Lina Paola Garcés Negrete
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lina Paola Garcés Negrete has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Jesus Maria Lopez Lezama
Research Group on Efficient Energy Management (GIMEL), Department of Electrical Engineering, Universidad de Antioquia (UdeA), Medellín 050010, Colombia
7 shared publications - Nicolás Muñoz-Galeano
Research Group on Efficient Energy Management (GIMEL), Department of Electrical Engineering, Universidad de Antioquia (UdeA), Medellín 050010, Colombia
4 shared publications - Gelson Antônio Andrêa Brigatto
Electrical, Mechanical and Computer Engineering School, Federal University of Goias, Av. Universitária, No. 1488, Goiania 74605-010, Brazil
3 shared publications - Paulo S. Zanin
Electrical, Mechanical and Computer Engineering School, Universidade Federal de Goiás, Av. Universitária, No. 1488, Setor Leste Universitário, Goiânia 74605-010, Brazil
2 shared publications - Wallisson C. Nogueira
Electrical, Mechanical and Computer Engineering School, Federal University of Goiás, Av. Universitária No. 1488, Goiânia 74605-010, Brazil
2 shared publications - André Luiz Amorim da Fonseca
Department of Electrical Engineering, Federal Institute of Education, Science and Technology of Mato Grosso, Cuiaba 78144-424, Brazil
1 shared publication
Latest Publications
- Top Cited PapersOpen Access
Strategies to Mitigate Reverse Power Flow in Distribution Networks with High Penetration of Solar Photovoltaic Generation
The power industry has undergone significant recent changes due to the growing demand for a cleaner and more sustainable energy mix. In this context, the Brazilian government began encouraging distributed generation (DG), making photovoltaic generation a strong trend in the country. However, the expansion of DG may cause negative impacts on the grid, such as reverse power flow (RPF) and overvoltages, which motivates research aimed at mitigating these effects. This study proposes strategies to mitigate RPF in distribution networks with high penetration of photovoltaic generation and evaluates their impacts on the electrical system. Three strategies were analyzed: a battery energy storage system (BESS), a control mechanism using a Grid Zero inverter, and PV Curtailment. The strategies were implemented in OpenDSS on a real distribution network located in São Paulo, Brazil. The assessment involved analyzing power flow in critical transformers and at the substation, as well as monitoring bus voltages and network energy losses. The quantitative results demonstrate that BESS allocation was the superior strategy, reducing technical losses by 61.3% and fully mitigating reverse power flow under steady-state conditions. The Grid Zero inverter eliminated power injection into the grid; however, it increased substation dependency by 59% compared to the baseline scenario. PV curtailment, although achieving the smallest reduction in RPF, proved to be the most effective technique for power quality, limiting the average voltage rise to 0.7%.
Top Cited PapersOpen AccessStrategies to Mitigate Reverse Power Flow in Distribution Networks with High Penetration of Solar Photovoltaic Generation
The power industry has undergone significant recent changes due to the growing demand for a cleaner and more sustainable energy mix. In this context, the Brazilian government began encouraging distributed generation (DG), making photovoltaic generation a strong trend in the country. However, the expansion of DG may cause negative impacts on the grid, such as reverse power flow (RPF) and overvoltages, which motivates research aimed at mitigating these effects. This study proposes strategies to mitigate RPF in distribution networks with high penetration of photovoltaic generation and evaluates their impacts on the electrical system. Three strategies were analyzed: a battery energy storage system (BESS), a control mechanism using a Grid Zero inverter, and PV Curtailment. The strategies were implemented in OpenDSS on a real distribution network located in São Paulo, Brazil. The assessment involved analyzing power flow in critical transformers and at the substation, as well as monitoring bus voltages and network energy losses. The quantitative results demonstrate that BESS allocation was the superior strategy, reducing technical losses by 61.3% and fully mitigating reverse power flow under steady-state conditions. The Grid Zero inverter eliminated power injection into the grid; however, it increased substation dependency by 59% compared to the baseline scenario. PV curtailment, although achieving the smallest reduction in RPF, proved to be the most effective technique for power quality, limiting the average voltage rise to 0.7%.
