Mingjie Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mingjie Li has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Wenxin Luo
Guangdong University of Technology
12 shared publications- Wenxin Luo
School of Integrated Circuits, Guangdong University of Technology, Guangzhou, China
8 shared publications - Wenjun Yan
Hangzhou Dianzi University
5 shared publications - Fei Wang
School of Microelectronics Southern University of Science and Technology Shenzhen China
4 shared publications - Jianhao Li
School of Integrated Circuits, Guangdong University of Technology, Guangzhou, China
4 shared publications - Ming Zhang
Hunan University
4 shared publications
Latest Publications
- 2 November 2026
- Published by IOP Publishing in Smart Materials and Structures
Dual-temperature MEMS sensors for progressive thermal-runaway-related gas prediction via a CNN–transformer network
Early detection of lithium-ion battery (LIB) thermal runaway is essential to prevent disastrous failures. While gas sensor arrays detect characteristic off-gases (H 2 , CO, CH 4 ), a large amount of sensing elements may increase heating power and hardware complexity. We propose a dual-temperature sensing system comprising only two MoS 2 @ZIF-67 microelectromechanical systems (MEMS) gas sensors with a dual-history convolutional neural network (CNN)-Transformer for progressive gas-concentration estimation. The sensors operate simultaneously at constant heater voltages of 2.5 and 3.0 V, providing two resistance channels. Independent CNN–Transformer encoders process short and longer signal histories to estimate H 2 , CO and CH 4 concentrations, followed by causal smoothing using an exponentially weighted moving average (EWMA). Exploratory evaluation on separately acquired 100 and 200 ppm records yielded a total-concentration mean absolute error (MAE) of 31.25 ppm after EWMA smoothing across gas-exposure and clean-air windows. These results establish a proof of concept for progressive three-component concentration estimation in prescribed thermal-runaway-related mixtures using a compact two-sensor configuration with a combined nominal heater power of approximately 48 mW.
- 2 November 2026
- Published by IOP Publishing in Smart Materials and Structures
Dual-temperature MEMS sensors for progressive thermal-runaway-related gas prediction via a CNN–transformer network
Early detection of lithium-ion battery (LIB) thermal runaway is essential to prevent disastrous failures. While gas sensor arrays detect characteristic off-gases (H 2 , CO, CH 4 ), a large amount of sensing elements may increase heating power and hardware complexity. We propose a dual-temperature sensing system comprising only two MoS 2 @ZIF-67 microelectromechanical systems (MEMS) gas sensors with a dual-history convolutional neural network (CNN)-Transformer for progressive gas-concentration estimation. The sensors operate simultaneously at constant heater voltages of 2.5 and 3.0 V, providing two resistance channels. Independent CNN–Transformer encoders process short and longer signal histories to estimate H 2 , CO and CH 4 concentrations, followed by causal smoothing using an exponentially weighted moving average (EWMA). Exploratory evaluation on separately acquired 100 and 200 ppm records yielded a total-concentration mean absolute error (MAE) of 31.25 ppm after EWMA smoothing across gas-exposure and clean-air windows. These results establish a proof of concept for progressive three-component concentration estimation in prescribed thermal-runaway-related mixtures using a compact two-sensor configuration with a combined nominal heater power of approximately 48 mW.
- 1 November 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (11) , 115006
H 2 and CO identification and concentration prediction using a pulse-driven MEMS gas sensor with multi-feature, multi-task learning
Metal-oxide-semiconductor (MOS) gas sensors are attractive for compact monitoring but remain constrained by cross-reactivity and reliance on steady-state measurements. Here, a suspended Cu–SnO 2 microelectromechanical systems chemiresistor was integrated with a multi-feature, multi-task temporal network for hydrogen (H 2 )/carbon monoxide (CO) identification and quantification. The heater cycled between approximately 90 °C for 0.8 s and 350 °C for 1.6 s at an average power of 19.8 mW. Currents recorded at 10 Hz during 200–900 ppm exposures were transformed into 4.8 s moving-average, Hilbert-envelope, and temporal-derivative channels. Sliding time windows were analyzed using a multi-scale convolutional neural network-squeeze-and-excitation-bidirectional long short-term memory architecture with attention-based classification and gas-specific regression heads. For separately acquired test sequences at 200 and 250 ppm, the three-model ensemble achieved classification accuracy of 99.95% and a gas-only mean absolute error of 25.79 ppm using a 12 s window with a 0.1 s stride in offline replay. These results demonstrate a compact, low-power approach to multi-task gas identification and concentration prediction using a single microsensor.
