Jiacheng Wang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jiacheng Wang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Binlin Dou
School of Energy and Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
1 shared publication - Boren Zheng
Department of Energy Engineering, Zhejiang University, 38 Zheda Road, Hangzhou 310027, China
1 shared publication - David John Kukulka
Department of Mechanical Engineering, State University of New York College at Buffalo, 1300 Elmwood Avenue, Buffalo, NY 14222, USA
1 shared publication - David John Kukulka
Department of Mechanical Engineering Technology, State University of New York College at Buffalo, 1300 Elmwood Avenue, Buffalo, NY 14222, USA
1 shared publication - Rick Smith
Vipertex Division, Rigidized Metals Corporation, 658 Ohio Street, Buffalo, NY 14203, USA
1 shared publication - Sherif A. Sherif
Department of Mechanical and Aerospace Engineering, University of Florida , 1064 Center Drive, 181 NEB Building, Gainesville, FL 32611
1 shared publication
Latest Publications
- 7 March 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (4) , 1-13
Flow Boiling Heat Transfer in Enhanced Tubes With Composite Structure
To fill the research gaps in the study of flow boiling on composite surfaces, four heat exchange tubes with different structures were investigated: an enhanced tube with herringbone teeth (EHT_HB), a tube with a dimple structure (EHT_DIM), a tube with a composite herringbone tooth/dimple structure (EHT_HB/DIM), and a smooth tube as a baseline for comparison purposes. The experimental conditions were set as follows: saturation temperature 6°C, mass flux 50-205 kg/(m2.s), and vapor quality 0.2-0.8. After confirming the validity of the experimental results, the effects of the mass flux on the flow boiling heat transfer and pressure drop characteristics were examined. Results showed that the flow boiling heat transfer coefficient and pressure drop increase with the increase of the mass flux and the vapor quality in the tested tubes. The EHT_HB/DIM tube was found to combine the advantages of the two structures and to have the highest heat transfer coefficient. The average value of the heat transfer coefficient was found to be 43.75% higher than that of the smooth tube. Also, the average flow boiling heat transfer coefficients of the EHT_HB and the EHT_DIM tubes were found to be 15% and 35% higher that of the smooth tube, respectively. From the perspective of the frictional pressure drop, it was found that the EHT_HB/DIM tube exhibited the maximum frictional pressure drop. The optimum working conditions of the enhanced tubes were determined by introducing a performance factor that captures the combined effects of heat transfer and pressure drop.
- 7 March 2024
- Published by ASME International in Journal of Solar Energy Engineering
- Vol. 146 (4) , 1-13
Flow Boiling Heat Transfer in Enhanced Tubes With Composite Structure
To fill the research gaps in the study of flow boiling on composite surfaces, four heat exchange tubes with different structures were investigated: an enhanced tube with herringbone teeth (EHT_HB), a tube with a dimple structure (EHT_DIM), a tube with a composite herringbone tooth/dimple structure (EHT_HB/DIM), and a smooth tube as a baseline for comparison purposes. The experimental conditions were set as follows: saturation temperature 6°C, mass flux 50-205 kg/(m2.s), and vapor quality 0.2-0.8. After confirming the validity of the experimental results, the effects of the mass flux on the flow boiling heat transfer and pressure drop characteristics were examined. Results showed that the flow boiling heat transfer coefficient and pressure drop increase with the increase of the mass flux and the vapor quality in the tested tubes. The EHT_HB/DIM tube was found to combine the advantages of the two structures and to have the highest heat transfer coefficient. The average value of the heat transfer coefficient was found to be 43.75% higher than that of the smooth tube. Also, the average flow boiling heat transfer coefficients of the EHT_HB and the EHT_DIM tubes were found to be 15% and 35% higher that of the smooth tube, respectively. From the perspective of the frictional pressure drop, it was found that the EHT_HB/DIM tube exhibited the maximum frictional pressure drop. The optimum working conditions of the enhanced tubes were determined by introducing a performance factor that captures the combined effects of heat transfer and pressure drop.
- Open Access
An Experimental Study of In-Tube Condensation and Evaporation Using Enhanced Heat Transfer (EHT) Tubes
A study was carried out to determine in-tube evaporation and condensation performance of enhanced heat transfer tubes (EHT) using R410A, with the results being compared to a plain tube. The test tubes considered in the evaluation include: plain, herringbone (HB) and spiral (HX) microgrooves, herringbone dimple (HB/D), and hydrophobic herringbone (HB/HY). Experiments to evaluate the condensation were conducted at a saturation of 318 K, and at 279 K for evaporation. Mass flux (G) ranged between 40 to 230 kg m−2s−1. Condensed vapor mass decreased from 0.8 to 0.2; and the mass of vaporized vapor increases from 0.2 to 0.8; heat flux increased with G. Inlet and outlet two-phase flow patterns at 200 kg m−2s−1 were recorded and analyzed. Enhanced tube heat transfer condensation performance (compared to a plain tube) increased in the range from 40% to 73%. The largest heat transfer increase is produced by the herringbone–dimple tube (HB/D). In addition to providing drainage, the herringbone groove also helps to lift the accumulated condensate to wet the surrounding wall. Evaporation thermal performance of the enhanced tubes are from 4% to 46% larger than that of smooth tube with the best performance being in the hydrophobic herringbone tube (HB/HY). This enhancement can be attributed to an increase in the number of nucleation sites and a larger heat transfer surface area. Evaporation and condensation correlations for heat transfer in smooth tubes is discussed and compared.
Open AccessAn Experimental Study of In-Tube Condensation and Evaporation Using Enhanced Heat Transfer (EHT) Tubes
A study was carried out to determine in-tube evaporation and condensation performance of enhanced heat transfer tubes (EHT) using R410A, with the results being compared to a plain tube. The test tubes considered in the evaluation include: plain, herringbone (HB) and spiral (HX) microgrooves, herringbone dimple (HB/D), and hydrophobic herringbone (HB/HY). Experiments to evaluate the condensation were conducted at a saturation of 318 K, and at 279 K for evaporation. Mass flux (G) ranged between 40 to 230 kg m−2s−1. Condensed vapor mass decreased from 0.8 to 0.2; and the mass of vaporized vapor increases from 0.2 to 0.8; heat flux increased with G. Inlet and outlet two-phase flow patterns at 200 kg m−2s−1 were recorded and analyzed. Enhanced tube heat transfer condensation performance (compared to a plain tube) increased in the range from 40% to 73%. The largest heat transfer increase is produced by the herringbone–dimple tube (HB/D). In addition to providing drainage, the herringbone groove also helps to lift the accumulated condensate to wet the surrounding wall. Evaporation thermal performance of the enhanced tubes are from 4% to 46% larger than that of smooth tube with the best performance being in the hydrophobic herringbone tube (HB/HY). This enhancement can be attributed to an increase in the number of nucleation sites and a larger heat transfer surface area. Evaporation and condensation correlations for heat transfer in smooth tubes is discussed and compared.