KIKoki Ito

Koki Ito

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Koki Ito has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Magnetic Interaction Effect on Stall Torque of IPM-type Magnetic-Geared Generator

    by Boqun Dai, Koki Ito, Kenji Nakamura

    Magnetic-geared generators (MGGs) are expected to be applied to wind-power generation because of maintenance-free, high torque density and efficiency. Among them, an interior permanent magnet (IPM)-type MGG has superior characteristics compared with a surface permanent magnet (SPM)-type MGG. The stall torque of the IPM-type changes with the current phase angle because of magnetic interaction, while the SPM-type keeps constant. This paper investigates the effect of magnetic interaction on the stall torque of IPM-type MMG using both a three-dimensional finite element method (3D-FEM) and experiments. In addition, since the stall torque can be improved by magnetic interaction, a novel high-speed rotor structure is proposed to maximize the effects of magnetic interaction to achieve the same stall torque while using fewer permanent magnets. The validity of the proposed new high-speed rotor structure is proved by using 3D-FEM.

  • Experimental Verification of Torque Density Improvement by Magnetic Interaction in 500 N·m IPM-Type Magnetic-Geared Motor

    by Keigo Iwaki, Koki Ito, Kenji Nakamura

    Magnetic-geared motors (MGMs) can achieve high torque density without mechanical contact. A previous paper described that an interior permanent magnet (IPM) type MGM has higher efficiency than a conventional surface permanent magnet (SPM) type MGM. However, the permanent magnet motor part and magnetic gear part magnetically interact with each other. In a previous paper, the magnetic interaction in IPM-type MGM was fully clarified. If the magnetic interaction is effectively used, then the torque density of IPM-type MGM may increase without requiring additional magnets. This paper presents an experimental verification of torque density improvement by magnetic interaction. First, the IPM-type MGM with a target torque of 500 N·m is designed by using a three-dimensional finite element method, then it is prototyped and demonstrated. In the prototype tests, the prototype MGM slips at 456 N·m, which is 90% of the target torque. Moreover, the stall torque can be increased to 470 N·m due to magnetic interaction, resulting in a torque density of 83 N·m/L.


  • A Novel Magnetic-Geared Motor Combining Magnetic Gear and SR Motor

    by Keigo Iwaki, Koki Ito, Kenji Nakamura

    A direct-drive permanent magnet (PM) motor and a magnetic-geared PM motor have the advantage of high torque density. Therefore, these motors are expected to be applied as in-wheel motors for electric vehicles (EVs). However, they have a problem that it is difficult to achieve the wide speed-torque characteristics required for EVs. This paper presents a novel magnetic-geared motor that consists of a flux-modulated type magnetic gear and a switched reluctance (SR) motor. In this paper, the SR motor part and the magnetic gear part are designed, and both parts are combined into a magnetic-geared motor. The proposed magnetic-geared motor has the wide speed-torque characteristic, which direct-drive PM motors or SR motors cannot achieve.


  • Proposal and Verification of Torque Equation of IPM-Type Magnetic-Geared Motor

    by Koki Ito, Kenji Nakamura

    Magnetic-geared motors (MGMs) have attracted attention owing to their ability to offer higher torque densities than conventional permanent magnet (PM) motors. An MGM consist of a magnetic gear (MG) part and a PM motor part, which are shared one highspeed-rotor (HSR). An interior permanent magnet (IPM) type and a surface permanent magnet (SPM) type has been proposed as a structure of HSR. In the IPM-type HSR, the PM motor part and MG part are magnetically coupled to each other, which is called a magnetic interaction. However, the torque equation considering this magnetic interaction has not been studied thus far. This paper presents the torque equation of an IPM-type MGM (IPM-MGM). The torque equation considering the magnetic interaction is derived based on the proposed vector diagram, and the parameter identification is conducted by using a two-dimensional finite element method. Moreover, the validity of the torque equation is proved through comparison with experimental results.


  • Investigation of Magnetic Interaction of IPM-Type Magnetic-Geared Motor

    by Koki Ito, Kenji Nakamura

    A magnetic-geared motor (MGM) has attractive features including high torque density, which contributes to reduce overall size and weight in comparison with conventional motors, especially for low-speed and high-torque application. The MGM consists of a magnetic gear (MG) and a permanent magnet (PM) motor, and they share one high-speed-rotor (HSR). In general, the HSR has a structure of surface permanent magnet (SPM) in order to magnetically decouple between the MG and the PM motor by the HSR yoke. However, this structure is cause of the worse eddy current loss in the HSR magnets. In a previous study, to resolve the issue, a structure of interior permanent magnet (IPM) that the HSR magnets are embedded in the HSR yoke was proposed. It was clear that the eddy current loss in the magnets can be reduced and the efficiency is improved. In the IPM structure, however, there is concern that the MG and the PM motor are magnetically interacted and its influence has not been clarified. This paper presents the investigation of the magnetic interaction of the IPM-type MGM by using finite element method (FEM). The influence of the interaction is described by comparing with SPM-type and IPM-type. Moreover, the magnetic interaction is demonstrated by a prototype IPM-type MGM.


  • Open Access

    Preventive effect of low-dose landiolol on postoperative atrial fibrillation study (PELTA study)

    by Konosuke Sasaki, Kiichiro Kumagai, Kay Maeda, Masatoshi Akiyama, Koki Ito, Satoshi Matsuo, Shintaro Katahira, Tomoyuki Suzuki, Yusuke Suzuki, Yu Kaiho, et al.

    Objective To investigate the efficacy of prophylactic administration of low-dose landiolol on postoperative atrial fibrillation (POAF) in patients after cardiovascular surgery. Methods Consecutive 150 patients over 70 years of age who underwent cardiovascular surgery for valvular, ischemic heart, and aortic diseases were enrolled in this single-center prospective randomized control study from 2010 to 2014. They were assigned to three treatment groups: 1γ group (landiolol at 1 μg/kg/min), 2γ group (landiolol at 2 μg/kg/min), or control group (no landiolol). In the two landiolol groups, landiolol hydrochloride was intravenously administered for a period of 4 days postoperatively. Electrocardiography was continuously monitored during the study period, and cardiologists eventually assessed whether POAF occurred or not. Results POAF occurred in 24.4% of patients in the control group, 18.2% in 1γ group, and 11.1% in 2γ group (p = 0.256). Multivariate logistic regression analysis showed that the incidence of POAF tended to decrease depending on the dose of landiolol (trend-p = 0.120; 1γ group: OR = 0.786, 95% CI 0.257–2.404; 2γ group: OR = 0.379, 95% CI 0.112–1.287). Subgroup analysis showed a significant dose-dependent reduction in POAF among categories of female sex, non-use of angiotensin II receptor blockers (ARBs) before surgery, and valve surgery (each trend-p = 0.02, 0.03, and 0.004). Conclusions These findings indicate that prophylactic administration of low-dose landiolol may not be effective for preventing the occurrence of POAF in overall patients after cardiovascular surgery, but the administration could be beneficial to female patients, patients not using ARBs preoperatively, and those after valvular surgery.