Jennie Crosby
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jennie Crosby has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Annie Xiao
The University of Chicago Pritzker School of Medicine, Chicago, IL, USA
1 shared publicationClara Duan
The Univ. of Chicago (United States)
1 shared publicationClaudia I. Henschke
Icahn School of Medicine at Mount Sinai (United States)
1 shared publicationDavid F. Yankelevitz
Icahn School of Medicine at Mount Sinai (United States)
1 shared publicationFeng Li
The Univ. of Chicago (United States)
1 shared publication- Feng Li
Univ Chicago, Dept Radiol, MC-2026,5841 S Maryland Ave, Chicago, IL 60637 USA
1 shared publication
Latest Publications
- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 016501-12
Deep convolutional neural networks in the classification of dual-energy thoracic radiographic views for efficient workflow: analysis on over 6500 clinical radiographs
DICOM header information is frequently used to classify medical image types; however, if a header is missing fields or contains incorrect data, the utility is limited. To expedite image classification, we trained convolutional neural networks (CNNs) in two classification tasks for thoracic radiographic views obtained from dual-energy studies: (a) distinguishing between frontal, lateral, soft tissue, and bone images and (b) distinguishing between posteroanterior (PA) or anteroposterior (AP) chest radiographs. CNNs with AlexNet architecture were trained from scratch. 1910 manually classified radiographs were used for training the network to accomplish task (a), then tested with an independent test set (3757 images). Frontal radiographs from the two datasets were combined to train a network to accomplish task (b); tested using an independent test set of 1000 radiographs. ROC analysis was performed for each trained CNN with area under the curve (AUC) as a performance metric. Classification between frontal images (AP/PA) and other image types yielded an AUC of 0.997 [95% confidence interval (CI): 0.996, 0.998]. Classification between PA and AP radiographs resulted in an AUC of 0.973 (95% CI: 0.961, 0.981). CNNs were able to rapidly classify thoracic radiographs with high accuracy, thus potentially contributing to effective and efficient workflow.
- 1 January 2020
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 7 (01) , 016501-12
Deep convolutional neural networks in the classification of dual-energy thoracic radiographic views for efficient workflow: analysis on over 6500 clinical radiographs
DICOM header information is frequently used to classify medical image types; however, if a header is missing fields or contains incorrect data, the utility is limited. To expedite image classification, we trained convolutional neural networks (CNNs) in two classification tasks for thoracic radiographic views obtained from dual-energy studies: (a) distinguishing between frontal, lateral, soft tissue, and bone images and (b) distinguishing between posteroanterior (PA) or anteroposterior (AP) chest radiographs. CNNs with AlexNet architecture were trained from scratch. 1910 manually classified radiographs were used for training the network to accomplish task (a), then tested with an independent test set (3757 images). Frontal radiographs from the two datasets were combined to train a network to accomplish task (b); tested using an independent test set of 1000 radiographs. ROC analysis was performed for each trained CNN with area under the curve (AUC) as a performance metric. Classification between frontal images (AP/PA) and other image types yielded an AUC of 0.997 [95% confidence interval (CI): 0.996, 0.998]. Classification between PA and AP radiographs resulted in an AUC of 0.973 (95% CI: 0.961, 0.981). CNNs were able to rapidly classify thoracic radiographs with high accuracy, thus potentially contributing to effective and efficient workflow.
- 15 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10954, 109540E
Impact of imprinted labels on deep learning classification of AP and PA thoracic radiographs
Deep learning can be used to classify images to verify or correct DICOM header information. One situation where this is useful is in the classification of thoracic radiographs that were acquired anteroposteriorly (AP) or posteroanteriorly (PA). A convolutional neural network (CNN) was previously trained and showed a strong performance in the task of classifying between AP and PA radiographs, giving a 0.97 ± 0.005 AUC for an independent test set. However, 81% of the AP training set and 24% of the AP independent test set consisted of images with imprinted labels. To evaluate the effect of labels on training and testing of a CNN, the labels on the images used for training were removed by cropping. Then the CNN was retrained using the cropped images with the same training parameters as before. The retrained CNN was tested on the same independent test set and resulted in a 0.95 ± 0.007 AUC in the task of classifying between AP and PA radiographs. The p-value is 0.002 between the AUCs from the two networks, showing a statistically significant decrease in performance by the network trained on the cropped images. The decrease in performance may be due to the network being previously trained to recognize imprinted labels or due to relevant anatomy being cropped along with the label, however, the performance is still high and can be incorporated in clinical workflow.
