Lei Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Zhou has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Qing Chen
State Key Laboratory of Advanced Electromagnetic Technology, School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
5 shared publications - Yang Jiao
Huazhong University of Science and Technology
5 shared publications Hongbin Li
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
4 shared publications- Jing Zhang
School of Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Shiwu Yang
Institute of Artificial Intelligence, Huazhong University of Science and Technology, Wuhan, China
2 shared publications - Chaojun Ma
School of Electronics and Information Technology, Guangdong Provincial Key Laboratory of Optoelectronic Information Processing Chips and Systems, Sun Yat-sen University, Guangzhou, China
1 shared publication
Latest Publications
- 16 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6688-6696
A Sensor for the Ultraweak DC Current Covered by Strong AC Currents
In the field of insulation monitoring of high-voltage power equipment, the dc leakage current is an important indicator to evaluate the insulation state. However, μA-level dc leakage currents are usually mixed with mA-level power-frequency ac currents, bringing obstacles to the accuracy of the dc measurement. In this regard, a new magnetic modulator with the suppressing structure is proposed. Based on the fact that Lenz law only keeps valid for a changing magnetic flux, the ac suppressing structure is developed to enclose the original magnetic modulator. Then, the factors of the suppression structure’s performance, including weakening the ac magnetic flux and reducing the dc measurement sensitivity, have been analyzed. And the performance is found to be closely related to the magnet dimensions, the magnetic permeability and the suppressing winding turns. Finally, the improved prototype current sensor for the converter transformer valve side bushing has been developed, and experiments are conducted to verify its dc accuracy and ac suppressing performance.
- 16 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (7) , 6688-6696
A Sensor for the Ultraweak DC Current Covered by Strong AC Currents
In the field of insulation monitoring of high-voltage power equipment, the dc leakage current is an important indicator to evaluate the insulation state. However, μA-level dc leakage currents are usually mixed with mA-level power-frequency ac currents, bringing obstacles to the accuracy of the dc measurement. In this regard, a new magnetic modulator with the suppressing structure is proposed. Based on the fact that Lenz law only keeps valid for a changing magnetic flux, the ac suppressing structure is developed to enclose the original magnetic modulator. Then, the factors of the suppression structure’s performance, including weakening the ac magnetic flux and reducing the dc measurement sensitivity, have been analyzed. And the performance is found to be closely related to the magnet dimensions, the magnetic permeability and the suppressing winding turns. Finally, the improved prototype current sensor for the converter transformer valve side bushing has been developed, and experiments are conducted to verify its dc accuracy and ac suppressing performance.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18418-18427
Analysis on the Zero Offset of a Microampere DC Current Sensor Using the Open-Loop Magnetic Modulator and the Suppression
In a wide range of electrical applications, the requirement for noncontact measurement of weak direct currents is continuously increasing. Among all types of dc current sensors, the magnetic modulator (fluxgate) is more suitable for measuring weak dc currents due to its low noise and high stability. As the most common type, the open-loop magnetic modulator has made possible a current down to 1 mA to be measured, while the further development could be hardly made due to the zero offset. In this article, it is revealed that the difference in two-cores’ magnetic characteristics is the main root cause for the zero offset. With the subtraction loop used to describe this difference, keeping this loop symmetric could greatly weaken the zero offset. On this basis, a controlled-greed pairing strategy is proposed to control the zero offset at a rather low level by screening out two cores with similar magnetic offsets to form one magnetic modulator. Furthermore, the pairing experiment of 10 magnetic cores and the application case of 30 magnetic modulators are conducted. The results show that the pairing scheme obtained with the proposed strategy is better than the random pairing scheme in 98.863% of cases, and the average of zero offset decreases from 131.27 to $19.50 ~\mu \text{A}$ in mass production.
