Chengjia Lu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Chengjia Lu has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Qingyun Chang
Qingdao University
6 shared publications - Jiaxing Lei
School of Electrical Engineering, Southeast University, Nanjing 210096, China
5 shared publications - Bo Zhou
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
4 shared publications - Xingwei Zhou
School of Electrical and Power Engineering, Hohai University, Nanjing, China
3 shared publications Bo Zhou
Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications- Jiadan Wei
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications
Latest Publications
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3087-3098
Active-Power-Decoupling Matrix-Type Back-to-Back Converter
Matrix converters (MCs) face application limitation due to numerous switching devices and input-output power coupling characteristics. This paper proposes an active-powerdecoupling matrix-type back-to-back converter (APD-MTBBC), which reduces the switching device count from 18 to 14 while achieving input-output fluctuating power decoupling to suppress input current distortions under unbalanced load conditions. First, the four-leg output MTBBC and its control strategy under unbalanced load conditions are analyzed, with specific focus on how the second-harmonic component in the load power causes input current harmonics. Secondly, the APD technology is introduced into the MTBBC by multiplexing the fourth output leg to construct an APD branch, which generates second-harmonic power to offset the second-harmonic component in the load power. Then, based on the spectrum analysis of the APD branch, an APD control strategy consisting of an input power outer loop, an APD branch current inner loop and an output power feedforward loop is developed to achieve fluctuating power decoupling between the input and output, thereby ensuring constant input power and sinusoidal input current. Finally, experimental results validate the efficacy of the proposed topology and control strategy. Though implemented in the MTBBC, the proposed APD technique is extendable to other indirect MC topologies.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3087-3098
Active-Power-Decoupling Matrix-Type Back-to-Back Converter
Matrix converters (MCs) face application limitation due to numerous switching devices and input-output power coupling characteristics. This paper proposes an active-powerdecoupling matrix-type back-to-back converter (APD-MTBBC), which reduces the switching device count from 18 to 14 while achieving input-output fluctuating power decoupling to suppress input current distortions under unbalanced load conditions. First, the four-leg output MTBBC and its control strategy under unbalanced load conditions are analyzed, with specific focus on how the second-harmonic component in the load power causes input current harmonics. Secondly, the APD technology is introduced into the MTBBC by multiplexing the fourth output leg to construct an APD branch, which generates second-harmonic power to offset the second-harmonic component in the load power. Then, based on the spectrum analysis of the APD branch, an APD control strategy consisting of an input power outer loop, an APD branch current inner loop and an output power feedforward loop is developed to achieve fluctuating power decoupling between the input and output, thereby ensuring constant input power and sinusoidal input current. Finally, experimental results validate the efficacy of the proposed topology and control strategy. Though implemented in the MTBBC, the proposed APD technique is extendable to other indirect MC topologies.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (3) , 328-332
A Hybrid Signal and Model-Based Fault Diagnostic Strategy for Current Sensors in Six-Phase Sinusoidal Doubly Salient Electro-Magnetic Machines
To enhance the diagnosis capability of current sensor faults in symmetrical six-phase sinusoidal doubly salient electromagnetic machines (SDSEM) system, a hybrid signal and model-based diagnosis strategy is proposed in this paper. At first, the current sensor fault operating characteristic is investigated, and the features of z1-z2 subspace currents are analyzed in detail. Then, on the base of the currents feature, a novel phase current sensor fault diagnostic strategy is proposed, most of the faulty phase current sensor can be diagnosed according to the changes in the diagnosis signals which are constructed from z1-z2 subspace currents. In further, to distinguish the blind spot caused by the symmetrical windings with 60° phase shift, an easy-implemented model-based current observer is designed, the faulty phase current sensor can be further identified according to the difference between the sampled and observed currents. With the combined hybrid signal and model-based diagnosis strategy, accurate discriminations of phase current sensor fault are desired to be achieved. The multiple experiments validate the correctness and the feasibility of the proposed methods.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 73 (3) , 328-332
A Hybrid Signal and Model-Based Fault Diagnostic Strategy for Current Sensors in Six-Phase Sinusoidal Doubly Salient Electro-Magnetic Machines
