Qingyun Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Qingyun Chang has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Bo Zhou
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
10 shared publications - Chengjia Lu
Nanjing Normal University, Nanjing, China
6 shared publications - Jiadan Wei
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
5 shared publications - Yi Lu
College of Information Science and Technology Artificial Intelligence, Nanjing Forestry University, Nanjing, China
5 shared publications - Jiaxing Lei
School of Electrical Engineering, Southeast University, Nanjing 210096, China
3 shared publications Bo Zhou
Jiangsu Key Laboratory of New Energy Generation and Power Conversion, College of Automation Engineering, Nanjing University of Aeronautics and Astronautics, Nanjing, China
2 shared publications
Latest Publications
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 26401-26412
A Comprehensive Diagnosis and Fault-Tolerant Control Method for Multiple Current Sensor Faults in Multiphase PMSM Drives
- 1 September 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (17) , 26401-26412
A Comprehensive Diagnosis and Fault-Tolerant Control Method for Multiple Current Sensor Faults in Multiphase PMSM Drives
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System
This paper proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. Firstly, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.
- 27 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
A Fault Diagnosis and Fault-Tolerant Control Method for Open-Circuit Fault of Excitation Winding Converter in DSEM Drive System
This paper proposes a fault location and fault-tolerant control method for the open-circuit fault of the excitation winding converter in the doubly salient electromagnetic motor (DSEM) drive system. Firstly, by rearranging the placement of the excitation current sensor and analyzing the change characteristics of the sampled current values before and after the excitation winding converter open-circuit fault, the faulty switch is quickly located. Then, fault-tolerant control strategies for the armature winding and excitation winding converter are designed for open-circuit faults in the excitation winding converter switches at different locations. This ensures that the output torque of the DSEM remains unchanged before and after fault-tolerant control, thus guaranteeing smooth motor operation. Simultaneously, the switching moment of the armature winding converter control strategy is optimized after the occurrence of the excitation winding converter open-circuit fault, in order to prevent the motor from outputting negative torque during the switching process. The proposed method can rapidly locate the faulty switch in the excitation winding converter without the need for additional sensors. It ensures that the motor maintains a consistent output torque before and after fault-tolerant operation, thereby guaranteeing the load-carrying capability of the motor. Finally, experiments conducted on a 12/8 three-phase DSEM verify the effectiveness and practicality of the proposed method.
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 812-821
A Novel Small Capacitor DSEM Drive System With Bus Voltage Ripple Suppression Effect
- 1 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (1) , 812-821
A Novel Small Capacitor DSEM Drive System With Bus Voltage Ripple Suppression Effect
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6744-6756
A Two-Step Online Diagnosis Strategy for Open-Phase Fault in Doubly Salient Electromagnetic Motor Drives
Open-phase fault is a common fault in motor drives and occurs as the phase winding is disconnected or one leg of the converter bridge fails, which may generate significant torque ripple and reduce the output torque of the motor. To enhance the reliability of the system, this article proposes a two-step online diagnosis strategy for open-phase faults in doubly salient electromagnetic motor (DSEM) drives. In the first step, the occurrence of open-phase fault is detected based on the variation of active phase currents under normal and fault conditions. In the second step, the differentiation of two fault types (phase-winding open-circuit faults and two-switch open-circuit faults in the same bridge leg) as well as the localization of the fault phase winding can be realized by analyzing the variation of the zero-sequence voltage component (ZSVC) in the fault sector. And combined with the two-phase energization characteristic of the DSEM, the fault bridge leg can be localized based on the changes of the working phase currents within the fault sector and its subsequent sector. Finally, the effectiveness of the proposed method is experimentally verified on a 12/8-pole DSEM system.
