Zhongye Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhongye Wu has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Qingfen Ma
College of Mechanical and Electrical Engineering, Hainan University, Haikou 570228, China
9 shared publications - Hui Lu
Institute of Environment and Plant Protection, Chinese Academy of Tropical Agriculture Sciences, Haikou 571101, China
7 shared publications - Jingru Li
School of Mechanical and Electrical Engineering, Hainan University, Haikou 570228, China
6 shared publications - Chengpeng Wang
The Institute of Seawater Desalination & Multipurpose Utilization, MNR, Tianjin 300192, China
2 shared publications - Xin Feng
College of Mechanical and Electrical Engineering, Hainan University, Haikou, Hainan 570228, China
2 shared publications - Xudong Zhao
College of Mechanical and Electrical Engineering, Hainan University, Haikou 570228, China
2 shared publications
Latest Publications
- Open Access
Stress Characteristics Analysis of Aluminum Brazed Structures (ABS) in Liquid Oxygen Subcoolers Under Liquid Nitrogen Conditions
The liquid oxygen subcooler is a key unit for the deep cooling, storage, and transportation of liquid oxygen. Its frequent start–stop operation under liquid nitrogen bath conditions introduces potential risks to service reliability. This study employs a thermo-structural sequential coupling approach to evaluate the stress behavior of ABS components in a flat plate-fin heat exchanger during the pre-cooling, heat-exchange, and recovery stages. Based on the maximum shear stress (Tresca) criterion, the evolution of principal stresses in the brazed layer under liquid nitrogen bath conditions was analyzed, and a conservative assessment of the material’s fatigue behavior was conducted. The results indicate that the equivalent stress is governed by the third principal stress, originating from the thermal compression effect induced by low-temperature constraint shrinkage. During the heat exchange phase (2700 s), the inlet equivalent stress reached 93.49 MPa, which is below the 258 MPa limit, falling within Region 1. Local stress concentration is primarily driven by thermal loading, with brazing layer thickness, curvature radius, and liquid oxygen pressure serving as key control variables. Under a safety factor of 1.15 (107 MPa), fatigue testing exceeding 1.5 million cycles has confirmed the static safety and operational reliability of the ABS.
Open AccessStress Characteristics Analysis of Aluminum Brazed Structures (ABS) in Liquid Oxygen Subcoolers Under Liquid Nitrogen Conditions
The liquid oxygen subcooler is a key unit for the deep cooling, storage, and transportation of liquid oxygen. Its frequent start–stop operation under liquid nitrogen bath conditions introduces potential risks to service reliability. This study employs a thermo-structural sequential coupling approach to evaluate the stress behavior of ABS components in a flat plate-fin heat exchanger during the pre-cooling, heat-exchange, and recovery stages. Based on the maximum shear stress (Tresca) criterion, the evolution of principal stresses in the brazed layer under liquid nitrogen bath conditions was analyzed, and a conservative assessment of the material’s fatigue behavior was conducted. The results indicate that the equivalent stress is governed by the third principal stress, originating from the thermal compression effect induced by low-temperature constraint shrinkage. During the heat exchange phase (2700 s), the inlet equivalent stress reached 93.49 MPa, which is below the 258 MPa limit, falling within Region 1. Local stress concentration is primarily driven by thermal loading, with brazing layer thickness, curvature radius, and liquid oxygen pressure serving as key control variables. Under a safety factor of 1.15 (107 MPa), fatigue testing exceeding 1.5 million cycles has confirmed the static safety and operational reliability of the ABS.
- 1 July 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (4)
Analysis and optimization of a fuel cell-powered multi-purpose vehicle based on three-dimensional thermal management
This study addresses the thermal management and engine compartment optimization of a hydrogen fuel cell multi-purpose vehicle through three-dimensional simulations. A computational fluid dynamics model for the heat dissipation in the engine compartment was developed based on the original design of the vehicle model, and the cooling components (main radiator, secondary radiator, and cooling fan) were validated with experimental data. Under idle and high-speed conditions, the simulated results of heat dissipation in the engine compartment agreed well with the test data, indicating good reliability. Simulation results also revealed significant thermal issues, including severe heat recirculation under idle conditions and reduced air utilization efficiency at high speeds. To mitigate these issues, optimization strategies were proposed through adjusting internal arrangements and modifying external structures. After optimization, temperatures on the main radiator and secondary radiator surfaces were reduced by 7.1% and 2.1%, and airflow through the main radiator and secondary radiator were increased by 22.85% and 16.1% with airflow utilization efficiency enhanced by 38%. Additionally, the driving resistance and the drag coefficient were also reduced by 21% × 10.8%, indicating smoother airflow outside the engine compartment. This approach provides a valuable methodology for thermal management and future optimization of a hydrogen fuel cell vehicle.
