achieved a speedup of$143.5\times $ ,$52.5\times $ ,$52.5\times $ , and$597\times $ times against the same von Neumann machine (multicore processor) for the respective tasks.- Open Access
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-2
Erratum to “A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out”
In the above article [1] , the corrected Table I is shown below.
- 23 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-2
Open AccessErratum to “A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out”
In the above article [1] , the corrected Table I is shown below.
- 7 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6232-6246
Sensing Techniques and Interrogation Methods in Optical MEMS Accelerometers: A Review
In this article, we review optical MEMS accelerometers with a particular focus on sensing techniques and interrogation methods. Optical accelerometers find use in various application domains ranging from microgravity to inertial navigation to vibration sensing. The performance of an accelerometer is quantified in terms of its range, bandwidth, sensitivity, and resolution. The combination of sensing technique and interrogation method determines the optical accelerometer’s performance. This article presents a classification in terms of guided-wave and free-space based optical sensing techniques used in acceleration measurement and their review. In free-space based sensing techniques, light propagating in free-space interacts with the mechanical structure resulting in modification of light properties at the receiver. In guided-wave based sensing techniques, light interaction with the mechanical structure is confined to the waveguide. Also, the different interrogation methods used in optical MEMS accelerometers are reviewed. The interrogation methods are classified as based on intensity modulation or frequency modulation of the optical signal received from sensor. In intensity-modulation based interrogation, light intensity at output is the measurand and, the cost and complexity of this class of methods is lower. In frequency-modulation based interrogation, the frequency or phase of the optical signal at the output is the measurand. Further, a high-resolution optical MEMS accelerometer based on waveguide Bragg gratings is described. A combination of free-space based sensing and intensity-modulation based interrogation methods will be suitable for consumer-grade accelerometer applications. For high-resolution applications like tactical and navigation grades, a combination of guided-wave sensing and frequency-modulation based interrogation methods would be appropriate.
- 7 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (7) , 6232-6246
Sensing Techniques and Interrogation Methods in Optical MEMS Accelerometers: A Review
In this article, we review optical MEMS accelerometers with a particular focus on sensing techniques and interrogation methods. Optical accelerometers find use in various application domains ranging from microgravity to inertial navigation to vibration sensing. The performance of an accelerometer is quantified in terms of its range, bandwidth, sensitivity, and resolution. The combination of sensing technique and interrogation method determines the optical accelerometer’s performance. This article presents a classification in terms of guided-wave and free-space based optical sensing techniques used in acceleration measurement and their review. In free-space based sensing techniques, light propagating in free-space interacts with the mechanical structure resulting in modification of light properties at the receiver. In guided-wave based sensing techniques, light interaction with the mechanical structure is confined to the waveguide. Also, the different interrogation methods used in optical MEMS accelerometers are reviewed. The interrogation methods are classified as based on intensity modulation or frequency modulation of the optical signal received from sensor. In intensity-modulation based interrogation, light intensity at output is the measurand and, the cost and complexity of this class of methods is lower. In frequency-modulation based interrogation, the frequency or phase of the optical signal at the output is the measurand. Further, a high-resolution optical MEMS accelerometer based on waveguide Bragg gratings is described. A combination of free-space based sensing and intensity-modulation based interrogation methods will be suitable for consumer-grade accelerometer applications. For high-resolution applications like tactical and navigation grades, a combination of guided-wave sensing and frequency-modulation based interrogation methods would be appropriate.
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out
Herein, a portable 3D-printed miniaturized bipolar electrode-electrochemiluminescence (BPE-ECL) platform is presented. The platform has a smartphone enabled read-out method for ECL signal analysis, 9 V Hi-watt battery for power supply and graphtized mesoporous carbon/multiwalled carbon nanotube (GMC/MWCNT) nanomaterial modified pencil graphite electrodes (PGE) as bipolar and driving electrodes. The nanomaterial modified pencil graphite bipolar electrode (PG-BPE) showed great electro-catalytic activity towards luminol-H2O2, luminol-O2 ECL reaction in neutral medium. The sensitized luminol-O2, luminol-H2O2 reactions were successfully applied for sensing of H2O2, O2 and CO2. With optimize parameters determination of H2O2, O2 and CO2 can be in the linear range of 0.08 μM -5000 μM, 0.3 - 9 mg/L, 0.6 - 9 mg/L with detection limit of 0.069 μM, 0.15 mg/L, 0.45 mg/L. As a prototype application, quantitative detection of glucose has been carried out with modified PGE anchored with GOX (GMC/MWCNT@GOX). The prepared electrode was analysed for physico-chemical and microscopic characterizations. The modified PGE showed an excellent ability to detect glucose in a linear range of 1 μM – 10 mM with a detection limit of 0.31 μM. Finally, the platform was subjected to real sample analysis of H2O2 in clinical H2O2, cosmetic bleach, O2 and CO2 in lake water and tap water, and glucose in human blood serum samples. The results indicated that the proposed platform offered excellent reliability, accuracy and amenable to be used for multiple point-of-care biochemical analysis.
- 10 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 70 (00189456) , 1-10
A Portable 3-D Printed Electrochemiluminescence Platform With Pencil Graphite Electrodes for Point-of-Care Multiplexed Analysis With Smartphone-Based Read Out
Herein, a portable 3D-printed miniaturized bipolar electrode-electrochemiluminescence (BPE-ECL) platform is presented. The platform has a smartphone enabled read-out method for ECL signal analysis, 9 V Hi-watt battery for power supply and graphtized mesoporous carbon/multiwalled carbon nanotube (GMC/MWCNT) nanomaterial modified pencil graphite electrodes (PGE) as bipolar and driving electrodes. The nanomaterial modified pencil graphite bipolar electrode (PG-BPE) showed great electro-catalytic activity towards luminol-H2O2, luminol-O2 ECL reaction in neutral medium. The sensitized luminol-O2, luminol-H2O2 reactions were successfully applied for sensing of H2O2, O2 and CO2. With optimize parameters determination of H2O2, O2 and CO2 can be in the linear range of 0.08 μM -5000 μM, 0.3 - 9 mg/L, 0.6 - 9 mg/L with detection limit of 0.069 μM, 0.15 mg/L, 0.45 mg/L. As a prototype application, quantitative detection of glucose has been carried out with modified PGE anchored with GOX (GMC/MWCNT@GOX). The prepared electrode was analysed for physico-chemical and microscopic characterizations. The modified PGE showed an excellent ability to detect glucose in a linear range of 1 μM – 10 mM with a detection limit of 0.31 μM. Finally, the platform was subjected to real sample analysis of H2O2 in clinical H2O2, cosmetic bleach, O2 and CO2 in lake water and tap water, and glucose in human blood serum samples. The results indicated that the proposed platform offered excellent reliability, accuracy and amenable to be used for multiple point-of-care biochemical analysis.