- 26 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (19) , 18418-18427
Analysis on the Zero Offset of a Microampere DC Current Sensor Using the Open-Loop Magnetic Modulator and the Suppression
In a wide range of electrical applications, the requirement for noncontact measurement of weak direct currents is continuously increasing. Among all types of dc current sensors, the magnetic modulator (fluxgate) is more suitable for measuring weak dc currents due to its low noise and high stability. As the most common type, the open-loop magnetic modulator has made possible a current down to 1 mA to be measured, while the further development could be hardly made due to the zero offset. In this article, it is revealed that the difference in two-cores’ magnetic characteristics is the main root cause for the zero offset. With the subtraction loop used to describe this difference, keeping this loop symmetric could greatly weaken the zero offset. On this basis, a controlled-greed pairing strategy is proposed to control the zero offset at a rather low level by screening out two cores with similar magnetic offsets to form one magnetic modulator. Furthermore, the pairing experiment of 10 magnetic cores and the application case of 30 magnetic modulators are conducted. The results show that the pairing scheme obtained with the proposed strategy is better than the random pairing scheme in 98.863% of cases, and the average of zero offset decreases from 131.27 to $19.50 ~\mu \text{A}$ in mass production.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 24, 1-6
An Optimization Design of the Iron-core Coil Sensor for High-frequency Current Signals
In a wide range of electrical applications, an accurate measurement of the high-frequency current signal is urgently required. Owing to inherent superiorities, iron-core coils have been widely applied to the measurement of high-frequency current signals. Nevertheless, the uneven winding, bandwidth-sensitivity exclusion, and partial resonances have restrict better high-frequency characteristics. To address the issues, an optimization design is proposed in this paper, and it includes three key improvements: the Core-PCB hybrid structure, staggered secondary winding, and distributed sampling resistances, which respectively contribute to better uniformity of winding, smaller stray capacitances, and effective suppression on partial resonances. Moreover, simulations and tests are conducted, and the results verify the validity.
- 16 May 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 24, 1-6
An Optimization Design of the Iron-core Coil Sensor for High-frequency Current Signals
In a wide range of electrical applications, an accurate measurement of the high-frequency current signal is urgently required. Owing to inherent superiorities, iron-core coils have been widely applied to the measurement of high-frequency current signals. Nevertheless, the uneven winding, bandwidth-sensitivity exclusion, and partial resonances have restrict better high-frequency characteristics. To address the issues, an optimization design is proposed in this paper, and it includes three key improvements: the Core-PCB hybrid structure, staggered secondary winding, and distributed sampling resistances, which respectively contribute to better uniformity of winding, smaller stray capacitances, and effective suppression on partial resonances. Moreover, simulations and tests are conducted, and the results verify the validity.
- 22 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (1) , 980-988
An Online Measuring Method for Tangent Delta of Power Cables Based on an Injected Very-Low-Frequency Signal
The deterioration of cable insulation is a widely acknowledged problem, and detection lays the foundation for maintenance and overhaul. The measurement of Tangent delta (tan $\boldsymbol {\delta }$ ) at very low frequency (VLF) works well on cable insulation detection, nevertheless the conventional method could only be conducted offline, where the power outage is usually required, interrupting the normal operation. To break thus a limitation, an advanced online method is proposed, and tan $\boldsymbol {\delta }$ would be calculated based on the measurement of an artificially injected VLF voltage and that of the VLF leakage current through cable insulation. To coordinate with this method, an injecting source, with the comprehensive self-protection and the by-pass channel for power-frequency signals, is developed to safely inject a VLF voltage to the power system, and a monitoring system, with an accuracy better than $\pm 0.3~\boldsymbol {\mu }\text{A}$ , is established to obtain the injected voltage’s and leakage current’s waveforms, which would be used to further calculate tan $\boldsymbol {\delta }$ with the cross-correlation algorithm. In addition, this method, as well as developed devices, is applied on several cables in China Electric Power Research Institute, and the measuring results keep consistent with the actual conditions, which verifies the validity.
- 22 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 22 (1) , 980-988
An Online Measuring Method for Tangent Delta of Power Cables Based on an Injected Very-Low-Frequency Signal
The deterioration of cable insulation is a widely acknowledged problem, and detection lays the foundation for maintenance and overhaul. The measurement of Tangent delta (tan $\boldsymbol {\delta }$ ) at very low frequency (VLF) works well on cable insulation detection, nevertheless the conventional method could only be conducted offline, where the power outage is usually required, interrupting the normal operation. To break thus a limitation, an advanced online method is proposed, and tan $\boldsymbol {\delta }$ would be calculated based on the measurement of an artificially injected VLF voltage and that of the VLF leakage current through cable insulation. To coordinate with this method, an injecting source, with the comprehensive self-protection and the by-pass channel for power-frequency signals, is developed to safely inject a VLF voltage to the power system, and a monitoring system, with an accuracy better than $\pm 0.3~\boldsymbol {\mu }\text{A}$ , is established to obtain the injected voltage’s and leakage current’s waveforms, which would be used to further calculate tan $\boldsymbol {\delta }$ with the cross-correlation algorithm. In addition, this method, as well as developed devices, is applied on several cables in China Electric Power Research Institute, and the measuring results keep consistent with the actual conditions, which verifies the validity.