- Open Access
Comparative Review of Reactive Power Estimation Techniques for Voltage Restoration
With the focus on the growing concern of voltage instability and its inherent risks connected to blackouts, this study addresses the importance of Volt/VAR control (VVC) in maintaining voltage stability, optimizing power factor, and reducing losses. As such, this scientific article presents a review of the methodologies used to estimate the quantity of reactive power required to restore voltage in power grids. Although reviews exist on classical methods, optimization, and machine learning, a study unifying these approaches is lacking. This gap hinders an integrated comparison of methodologies and constitutes the main motivation for this study in 2025. This absence of a consolidated and up-to-date review limits both academic progress and practical decision-making in modern power systems, especially as DER penetration accelerates. This research was conducted using the Scopus database through the selection of articles that address reactive power estimation methods. The results indicate that traditional numerical and optimization methods, although accurate, demonstrate high computational costs for real-time application. In contrast, techniques such as Deep Reinforcement Learning (DRL) and hybrid models show greater potential for dealing with uncertainties and dynamic topologies. The conclusion reached is that the solution for reactive power management lies in hybrid approaches, which combine machine learning with numerical methods, supported by an intelligent and robust data infrastructure. The comparative analysis shows that numerical methods offer high precision but are computationally expensive for real-time use; optimization techniques provide good robustness but depend on detailed models that are sensitive to system conditions; and machine learning-based approaches offer greater adaptability under uncertainty, although they require large datasets and careful training. Given these complementary limitations, hybrid approaches emerge as the most promising alternative, combining the reliability of classical methods with the flexibility of intelligent models, especially in smart grids with dynamic topologies and high penetration of Distributed Energy Resources (DERs).
Open AccessComparative Review of Reactive Power Estimation Techniques for Voltage Restoration
With the focus on the growing concern of voltage instability and its inherent risks connected to blackouts, this study addresses the importance of Volt/VAR control (VVC) in maintaining voltage stability, optimizing power factor, and reducing losses. As such, this scientific article presents a review of the methodologies used to estimate the quantity of reactive power required to restore voltage in power grids. Although reviews exist on classical methods, optimization, and machine learning, a study unifying these approaches is lacking. This gap hinders an integrated comparison of methodologies and constitutes the main motivation for this study in 2025. This absence of a consolidated and up-to-date review limits both academic progress and practical decision-making in modern power systems, especially as DER penetration accelerates. This research was conducted using the Scopus database through the selection of articles that address reactive power estimation methods. The results indicate that traditional numerical and optimization methods, although accurate, demonstrate high computational costs for real-time application. In contrast, techniques such as Deep Reinforcement Learning (DRL) and hybrid models show greater potential for dealing with uncertainties and dynamic topologies. The conclusion reached is that the solution for reactive power management lies in hybrid approaches, which combine machine learning with numerical methods, supported by an intelligent and robust data infrastructure. The comparative analysis shows that numerical methods offer high precision but are computationally expensive for real-time use; optimization techniques provide good robustness but depend on detailed models that are sensitive to system conditions; and machine learning-based approaches offer greater adaptability under uncertainty, although they require large datasets and careful training. Given these complementary limitations, hybrid approaches emerge as the most promising alternative, combining the reliability of classical methods with the flexibility of intelligent models, especially in smart grids with dynamic topologies and high penetration of Distributed Energy Resources (DERs).
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 148713-148731
Operational Impacts of Ignoring Temperature-Driven Demand–PV Correlation in Isolated Power Systems
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 14, 148713-148731
Open AccessOperational Impacts of Ignoring Temperature-Driven Demand–PV Correlation in Isolated Power Systems
- Open Access
Optimizing Photovoltaic Generation Placement and Sizing Using Evolutionary Strategies Under Spatial Constraints
This study presents a methodology for optimizing the placement and sizing of photovoltaic generation in power distribution networks. In addition to technical and budgetary constraints, the proposed approach incorporates georeferenced spatial restrictions to determine the optimal location and capacity of the generation units. These spatial constraints are not commonly considered in similar studies, which make them the main contribution in the proposed methodology. The proposed approach is divided into three stages and utilizes simulations in OpenDSS and QGIS, which employ optimization strategies such as the Hybrid Evolutionary Strategy and the Hybrid Genetic Algorithm. The methodology was evaluated on the IEEE 34-bus system and a real feeder. The results demonstrate the effectiveness of the proposed approach, which achieves significant reductions in system losses—14.48% for the IEEE 34-bus system and 14.08% for the real feeder—while also improving voltage profiles. These findings validate its applicability in the efficient and sustainable planning of power distribution systems.
