Mohamed Murshid Shamsuddeen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mohamed Murshid Shamsuddeen has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Jin-Hyuk Kim
Convergence Manufacturing System Engineering (Green Process and Energy System Engineering), University of Science & Technology, Daejeon, South Korea
9 shared publications - Changjun Jung
GS Caltex Corporation, Seoul 06141, Korea
2 shared publications Dong-An Cha
Thermal & Fluid System R&D Group, Korea Institute of Industrial Technology, Cheonan, Republic of Korea
2 shared publications- Ji-Hoon Yoon
Dongyang Chemical Pump Company, Paju 10832, Korea
2 shared publications - Kwang-Hee Lee
GS Caltex Corporation, Seoul 06141, Korea
2 shared publications - Mohammad Abu Shahzer
Industrial Technology (Green Process and Energy System Engineering), University of Science & Technology 1 , 217 Gajeong-ro, Yuseong-gu, Daejeon 34113
2 shared publications
Latest Publications
- Open Access
Feasibility study of ultra-low-head hydro turbines for energy extraction from shallow waterways
- Open Access
- 25 March 2024
- Published by The Korean Society for New and Renewable Energy in New & Renewable Energy
- Vol. 20 (1) , 116-125
Parametric Study of a Fixed-blade Runner in an Ultra-low-head Gate Turbine
- 25 March 2024
- Published by The Korean Society for New and Renewable Energy in New & Renewable Energy
- Vol. 20 (1) , 116-125
Open AccessParametric Study of a Fixed-blade Runner in an Ultra-low-head Gate Turbine
- Open Access
Design analysis and optimization of a hydraulic gate turbine for power production from ultra-low head sites
- 1 March 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (3)
Investigation of cavitating vortex rope instabilities and its suppression inside a Francis turbine model with Thoma number variation
Cavitating vortex rope at part load (PL) condition at lower values of the Thoma number (σ) induces severe pressure fluctuation and efficiency reduction in a Francis turbine, which ultimately hinders continuous energy production. Installation of fins at draft tube (DT) can mitigate these instabilities and can safeguard the turbine operation with lower maintenance costs. The effect of fins on hydraulic performance and internal flow physics at PL condition with the variation of σ is examined in the present numerical investigation. For the two extreme opposite values of σ, the flow characteristics are predicted accurately for the turbine with and without fins by conducting transient simulations using ANSYS-CFX. The numerical findings on the structured and unstructured grid points are validated with the experimental results. The turbine's performance remains constant for higher values of Thoma numbers, and as the value decreases, the performance declines. The cavitation vortex rope formation inside the DT with fins is mitigated significantly at the minimum σ, while at the maximum value, the vortex rope with bubble generation is restricted. Compared to the without fin case, the swirl intensity is minimized remarkably (68%) with the presence of fins at the lowest σ. The maximum cavitation rate is manifested by the DT without fins, which is about 60% higher than the DT with fins. At minimum σ, extreme pressure pulsations are induced inside the DT without fins, which are reduced by 43% in the finned draft tube. Therefore, stable energy production is maximized with the installation of fins at both Thoma numbers.
- 1 March 2023
- Published by AIP Publishing in Physics of Fluids
- Vol. 35 (3)
Investigation of cavitating vortex rope instabilities and its suppression inside a Francis turbine model with Thoma number variation
Cavitating vortex rope at part load (PL) condition at lower values of the Thoma number (σ) induces severe pressure fluctuation and efficiency reduction in a Francis turbine, which ultimately hinders continuous energy production. Installation of fins at draft tube (DT) can mitigate these instabilities and can safeguard the turbine operation with lower maintenance costs. The effect of fins on hydraulic performance and internal flow physics at PL condition with the variation of σ is examined in the present numerical investigation. For the two extreme opposite values of σ, the flow characteristics are predicted accurately for the turbine with and without fins by conducting transient simulations using ANSYS-CFX. The numerical findings on the structured and unstructured grid points are validated with the experimental results. The turbine's performance remains constant for higher values of Thoma numbers, and as the value decreases, the performance declines. The cavitation vortex rope formation inside the DT with fins is mitigated significantly at the minimum σ, while at the maximum value, the vortex rope with bubble generation is restricted. Compared to the without fin case, the swirl intensity is minimized remarkably (68%) with the presence of fins at the lowest σ. The maximum cavitation rate is manifested by the DT without fins, which is about 60% higher than the DT with fins. At minimum σ, extreme pressure pulsations are induced inside the DT without fins, which are reduced by 43% in the finned draft tube. Therefore, stable energy production is maximized with the installation of fins at both Thoma numbers.
