SYShiwu Yang

Shiwu Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Shiwu Yang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Arc Grounding Fault Detection Method in Distribution Networks Using Chaotic DC Waveform Recognition

    by Shiwu Yang, Qing Chen, Hongbin Li, Yang Jiao, Ruoyan Tian, Yuxiang He, Chuanji Zhang, Chang Liu

    Single-phase grounding faults (SPGFs) in distribution networks are often accompanied by electric arcs, making detection challenging due to irregular zero-sequence voltage and current. This article proposes a new method for detecting arc grounding faults (AGFs) in distribution networks using Toeplitz inverse covariance-based clustering (TICC) and dynamic time warping (DTW) to recognize chaotic direct current (CDC) waveform features. Initially, the article examines the asymmetry in current during AGF occurrences and concludes that asymmetric components persist throughout the fault duration. The concept of CDC is then proposed and obtained through specially designed sensors. Subsequently, the TICC algorithm is utilized to segment real-time CDC waveforms, extract the abnormal CDC waveform, and identify faulty lines. Finally, real-time AGF diagnosis of abnormal CDC waveforms is conducted using the DTW algorithm. By collecting data from a real substation in Jiangsu, China, and taking experiment verification in China ultrahigh voltage (UHV) Test Base, the results demonstrate that the classification accuracies for the training and test sets reached 96% and 100%, respectively, with the errors in diagnosing AGFs not exceeding 0.3 s. As a result, it enhances the safety and stability of power grid operations.


  • Analysis on the Zero Offset of a Microampere DC Current Sensor Using the Open-Loop Magnetic Modulator and the Suppression

    by Hongbin Li, Lei Zhou, Yang Jiao, Houda Zhu, Qing Chen, Shiwu Yang

    In a wide range of electrical applications, the requirement for noncontact measurement of weak direct currents is continuously increasing. Among all types of dc current sensors, the magnetic modulator (fluxgate) is more suitable for measuring weak dc currents due to its low noise and high stability. As the most common type, the open-loop magnetic modulator has made possible a current down to 1 mA to be measured, while the further development could be hardly made due to the zero offset. In this article, it is revealed that the difference in two-cores’ magnetic characteristics is the main root cause for the zero offset. With the subtraction loop used to describe this difference, keeping this loop symmetric could greatly weaken the zero offset. On this basis, a controlled-greed pairing strategy is proposed to control the zero offset at a rather low level by screening out two cores with similar magnetic offsets to form one magnetic modulator. Furthermore, the pairing experiment of 10 magnetic cores and the application case of 30 magnetic modulators are conducted. The results show that the pairing scheme obtained with the proposed strategy is better than the random pairing scheme in 98.863% of cases, and the average of zero offset decreases from 131.27 to $19.50 ~\mu \text{A}$ in mass production.


  • A Non-Contact Micro-Ampere DC Current Digital Sensor Based on the Open-Loop Structure

    by Lei Zhou, Qing Chen, Hongbin Li, Shiwu Yang, Dongxiao Pang, Hu Deng

    The non-contact accurate measurement of weak direct current (dc) is very important for various fields, such as the online insulation monitoring of power cables. Compared with other dc current sensors, the magnetic modulator is more suitable for dc measurement with its high sensitivity, low noise, and stable working. Most magnetic modulators adopt the closed-loop structure to achieve accurate measurement of large current. And the magnetic modulator only realized the accurate measurement of mA current in the filed of weak dc current, which is difficult to meet the μA current measurement requirements of the online insulation monitoring. Therefore, this paper proposes a new structure of open-loop digital magnetic modulator for precision measurement of μA dc current. It adopts an annular shielding layer to weaken the zero offset and stray magnetic field. And a low-frequency excitation source, which can be adjusted with the ambient temperature, is used to improve the temperature stability. Instead of the traditional analog demodulation method, a digital demodulation algorithm is designed to reduce the measurement error caused by the zero offset and excitation source fluctuation. Measurement results show that the new sensor with the absolute error of 0.5 μA can measure 5-1000 μA dc current with a relative error of 0.05% in the full scale. And the sensor can effectively suppress the measurement error caused by the fluctuation of the excitation source and the ambient temperature to less than 0.5%.