To enhance the diagnosis capability of current sensor faults in symmetrical six-phase sinusoidal doubly salient electromagnetic machines (SDSEM) system, a hybrid signal and model-based diagnosis strategy is proposed in this paper. At first, the current sensor fault operating characteristic is investigated, and the features of z1-z2 subspace currents are analyzed in detail. Then, on the base of the currents feature, a novel phase current sensor fault diagnostic strategy is proposed, most of the faulty phase current sensor can be diagnosed according to the changes in the diagnosis signals which are constructed from z1-z2 subspace currents. In further, to distinguish the blind spot caused by the symmetrical windings with 60° phase shift, an easy-implemented model-based current observer is designed, the faulty phase current sensor can be further identified according to the difference between the sampled and observed currents. With the combined hybrid signal and model-based diagnosis strategy, accurate discriminations of phase current sensor fault are desired to be achieved. The multiple experiments validate the correctness and the feasibility of the proposed methods.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3743-3752
Torque Performance Improving Strategy for DSEM Based on Adaptive Given Proportion Harmonic Currents
Doubly salient electromagnetic machine (DSEM) is traditionally driven by the quasi-square current waveform, but this easy-implemented conduction strategy limits the torque performance improvement. In this article, based on the analysis of the outputting torque components, the nonlinear harmonic mathematic model of DSEM is first established. Then, based on this, the ideal optimal command armature currents for the maximum torque per ampere (MTPA) control of DSEM are mathematically deduced with the Lagrange multiplier method, in which the harmonic is innovatively fully used. Afterward, taking the actual implementation into overall consideration, the torque contribution of different order harmonics is explored, and the first- and second-order harmonic currents are selected to be injected in practice. Furthermore, the influence of DSEM magnetic saturation on the injected harmonic currents is investigated, and an adaptive compensation strategy is designed to online achieve the optimal conduction currents, thus the torque performance can be desired to be enhanced. Finally, the correctness and the feasibility of the proposed methods are experimentally verified on a 12/8-pole DSEM prototype.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3743-3752
Torque Performance Improving Strategy for DSEM Based on Adaptive Given Proportion Harmonic Currents
Doubly salient electromagnetic machine (DSEM) is traditionally driven by the quasi-square current waveform, but this easy-implemented conduction strategy limits the torque performance improvement. In this article, based on the analysis of the outputting torque components, the nonlinear harmonic mathematic model of DSEM is first established. Then, based on this, the ideal optimal command armature currents for the maximum torque per ampere (MTPA) control of DSEM are mathematically deduced with the Lagrange multiplier method, in which the harmonic is innovatively fully used. Afterward, taking the actual implementation into overall consideration, the torque contribution of different order harmonics is explored, and the first- and second-order harmonic currents are selected to be injected in practice. Furthermore, the influence of DSEM magnetic saturation on the injected harmonic currents is investigated, and an adaptive compensation strategy is designed to online achieve the optimal conduction currents, thus the torque performance can be desired to be enhanced. Finally, the correctness and the feasibility of the proposed methods are experimentally verified on a 12/8-pole DSEM prototype.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6604-6614
Improved Three-Level Third-Harmonic Current Injection Active Filter Circuit for the Three-Phase Diode Rectifier in Aircraft
Three-phase uncontrolled rectifiers have been widely adopted due to the characteristics of robustness and high efficiency, but have the disadvantage of harmonic pollution. Third-harmonic current injection (3rd-HCI) active filter circuit could remove the harmonics. However, new problems occur and lead to current distortions again when the ac line frequency increases, especially in the more electric aircraft applications where the ac line frequency is 360–800 Hz. In this article, the mechanism of current distortions at higher ac line frequency is discussed first. The inductor in the 3rd-HCI active filter circuit is volt-second imbalance. As the ac line frequency increases, the imbalance degree is more severe and then causes current distortions. Therefore, the inductance must be reduced, resulting in larger current ripple and more high-frequency components in the ac line current. Further, based on flying capacitor three-level topology, this article proposed an improved 3rd-HCI active filter circuit and the corresponding control strategy, which not only reduces the current ripple significantly but also mitigates the ac line current distortions. Besides, the input filter capacitive current compensation is also considered to improve the power factor at light load. Finally, all the analysis are verified by experimental results on a 115 Vrms/360–800 Hz/5 kW prototype.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6604-6614
Improved Three-Level Third-Harmonic Current Injection Active Filter Circuit for the Three-Phase Diode Rectifier in Aircraft
