Zhaowu Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhaowu Liu has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Wenhao Li
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
4 shared publications - Lin Liu
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
3 shared publications - Siyu Jin
Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun, China
3 shared publications - Jun Lin
Jilin University
2 shared publications - Weicheng Wang
College of Instrumentation and Electrical Engineering, State Key Laboratory of Deep Earth Exploration and Imaging, Jilin University, Changchun, China
2 shared publications - Peng Zeng
Changchun Institute of Optics, Fine Mechanics and Physics, University of Chinese Academy of Sciences, Changchun, China
1 shared publication
Latest Publications
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Suppression Method for Stochastic Line Errors in Grating Interferometers Based on Spatial Wavefront Phase Analysis Theory
Grating interferometers have been extensively adopted in modern precision manufacturing industries. Diffraction gratings are the core components of grating interferometric displacement measurement systems. Notably, stochastic line errors of the grating introduce additional phase errors into the phase information of diffracted beams, ultimately degrading measurement precision. To eliminate the interference from stochastic line errors, this study establishes the spatial wavefront phase analysis theory (SWPAT). The adverse effects of stochastic line errors on the phase of diffracted beams are investigated, and a method of using large-diameter beams is proposed to suppress these errors. To validate this method, a heterodyne Littrow grating interferometric experimental setup is built, and controlled experiments with four different beam diameters are designed using the control variable method. Experimental results demonstrate that when the measurement beam diameter increases from 1 to 4 mm, the maximum displacement error is reduced by 34.3%, and the $3\sigma $ value is reduced by 45.9%, thus verifying the correctness of SWPAT. This work enriches the theoretical framework for error compensation in grating interferometric displacement measurement systems and holds significant importance for improving displacement measurement precision.
- 4 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Suppression Method for Stochastic Line Errors in Grating Interferometers Based on Spatial Wavefront Phase Analysis Theory
Grating interferometers have been extensively adopted in modern precision manufacturing industries. Diffraction gratings are the core components of grating interferometric displacement measurement systems. Notably, stochastic line errors of the grating introduce additional phase errors into the phase information of diffracted beams, ultimately degrading measurement precision. To eliminate the interference from stochastic line errors, this study establishes the spatial wavefront phase analysis theory (SWPAT). The adverse effects of stochastic line errors on the phase of diffracted beams are investigated, and a method of using large-diameter beams is proposed to suppress these errors. To validate this method, a heterodyne Littrow grating interferometric experimental setup is built, and controlled experiments with four different beam diameters are designed using the control variable method. Experimental results demonstrate that when the measurement beam diameter increases from 1 to 4 mm, the maximum displacement error is reduced by 34.3%, and the $3\sigma $ value is reduced by 45.9%, thus verifying the correctness of SWPAT. This work enriches the theoretical framework for error compensation in grating interferometric displacement measurement systems and holds significant importance for improving displacement measurement precision.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9534417
Spatiotemporal Superposition Two-Color Heterodyne Laser Displacement Interferometry Method for Suppressing the Random Error Amplification Effect
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9534417
Spatiotemporal Superposition Two-Color Heterodyne Laser Displacement Interferometry Method for Suppressing the Random Error Amplification Effect
- Open Access
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 38 (9) , 571-574
Absolute Optical Encoder Using a Reference–Incremental Fused Signal
This letter proposes an absolute positioning method for distance encoding by fusing reference signals with incremental signals. Reference marks with extinction characteristics are embedded in a holographic grating with a high line density. When the reading head scans over these reference marks, the corresponding scale signal amplitude is modulated. The distance is encoded through intensity modulation of the scale signal, achieving absolute positioning with a single reading head and a single code track. A fused signal model based on a Gaussian detection beam is established, and the relationship between the modulation depth of the reference signal and both the Gaussian beam diameter and reference mark width is simulated and analyzed. A prototype system is built to validate the proposed model under$150\mu $ m and$250\mu $ m mark widths. An algorithm combining curve fitting, interpolation optimization, and dual-peak averaging is used to identify and extract the reference mark positions. For ten experimental data sets, the repeat positioning accuracy of the mark spacing is$0.15\mu $ m.- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 38 (9) , 571-574
Open AccessAbsolute Optical Encoder Using a Reference–Incremental Fused Signal
