Jasprit Pannag
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jasprit Pannag has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Sandra Lee Carroll
School of Nursing, McMaster University, Hamilton, Canada
2 shared publications - Dawn Stacey
School of Nursing, University of Ottawa, Ottawa, Canada
1 shared publication Gayathri Embuldeniya
Hamilton Health Sciences, Hamilton, ON, Canada,
1 shared publicationJeff S Healey
Population Health Research Institute, Hamilton Health Sciences, Hamilton, ON, Canada,
1 shared publication- Jennifer Yost
M. Louise Fitzpatrick College of Nursing Villanova University Villanova Pennsylvania USA
1 shared publication Krystina B Lewis
School of Nursing, University of Ottawa, Ottawa, ON, Canada
1 shared publication
Latest Publications
- Open Access
- 5 December 2020
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 20 (4) , 367-375
Testing a nurse-led, pre-implantation educational intervention for primary prevention implantable cardioverter-defibrillator candidates: a randomized feasibility trial
Aims: Implantable cardioverter-defibrillators (ICDs) deliver therapy for life-threatening arrhythmias. Evidence suggests that ICD candidates have misconceptions regarding ICD therapy and unmet information needs. We undertook a pilot feasibility trial comparing a nurse-led educational intervention plus standard care, vs. standard pre-ICD implantation care. Secondary aims included examination of anxiety, quality of life, and shock anxiety. Methods and results: Implantable cardioverter-defibrillator candidates were consented and randomized to standard pre-ICD implantation care vs. standard care plus a nurse-led educational intervention. The primary feasibility outcomes included: recruitment rate, consent rate, randomization rate, proportion of participants able to complete all questionnaires, time to deliver intervention, and intervention topics completion. At baseline, demographic and Patient-Reported Outcomes Measurement Information System (PROMIS) anxiety scores were collected. Four weeks post-ICD implantation, participants completed the PROMIS, Florida Patient Acceptance Survey (FPAS), and Florida Shock Anxiety Scale (FSAS). Twenty patients consented (10 per group). Feasibility targets were achieved for all but two outcomes: consent rate was 87% vs. 95% target, and completion of data collection measures was 85% vs. 90% target. Consent rate was lower than expected as one patient declined, and two could not be approached. Completion rate was lower than expected as two patients were lost to follow-up, and one did not receive an ICD during the study period, leading to incomplete post-implantation survey collections. Conclusion: The results demonstrate the feasibility of conducting a trial comparing a nurse-led pre-implantation educational intervention to standard care in an outpatient setting. Further study to evaluate the effectiveness of this intervention on patient-reported outcomes is warranted.
- 5 December 2020
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 20 (4) , 367-375
Open AccessTesting a nurse-led, pre-implantation educational intervention for primary prevention implantable cardioverter-defibrillator candidates: a randomized feasibility trial
Aims: Implantable cardioverter-defibrillators (ICDs) deliver therapy for life-threatening arrhythmias. Evidence suggests that ICD candidates have misconceptions regarding ICD therapy and unmet information needs. We undertook a pilot feasibility trial comparing a nurse-led educational intervention plus standard care, vs. standard pre-ICD implantation care. Secondary aims included examination of anxiety, quality of life, and shock anxiety. Methods and results: Implantable cardioverter-defibrillator candidates were consented and randomized to standard pre-ICD implantation care vs. standard care plus a nurse-led educational intervention. The primary feasibility outcomes included: recruitment rate, consent rate, randomization rate, proportion of participants able to complete all questionnaires, time to deliver intervention, and intervention topics completion. At baseline, demographic and Patient-Reported Outcomes Measurement Information System (PROMIS) anxiety scores were collected. Four weeks post-ICD implantation, participants completed the PROMIS, Florida Patient Acceptance Survey (FPAS), and Florida Shock Anxiety Scale (FSAS). Twenty patients consented (10 per group). Feasibility targets were achieved for all but two outcomes: consent rate was 87% vs. 95% target, and completion of data collection measures was 85% vs. 90% target. Consent rate was lower than expected as one patient declined, and two could not be approached. Completion rate was lower than expected as two patients were lost to follow-up, and one did not receive an ICD during the study period, leading to incomplete post-implantation survey collections. Conclusion: The results demonstrate the feasibility of conducting a trial comparing a nurse-led pre-implantation educational intervention to standard care in an outpatient setting. Further study to evaluate the effectiveness of this intervention on patient-reported outcomes is warranted.
- Open Access
- 1 September 2018
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 12, 1947-1954
“I don’t know exactly what you’re referring to”: the challenge of values elicitation in decision making for implantable cardioverter-defibrillators
Purpose: Patients’ values are a key component of patient-centered care and shared decision making in health care organizations. There is limited understanding on how patients’ values guide their health related decision making or how patients understand the concept of values during these processes. This study investigated patients’ understanding of their values in the context of considering the risks/benefits of receiving an implantable cardioverter-defibrillator (ICD). Patients and methods: A qualitative substudy was conducted within a feasibility trial with first-time ICD candidates randomized to receive a patient decision aid or usual care prior to specialist consultation. Semi-structured interviews were conducted with participants post-implantation or post-specialist consultation. Results: Sixteen patients (ten male) aged 47–87 years participated. Of these, ten (62.5%) received the patient decision aid prior to specialist consultation. Findings revealed patients were confused by the word “values” and had difficulty expressing values related to risks/benefits during ICD decision making. When probed, values were conceptualized broadly capturing other factors such as desire to live, good quality of life, family’s views, ICD information, control over decision, and medical authority. Conclusion: This study revealed the difficulty patients considering an ICD had with articulating their values in the context of an ICD health decision and highlighted the challenge to effectively elicit patients’ values within health decisions overall. It is suggested that there should be a shift away from the use of the word “values” when speaking directly to patients toward language such as “what matters to you the most” or “what is most important to you”.
- 1 September 2018
- Published by Taylor & Francis in Patient Preference and Adherence
- Vol. ume 12, 1947-1954
Open Access“I don’t know exactly what you’re referring to”: the challenge of values elicitation in decision making for implantable cardioverter-defibrillators
Purpose: Patients’ values are a key component of patient-centered care and shared decision making in health care organizations. There is limited understanding on how patients’ values guide their health related decision making or how patients understand the concept of values during these processes. This study investigated patients’ understanding of their values in the context of considering the risks/benefits of receiving an implantable cardioverter-defibrillator (ICD). Patients and methods: A qualitative substudy was conducted within a feasibility trial with first-time ICD candidates randomized to receive a patient decision aid or usual care prior to specialist consultation. Semi-structured interviews were conducted with participants post-implantation or post-specialist consultation. Results: Sixteen patients (ten male) aged 47–87 years participated. Of these, ten (62.5%) received the patient decision aid prior to specialist consultation. Findings revealed patients were confused by the word “values” and had difficulty expressing values related to risks/benefits during ICD decision making. When probed, values were conceptualized broadly capturing other factors such as desire to live, good quality of life, family’s views, ICD information, control over decision, and medical authority. Conclusion: This study revealed the difficulty patients considering an ICD had with articulating their values in the context of an ICD health decision and highlighted the challenge to effectively elicit patients’ values within health decisions overall. It is suggested that there should be a shift away from the use of the word “values” when speaking directly to patients toward language such as “what matters to you the most” or “what is most important to you”.