Three-phase uncontrolled rectifiers have been widely adopted due to the characteristics of robustness and high efficiency, but have the disadvantage of harmonic pollution. Third-harmonic current injection (3rd-HCI) active filter circuit could remove the harmonics. However, new problems occur and lead to current distortions again when the ac line frequency increases, especially in the more electric aircraft applications where the ac line frequency is 360–800 Hz. In this article, the mechanism of current distortions at higher ac line frequency is discussed first. The inductor in the 3rd-HCI active filter circuit is volt-second imbalance. As the ac line frequency increases, the imbalance degree is more severe and then causes current distortions. Therefore, the inductance must be reduced, resulting in larger current ripple and more high-frequency components in the ac line current. Further, based on flying capacitor three-level topology, this article proposed an improved 3rd-HCI active filter circuit and the corresponding control strategy, which not only reduces the current ripple significantly but also mitigates the ac line current distortions. Besides, the input filter capacitive current compensation is also considered to improve the power factor at light load. Finally, all the analysis are verified by experimental results on a 115 Vrms/360–800 Hz/5 kW prototype.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5764-5775
Analysis and Design of Third-Harmonic Current Injection Active Filter Circuit for the Aircraft
Third-harmonic current injection (3rd-HCI) active filter circuit could be utilized to eliminate low frequency harmonics generated by the three-phase uncontrolled rectifier. However, some problems exist when the circuit operates in the 115Vrms/400Hz aircraft power system. The inductor in the 3rd-HCI active filter circuit is not strictly volt-second balance in one switching period, resulting in injection current error and AC line current distortions. The problem is more severe in the 400Hz power system since the imbalance degree increases with a higher AC frequency. Moreover, the common method to mitigate the AC line current distortions is using a smaller inductor, which will increase the inductor current ripple and high frequency harmonic components. This paper investigates the distortion mechanisms and reveals the relationship between current distortion and volt-second imbalance, and the maximum allowed inductance is determined under every operating point. Then, an improved circuit based on ripple current cancellation technique is proposed to realize quasi-zero ripple in the inductor current and to reduce the high frequency harmonics in the AC line currents, which extends the operating range of the circuit significantly. Finally, the correctness of analysis and validity of proposed circuit are verified by experimental results based on a 115Vrms/400Hz/5kW prototype.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5764-5775
Analysis and Design of Third-Harmonic Current Injection Active Filter Circuit for the Aircraft
Third-harmonic current injection (3rd-HCI) active filter circuit could be utilized to eliminate low frequency harmonics generated by the three-phase uncontrolled rectifier. However, some problems exist when the circuit operates in the 115Vrms/400Hz aircraft power system. The inductor in the 3rd-HCI active filter circuit is not strictly volt-second balance in one switching period, resulting in injection current error and AC line current distortions. The problem is more severe in the 400Hz power system since the imbalance degree increases with a higher AC frequency. Moreover, the common method to mitigate the AC line current distortions is using a smaller inductor, which will increase the inductor current ripple and high frequency harmonic components. This paper investigates the distortion mechanisms and reveals the relationship between current distortion and volt-second imbalance, and the maximum allowed inductance is determined under every operating point. Then, an improved circuit based on ripple current cancellation technique is proposed to realize quasi-zero ripple in the inductor current and to reduce the high frequency harmonics in the AC line currents, which extends the operating range of the circuit significantly. Finally, the correctness of analysis and validity of proposed circuit are verified by experimental results based on a 115Vrms/400Hz/5kW prototype.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (4) , 3839-3852
Control Scheme Based on Improved Odd-Harmonic Repetitive Control for Third-Harmonic Injection Two-Stage Matrix Converter
The third-harmonic injection two-stage matrix converter (3TSMC) not only inherits the advantages of the conventional two-stage matrix converter (TSMC), but also has simple modulation strategy and low switching losses. The injection current control is the key to achieving sinusoidal input currents of 3TSMC. The injection current reference consists of the third harmonic and its odd harmonics, making it difficult to obtain high control accuracy with a proportional integral (PI) controller. In this paper, a control scheme is proposed for the injection current of 3TSMC, which consists of an improved odd-harmonic repetitive controller (IORC), a PI controller and a feedforward controller. Compared with the conventional repetitive controller (CRC) and existing odd-harmonic repetitive controllers (ORC), the IORC has the highest gains and bandwidths at odd-harmonic frequencies, offering the proposed control scheme high control accuracy and fast transient response. The stability conditions of the system with the proposed control scheme are analyzed, and the design guidelines for the control parameters are provided on this basis. The experimental results demonstrate the effectiveness of the proposed control scheme.