This letter proposes an absolute positioning method for distance encoding by fusing reference signals with incremental signals. Reference marks with extinction characteristics are embedded in a holographic grating with a high line density. When the reading head scans over these reference marks, the corresponding scale signal amplitude is modulated. The distance is encoded through intensity modulation of the scale signal, achieving absolute positioning with a single reading head and a single code track. A fused signal model based on a Gaussian detection beam is established, and the relationship between the modulation depth of the reference signal and both the Gaussian beam diameter and reference mark width is simulated and analyzed. A prototype system is built to validate the proposed model under$150\mu $ m and$250\mu $ m mark widths. An algorithm combining curve fitting, interpolation optimization, and dual-peak averaging is used to identify and extract the reference mark positions. For ten experimental data sets, the repeat positioning accuracy of the mark spacing is$0.15\mu $ m. - 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Frequency Estimation and Noise Reduction in Homodyne Grating Interferometer based on Third-Order Generalized Integrator-Frequency Locked Loop with Damping Ratio Adaptation
A phase-locked loop (PLL)-based subdivision module can provide distance and velocity information to the homodyne grating interferometer integrated with a servo control system. However, the received sinusoidal signal pair from the homodyne grating interferometer is degraded by considerable low-frequency noise, harmonic components, and white noise, limiting displacement measurement accuracy. In this paper, a fast signal filtering method is proposed for homodyne grating interferometer based on the combination of two third-order generalized integrators (TOGIs) and a frequency-locked loop (FLL). FLL is designed with damping ratio adaption to obtain high-accuracy estimation of time-varying frequency of the homodyne grating interferometer signal, while two TOGIs are employed as frequency-adaptive band-pass filters using the FLL estimated frequency as the center frequency. Therefore, the proposed method enables accurate tracking of the fundamental components within the homodyne grating interferometer signals, thereby effectively reducing noise. The performance of the proposed method is evaluated through simulations and physical experiments under various conditions, including frequency step changes, white noise, low-frequency noise, harmonics, and sinusoidal motions covering constant velocity and acceleration regimes. The results demonstrated that the proposed method generally outperformed other methods, namely SOGI-FLL, SOGI-FLLWPF and SOGI-FLL-WIF. This study contributes to enabling more accurate and reliable displacement measurement using homodyne grating interferometers.
- 25 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. PP (00189456) , 1
Frequency Estimation and Noise Reduction in Homodyne Grating Interferometer based on Third-Order Generalized Integrator-Frequency Locked Loop with Damping Ratio Adaptation
A phase-locked loop (PLL)-based subdivision module can provide distance and velocity information to the homodyne grating interferometer integrated with a servo control system. However, the received sinusoidal signal pair from the homodyne grating interferometer is degraded by considerable low-frequency noise, harmonic components, and white noise, limiting displacement measurement accuracy. In this paper, a fast signal filtering method is proposed for homodyne grating interferometer based on the combination of two third-order generalized integrators (TOGIs) and a frequency-locked loop (FLL). FLL is designed with damping ratio adaption to obtain high-accuracy estimation of time-varying frequency of the homodyne grating interferometer signal, while two TOGIs are employed as frequency-adaptive band-pass filters using the FLL estimated frequency as the center frequency. Therefore, the proposed method enables accurate tracking of the fundamental components within the homodyne grating interferometer signals, thereby effectively reducing noise. The performance of the proposed method is evaluated through simulations and physical experiments under various conditions, including frequency step changes, white noise, low-frequency noise, harmonics, and sinusoidal motions covering constant velocity and acceleration regimes. The results demonstrated that the proposed method generally outperformed other methods, namely SOGI-FLL, SOGI-FLLWPF and SOGI-FLL-WIF. This study contributes to enabling more accurate and reliable displacement measurement using homodyne grating interferometers.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
A Real-Time Determination Method for Homodyne Grating Interferometer Signal Nonlinear Error Based on Duty Cycle Measurement of States
Nonlinear error is a serious obstruction for increasing the resolution and accuracy of the homodyne grating interferometer. To eliminate the nonlinear error, this paper presents a real-time method to determine the nonlinear error in the homodyne grating interferometer signal. Two thresholds separate the signal into four states, the duty cycle of each state will be measured and used to determine the nonlinear error parameters separately. The method proposed was implemented using MATLAB and an FPGA for the determination process. The simulation and experiment results indicated that the proposed method is easier to achieve with similar accuracy and precision compared with the methods based on the fitting algorithm. The nonlinear error could be reduced to about 37 nm from 79 nm in a 100 μm test, similar to the fitting algorithms.
- 28 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-8
A Real-Time Determination Method for Homodyne Grating Interferometer Signal Nonlinear Error Based on Duty Cycle Measurement of States
Nonlinear error is a serious obstruction for increasing the resolution and accuracy of the homodyne grating interferometer. To eliminate the nonlinear error, this paper presents a real-time method to determine the nonlinear error in the homodyne grating interferometer signal. Two thresholds separate the signal into four states, the duty cycle of each state will be measured and used to determine the nonlinear error parameters separately. The method proposed was implemented using MATLAB and an FPGA for the determination process. The simulation and experiment results indicated that the proposed method is easier to achieve with similar accuracy and precision compared with the methods based on the fitting algorithm. The nonlinear error could be reduced to about 37 nm from 79 nm in a 100 μm test, similar to the fitting algorithms.