- 1 November 2026
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 36 (11) , 115006
H 2 and CO identification and concentration prediction using a pulse-driven MEMS gas sensor with multi-feature, multi-task learning
Metal-oxide-semiconductor (MOS) gas sensors are attractive for compact monitoring but remain constrained by cross-reactivity and reliance on steady-state measurements. Here, a suspended Cu–SnO 2 microelectromechanical systems chemiresistor was integrated with a multi-feature, multi-task temporal network for hydrogen (H 2 )/carbon monoxide (CO) identification and quantification. The heater cycled between approximately 90 °C for 0.8 s and 350 °C for 1.6 s at an average power of 19.8 mW. Currents recorded at 10 Hz during 200–900 ppm exposures were transformed into 4.8 s moving-average, Hilbert-envelope, and temporal-derivative channels. Sliding time windows were analyzed using a multi-scale convolutional neural network-squeeze-and-excitation-bidirectional long short-term memory architecture with attention-based classification and gas-specific regression heads. For separately acquired test sequences at 200 and 250 ppm, the three-model ensemble achieved classification accuracy of 99.95% and a gas-only mean absolute error of 25.79 ppm using a 12 s window with a 0.1 s stride in offline replay. These results demonstrate a compact, low-power approach to multi-task gas identification and concentration prediction using a single microsensor.
- 25 September 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (10) , 9133-9143
Overcoming Cross-Sensitivity for the Accurate Identification of Acetone, Isopropanol, and Clinical Mixtures Using a MEMS Dual-Sensor Array and Multi-task Deep Learning
Accurate detection of exhaled acetone (ACE) and isopropanol (IPA) mixtures is critical for the non-invasive screening of diabetic ketoacidosis and the continuous monitoring of lipid metabolism in type 1 diabetes mellitus. However, the broad clinical application of this approach remains severely constrained by the inherent cross-sensitivity of metal oxide semiconductor (MOS) sensors. To address this, a microelectromechanical systems (MEMS) dual-sensor array integrating PdO-modified SnO2/ZnO and MoS2/ZIF-67 nanocomposites was developed for simultaneous gas identification and concentration regression. By pioneering the extraction of distinct transient thermokinetic responses of the materials, combined with a multi-task learning architecture featuring a 1D Convolutional Neural Network and a Bidirectional Long Short-Term Memory (CNN-BiLSTM) network, the system efficiently analyzed dynamic sensing data using a sliding time window (K). At an optimal 15-s window, the model demonstrated robust real-time predictive capabilities, achieving 95.4% classification accuracy and a regression mean absolute error (MAE) of 0.625 ppm across clinical IPA/ACE ratios. This deep learning-enabled framework circumvents traditional steady-state limitations, providing a scalable, low-power solution for precise clinical breathomics and metabolic disease screening.
- 25 September 2026
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 11 (10) , 9133-9143
Overcoming Cross-Sensitivity for the Accurate Identification of Acetone, Isopropanol, and Clinical Mixtures Using a MEMS Dual-Sensor Array and Multi-task Deep Learning
Accurate detection of exhaled acetone (ACE) and isopropanol (IPA) mixtures is critical for the non-invasive screening of diabetic ketoacidosis and the continuous monitoring of lipid metabolism in type 1 diabetes mellitus. However, the broad clinical application of this approach remains severely constrained by the inherent cross-sensitivity of metal oxide semiconductor (MOS) sensors. To address this, a microelectromechanical systems (MEMS) dual-sensor array integrating PdO-modified SnO2/ZnO and MoS2/ZIF-67 nanocomposites was developed for simultaneous gas identification and concentration regression. By pioneering the extraction of distinct transient thermokinetic responses of the materials, combined with a multi-task learning architecture featuring a 1D Convolutional Neural Network and a Bidirectional Long Short-Term Memory (CNN-BiLSTM) network, the system efficiently analyzed dynamic sensing data using a sliding time window (K). At an optimal 15-s window, the model demonstrated robust real-time predictive capabilities, achieving 95.4% classification accuracy and a regression mean absolute error (MAE) of 0.625 ppm across clinical IPA/ACE ratios. This deep learning-enabled framework circumvents traditional steady-state limitations, providing a scalable, low-power solution for precise clinical breathomics and metabolic disease screening.
