WWWeicheng Wang

Weicheng Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Weicheng Wang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Frequency Estimation and Noise Reduction in Homodyne Grating Interferometer based on Third-Order Generalized Integrator-Frequency Locked Loop with Damping Ratio Adaptation

    by Weicheng Wang, Siyu Jin, Zhaowu Liu, Xin’gE Qian, Shuai Pi, Wenhao Li, Jun Lin

    A phase-locked loop (PLL)-based subdivision module can provide distance and velocity information to the homodyne grating interferometer integrated with a servo control system. However, the received sinusoidal signal pair from the homodyne grating interferometer is degraded by considerable low-frequency noise, harmonic components, and white noise, limiting displacement measurement accuracy. In this paper, a fast signal filtering method is proposed for homodyne grating interferometer based on the combination of two third-order generalized integrators (TOGIs) and a frequency-locked loop (FLL). FLL is designed with damping ratio adaption to obtain high-accuracy estimation of time-varying frequency of the homodyne grating interferometer signal, while two TOGIs are employed as frequency-adaptive band-pass filters using the FLL estimated frequency as the center frequency. Therefore, the proposed method enables accurate tracking of the fundamental components within the homodyne grating interferometer signals, thereby effectively reducing noise. The performance of the proposed method is evaluated through simulations and physical experiments under various conditions, including frequency step changes, white noise, low-frequency noise, harmonics, and sinusoidal motions covering constant velocity and acceleration regimes. The results demonstrated that the proposed method generally outperformed other methods, namely SOGI-FLL, SOGI-FLLWPF and SOGI-FLL-WIF. This study contributes to enabling more accurate and reliable displacement measurement using homodyne grating interferometers.

  • A Real-Time Determination Method for Homodyne Grating Interferometer Signal Nonlinear Error Based on Duty Cycle Measurement of States

    by Weicheng Wang, Jun Lin, Siyu Jin, Yu Bai, Lin Liu, Zhaowu Liu, Yishu Sun, Wenhao Li

    Nonlinear error is a serious obstruction for increasing the resolution and accuracy of the homodyne grating interferometer. To eliminate the nonlinear error, this paper presents a real-time method to determine the nonlinear error in the homodyne grating interferometer signal. Two thresholds separate the signal into four states, the duty cycle of each state will be measured and used to determine the nonlinear error parameters separately. The method proposed was implemented using MATLAB and an FPGA for the determination process. The simulation and experiment results indicated that the proposed method is easier to achieve with similar accuracy and precision compared with the methods based on the fitting algorithm. The nonlinear error could be reduced to about 37 nm from 79 nm in a 100 μm test, similar to the fitting algorithms.


  • Open Access

    Design of a Differential Low-Noise Amplifier Using the JFET IF3602 to Improve TEM Receiver

    by Shengjie Wang, Yuqi Zhao, Yishu Sun, Weicheng Wang, Jian Chen, Yang Zhang

    The observed data of transient electromagnetic (TEM) systems is often contaminated by various noises. Even after stacking averages or applying various denoising algorithms, the interference of the system noise floor cannot be eliminated fundamentally, which limits the survey capability and detection efficiency of TEM. To improve the noise performance of the TEM receiver, we have designed a low-noise amplifier using the current source long-tail differential structure and JFET IF3602 through analyzing the power spectrum characteristics of the TEM forward response. By the designed circuit structure, the JFET operating point is easy to set up. The adverse effect on the JFET differential structure by JFET performance differences is also weakened. After establishing the noise model and optimizing the parameters, the designed low-noise differential amplifier has a noise level of 0.60nV/Hz, which increases the number of effective data 2.6 times compared with the LT1028 amplifier.


  • Open Access

    Optimization Method of Adaptive Backoff and Duty Cycle for S-MAC Protocol in Wireless Sensor Networks

    by Weicheng Wang, Jianpo Li, Yang Lu, Chuang Liu

    As a matter of fact that the network traffic has a great influence on the binary exponential backoff mechanism, duty cycle mechanism, and fixed transmission power mechanism adopted by the Sensor Medium Access Control (S-MAC) protocol. The paper proposes an Adaptive Backoff and Duty Cycle for S-MAC protocol (ABDC-SMAC). In the backoff mechanism, considering the failure times of channel competitions, the length of buffer queue, and the node residual energy across the board, a cross-control backoff mechanism is proposed. In the duty cycle mechanism, the network traffic is judged by the average network flow factor. Based on the average network flow factor, the value of duty cycle can change around its initial value. In the power control mechanism, the minimum transmission power can be obtained by the Friis formula. At the same time, the exponential formula following the change of network traffic is selected and multiplied by the minimum transmission formula. The simulation results show that the performance of proposed ABDC-SMAC protocol is improved obviously on energy consumption and transmission delay.


  • Open Access

    An Intelligent Fault Diagnosis Method for Open-Circuit Faults in Power-Electronics Energy Conversion System

    by Wei-Cheng Wang, Lei Kou, Quan-De Yuan, Jia-Ning Zhou, Chuang Liu, Guo-Wei Cai

    Applying the fault diagnosis techniques to power electronic equipments is beneficial to improve the stability and reliability of renewable energy system, because power electronic equipments are a key component of renewable energy system that largely defines their performance. This paper presents a novel intelligent fault diagnosis method for a three-phase power-electronics energy conversion system based on knowledge-based and data-driven methods. Firstly, the three-phase AC currents of the power-electronics energy conversion system are collected and used to analyze. Secondly, the feature transformation, a knowledge-based method, is utilized to preprocess the fault data. After feature transformation, the slopes of current trajectories (transformed features) are not affected by different loads. And then random forests algorithms (RFs), a data-driven method, are adopted to train the fault diagnosis classifier with the processed fault data. Finally, the proposed method is implemented online on an actual three-phase PWM rectifier platform. The results show that the proposed fault diagnosis method can successfully detect and locate the open-circuit faults in IGBTs of the three-phase PWM rectifier. In addition, the proposed method is suitable for most of power-electronics energy conversion systems.


  • P4-Enabled Bandwidth Management

    by Yan-Wei Chen, Li-Hsing Yen, Wei-Cheng Wang, Cheng-An Chuang, Yu-Shen Liu, Chien-Chao Tseng