- 1 July 2025
- Published by AIP Publishing in Journal of Renewable and Sustainable Energy
- Vol. 17 (4)
Analysis and optimization of a fuel cell-powered multi-purpose vehicle based on three-dimensional thermal management
This study addresses the thermal management and engine compartment optimization of a hydrogen fuel cell multi-purpose vehicle through three-dimensional simulations. A computational fluid dynamics model for the heat dissipation in the engine compartment was developed based on the original design of the vehicle model, and the cooling components (main radiator, secondary radiator, and cooling fan) were validated with experimental data. Under idle and high-speed conditions, the simulated results of heat dissipation in the engine compartment agreed well with the test data, indicating good reliability. Simulation results also revealed significant thermal issues, including severe heat recirculation under idle conditions and reduced air utilization efficiency at high speeds. To mitigate these issues, optimization strategies were proposed through adjusting internal arrangements and modifying external structures. After optimization, temperatures on the main radiator and secondary radiator surfaces were reduced by 7.1% and 2.1%, and airflow through the main radiator and secondary radiator were increased by 22.85% and 16.1% with airflow utilization efficiency enhanced by 38%. Additionally, the driving resistance and the drag coefficient were also reduced by 21% × 10.8%, indicating smoother airflow outside the engine compartment. This approach provides a valuable methodology for thermal management and future optimization of a hydrogen fuel cell vehicle.
- Open Access
- 27 April 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (5) , 873
Optimization Design of Lazy-Wave Dynamic Cable Configuration Based on Machine Learning
The safe and efficient design of dynamic submarine cables is critical for the reliability of floating offshore wind turbines, yet traditional time-domain simulation-based optimization approaches are computationally intensive and time consuming. To address this challenge, this study proposes a closed-loop optimization framework that couples machine learning with intelligent optimization algorithms for a dynamic cable configuration design. A high-fidelity surrogate model based on a backpropagation (BP) neural network was trained to accurately predict cable dynamic responses. Three optimization algorithms—Particle Swarm Optimization (PSO), Ivy Optimization (IVY), and Tornado Optimization (TOC)—were evaluated for their effectiveness in optimizing the arrangement of buoyancy and weight blocks. The TOC algorithm exhibited superior accuracy and convergence stability. Optimization results show an 18.3% reduction in maximum curvature while maintaining allowable effective tension limits. This approach significantly enhances optimization efficiency and provides a viable strategy for the intelligent design of dynamic cable systems. Future work will incorporate platform motions induced by wind turbine operation and explore multi-objective optimization schemes to further improve cable performance.
- 27 April 2025
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 13 (5) , 873
Open AccessOptimization Design of Lazy-Wave Dynamic Cable Configuration Based on Machine Learning
The safe and efficient design of dynamic submarine cables is critical for the reliability of floating offshore wind turbines, yet traditional time-domain simulation-based optimization approaches are computationally intensive and time consuming. To address this challenge, this study proposes a closed-loop optimization framework that couples machine learning with intelligent optimization algorithms for a dynamic cable configuration design. A high-fidelity surrogate model based on a backpropagation (BP) neural network was trained to accurately predict cable dynamic responses. Three optimization algorithms—Particle Swarm Optimization (PSO), Ivy Optimization (IVY), and Tornado Optimization (TOC)—were evaluated for their effectiveness in optimizing the arrangement of buoyancy and weight blocks. The TOC algorithm exhibited superior accuracy and convergence stability. Optimization results show an 18.3% reduction in maximum curvature while maintaining allowable effective tension limits. This approach significantly enhances optimization efficiency and provides a viable strategy for the intelligent design of dynamic cable systems. Future work will incorporate platform motions induced by wind turbine operation and explore multi-objective optimization schemes to further improve cable performance.
