Wallisson C. Nogueira has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Jesus Maria Lopez Lezama
Research Group on Efficient Energy Management (GIMEL), Department of Electrical Engineering, Universidad de Antioquia (UdeA), Medellín 050010, Colombia
2 shared publications - Lina Paola Garcés Negrete
Electrical, Mechanical and Computer Engineering School, Federal University of Goiás (UFG), Av. Universitária No. 1488, Goiânia 74605-010, Brazil
2 shared publications
Latest Publications
- Open Access
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5171
Optimal Allocation and Sizing of Distributed Generation Using Interval Power Flow
Modern distribution systems and microgrids must deal with high levels of uncertainty in their planning and operation. These uncertainties are mainly due to variations in loads and distributed generation (DG) introduced by new technologies. This scenario brings new challenges to planners and system operators that need new tools to perform more assertive analyses of the grid state. This paper presents an optimization methodology capable of considering uncertainties in the optimal allocation and sizing problem of DG in distribution networks. The proposed methodology uses an interval power flow (IPF) that adds uncertainties to the combinatorial optimization problem in charge of sizing and allocating DG units in the network. Two metaheuristics were implemented for comparative purposes, namely, symbiotic organism search (SOS) and particle swarm optimization (PSO). The proposed methodology was implemented in Python® using as benchmark distribution systems the IEEE 33-bus and IEEE 69-bus test distribution networks. The objective function consists of minimizing technical losses and regulating network voltage levels. The results obtained from the proposed IPF on the tested networks are compatible with those obtained by the PPF, thus evidencing the robustness and applicability of the proposed method. For the solution of the optimization problem, the SOS metaheuristic proved to be robust, since it was able to find the best solutions (lowest losses) while keeping voltage levels within the predetermined range. On the other hand, the PSO metaheuristic showed less satisfactory results, since for all test systems, the solutions found were of lower quality than the ones found by the SOS.
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5171
Open AccessOptimal Allocation and Sizing of Distributed Generation Using Interval Power Flow
Modern distribution systems and microgrids must deal with high levels of uncertainty in their planning and operation. These uncertainties are mainly due to variations in loads and distributed generation (DG) introduced by new technologies. This scenario brings new challenges to planners and system operators that need new tools to perform more assertive analyses of the grid state. This paper presents an optimization methodology capable of considering uncertainties in the optimal allocation and sizing problem of DG in distribution networks. The proposed methodology uses an interval power flow (IPF) that adds uncertainties to the combinatorial optimization problem in charge of sizing and allocating DG units in the network. Two metaheuristics were implemented for comparative purposes, namely, symbiotic organism search (SOS) and particle swarm optimization (PSO). The proposed methodology was implemented in Python® using as benchmark distribution systems the IEEE 33-bus and IEEE 69-bus test distribution networks. The objective function consists of minimizing technical losses and regulating network voltage levels. The results obtained from the proposed IPF on the tested networks are compatible with those obtained by the PPF, thus evidencing the robustness and applicability of the proposed method. For the solution of the optimization problem, the SOS metaheuristic proved to be robust, since it was able to find the best solutions (lowest losses) while keeping voltage levels within the predetermined range. On the other hand, the PSO metaheuristic showed less satisfactory results, since for all test systems, the solutions found were of lower quality than the ones found by the SOS.
- Open Access
Interval Load Flow for Uncertainty Consideration in Power Systems Analysis
Modern power systems must deal with a greater degree of uncertainty in power flow calculation due to variations in load and generation introduced by new technologies. This scenario poses new challenges to power system operators which require new tools for an accurate assessment of the system state. This paper presents an interval load flow (ILF) approach for dealing with uncertainty in power system analysis. A probabilistic load flow (PLF), based on Monte Carlo Simulation (MCS), was also implemented for comparative purposes. The ILF and PLF are used to estimate the network states. Both methods were implemented in Python® using the IEEE 34-bus, IEEE 69-bus and 192-bus Brazilian distribution system. The results with the proposed ILF on the aforementioned benchmark test systems proved to be compatible with that of the MCS, evidencing the robustness and applicability of the proposed approach.
Open AccessInterval Load Flow for Uncertainty Consideration in Power Systems Analysis
Modern power systems must deal with a greater degree of uncertainty in power flow calculation due to variations in load and generation introduced by new technologies. This scenario poses new challenges to power system operators which require new tools for an accurate assessment of the system state. This paper presents an interval load flow (ILF) approach for dealing with uncertainty in power system analysis. A probabilistic load flow (PLF), based on Monte Carlo Simulation (MCS), was also implemented for comparative purposes. The ILF and PLF are used to estimate the network states. Both methods were implemented in Python® using the IEEE 34-bus, IEEE 69-bus and 192-bus Brazilian distribution system. The results with the proposed ILF on the aforementioned benchmark test systems proved to be compatible with that of the MCS, evidencing the robustness and applicability of the proposed approach.