- 15 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10954, 109540E
Impact of imprinted labels on deep learning classification of AP and PA thoracic radiographs
Deep learning can be used to classify images to verify or correct DICOM header information. One situation where this is useful is in the classification of thoracic radiographs that were acquired anteroposteriorly (AP) or posteroanteriorly (PA). A convolutional neural network (CNN) was previously trained and showed a strong performance in the task of classifying between AP and PA radiographs, giving a 0.97 ± 0.005 AUC for an independent test set. However, 81% of the AP training set and 24% of the AP independent test set consisted of images with imprinted labels. To evaluate the effect of labels on training and testing of a CNN, the labels on the images used for training were removed by cropping. Then the CNN was retrained using the cropped images with the same training parameters as before. The retrained CNN was tested on the same independent test set and resulted in a 0.95 ± 0.007 AUC in the task of classifying between AP and PA radiographs. The p-value is 0.002 between the AUCs from the two networks, showing a statistically significant decrease in performance by the network trained on the cropped images. The decrease in performance may be due to the network being previously trained to recognize imprinted labels or due to relevant anatomy being cropped along with the label, however, the performance is still high and can be incorporated in clinical workflow.
- 13 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10950, 1095039
Detection and classification of coronary artery calcifications in low dose thoracic CT using deep learning
Deep Learning is expanding in the detection and diagnosis of abnormalities , including coronary artery calcification (CAC), in CT. CACs can also be visualized on low-dose thoracic screening CTs (LDCT), and thus, in this study, deep learning is investigated for the detection of CACs and assessment of their severity on LDCT images. The study dataset included 863 LDCT cases, each assigned a case severity score, which is related to the Agatston score, ranging between 0 and 12 (0 = no CAC present, 12 = severe CACs). Within the cardiac region, 224 × 224 pixel ROIs were extracted from each CT slice and input to a convolutional neural network (CNN). CNN-based features were extracted using a pre-trained VGG19 and merged with a support vector machine (SVM) yielding a slice likelihood score of the presence of CACs . Case prediction scores were obtained by using the maximum and mean scores of all slices belonging to that case. Area under the ROC curve (AUC) was used as a metric to assess the discrimination performance level. Using a randomly selected subset of images containing similar amounts of each severity subtype, the SVM performed better using the max slice score per case (AUC = 0.79, standard error = 0.03). While this AUC value does not reach those found in similar studies for diagnostic CT and cardiac CT angiography, this study demonstrates potential for deep learning use in LDCT screening programs.
- 13 March 2019
- Published by SPIE-Intl Soc Optical Eng
- Vol. 10950, 1095039
Detection and classification of coronary artery calcifications in low dose thoracic CT using deep learning
Deep Learning is expanding in the detection and diagnosis of abnormalities , including coronary artery calcification (CAC), in CT. CACs can also be visualized on low-dose thoracic screening CTs (LDCT), and thus, in this study, deep learning is investigated for the detection of CACs and assessment of their severity on LDCT images. The study dataset included 863 LDCT cases, each assigned a case severity score, which is related to the Agatston score, ranging between 0 and 12 (0 = no CAC present, 12 = severe CACs). Within the cardiac region, 224 × 224 pixel ROIs were extracted from each CT slice and input to a convolutional neural network (CNN). CNN-based features were extracted using a pre-trained VGG19 and merged with a support vector machine (SVM) yielding a slice likelihood score of the presence of CACs . Case prediction scores were obtained by using the maximum and mean scores of all slices belonging to that case. Area under the ROC curve (AUC) was used as a metric to assess the discrimination performance level. Using a randomly selected subset of images containing similar amounts of each severity subtype, the SVM performed better using the max slice score per case (AUC = 0.79, standard error = 0.03). While this AUC value does not reach those found in similar studies for diagnostic CT and cardiac CT angiography, this study demonstrates potential for deep learning use in LDCT screening programs.