- Open Access
- 15 February 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (2) , 334
Simulation Study on Methods for Reducing Dynamic Cable Curvature in Floating Wind Power Platforms
As a key component connecting a floating wind turbine with static sea cables, dynamic cables undergo significant tensile and bending loads caused by hydrostatic pressure, self-weight, waves, and ocean currents during service, which can lead to fatigue failure. Thus, dynamic and fatigue analyses are necessary for the design and operation of dynamic cables. In this study, a fatigue analysis of the three-core four-layer armored dynamic cable used in a semisubmersible floating wind turbine was carried out at a water depth of 25 m. The Miner linear cumulative damage method, based on material S-N curves, was used to predict fatigue life. The results indicate that, at 10 times the safety factor, the dynamic cables meet the design requirement of a 30-year service life in the studied marine environment. The maximal curvature of the dynamic cable always appears at the exit of the bend stiffener, even beyond the allowed point. Adding weights to the section where the cable exits the bend stiffener and adjusting the bend stiffener’s hanging angle can both reduce the curvature at the bend stiffener exit. The scheme of adjusting the bend stiffener’s hanging angle is preferred, for it is easier for simultaneous adjusting and inducing much smaller extra stress in the cable. As the hanging angle increases, the curvature at the bend stiffener exit decreases, while the maximal effective tension and maximal von Mises stress gradually increase. For certain operating conditions, especially with higher waves, it is better to adjust the hanging angle to avoid excessive curvature and, meanwhile, ensure the increase in the stress within a reasonable range.
- 15 February 2024
- Published by MDPI AG in Journal of Marine Science and Engineering
- Vol. 12 (2) , 334
Open AccessSimulation Study on Methods for Reducing Dynamic Cable Curvature in Floating Wind Power Platforms
As a key component connecting a floating wind turbine with static sea cables, dynamic cables undergo significant tensile and bending loads caused by hydrostatic pressure, self-weight, waves, and ocean currents during service, which can lead to fatigue failure. Thus, dynamic and fatigue analyses are necessary for the design and operation of dynamic cables. In this study, a fatigue analysis of the three-core four-layer armored dynamic cable used in a semisubmersible floating wind turbine was carried out at a water depth of 25 m. The Miner linear cumulative damage method, based on material S-N curves, was used to predict fatigue life. The results indicate that, at 10 times the safety factor, the dynamic cables meet the design requirement of a 30-year service life in the studied marine environment. The maximal curvature of the dynamic cable always appears at the exit of the bend stiffener, even beyond the allowed point. Adding weights to the section where the cable exits the bend stiffener and adjusting the bend stiffener’s hanging angle can both reduce the curvature at the bend stiffener exit. The scheme of adjusting the bend stiffener’s hanging angle is preferred, for it is easier for simultaneous adjusting and inducing much smaller extra stress in the cable. As the hanging angle increases, the curvature at the bend stiffener exit decreases, while the maximal effective tension and maximal von Mises stress gradually increase. For certain operating conditions, especially with higher waves, it is better to adjust the hanging angle to avoid excessive curvature and, meanwhile, ensure the increase in the stress within a reasonable range.
- Open Access
- 8 March 2023
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2023, 1-13
Performance Improvement of OTEC-ORC and Turbine Based on Binary Zeotropic Working Fluid
In this paper, the composition of binary nonazeotropic working fluids is explored from the perspective of improving OTEC-ORC efficiency, and the turbine is designed to accommodate with the working fluid. It is found that the OTEC-ORC using a R152a/R32 mixture as the working fluid is significantly higher than the OTEC-ORC thermal efficiency and system efficiency of the pure NH3, and the optimal composition of the mixed working fluid R152a/R32 is determined to be 85:15 with the thermal efficiency and the system efficiency of 2.8 and 1.7, respectively, improving by 35.7 and 151.2 compared to the NH3 ORC. According to the determined working fluid, a one-dimensional (1-D) design and CFD simulation analysis simulation are carried out on the turbine. The 1-D calculation results are in good agreement with the three-dimensional (3-D) results. At the design point, the turbine output is 83.84kW, and the isentropic efficiency is 87.53. At the off-design point, turbines have better off-design performance, indicating that the designed turbine also has good adaptability.