- 14 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (5) , 6744-6756
A Two-Step Online Diagnosis Strategy for Open-Phase Fault in Doubly Salient Electromagnetic Motor Drives
Open-phase fault is a common fault in motor drives and occurs as the phase winding is disconnected or one leg of the converter bridge fails, which may generate significant torque ripple and reduce the output torque of the motor. To enhance the reliability of the system, this article proposes a two-step online diagnosis strategy for open-phase faults in doubly salient electromagnetic motor (DSEM) drives. In the first step, the occurrence of open-phase fault is detected based on the variation of active phase currents under normal and fault conditions. In the second step, the differentiation of two fault types (phase-winding open-circuit faults and two-switch open-circuit faults in the same bridge leg) as well as the localization of the fault phase winding can be realized by analyzing the variation of the zero-sequence voltage component (ZSVC) in the fault sector. And combined with the two-phase energization characteristic of the DSEM, the fault bridge leg can be localized based on the changes of the working phase currents within the fault sector and its subsequent sector. Finally, the effectiveness of the proposed method is experimentally verified on a 12/8-pole DSEM system.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3087-3098
Active-Power-Decoupling Matrix-Type Back-to-Back Converter
Matrix converters (MCs) face application limitation due to numerous switching devices and input-output power coupling characteristics. This paper proposes an active-powerdecoupling matrix-type back-to-back converter (APD-MTBBC), which reduces the switching device count from 18 to 14 while achieving input-output fluctuating power decoupling to suppress input current distortions under unbalanced load conditions. First, the four-leg output MTBBC and its control strategy under unbalanced load conditions are analyzed, with specific focus on how the second-harmonic component in the load power causes input current harmonics. Secondly, the APD technology is introduced into the MTBBC by multiplexing the fourth output leg to construct an APD branch, which generates second-harmonic power to offset the second-harmonic component in the load power. Then, based on the spectrum analysis of the APD branch, an APD control strategy consisting of an input power outer loop, an APD branch current inner loop and an output power feedforward loop is developed to achieve fluctuating power decoupling between the input and output, thereby ensuring constant input power and sinusoidal input current. Finally, experimental results validate the efficacy of the proposed topology and control strategy. Though implemented in the MTBBC, the proposed APD technique is extendable to other indirect MC topologies.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3087-3098
Active-Power-Decoupling Matrix-Type Back-to-Back Converter
Matrix converters (MCs) face application limitation due to numerous switching devices and input-output power coupling characteristics. This paper proposes an active-powerdecoupling matrix-type back-to-back converter (APD-MTBBC), which reduces the switching device count from 18 to 14 while achieving input-output fluctuating power decoupling to suppress input current distortions under unbalanced load conditions. First, the four-leg output MTBBC and its control strategy under unbalanced load conditions are analyzed, with specific focus on how the second-harmonic component in the load power causes input current harmonics. Secondly, the APD technology is introduced into the MTBBC by multiplexing the fourth output leg to construct an APD branch, which generates second-harmonic power to offset the second-harmonic component in the load power. Then, based on the spectrum analysis of the APD branch, an APD control strategy consisting of an input power outer loop, an APD branch current inner loop and an output power feedforward loop is developed to achieve fluctuating power decoupling between the input and output, thereby ensuring constant input power and sinusoidal input current. Finally, experimental results validate the efficacy of the proposed topology and control strategy. Though implemented in the MTBBC, the proposed APD technique is extendable to other indirect MC topologies.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 355-366
An Online Estimation Method for DC-Link Capacitor in Doubly Salient Electromagnetic Motor Drive System
As a key component of the motor drive system, the dc-link capacitor has a significant impact on the system reliability. Therefore, it is of great significance to monitor the health status of the capacitor to assist the drive system in achieving preventive maintenance. This article proposes an online estimation method for dc-link capacitor in doubly salient electromagnetic motor (DSEM) drive system with small dc-link capacitance. By utilizing the characteristic that energy flows back from the motor to the bus during the commutation process, causing fluctuations in dc-link capacitor voltage, this method estimates the dc-link capacitance value based on the relationship among the motor phase current, dc-link capacitor voltage, and capacitance value. The proposed method requires no signal injection or the use of additional sensors, does not affect the normal operation of the motor, and offers high-estimation accuracy. The experimental results verify the effectiveness and practicality of the proposed dc-link capacitor estimation method.