- Open Access
- 10 September 2026
- Published by Elsevier in Cell Reports Physical Science
- Vol. 7 (10)
Real-time thermokinetic combinatorial fingerprinting of toxic gases with a MEMS e-nose
- 10 September 2026
- Published by Elsevier in Cell Reports Physical Science
- Vol. 7 (10)
Open AccessReal-time thermokinetic combinatorial fingerprinting of toxic gases with a MEMS e-nose
- Open Access
- 3 September 2026
- Published by AIP Publishing in Nanotechnology and Precision Engineering
- Vol. 10 (1)
Optimizing dynamic pulsing characteristics for highly sensitive and energy-efficient MEMS hydrogen sensors
This study characterizes the effects of dynamic pulsing parameters on hydrogen (H2) gas detection using a novel microheater-integrated metal oxide semiconductor (MOS) sensor. The proposed single-device system operates through duty cycling by utilizing repeated pulsed power inputs. The impact of pulse characteristics, specifically the pulse period and duty cycle, on the overall sensor performance is systematically evaluated. The results demonstrate that operating at an optimal pulse period of 2.4 s with a 67% duty cycle provides a 32% enhancement in the hydrogen response without compromising the response time. In addition, this designed duty-cycling strategy significantly reduces energy consumption, achieving a low average power consumption of ∼19.8 mW. Fabricated using wafer-level batch processing techniques, this compact and energy-efficient sensor platform represents a highly scalable and commercially viable solution for integration into power-constrained Internet of Things monitoring applications.
- 3 September 2026
- Published by AIP Publishing in Nanotechnology and Precision Engineering
- Vol. 10 (1)
Open AccessOptimizing dynamic pulsing characteristics for highly sensitive and energy-efficient MEMS hydrogen sensors
This study characterizes the effects of dynamic pulsing parameters on hydrogen (H2) gas detection using a novel microheater-integrated metal oxide semiconductor (MOS) sensor. The proposed single-device system operates through duty cycling by utilizing repeated pulsed power inputs. The impact of pulse characteristics, specifically the pulse period and duty cycle, on the overall sensor performance is systematically evaluated. The results demonstrate that operating at an optimal pulse period of 2.4 s with a 67% duty cycle provides a 32% enhancement in the hydrogen response without compromising the response time. In addition, this designed duty-cycling strategy significantly reduces energy consumption, achieving a low average power consumption of ∼19.8 mW. Fabricated using wafer-level batch processing techniques, this compact and energy-efficient sensor platform represents a highly scalable and commercially viable solution for integration into power-constrained Internet of Things monitoring applications.
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (4) , 2185-2191
Dual-Transduction MEMS Gas Sensor for H 2 and CO Identification Across Humidity
Selective discrimination between explosive H2 and CO gases while preserving moisture resistance is of paramount importance. Conventional metal–oxide–semiconductor (MOS) gas sensors suffer from poor selectivity, and reliable multigas identification with a single device remains challenging. Here, we report a microelectromechanical systems (MEMS) gas sensor that integrates two transduction mechanisms, enabling single-sensor gas identification. We demonstrate this innovative approach through the simultaneous measurement of chemiresistive response and temperature change of the sensing layer. Due to gas-specific catalytic exothermic reaction and distinct redox rates on the MOS surface, and maintaining stability under humidity, the relatively independent resistive and calorimetric signals allow robust classifications of H2 and CO gases across humidity conditions using linear discriminant analysis (LDA). We hope our work could resolve the key bottleneck in multigas identification via a single device and offer guidance for intelligent gas sensor technology with compact MEMS platforms.
- 19 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (4) , 2185-2191
Dual-Transduction MEMS Gas Sensor for H 2 and CO Identification Across Humidity
Selective discrimination between explosive H2 and CO gases while preserving moisture resistance is of paramount importance. Conventional metal–oxide–semiconductor (MOS) gas sensors suffer from poor selectivity, and reliable multigas identification with a single device remains challenging. Here, we report a microelectromechanical systems (MEMS) gas sensor that integrates two transduction mechanisms, enabling single-sensor gas identification. We demonstrate this innovative approach through the simultaneous measurement of chemiresistive response and temperature change of the sensing layer. Due to gas-specific catalytic exothermic reaction and distinct redox rates on the MOS surface, and maintaining stability under humidity, the relatively independent resistive and calorimetric signals allow robust classifications of H2 and CO gases across humidity conditions using linear discriminant analysis (LDA). We hope our work could resolve the key bottleneck in multigas identification via a single device and offer guidance for intelligent gas sensor technology with compact MEMS platforms.
- Top Cited Papers
- 1 February 2026
- Published by IOP Publishing in Journal of Semiconductors
- Vol. 47 (2) , 022303
Identification of H 2 and NH 3 gases using calorimetric signals and transient response through machine learning
Selectivity remains a significant challenge for gas sensors. In contrast to conventional gas sensors that depend solely on conductivity to detect gases, we exploited a single NiO-doped SnO 2 sensor to simultaneously monitor transient changes in both sensor conductivity and temperature. The distinct response profiles of H 2 and NH 3 gases were attributed to differences in their redox rates and enthalpy changes during chemical reactions, which provided an opportunity for gas identification using machine learning (ML) algorithms. The test results indicate that preprocessing the extracted calorimetric and chemi-resistive parameters using the principal component analysis (PCA), followed by the application of ML classifiers for identification, enables a 100% accuracy for both target analytes. This work presents a facile gas identification method that enhances chip-level sensor applications while minimizing the need for complex sensor arrays.