- 8 March 2023
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2023, 1-13
Open AccessPerformance Improvement of OTEC-ORC and Turbine Based on Binary Zeotropic Working Fluid
In this paper, the composition of binary nonazeotropic working fluids is explored from the perspective of improving OTEC-ORC efficiency, and the turbine is designed to accommodate with the working fluid. It is found that the OTEC-ORC using a R152a/R32 mixture as the working fluid is significantly higher than the OTEC-ORC thermal efficiency and system efficiency of the pure NH3, and the optimal composition of the mixed working fluid R152a/R32 is determined to be 85:15 with the thermal efficiency and the system efficiency of 2.8 and 1.7, respectively, improving by 35.7 and 151.2 compared to the NH3 ORC. According to the determined working fluid, a one-dimensional (1-D) design and CFD simulation analysis simulation are carried out on the turbine. The 1-D calculation results are in good agreement with the three-dimensional (3-D) results. At the design point, the turbine output is 83.84kW, and the isentropic efficiency is 87.53. At the off-design point, turbines have better off-design performance, indicating that the designed turbine also has good adaptability.
- Open Access
- 28 December 2022
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2022, 1-13
Analyses of the Design of Multirows Vaneless Staggered Counter-Rotating Turbine
Compared with a conventional turbine, counter rotating turbine has larger thrust weight ratio, shorter axial distance, and higher efficiency. It has been widely used in high-performance aviation. In conventional counter-rotating turbine, HPT is located in the front of LPT, and only a stator row can be eliminated. The layout limits the turbine weight and efficiency. Therefore, the staggered counter rotating turbine is proposed, and the staggered counter rotating turbine can eliminate the all-internal stators, which can greatly improve the turbine weight and efficiency. The staggered counter rotating turbine is the development and improvement of counter rotating turbine. Due to the elimination of the all-internal stators, the downstream rotor will suffer from the insufficient inlet swirl, which is the main question in staggered counter rotating turbine design. Furthermore, the turbine outlet angle is also an important parameter to evaluate the turbine design. The coordination of inlet swirl and outlet Mach number and the outlet angle is discussed by the theoretical method. In order to verify the design method, two-dimensional throughflow design, blade design, and three-dimensional numerical analysis are performed. Expansion ratios and efficiency at the speed combinations of the 80% to 105% are discussed to reveal the turbine characteristics at off-design conditions. An adiabatic total-to-total efficiency of 92.1% with expansion ratio of 4.47 at design point is obtained and achieves the initial design goal very well. The paper is aimed at providing a technical approach to improve the thrust weight ratio, efficiency of high bypass turbofan engines, and provide new ideas for the development of aeroengines.
- 28 December 2022
- Published by Wiley in International Journal of Aerospace Engineering
- Vol. 2022, 1-13
Open AccessAnalyses of the Design of Multirows Vaneless Staggered Counter-Rotating Turbine
Compared with a conventional turbine, counter rotating turbine has larger thrust weight ratio, shorter axial distance, and higher efficiency. It has been widely used in high-performance aviation. In conventional counter-rotating turbine, HPT is located in the front of LPT, and only a stator row can be eliminated. The layout limits the turbine weight and efficiency. Therefore, the staggered counter rotating turbine is proposed, and the staggered counter rotating turbine can eliminate the all-internal stators, which can greatly improve the turbine weight and efficiency. The staggered counter rotating turbine is the development and improvement of counter rotating turbine. Due to the elimination of the all-internal stators, the downstream rotor will suffer from the insufficient inlet swirl, which is the main question in staggered counter rotating turbine design. Furthermore, the turbine outlet angle is also an important parameter to evaluate the turbine design. The coordination of inlet swirl and outlet Mach number and the outlet angle is discussed by the theoretical method. In order to verify the design method, two-dimensional throughflow design, blade design, and three-dimensional numerical analysis are performed. Expansion ratios and efficiency at the speed combinations of the 80% to 105% are discussed to reveal the turbine characteristics at off-design conditions. An adiabatic total-to-total efficiency of 92.1% with expansion ratio of 4.47 at design point is obtained and achieves the initial design goal very well. The paper is aimed at providing a technical approach to improve the thrust weight ratio, efficiency of high bypass turbofan engines, and provide new ideas for the development of aeroengines.