- 24 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (1) , 355-366
An Online Estimation Method for DC-Link Capacitor in Doubly Salient Electromagnetic Motor Drive System
As a key component of the motor drive system, the dc-link capacitor has a significant impact on the system reliability. Therefore, it is of great significance to monitor the health status of the capacitor to assist the drive system in achieving preventive maintenance. This article proposes an online estimation method for dc-link capacitor in doubly salient electromagnetic motor (DSEM) drive system with small dc-link capacitance. By utilizing the characteristic that energy flows back from the motor to the bus during the commutation process, causing fluctuations in dc-link capacitor voltage, this method estimates the dc-link capacitance value based on the relationship among the motor phase current, dc-link capacitor voltage, and capacitance value. The proposed method requires no signal injection or the use of additional sensors, does not affect the normal operation of the motor, and offers high-estimation accuracy. The experimental results verify the effectiveness and practicality of the proposed dc-link capacitor estimation method.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6604-6614
Improved Three-Level Third-Harmonic Current Injection Active Filter Circuit for the Three-Phase Diode Rectifier in Aircraft
Three-phase uncontrolled rectifiers have been widely adopted due to the characteristics of robustness and high efficiency, but have the disadvantage of harmonic pollution. Third-harmonic current injection (3rd-HCI) active filter circuit could remove the harmonics. However, new problems occur and lead to current distortions again when the ac line frequency increases, especially in the more electric aircraft applications where the ac line frequency is 360–800 Hz. In this article, the mechanism of current distortions at higher ac line frequency is discussed first. The inductor in the 3rd-HCI active filter circuit is volt-second imbalance. As the ac line frequency increases, the imbalance degree is more severe and then causes current distortions. Therefore, the inductance must be reduced, resulting in larger current ripple and more high-frequency components in the ac line current. Further, based on flying capacitor three-level topology, this article proposed an improved 3rd-HCI active filter circuit and the corresponding control strategy, which not only reduces the current ripple significantly but also mitigates the ac line current distortions. Besides, the input filter capacitive current compensation is also considered to improve the power factor at light load. Finally, all the analysis are verified by experimental results on a 115 Vrms/360–800 Hz/5 kW prototype.
- 12 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (7) , 6604-6614
Improved Three-Level Third-Harmonic Current Injection Active Filter Circuit for the Three-Phase Diode Rectifier in Aircraft
Three-phase uncontrolled rectifiers have been widely adopted due to the characteristics of robustness and high efficiency, but have the disadvantage of harmonic pollution. Third-harmonic current injection (3rd-HCI) active filter circuit could remove the harmonics. However, new problems occur and lead to current distortions again when the ac line frequency increases, especially in the more electric aircraft applications where the ac line frequency is 360–800 Hz. In this article, the mechanism of current distortions at higher ac line frequency is discussed first. The inductor in the 3rd-HCI active filter circuit is volt-second imbalance. As the ac line frequency increases, the imbalance degree is more severe and then causes current distortions. Therefore, the inductance must be reduced, resulting in larger current ripple and more high-frequency components in the ac line current. Further, based on flying capacitor three-level topology, this article proposed an improved 3rd-HCI active filter circuit and the corresponding control strategy, which not only reduces the current ripple significantly but also mitigates the ac line current distortions. Besides, the input filter capacitive current compensation is also considered to improve the power factor at light load. Finally, all the analysis are verified by experimental results on a 115 Vrms/360–800 Hz/5 kW prototype.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4324-4334
A Novel Doubly Salient Electromagnetic Motor Drive System With Small Bus Capacitor
This article proposes a small capacitor drive system for doubly salient electromagnetic motor (DSEM), including the drive circuit and its corresponding control strategy. By taking advantage of the characteristic that the inductor current cannot change abruptly, the system further utilizes AC source to charge the bus capacitor, thereby increasing the maximum voltage of the bus capacitor. Additionally, a bus switch control strategy suitable for this circuit is proposed to reduce the discharge time and energy required by the bus capacitor, thus reducing the required bus capacitance of the system. Compared to the traditional motor drive systems, the proposed system allows for the use of film capacitors instead of electrolytic capacitors, resulting in a reduced system volume and improved reliability and power density. Moreover, compared to the existing researches, the proposed system can more fully utilize the AC source to charge the bus capacitor, thereby improving the efficiency of the AC source, and simultaneously enhancing the power quality of the AC source. The experiments on a 12/8-pole DSEM validate the correctness and feasibility of the proposed system.