- Open Access
Effect of an Inducer-Type Guide Vane on Hydraulic Losses at the Inter-Stage Flow Passage of a Multistage Centrifugal Pump
A multistage centrifugal pump was developed for high head and high flow rate applications. A double-suction impeller and a twin-volute were installed at the first stage followed by an impeller, diffuser and return vanes for the next four stages. An initial design feasibility study was conducted using three-dimensional computational fluid dynamics tools to study the performance and the hydraulic losses associated with the design. Substantial losses in head and efficiency were observed at the interface between the first stage volute and the second stage impeller. An inducer-type guide vane (ITGV) was installed at this location to mitigate the losses by reducing the circumferential velocity of the fluid exiting the volute. The ITGV regulated the pre-swirl of the fluid entering the second stage impeller. The pump with and without ITGV is compared at the design flow rate. The pump with ITGV increased the stage head by 63.28% and stage efficiency by 47.17% at the second stage. As a result, the overall performance of the pump increased by 5.78% and 3.94% in head and efficiency, respectively, at the design point. The ITGV has a significant impact on decreasing losses at both design and off-design conditions. An in-depth flow dynamic analysis at the inducer-impeller interface is also presented.
Open AccessEffect of an Inducer-Type Guide Vane on Hydraulic Losses at the Inter-Stage Flow Passage of a Multistage Centrifugal Pump
A multistage centrifugal pump was developed for high head and high flow rate applications. A double-suction impeller and a twin-volute were installed at the first stage followed by an impeller, diffuser and return vanes for the next four stages. An initial design feasibility study was conducted using three-dimensional computational fluid dynamics tools to study the performance and the hydraulic losses associated with the design. Substantial losses in head and efficiency were observed at the interface between the first stage volute and the second stage impeller. An inducer-type guide vane (ITGV) was installed at this location to mitigate the losses by reducing the circumferential velocity of the fluid exiting the volute. The ITGV regulated the pre-swirl of the fluid entering the second stage impeller. The pump with and without ITGV is compared at the design flow rate. The pump with ITGV increased the stage head by 63.28% and stage efficiency by 47.17% at the second stage. As a result, the overall performance of the pump increased by 5.78% and 3.94% in head and efficiency, respectively, at the design point. The ITGV has a significant impact on decreasing losses at both design and off-design conditions. An in-depth flow dynamic analysis at the inducer-impeller interface is also presented.
- Open Access
- 1 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1314
Flow Field Analysis and Feasibility Study of a Multistage Centrifugal Pump Designed for Low-Viscous Fluids
A multistage centrifugal pump is designed for pumping low-viscosity, highly volatile and flammable chemicals, including hydrocarbons, for high head requirements. The five-stage centrifugal pump consists of a double-suction impeller at the first stage followed by a twin volute. The impellers for stages two through five are single-suction impellers followed by diffuser vanes and return channel vanes. The analytical performance is calculated initially in the design stage by applying similarity laws to an existing scaled-down pump model designed for low flow rate applications. The proposed pump design is investigated using computational fluid dynamics tools to study its performance in design and off-design conditions for water as the base fluid. The design feasibility of the centrifugal pump is tested for other fluids, such as water at a high temperature and pressure, diesel and debutanized diesel. The pump design is found to be suitable for a variety of fluids and operating ranges. The losses in the pump are analyzed in each stage at the best efficiency point. The losses in efficiency and head are observed to be higher in the second stage than in other stages. The detailed flow behavior at the second stage is studied to identify the root cause of the losses. Design modifications are recommended to diminish the losses and improve the overall performance of the pump.
