Daniele Moreira Cavalcante
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Daniele Moreira Cavalcante has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Diogo Moreira Rodrigues
Department of Periodontology, National Institute of Dental Sciences, Niterói, Brazil
1 shared publication- Diogo da Silva Oliveira
Fluminense Federal University, Brazil
1 shared publication - Edson Jorge Lima Moreira
Universidade Federal Fluminense, Brazil
1 shared publication - Eliane Porto Barboza
Department of Periodontology, Federal Fluminense University School of Dentistry, Niterói, Brazil
1 shared publication - Emmanuel João Nogueira Leal Silva
Department of Endodontics, School of Dentistry, Grande Rio University (UNIGRANRIO), Rio de Janeiro 21210-623, Brazil
1 shared publication - Gustavo De-Deus
Universidade Federal Fluminense, Brazil
1 shared publication
Latest Publications
- 10 May 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 122, 104160
Relationship between smile type and periodontal phenotype: A clinical and tomographic cross-sectional study
- 10 May 2022
- Published by Elsevier in Journal of Dentistry
- Vol. 122, 104160
Relationship between smile type and periodontal phenotype: A clinical and tomographic cross-sectional study
- Open Access
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 35, e021
Effects of clinical use of NiTi reciprocating instruments on cyclic and torsional resistance, and on roughness
Abstrac The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey’s test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.
- 1 January 2021
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 35, e021
Open AccessEffects of clinical use of NiTi reciprocating instruments on cyclic and torsional resistance, and on roughness
Abstrac The aim of the present study was to evaluate the cyclic fatigue, torsional resistance and surface roughness of Reciproc R25 instruments in four different situations, namely as new instruments and as instruments tested after clinical preparation of one, two or three maxillary molars with four root canals. The total time required to perform each root canal preparation was recorded. Cyclic fatigue resistance was determined by the time to fracture using a customized testing device (n = 10 per group). The torsional test evaluated the torque and angle of rotation to failure according to ISO 3630-1 (n = 10 per group). The roughness of the working parts of new and used instruments was evaluated with a profilometer (n = 5 per group). Statistical analysis was performed using one-way ANOVA and Tukey’s test. The level of significance was set at 5%. No fractures or deformations were observed after clinical use. Higher preparation time was needed during the third use of the instruments for all root canals (p < 0.05). There were no significant differences among the groups in regard to either cyclic fatigue or torsional resistance (p > 0.05). Regarding the roughness measurements, groove depth was higher on new and one- versus two- or three-maxillary-molar-prepared instruments (p < 0.05). It can be concluded that the clinical use of Reciproc instruments increased preparation time and decreased surface roughness. However, clinical use did not affect the cyclic fatigue or torsional resistance of the Reciproc instruments.