- 19 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (3) , 4324-4334
A Novel Doubly Salient Electromagnetic Motor Drive System With Small Bus Capacitor
This article proposes a small capacitor drive system for doubly salient electromagnetic motor (DSEM), including the drive circuit and its corresponding control strategy. By taking advantage of the characteristic that the inductor current cannot change abruptly, the system further utilizes AC source to charge the bus capacitor, thereby increasing the maximum voltage of the bus capacitor. Additionally, a bus switch control strategy suitable for this circuit is proposed to reduce the discharge time and energy required by the bus capacitor, thus reducing the required bus capacitance of the system. Compared to the traditional motor drive systems, the proposed system allows for the use of film capacitors instead of electrolytic capacitors, resulting in a reduced system volume and improved reliability and power density. Moreover, compared to the existing researches, the proposed system can more fully utilize the AC source to charge the bus capacitor, thereby improving the efficiency of the AC source, and simultaneously enhancing the power quality of the AC source. The experiments on a 12/8-pole DSEM validate the correctness and feasibility of the proposed system.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5764-5775
Analysis and Design of Third-Harmonic Current Injection Active Filter Circuit for the Aircraft
Third-harmonic current injection (3rd-HCI) active filter circuit could be utilized to eliminate low frequency harmonics generated by the three-phase uncontrolled rectifier. However, some problems exist when the circuit operates in the 115Vrms/400Hz aircraft power system. The inductor in the 3rd-HCI active filter circuit is not strictly volt-second balance in one switching period, resulting in injection current error and AC line current distortions. The problem is more severe in the 400Hz power system since the imbalance degree increases with a higher AC frequency. Moreover, the common method to mitigate the AC line current distortions is using a smaller inductor, which will increase the inductor current ripple and high frequency harmonic components. This paper investigates the distortion mechanisms and reveals the relationship between current distortion and volt-second imbalance, and the maximum allowed inductance is determined under every operating point. Then, an improved circuit based on ripple current cancellation technique is proposed to realize quasi-zero ripple in the inductor current and to reduce the high frequency harmonics in the AC line currents, which extends the operating range of the circuit significantly. Finally, the correctness of analysis and validity of proposed circuit are verified by experimental results based on a 115Vrms/400Hz/5kW prototype.
- 15 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (5) , 5764-5775
Analysis and Design of Third-Harmonic Current Injection Active Filter Circuit for the Aircraft
Third-harmonic current injection (3rd-HCI) active filter circuit could be utilized to eliminate low frequency harmonics generated by the three-phase uncontrolled rectifier. However, some problems exist when the circuit operates in the 115Vrms/400Hz aircraft power system. The inductor in the 3rd-HCI active filter circuit is not strictly volt-second balance in one switching period, resulting in injection current error and AC line current distortions. The problem is more severe in the 400Hz power system since the imbalance degree increases with a higher AC frequency. Moreover, the common method to mitigate the AC line current distortions is using a smaller inductor, which will increase the inductor current ripple and high frequency harmonic components. This paper investigates the distortion mechanisms and reveals the relationship between current distortion and volt-second imbalance, and the maximum allowed inductance is determined under every operating point. Then, an improved circuit based on ripple current cancellation technique is proposed to realize quasi-zero ripple in the inductor current and to reduce the high frequency harmonics in the AC line currents, which extends the operating range of the circuit significantly. Finally, the correctness of analysis and validity of proposed circuit are verified by experimental results based on a 115Vrms/400Hz/5kW prototype.