- Open Access
Simulation and Experimental Investigation of the Vacuum-Enhanced Direct Membrane Distillation Driven by a Low-Grade Heat Source
Vacuum-enhanced direct contact membrane distillation (VEDCMD) has been proven experimentally to improve the permeate flux, compared with direct contact membrane distillation (DCMD). However, the theoretical mechanism for its transmembrane transfer process has not been revealed sufficiently. In this paper, with full consideration of the different driving forces of diffusion and Poiseuille flow under the vacuum enhancing condition, a theoretical transmembrane model for mass and heat transfer in VEDCMD is proposed. The CFD model and experimental platform are established to verify the theoretical model. The simulated results agree with the experimental data well, and nearly 200% improvement of the permeate flux is obtained when the permeate pressure drops to 30 kPa. The flow fields of the flow along the membrane surface are obtained and analyzed, with good consistency in the variation of the permeate flux. Since all the parameters of the proposed model are independent of the operating condition, the model is much easier for use and has better adaptability to fluctuating operating conditions.
Open AccessSimulation and Experimental Investigation of the Vacuum-Enhanced Direct Membrane Distillation Driven by a Low-Grade Heat Source
Vacuum-enhanced direct contact membrane distillation (VEDCMD) has been proven experimentally to improve the permeate flux, compared with direct contact membrane distillation (DCMD). However, the theoretical mechanism for its transmembrane transfer process has not been revealed sufficiently. In this paper, with full consideration of the different driving forces of diffusion and Poiseuille flow under the vacuum enhancing condition, a theoretical transmembrane model for mass and heat transfer in VEDCMD is proposed. The CFD model and experimental platform are established to verify the theoretical model. The simulated results agree with the experimental data well, and nearly 200% improvement of the permeate flux is obtained when the permeate pressure drops to 30 kPa. The flow fields of the flow along the membrane surface are obtained and analyzed, with good consistency in the variation of the permeate flux. Since all the parameters of the proposed model are independent of the operating condition, the model is much easier for use and has better adaptability to fluctuating operating conditions.
- Open Access
A Novel Ocean Thermal Energy Driven System for Sustainable Power and Fresh Water Supply
The ocean thermal energy conversion (OTEC) is a potential substitute for traditional power plants in tropical islands and coastal regions. However, the OTEC power generation cycle has low thermal efficiency and the integrated utilization is imperative, in which an OTEC coupled with seawater desalination is the most attractive option. Membrane distillation (MD) has distinct advantages making itself a competitive process for seawater desalination, especially the feature that the drained warm seawater from the OTEC power plant can be recycled, improving the integrated output of the OTEC system. In this study, an innovative OTEC system coupling a power generation sub-cycle (PGC) and a water production sub-cycle (WPC) was proposed, composed of the upstream organic Rankine cycle and the downstream membrane distillation modules. The mass, energy and exergy balance of the individual equipment, the sub-cycles and the whole system were performed by constructing the corresponding balance models. The thermal dynamic parameters were calculated, and the performance of power generation and water production was predicted. The results showed that by coupling with the MD desalination, the thermal efficiency of the OTEC system can be greatly improved from 2.19% to 25.38% while the exergy efficiency changed little. For a 100 kW OTEC power generation cycle, the water production rate approached 58.874 t/d. In addition, the economic analysis based on the electricity and water sale was carried out, and the profit can be improved by extra water production, especially in the Hawaii and Rainbow Beach by nearly 20%.
Open AccessA Novel Ocean Thermal Energy Driven System for Sustainable Power and Fresh Water Supply
The ocean thermal energy conversion (OTEC) is a potential substitute for traditional power plants in tropical islands and coastal regions. However, the OTEC power generation cycle has low thermal efficiency and the integrated utilization is imperative, in which an OTEC coupled with seawater desalination is the most attractive option. Membrane distillation (MD) has distinct advantages making itself a competitive process for seawater desalination, especially the feature that the drained warm seawater from the OTEC power plant can be recycled, improving the integrated output of the OTEC system. In this study, an innovative OTEC system coupling a power generation sub-cycle (PGC) and a water production sub-cycle (WPC) was proposed, composed of the upstream organic Rankine cycle and the downstream membrane distillation modules. The mass, energy and exergy balance of the individual equipment, the sub-cycles and the whole system were performed by constructing the corresponding balance models. The thermal dynamic parameters were calculated, and the performance of power generation and water production was predicted. The results showed that by coupling with the MD desalination, the thermal efficiency of the OTEC system can be greatly improved from 2.19% to 25.38% while the exergy efficiency changed little. For a 100 kW OTEC power generation cycle, the water production rate approached 58.874 t/d. In addition, the economic analysis based on the electricity and water sale was carried out, and the profit can be improved by extra water production, especially in the Hawaii and Rainbow Beach by nearly 20%.