Open AccessOptimizing Photovoltaic Generation Placement and Sizing Using Evolutionary Strategies Under Spatial Constraints
This study presents a methodology for optimizing the placement and sizing of photovoltaic generation in power distribution networks. In addition to technical and budgetary constraints, the proposed approach incorporates georeferenced spatial restrictions to determine the optimal location and capacity of the generation units. These spatial constraints are not commonly considered in similar studies, which make them the main contribution in the proposed methodology. The proposed approach is divided into three stages and utilizes simulations in OpenDSS and QGIS, which employ optimization strategies such as the Hybrid Evolutionary Strategy and the Hybrid Genetic Algorithm. The methodology was evaluated on the IEEE 34-bus system and a real feeder. The results demonstrate the effectiveness of the proposed approach, which achieves significant reductions in system losses—14.48% for the IEEE 34-bus system and 14.08% for the real feeder—while also improving voltage profiles. These findings validate its applicability in the efficient and sustainable planning of power distribution systems.
- Open Access
Comparative Analysis of Protection Schemes for Shunt Reactors: Addressing Turn-to-Ground and Turn Faults with Parametric Sensitivity and Transient Evaluations
In electrical power systems, shunt reactors control excess reactive power, keeping voltage levels within acceptable limits. As shunt reactors play a crucial role in the operation of electrical systems, it is essential to ensure the use of modern and fast protection schemes for these devices. Furthermore, protection functions must be capable of identifying various fault conditions, including critical operating situations such as turn-to-ground and turn faults, involving only a few short-circuited turns. This paper proposes a comparative evaluation of protection schemes commonly employed by manufacturers to meet the requirements of different grid codes. Thus, the investigation encompasses restricted earth fault, directional, differential, and distance functions. The latter is typically cited as a backup protection function. To support the analyses conducted, an electrical power system with shunt compensation was modeled in the ATPDraw software version 7.3. Through this platform, various internal fault conditions were simulated, encompassing turn-to-ground and turn faults. This facilitated the analysis of the influence of parameters such as the leakage factor value and the number of short-circuited turns. Additionally, external fault conditions were evaluated, including cases involving Current Transformer (CT) saturation.
Open AccessComparative Analysis of Protection Schemes for Shunt Reactors: Addressing Turn-to-Ground and Turn Faults with Parametric Sensitivity and Transient Evaluations
In electrical power systems, shunt reactors control excess reactive power, keeping voltage levels within acceptable limits. As shunt reactors play a crucial role in the operation of electrical systems, it is essential to ensure the use of modern and fast protection schemes for these devices. Furthermore, protection functions must be capable of identifying various fault conditions, including critical operating situations such as turn-to-ground and turn faults, involving only a few short-circuited turns. This paper proposes a comparative evaluation of protection schemes commonly employed by manufacturers to meet the requirements of different grid codes. Thus, the investigation encompasses restricted earth fault, directional, differential, and distance functions. The latter is typically cited as a backup protection function. To support the analyses conducted, an electrical power system with shunt compensation was modeled in the ATPDraw software version 7.3. Through this platform, various internal fault conditions were simulated, encompassing turn-to-ground and turn faults. This facilitated the analysis of the influence of parameters such as the leakage factor value and the number of short-circuited turns. Additionally, external fault conditions were evaluated, including cases involving Current Transformer (CT) saturation.