- 24 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 11 (4) , 3839-3852
Control Scheme Based on Improved Odd-Harmonic Repetitive Control for Third-Harmonic Injection Two-Stage Matrix Converter
The third-harmonic injection two-stage matrix converter (3TSMC) not only inherits the advantages of the conventional two-stage matrix converter (TSMC), but also has simple modulation strategy and low switching losses. The injection current control is the key to achieving sinusoidal input currents of 3TSMC. The injection current reference consists of the third harmonic and its odd harmonics, making it difficult to obtain high control accuracy with a proportional integral (PI) controller. In this paper, a control scheme is proposed for the injection current of 3TSMC, which consists of an improved odd-harmonic repetitive controller (IORC), a PI controller and a feedforward controller. Compared with the conventional repetitive controller (CRC) and existing odd-harmonic repetitive controllers (ORC), the IORC has the highest gains and bandwidths at odd-harmonic frequencies, offering the proposed control scheme high control accuracy and fast transient response. The stability conditions of the system with the proposed control scheme are analyzed, and the design guidelines for the control parameters are provided on this basis. The experimental results demonstrate the effectiveness of the proposed control scheme.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (6) , 6983-6995
Modulation Strategy for the 3TSMC to Suppress Mains Current Sector-Switching Distortions Under Capacitive Input Power Factor Angles
In this paper, a modulation strategy is proposed for the third-harmonic injection two-stage matrix converter (3TSMC) to suppress the mains current sector-switching distortions under capacitive input power factor angles. First, it is revealed that when the 3TSMC operates under non-unity input power factors, the injection current has control errors after sector switching, which cannot be completely solved by optimizing the controller. Second, the mechanism that the injection current control errors lead to the mains current distortions is analyzed, and the shapes of distortions are summarized. Then, a novel switching pattern is introduced for the input voltage selector (IVS) of the 3TSMC, which can weaken or even offset the distortions generated by the control errors under capacitive input power factor angles. The proposed modulation strategy inserts this switching pattern into the original switching sequence with a suitable duty cycle after sector switching, thus suppressing the distortions. Finally, experimental results are presented to verify the validity of the proposed modulation strategy.
- 20 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (6) , 6983-6995
Modulation Strategy for the 3TSMC to Suppress Mains Current Sector-Switching Distortions Under Capacitive Input Power Factor Angles
In this paper, a modulation strategy is proposed for the third-harmonic injection two-stage matrix converter (3TSMC) to suppress the mains current sector-switching distortions under capacitive input power factor angles. First, it is revealed that when the 3TSMC operates under non-unity input power factors, the injection current has control errors after sector switching, which cannot be completely solved by optimizing the controller. Second, the mechanism that the injection current control errors lead to the mains current distortions is analyzed, and the shapes of distortions are summarized. Then, a novel switching pattern is introduced for the input voltage selector (IVS) of the 3TSMC, which can weaken or even offset the distortions generated by the control errors under capacitive input power factor angles. The proposed modulation strategy inserts this switching pattern into the original switching sequence with a suitable duty cycle after sector switching, thus suppressing the distortions. Finally, experimental results are presented to verify the validity of the proposed modulation strategy.
- 8 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (7) , 7846-7857
Improved Third-Harmonic Injection Two-Stage Matrix Converter Topology Based on Decomposition Control of Injection Current
In this article, an improved topology of the third-harmonic injection two-stage matrix converter (3TSMC) is proposed, which not only ensures that the input reactive power control capability is independent of the voltage transfer ratio (VTR) and the load conditions but also achieves high-quality mains current waveforms. To solve the problem of injection current control error in nonunit input power factor operation of 3TSMC, the third-harmonic injection current is decomposed into the active and reactive components, which are, respectively, controlled by the original injection current control bridge arm and an additional bridge arm named reactive power control bridge arm (RB). The maximum current of the inductor of RB is equal to the absolute value of the required input reactive current amplitude and will not increase with the increase of the VTR. The design criteria of the inductor of RB are discussed. To ensure the closed-loop stability under two injection directions, the controller of the injection current reactive component is designed. The effectiveness of the proposed topology and control strategy is verified by the experimental results.