- Open Access
- 22 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (4) , 205-213
Single‐institution report of setup margins of voluntary deep‐inspiration breath‐hold (DIBH) whole breast radiotherapy implemented with real‐time surface imaging
Purpose: We calculated setup margins for whole breast radiotherapy during voluntary deep‐inspiration breath‐hold (vDIBH) using real‐time surface imaging (SI).Methods and Materials: Patients (n = 58) with a 27‐to‐31 split between right‐ and left‐sided cancers were analyzed. Treatment beams were gated using AlignRT by registering the whole breast region‐of‐interest to the surface generated from the simulation CT scan. AlignRT recorded (three‐dimensional) 3D displacements and the beam‐on‐state every 0.3 s. Means and standard deviations of the displacements during vDIBH for each fraction were used to calculate setup margins. Intra‐DIBH stability and the intrafraction reproducibility were estimated from the medians of the 5th to 95th percentile range of the translations in each breath‐hold and fraction, respectively.Results: A total of 7269 breath‐holds were detected over 1305 fractions in which a median dose of 200 cGy was delivered. Each fraction was monitored for 5.95 ± 2.44 min. Calculated setup margins were 4.8 mm (A/P), 4.9 mm (S/I), and 6.4 mm (L/R). The intra‐DIBH stability and the intrafraction reproducibility were ≤0.7 mm and ≤2.2 mm, respectively. The isotropic margin according to SI (9.2 mm) was comparable to other institutions’ calculations that relied on x‐ray imaging and/or spirometry for patients with left‐sided cancer (9.8–11.0 mm). Likewise, intra‐DIBH variability and intrafraction reproducibility of breast surface measured with SI agreed with spirometry‐based positioning to within 1.2 and 0.36 mm, respectively.Conclusions: We demonstrated that intra‐DIBH variability, intrafraction reproducibility, and setup margins are similar to those reported by peer studies who utilized spirometry‐based positioning.
- 22 June 2018
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 19 (4) , 205-213
Open AccessSingle‐institution report of setup margins of voluntary deep‐inspiration breath‐hold (DIBH) whole breast radiotherapy implemented with real‐time surface imaging
Purpose: We calculated setup margins for whole breast radiotherapy during voluntary deep‐inspiration breath‐hold (vDIBH) using real‐time surface imaging (SI).Methods and Materials: Patients (n = 58) with a 27‐to‐31 split between right‐ and left‐sided cancers were analyzed. Treatment beams were gated using AlignRT by registering the whole breast region‐of‐interest to the surface generated from the simulation CT scan. AlignRT recorded (three‐dimensional) 3D displacements and the beam‐on‐state every 0.3 s. Means and standard deviations of the displacements during vDIBH for each fraction were used to calculate setup margins. Intra‐DIBH stability and the intrafraction reproducibility were estimated from the medians of the 5th to 95th percentile range of the translations in each breath‐hold and fraction, respectively.Results: A total of 7269 breath‐holds were detected over 1305 fractions in which a median dose of 200 cGy was delivered. Each fraction was monitored for 5.95 ± 2.44 min. Calculated setup margins were 4.8 mm (A/P), 4.9 mm (S/I), and 6.4 mm (L/R). The intra‐DIBH stability and the intrafraction reproducibility were ≤0.7 mm and ≤2.2 mm, respectively. The isotropic margin according to SI (9.2 mm) was comparable to other institutions’ calculations that relied on x‐ray imaging and/or spirometry for patients with left‐sided cancer (9.8–11.0 mm). Likewise, intra‐DIBH variability and intrafraction reproducibility of breast surface measured with SI agreed with spirometry‐based positioning to within 1.2 and 0.36 mm, respectively.Conclusions: We demonstrated that intra‐DIBH variability, intrafraction reproducibility, and setup margins are similar to those reported by peer studies who utilized spirometry‐based positioning.