- Open Access
- 16 November 2023
- Published by Seminar on Power Electronics and Control - SEPOC
Avaliação do Impacto da Conexão de Recursos Energéticos Distribuídos na Rede de Distribuição
- 16 November 2023
- Published by Seminar on Power Electronics and Control - SEPOC
Open AccessAvaliação do Impacto da Conexão de Recursos Energéticos Distribuídos na Rede de Distribuição
- Open Access
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5171
Optimal Allocation and Sizing of Distributed Generation Using Interval Power Flow
Modern distribution systems and microgrids must deal with high levels of uncertainty in their planning and operation. These uncertainties are mainly due to variations in loads and distributed generation (DG) introduced by new technologies. This scenario brings new challenges to planners and system operators that need new tools to perform more assertive analyses of the grid state. This paper presents an optimization methodology capable of considering uncertainties in the optimal allocation and sizing problem of DG in distribution networks. The proposed methodology uses an interval power flow (IPF) that adds uncertainties to the combinatorial optimization problem in charge of sizing and allocating DG units in the network. Two metaheuristics were implemented for comparative purposes, namely, symbiotic organism search (SOS) and particle swarm optimization (PSO). The proposed methodology was implemented in Python® using as benchmark distribution systems the IEEE 33-bus and IEEE 69-bus test distribution networks. The objective function consists of minimizing technical losses and regulating network voltage levels. The results obtained from the proposed IPF on the tested networks are compatible with those obtained by the PPF, thus evidencing the robustness and applicability of the proposed method. For the solution of the optimization problem, the SOS metaheuristic proved to be robust, since it was able to find the best solutions (lowest losses) while keeping voltage levels within the predetermined range. On the other hand, the PSO metaheuristic showed less satisfactory results, since for all test systems, the solutions found were of lower quality than the ones found by the SOS.
- 14 March 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (6) , 5171
Open AccessOptimal Allocation and Sizing of Distributed Generation Using Interval Power Flow
Modern distribution systems and microgrids must deal with high levels of uncertainty in their planning and operation. These uncertainties are mainly due to variations in loads and distributed generation (DG) introduced by new technologies. This scenario brings new challenges to planners and system operators that need new tools to perform more assertive analyses of the grid state. This paper presents an optimization methodology capable of considering uncertainties in the optimal allocation and sizing problem of DG in distribution networks. The proposed methodology uses an interval power flow (IPF) that adds uncertainties to the combinatorial optimization problem in charge of sizing and allocating DG units in the network. Two metaheuristics were implemented for comparative purposes, namely, symbiotic organism search (SOS) and particle swarm optimization (PSO). The proposed methodology was implemented in Python® using as benchmark distribution systems the IEEE 33-bus and IEEE 69-bus test distribution networks. The objective function consists of minimizing technical losses and regulating network voltage levels. The results obtained from the proposed IPF on the tested networks are compatible with those obtained by the PPF, thus evidencing the robustness and applicability of the proposed method. For the solution of the optimization problem, the SOS metaheuristic proved to be robust, since it was able to find the best solutions (lowest losses) while keeping voltage levels within the predetermined range. On the other hand, the PSO metaheuristic showed less satisfactory results, since for all test systems, the solutions found were of lower quality than the ones found by the SOS.
- Open Access
A Novel Solution Method for the Distribution Network Reconfiguration Problem Based on a Search Mechanism Enhancement of the Improved Harmony Search Algorithm
This paper addresses the problem of Distribution Systems Reconfiguration (DSR), which consists of finding the state of switching devices (open or closed) in a given distribution network, aiming to minimize active power loses. DSR is modeled as a mixed-integer non-linear optimization problem, in which the integer variables represent the state of the switches, and the continuous variables represent the power flowing through the branches. Given the multi-modal and non-convex nature of the problem, an improved harmony search (IHS) algorithm is proposed to solve the DSR problem. The main novelty of this approach is the inclusion of a Path Relinking phase which accelerates convergence of the DSR problem. Several tests were carried out in four benchmark distribution systems, evidencing the effectiveness and applicability of the proposed approach.
Open AccessA Novel Solution Method for the Distribution Network Reconfiguration Problem Based on a Search Mechanism Enhancement of the Improved Harmony Search Algorithm
This paper addresses the problem of Distribution Systems Reconfiguration (DSR), which consists of finding the state of switching devices (open or closed) in a given distribution network, aiming to minimize active power loses. DSR is modeled as a mixed-integer non-linear optimization problem, in which the integer variables represent the state of the switches, and the continuous variables represent the power flowing through the branches. Given the multi-modal and non-convex nature of the problem, an improved harmony search (IHS) algorithm is proposed to solve the DSR problem. The main novelty of this approach is the inclusion of a Path Relinking phase which accelerates convergence of the DSR problem. Several tests were carried out in four benchmark distribution systems, evidencing the effectiveness and applicability of the proposed approach.
