Ilhamdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ilhamdi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Dony Hidayat
Research Center for Aeronautics Technology, The National Research and Innovation Agency, Bogor 16350, Indonesia , Department of Mechanical Engineering, Faculty of Engineering, Universitas Indonesia, Depok 16424, Indonesia , University of Indonesia image/svg+xml
2 shared publications - A. Zakki
Mechanical Engineering Department of Universitas Andalas, Kampus Limau Manis - Padang, West Sumatera, Indonesia
1 shared publication - Gunawarman Gunawarman
Universitas Andalas
1 shared publication - Irfan Idris
Department of Mechanical Engineering, Engineering Faculty, Universitas Andalas, Padang 25163, Indonesia
1 shared publication - Jon Affi
Department of Mechanical Engineering, Engineering Faculty, Universitas Andalas, Padang 25163, Indonesia
1 shared publication - K. Abdurohaman
Indonesian National Institute of Aeronautics and Space, Bogor, Indonesia 16350
1 shared publication
Latest Publications
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3053 (1)
The effect of post curing on the VARI-ed twill carbon fibre reinforced crestapol 1260 composite
Lightweight aircraft development involves exploration on the strength of inorganic fiber and a lightweight of polymer resin. Their combination could result in a Lightweight aircraft development involves exploration on the strength of inorganic fiber and a lightweight of polymer resin. Their combination could result in a
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3053 (1)
The effect of post curing on the VARI-ed twill carbon fibre reinforced crestapol 1260 composite
Lightweight aircraft development involves exploration on the strength of inorganic fiber and a lightweight of polymer resin. Their combination could result in a Lightweight aircraft development involves exploration on the strength of inorganic fiber and a lightweight of polymer resin. Their combination could result in a
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1)
Hardener composition role on mechanical properties of polyester and lycal resin
Polyester and lycal resin are common used plastic as matrix of composite. Hand lay-up is also easiest and cheap method to produce composite. However this method is still not effective to produces a free porosity composite. Vaccuum infusion in which air is mainly force-sucked out of die then resin introduce on the die, could minimized existence of the porosities. It is effectively used on resin with gel time of 1 to 1.5 hours, in which both of the resin are fit with. Gel time is a function of hardener amount, and different amount of hardener may results different properties. This study investigated influence of hardener ratio to resin and hardener prior to vacuum infusion, towards tensile and compressive strength of the resin. The ratio between polyester and hardener was 10:0.5, 10:1, and 10:1.5. And the ratio between lycal and hardener was 3:0.5, 3:1, and 3:1.5. Density test showed that increasing of hardener amount had slightly reduced density of both resin. Tensile test was conducted according to ASTM D638, and Compressive test was with ASTM D695. It was revealed that a highest tensile strength of 43 MPa at lycal ratio of 3:1, and 39 MPa at polyester ratio of 3:0.5. Other, it resulted a highest compressive strength of 71 MPa at lycal ratio of 3:1.5, of 48 MPa at polyester ratio of 10:1. The lycal ratio of 3:1 provided compressive strength of 68 MPa, a comparable strength with the highest. These information might usefull to prepare technical composition of resin and hardener, to optimize the reinforced plastic composite.
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1)
Open AccessHardener composition role on mechanical properties of polyester and lycal resin
Polyester and lycal resin are common used plastic as matrix of composite. Hand lay-up is also easiest and cheap method to produce composite. However this method is still not effective to produces a free porosity composite. Vaccuum infusion in which air is mainly force-sucked out of die then resin introduce on the die, could minimized existence of the porosities. It is effectively used on resin with gel time of 1 to 1.5 hours, in which both of the resin are fit with. Gel time is a function of hardener amount, and different amount of hardener may results different properties. This study investigated influence of hardener ratio to resin and hardener prior to vacuum infusion, towards tensile and compressive strength of the resin. The ratio between polyester and hardener was 10:0.5, 10:1, and 10:1.5. And the ratio between lycal and hardener was 3:0.5, 3:1, and 3:1.5. Density test showed that increasing of hardener amount had slightly reduced density of both resin. Tensile test was conducted according to ASTM D638, and Compressive test was with ASTM D695. It was revealed that a highest tensile strength of 43 MPa at lycal ratio of 3:1, and 39 MPa at polyester ratio of 3:0.5. Other, it resulted a highest compressive strength of 71 MPa at lycal ratio of 3:1.5, of 48 MPa at polyester ratio of 10:1. The lycal ratio of 3:1 provided compressive strength of 68 MPa, a comparable strength with the highest. These information might usefull to prepare technical composition of resin and hardener, to optimize the reinforced plastic composite.
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 030012
Contribution of hydroxyapatite layer on corrosion and bioactivity properties of Ti-12Cr in simulated body fluid
Biomaterial implant is a material use for biomedical applications such as for fixing bone fractures. One of materials used in this application is titanium and i
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2592 (1) , 030012
Open AccessContribution of hydroxyapatite layer on corrosion and bioactivity properties of Ti-12Cr in simulated body fluid
Biomaterial implant is a material use for biomedical applications such as for fixing bone fractures. One of materials used in this application is titanium and i