- 8 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 37 (7) , 7846-7857
Improved Third-Harmonic Injection Two-Stage Matrix Converter Topology Based on Decomposition Control of Injection Current
In this article, an improved topology of the third-harmonic injection two-stage matrix converter (3TSMC) is proposed, which not only ensures that the input reactive power control capability is independent of the voltage transfer ratio (VTR) and the load conditions but also achieves high-quality mains current waveforms. To solve the problem of injection current control error in nonunit input power factor operation of 3TSMC, the third-harmonic injection current is decomposed into the active and reactive components, which are, respectively, controlled by the original injection current control bridge arm and an additional bridge arm named reactive power control bridge arm (RB). The maximum current of the inductor of RB is equal to the absolute value of the required input reactive current amplitude and will not increase with the increase of the VTR. The design criteria of the inductor of RB are discussed. To ensure the closed-loop stability under two injection directions, the controller of the injection current reactive component is designed. The effectiveness of the proposed topology and control strategy is verified by the experimental results.
- 23 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (6) , 7202-7211
Mains Current Distortion Suppression for Third-Harmonic Injection Two-Stage Matrix Converter
The third-harmonic injection two-stage matrix converter (3TSMC) not only possesses the advantages of a TSMC, but also enhances the input reactive power control capability. Due to the input current deviation caused by the voltage ripple across the input filter capacitors, the mains currents of the 3TSMC are distorted at sector boundaries. To improve mains current quality, this article proposes a mains current distortion suppression method for a 3TSMC, which adds a prefilter to the output side of the input voltage selector to reduce the input current harmonics. As a result, the input filter capacitor voltage ripple and the input current deviation are reduced. The details of design of the prefilter are explained mathematically. To compensate for the dc-link voltage variation after topology improvement, an algorithm based on calculation of the voltage drops across the prefilter inductors is proposed, which can further improve the mains current performance. The feasibility of the proposed method is verified by simulation and experimental results.
- 23 November 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 36 (6) , 7202-7211
Mains Current Distortion Suppression for Third-Harmonic Injection Two-Stage Matrix Converter
The third-harmonic injection two-stage matrix converter (3TSMC) not only possesses the advantages of a TSMC, but also enhances the input reactive power control capability. Due to the input current deviation caused by the voltage ripple across the input filter capacitors, the mains currents of the 3TSMC are distorted at sector boundaries. To improve mains current quality, this article proposes a mains current distortion suppression method for a 3TSMC, which adds a prefilter to the output side of the input voltage selector to reduce the input current harmonics. As a result, the input filter capacitor voltage ripple and the input current deviation are reduced. The details of design of the prefilter are explained mathematically. To compensate for the dc-link voltage variation after topology improvement, an algorithm based on calculation of the voltage drops across the prefilter inductors is proposed, which can further improve the mains current performance. The feasibility of the proposed method is verified by simulation and experimental results.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Active Damping Control Strategy of Hybrid Active Third-Harmonic Injection Matrix Converter via Modifying Third-Harmonic Injection Reference Current and Output Reference Current
In this paper, an active damping control strategy based on modifying third-harmonic injection reference current and output reference current is proposed for hybrid active third-harmonic injection matrix converter (H3IMC) to improve system instability. First, the system stability when H3IMC adopts no damping methods and passive damping method is analyzed through small-signal modeling and root locus analysis. Then, the active damping method based on virtual damping branch is applied to H3IMC. A specific implementation method based on the modification of reference third harmonic injection current is proposed, which can realize active damping control strategy directly and effectively by injecting the damping signal into the reference third harmonic injection current, and avoid the problem of reducing the control freedom of the output side. Finally, simulation results illustrate that, under the condition of the same parameters, the proposed active damping control strategy performs the same as passive damping control in damping at source side and better in filtering.
- 1 August 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Active Damping Control Strategy of Hybrid Active Third-Harmonic Injection Matrix Converter via Modifying Third-Harmonic Injection Reference Current and Output Reference Current
In this paper, an active damping control strategy based on modifying third-harmonic injection reference current and output reference current is proposed for hybrid active third-harmonic injection matrix converter (H3IMC) to improve system instability. First, the system stability when H3IMC adopts no damping methods and passive damping method is analyzed through small-signal modeling and root locus analysis. Then, the active damping method based on virtual damping branch is applied to H3IMC. A specific implementation method based on the modification of reference third harmonic injection current is proposed, which can realize active damping control strategy directly and effectively by injecting the damping signal into the reference third harmonic injection current, and avoid the problem of reducing the control freedom of the output side. Finally, simulation results illustrate that, under the condition of the same parameters, the proposed active damping control strategy performs the same as passive damping control in damping at source side and better in filtering.