- Open Access
- 13 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7442
A Multi-Objective Hybrid Genetic Algorithm for Sizing and Siting of Renewable Distributed Generation
Renewable generation has been addressed in several aspects but it still represents a new paradigm for the expansion of the electricity supply. This paper aims to propose a new model for the sizing and siting problem of distributed generation (DG), based on renewable sources and considering three main aspects: technical, from the distribution utility viewpoint; economical, from the DG owner’s viewpoint, and environmental, from a sustainability perspective. A multi-objective Genetic Algorithm and the Maximin metric are implemented to obtain optimal Pareto sets; also, three decision criteria, considering the concept of preference, are applied to select a final solution from Pareto sets. Case-studies are carried out in medium voltage systems: the 69-bus distribution test system, known from literature, and a 918-bus Brazilian distribution system. Diversity of alternatives in the obtained Pareto sets testify algorithm effectiveness in searching for solutions to the distributed generation sizing and siting problem, in order to ensure power loss reductions, investment return, and environmental benefits. The proposed methodology contributes to the discussions and perspectives among electricity utilities, DG owners, society, and regulators regarding planning and decision making tools.
- 13 August 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (16) , 7442
Open AccessA Multi-Objective Hybrid Genetic Algorithm for Sizing and Siting of Renewable Distributed Generation
Renewable generation has been addressed in several aspects but it still represents a new paradigm for the expansion of the electricity supply. This paper aims to propose a new model for the sizing and siting problem of distributed generation (DG), based on renewable sources and considering three main aspects: technical, from the distribution utility viewpoint; economical, from the DG owner’s viewpoint, and environmental, from a sustainability perspective. A multi-objective Genetic Algorithm and the Maximin metric are implemented to obtain optimal Pareto sets; also, three decision criteria, considering the concept of preference, are applied to select a final solution from Pareto sets. Case-studies are carried out in medium voltage systems: the 69-bus distribution test system, known from literature, and a 918-bus Brazilian distribution system. Diversity of alternatives in the obtained Pareto sets testify algorithm effectiveness in searching for solutions to the distributed generation sizing and siting problem, in order to ensure power loss reductions, investment return, and environmental benefits. The proposed methodology contributes to the discussions and perspectives among electricity utilities, DG owners, society, and regulators regarding planning and decision making tools.
- Open Access
Interval Load Flow for Uncertainty Consideration in Power Systems Analysis
Modern power systems must deal with a greater degree of uncertainty in power flow calculation due to variations in load and generation introduced by new technologies. This scenario poses new challenges to power system operators which require new tools for an accurate assessment of the system state. This paper presents an interval load flow (ILF) approach for dealing with uncertainty in power system analysis. A probabilistic load flow (PLF), based on Monte Carlo Simulation (MCS), was also implemented for comparative purposes. The ILF and PLF are used to estimate the network states. Both methods were implemented in Python® using the IEEE 34-bus, IEEE 69-bus and 192-bus Brazilian distribution system. The results with the proposed ILF on the aforementioned benchmark test systems proved to be compatible with that of the MCS, evidencing the robustness and applicability of the proposed approach.
Open AccessInterval Load Flow for Uncertainty Consideration in Power Systems Analysis
Modern power systems must deal with a greater degree of uncertainty in power flow calculation due to variations in load and generation introduced by new technologies. This scenario poses new challenges to power system operators which require new tools for an accurate assessment of the system state. This paper presents an interval load flow (ILF) approach for dealing with uncertainty in power system analysis. A probabilistic load flow (PLF), based on Monte Carlo Simulation (MCS), was also implemented for comparative purposes. The ILF and PLF are used to estimate the network states. Both methods were implemented in Python® using the IEEE 34-bus, IEEE 69-bus and 192-bus Brazilian distribution system. The results with the proposed ILF on the aforementioned benchmark test systems proved to be compatible with that of the MCS, evidencing the robustness and applicability of the proposed approach.