- 1 February 2026
- Published by IOP Publishing in Journal of Semiconductors
- Vol. 47 (2) , 022303
Top Cited PapersIdentification of H 2 and NH 3 gases using calorimetric signals and transient response through machine learning
Selectivity remains a significant challenge for gas sensors. In contrast to conventional gas sensors that depend solely on conductivity to detect gases, we exploited a single NiO-doped SnO 2 sensor to simultaneously monitor transient changes in both sensor conductivity and temperature. The distinct response profiles of H 2 and NH 3 gases were attributed to differences in their redox rates and enthalpy changes during chemical reactions, which provided an opportunity for gas identification using machine learning (ML) algorithms. The test results indicate that preprocessing the extracted calorimetric and chemi-resistive parameters using the principal component analysis (PCA), followed by the application of ML classifiers for identification, enables a 100% accuracy for both target analytes. This work presents a facile gas identification method that enhances chip-level sensor applications while minimizing the need for complex sensor arrays.
- Top Cited PapersOpen Access
- 23 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-12
Pulse-driven MEMS gas sensor combined with machine learning for selective gas identification
The sensing and identification of trace gases are essential for ensuring chemical safety and protecting human health. This study introduces a low-power electronic nose system that utilizes a single sensor driven by repeated pulsed power inputs, offering a viable alternative to conventional sensor array-based methods. The sensor’s compact design and suspended architecture facilitate a rapid thermal response, effectively decoupling the influences of temperature, physisorption, and charge exchange on the conductivity of the sensing material. This mechanism generates distinct gas sensing responses, characterized by alternating dual responses within a single time period. The unique dynamics of the dual signals, which vary with gas type and concentration, enable precise identification of multiple gas species using machine learning (ML) algorithms. Microfabricated through wafer-level batch processing, our innovative electronic nose system holds significant potential for battery-powered mobile devices and IoT-based monitoring applications.
- 23 April 2025
- Published by Springer Nature in Microsystems & Nanoengineering
- Vol. 11 (1) , 1-12
Top Cited PapersOpen AccessPulse-driven MEMS gas sensor combined with machine learning for selective gas identification
The sensing and identification of trace gases are essential for ensuring chemical safety and protecting human health. This study introduces a low-power electronic nose system that utilizes a single sensor driven by repeated pulsed power inputs, offering a viable alternative to conventional sensor array-based methods. The sensor’s compact design and suspended architecture facilitate a rapid thermal response, effectively decoupling the influences of temperature, physisorption, and charge exchange on the conductivity of the sensing material. This mechanism generates distinct gas sensing responses, characterized by alternating dual responses within a single time period. The unique dynamics of the dual signals, which vary with gas type and concentration, enable precise identification of multiple gas species using machine learning (ML) algorithms. Microfabricated through wafer-level batch processing, our innovative electronic nose system holds significant potential for battery-powered mobile devices and IoT-based monitoring applications.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (11) , 7016-7021
A Single MEMS Sensor Based on SnO₂ Nanosheets for Selective Gas Identification
In recent years, the challenge of poor selectivity in a single gas sensor has received significant interest. This work presents a facile method for the concurrent analysis of sensor temperature variations and conductivity changes in a SnO2 nanosheets-based gas sensor, enabling the selective detection of various gases (such as H2, NH3, and CO). When exposed to reducing gases, the sensor typically exhibits increases in temperature (calorimetric readout) and current (chemo-resistive readout), resulting from the exothermic reaction between the gases and surface oxygen species. The integrated assessment of temperature elevation and conductivity alterations in a single sensor offers an innovative strategy for gas identification and concentration measurement.
- 1 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 71 (11) , 7016-7021
A Single MEMS Sensor Based on SnO₂ Nanosheets for Selective Gas Identification
In recent years, the challenge of poor selectivity in a single gas sensor has received significant interest. This work presents a facile method for the concurrent analysis of sensor temperature variations and conductivity changes in a SnO2 nanosheets-based gas sensor, enabling the selective detection of various gases (such as H2, NH3, and CO). When exposed to reducing gases, the sensor typically exhibits increases in temperature (calorimetric readout) and current (chemo-resistive readout), resulting from the exothermic reaction between the gases and surface oxygen species. The integrated assessment of temperature elevation and conductivity alterations in a single sensor offers an innovative strategy for gas identification and concentration measurement.
- 26 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 85, 481-488
NiO nanoparticles-based gas sensors: A novel pulse-driven approach for enhanced and efficient hydrogen detection
- 26 August 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 85, 481-488
NiO nanoparticles-based gas sensors: A novel pulse-driven approach for enhanced and efficient hydrogen detection