- 1 February 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (3) , 1314
Open AccessFlow Field Analysis and Feasibility Study of a Multistage Centrifugal Pump Designed for Low-Viscous Fluids
A multistage centrifugal pump is designed for pumping low-viscosity, highly volatile and flammable chemicals, including hydrocarbons, for high head requirements. The five-stage centrifugal pump consists of a double-suction impeller at the first stage followed by a twin volute. The impellers for stages two through five are single-suction impellers followed by diffuser vanes and return channel vanes. The analytical performance is calculated initially in the design stage by applying similarity laws to an existing scaled-down pump model designed for low flow rate applications. The proposed pump design is investigated using computational fluid dynamics tools to study its performance in design and off-design conditions for water as the base fluid. The design feasibility of the centrifugal pump is tested for other fluids, such as water at a high temperature and pressure, diesel and debutanized diesel. The pump design is found to be suitable for a variety of fluids and operating ranges. The losses in the pump are analyzed in each stage at the best efficiency point. The losses in efficiency and head are observed to be higher in the second stage than in other stages. The detailed flow behavior at the second stage is studied to identify the root cause of the losses. Design modifications are recommended to diminish the losses and improve the overall performance of the pump.
- 1 December 2020
- Published by Elsevier in Renewable Energy
- Vol. 162, 861-876
Unsteady multi-phase cavitation analysis on the effect of anti-cavity fin installed on a Kaplan turbine runner
- 1 December 2020
- Published by Elsevier in Renewable Energy
- Vol. 162, 861-876
Unsteady multi-phase cavitation analysis on the effect of anti-cavity fin installed on a Kaplan turbine runner
- 16 October 2020
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (1) , 111-122
Performance Study of a Hybrid Heat Pump Dryer based on Numerical Analysis and Experimental Set-up
- 16 October 2020
- Published by Springer Nature in Journal of Thermal Science
- Vol. 30 (1) , 111-122
Performance Study of a Hybrid Heat Pump Dryer based on Numerical Analysis and Experimental Set-up
- 25 April 2020
- Published by Taylor & Francis in Drying Technology
- Vol. 39 (15) , 2130-2144
Effects of decompression condition and temperature on drying rate in a hybrid heat pump decompression type dryer used for seafood drying
This study used a laboratory-scale prototype of a hybrid heat pump vacuum dryer to investigate its effect on the drying rate of seafood products. Although seafood products such as oysters and sea cucumbers are the target products, the initial experiments were carried out using wet sponges with the same moisture content as the oysters. The experiments were carried out for ambient pressure, two decompression pressures and three temperature conditions to study the moisture removal capability and power consumption of the dryer prototype. The moisture extraction and specific moisture extraction rate are calculated for each experiment. An optimum operating condition was obtained from the experimental analysis at −0.2 bar and 55 °C. The experiment is again carried out with oysters at the optimum condition. The time consumed for drying 100 kg of oysters decreased considerably in the optimum drying condition without degradation of its color or texture. Additionally, a CFD analysis is carried out to study the internal flow behavior inside the drying chamber. Large recirculation regions and vortices were observed in the return flow duct formed between the drying chamber and tray enclosure. Guide vanes are installed to suppress the flow instabilities. The optimum operating condition along with the stable flow is recommended for industrial-scale design.
- 25 April 2020
- Published by Taylor & Francis in Drying Technology
- Vol. 39 (15) , 2130-2144
Effects of decompression condition and temperature on drying rate in a hybrid heat pump decompression type dryer used for seafood drying
This study used a laboratory-scale prototype of a hybrid heat pump vacuum dryer to investigate its effect on the drying rate of seafood products. Although seafood products such as oysters and sea cucumbers are the target products, the initial experiments were carried out using wet sponges with the same moisture content as the oysters. The experiments were carried out for ambient pressure, two decompression pressures and three temperature conditions to study the moisture removal capability and power consumption of the dryer prototype. The moisture extraction and specific moisture extraction rate are calculated for each experiment. An optimum operating condition was obtained from the experimental analysis at −0.2 bar and 55 °C. The experiment is again carried out with oysters at the optimum condition. The time consumed for drying 100 kg of oysters decreased considerably in the optimum drying condition without degradation of its color or texture. Additionally, a CFD analysis is carried out to study the internal flow behavior inside the drying chamber. Large recirculation regions and vortices were observed in the return flow duct formed between the drying chamber and tray enclosure. Guide vanes are installed to suppress the flow instabilities. The optimum operating condition along with the stable flow is recommended for industrial-scale design.