- Open Access
- 1 August 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2006 (1) , 012060
Strategy for Enhancing Fairing Air Conditioning Security Capacity in the On-Time Launch of Chinese Mars-1 Exploration
For the launch of Chinese Mars-1 exploration in a coastal spaceport at noon, summer, there are issues such as big fairing size, complex fairing layout and uncertain flow field of fairing. The author conducted analysis of fairing air conditioning security by thermodynamic modeling calculation and CFD simulation and proposed specific improvement measures to secure on-time launch according to the calculation analysis conclusions. Special test verification was conducted after the carrier rocket transfer. The improvement measures were proven to be effective. During mission launch, the fairing environment security is good. After fairing air conditioning decoupling, the fairing inside temperature rise is within the required scope, ensuring on-time launch of Mars exploration.
- 1 August 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2006 (1) , 012060
Open AccessStrategy for Enhancing Fairing Air Conditioning Security Capacity in the On-Time Launch of Chinese Mars-1 Exploration
For the launch of Chinese Mars-1 exploration in a coastal spaceport at noon, summer, there are issues such as big fairing size, complex fairing layout and uncertain flow field of fairing. The author conducted analysis of fairing air conditioning security by thermodynamic modeling calculation and CFD simulation and proposed specific improvement measures to secure on-time launch according to the calculation analysis conclusions. Special test verification was conducted after the carrier rocket transfer. The improvement measures were proven to be effective. During mission launch, the fairing environment security is good. After fairing air conditioning decoupling, the fairing inside temperature rise is within the required scope, ensuring on-time launch of Mars exploration.
- Open Access
- 27 January 2021
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2021, 1-14
A Hydrostatic Pressure-Driven Desalination System for Large-Scale Deep Sea Space Station
Compared with the common marine renewable energy sources like solar, wind, and wave energy, etc., the hydraulic pressure stored in the deep seawater can output stable and successive energy flow. Thus, it can be directly coupled with the reverse osmosis (RO) process to supply drinkable mineral water for crews of Deep Sea Space Station (DSSS). We proposed a novel submarine RO desalination system driven by the hydraulic pressure of deep seawater (SHP-RO), composed of a desalination branch to generate fresh water and a back pressure branch to ensure the depth independence of the desalination. The influences of the deep sea environment on the RO were analyzed, based on which the pretreatment of the seawater and the preparation of the drinkable mineral water were studied. The turbine-based energy recovery scheme was investigated in virtue of the CFD simulation on the flow behavior in the different turbine series. It was predicted that, when the DSSS was located at the depth of 1100m and the operating pressure of the RO process was 6.0MPa, for a drinkable water production rate of 240m3/d, the recovered hydraulic pressure energy can achieve 39.22kW·h, which was enough for driving electricity consumers in the SHP-RO system.
- 27 January 2021
- Published by Wiley in International Journal of Chemical Engineering
- Vol. 2021, 1-14
Open AccessA Hydrostatic Pressure-Driven Desalination System for Large-Scale Deep Sea Space Station
Compared with the common marine renewable energy sources like solar, wind, and wave energy, etc., the hydraulic pressure stored in the deep seawater can output stable and successive energy flow. Thus, it can be directly coupled with the reverse osmosis (RO) process to supply drinkable mineral water for crews of Deep Sea Space Station (DSSS). We proposed a novel submarine RO desalination system driven by the hydraulic pressure of deep seawater (SHP-RO), composed of a desalination branch to generate fresh water and a back pressure branch to ensure the depth independence of the desalination. The influences of the deep sea environment on the RO were analyzed, based on which the pretreatment of the seawater and the preparation of the drinkable mineral water were studied. The turbine-based energy recovery scheme was investigated in virtue of the CFD simulation on the flow behavior in the different turbine series. It was predicted that, when the DSSS was located at the depth of 1100m and the operating pressure of the RO process was 6.0MPa, for a drinkable water production rate of 240m3/d, the recovered hydraulic pressure energy can achieve 39.22kW·h, which was enough for driving electricity consumers in the SHP-RO system.