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-163
Multi-Band Field-Circuit Coupling Analysis Method for Very Fast Transient Overvoltage
Very fast transient overvoltage (VFTO) is one of the most serious threats to gas insulated substations (GIS), while its formation mechanism has not been analyzed clearly by existing methods. Aimed at solving this problem, this paper proposes a multi-band field-circuit coupling analysis method from the perspective of energy exchange. To validate the proposed method's effectiveness, three equivalent models with different principle types are established to accurately model the GIS system, and a field test is conducted in China Electric Power Research Institute. The experimental results show that the measured waveforms are close to the simulation waveforms in the time domain, and the proposed method could accurately analyze VFTO in the full frequency domain.
- 29 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 157-163
Multi-Band Field-Circuit Coupling Analysis Method for Very Fast Transient Overvoltage
Very fast transient overvoltage (VFTO) is one of the most serious threats to gas insulated substations (GIS), while its formation mechanism has not been analyzed clearly by existing methods. Aimed at solving this problem, this paper proposes a multi-band field-circuit coupling analysis method from the perspective of energy exchange. To validate the proposed method's effectiveness, three equivalent models with different principle types are established to accurately model the GIS system, and a field test is conducted in China Electric Power Research Institute. The experimental results show that the measured waveforms are close to the simulation waveforms in the time domain, and the proposed method could accurately analyze VFTO in the full frequency domain.
- 9 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 5923-5931
A Non-Contact Micro-Ampere DC Current Digital Sensor Based on the Open-Loop Structure
The non-contact accurate measurement of weak direct current (dc) is very important for various fields, such as the online insulation monitoring of power cables. Compared with other dc current sensors, the magnetic modulator is more suitable for dc measurement with its high sensitivity, low noise, and stable working. Most magnetic modulators adopt the closed-loop structure to achieve accurate measurement of large current. And the magnetic modulator only realized the accurate measurement of mA current in the filed of weak dc current, which is difficult to meet the μA current measurement requirements of the online insulation monitoring. Therefore, this paper proposes a new structure of open-loop digital magnetic modulator for precision measurement of μA dc current. It adopts an annular shielding layer to weaken the zero offset and stray magnetic field. And a low-frequency excitation source, which can be adjusted with the ambient temperature, is used to improve the temperature stability. Instead of the traditional analog demodulation method, a digital demodulation algorithm is designed to reduce the measurement error caused by the zero offset and excitation source fluctuation. Measurement results show that the new sensor with the absolute error of 0.5 μA can measure 5-1000 μA dc current with a relative error of 0.05% in the full scale. And the sensor can effectively suppress the measurement error caused by the fluctuation of the excitation source and the ambient temperature to less than 0.5%.
- 9 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 21 (5) , 5923-5931
A Non-Contact Micro-Ampere DC Current Digital Sensor Based on the Open-Loop Structure
The non-contact accurate measurement of weak direct current (dc) is very important for various fields, such as the online insulation monitoring of power cables. Compared with other dc current sensors, the magnetic modulator is more suitable for dc measurement with its high sensitivity, low noise, and stable working. Most magnetic modulators adopt the closed-loop structure to achieve accurate measurement of large current. And the magnetic modulator only realized the accurate measurement of mA current in the filed of weak dc current, which is difficult to meet the μA current measurement requirements of the online insulation monitoring. Therefore, this paper proposes a new structure of open-loop digital magnetic modulator for precision measurement of μA dc current. It adopts an annular shielding layer to weaken the zero offset and stray magnetic field. And a low-frequency excitation source, which can be adjusted with the ambient temperature, is used to improve the temperature stability. Instead of the traditional analog demodulation method, a digital demodulation algorithm is designed to reduce the measurement error caused by the zero offset and excitation source fluctuation. Measurement results show that the new sensor with the absolute error of 0.5 μA can measure 5-1000 μA dc current with a relative error of 0.05% in the full scale. And the sensor can effectively suppress the measurement error caused by the fluctuation of the excitation source and the ambient temperature to less than 0.5%.