DKDieudonné Kaoga Kidmo

Dieudonné Kaoga Kidmo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Dieudonné Kaoga Kidmo has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Bachirou Bogno

    Affiliations Faculty of Science, University of Garoua, Cameroon, Garoua, Cameroon, Laboratoire Matériaux Optiques, Photonique et Systèmes (LMOPS), Université de Lorraine & CentraleSupélec, Metz, France

    6 shared publications
  • Bello Pierre Ngoussandou

    National Advanced School of Engineering of Maroua, University of Maroua, P.O. Box 46 Maroua, Cameroon

    4 shared publications
  • Danwe Raidandi

    National Advanced School of Engineering of Maroua, University of Maroua, P.O. Box 46 Maroua, Cameroon

    4 shared publications
  • Kodji Deli

    Department of Renewable Energy, National Advanced School of Engineering of Maroua, University of Maroua, P.O. Box 46 Maroua, Cameroon

    4 shared publications
  • Michel Aillerie

    Affiliation Laboratoire Matériaux Optiques, Photonique et Systèmes (LMOPS), Université de Lorraine & CentraleSupélec, Metz, France

    4 shared publications
  • Noël Djongyang

    Department of Renewable Energy, The Higher Institute of the Sahel, HIS University of Maroua, PO Box 46, Maroua, Cameroon

    4 shared publications

Latest Publications

  • Open Access

    Evaluation of Wind Power Potential in Lom and Djerem: The Case of the City of Bertoua in East Cameroon Region

    by Doka Baza Gilbert, Jean Benjamin Bidias, Armel Duvalier Pene, Soumeiya Halimatou, Bang Titti Paul Roland, Kitmo, Dieudonné Kidmo Kaoga, Nsouandélé Jean Luc

    The main sources of energy production in Cameroon remain hydropower and thermal power plants using fuel and gas. However, in recent years, it has been experiencing an imbalance that creates a mismatch between production and consumption. It is therefore of great importance to explore new sources of energy such as wind energy. In an effort to seek other sources of energy, we conducted this study aimed at assessing the wind potential in the Lom and Djèrem Department in the city of Bertoua. To achieve this, data obtained from the Bertoua airport were processed using the Weibull distribution, the wind distribution density and express the statistical estimation of wind energy potential at different altitudes of the site (annual energy density average of 60.97 kWh/m²/year), which will facilitate the installation of a wind farm in this locality. Given the existing wind energy potential, its use for the development of electric energy in the region seems somewhat suitable. An advantageous solution for Cameroon in general and the East region is the recovery and transformation of wind energy into electric energy, with a YDF-1500-87 CNYD type wind turbine guaranteeing a production of 82.66 kW at 100 m altitude in the month of January. Next, we determined the wind direction to position the wind turbines at the site. Finally, an assessment of the prediction of the electrical energy produced is made while relying on the careful selection of wind turbines and their load factors.

  • Retracted
    Open Access

    RETRACTED: Enhancing the power quality in radial electrical systems using optimal sizing and selective allocation of distributed generations

    by Bachirou Bogno, Deli Goron, Nisso Nicodem, S. Shanmugan, Dieudonné Kidmo Kaoga, Kitmo, Akhlaque Ahmad Khan, Yasser Fouad, Michel Aillerie

    Optimizing energy resources is a major priority these days. Increasing household energy demand often leads to the deterioration of poorly sized distribution networks. This paper presents a method for energy compensation and optimization in radial distribution systems (ORDS). By integrating distributed generations (DG), an approach is used to evaluate voltage and power profiles, as well as power losses on radial distributed systems (PLRDSs). After integrating distributed generations, improved voltage and power profiles are established. A potential solution to power compensation and blackouts (PCB) can also be the use of hybrid distributed generation systems (HDGSs) that reinforce radial distribution networks (RDNs) by improving power quality. Accordingly, a proposed configuration system is shown in this work to inject multiple renewable energy sources (MRES) from selected regulated nodes. The feasibility of the proposed system is evaluated using particle swarm optimization (PSO), which was used to locate stable nodes and locations, sensitive to voltage fluctuations. The proposed approach is based on the evaluation of the power losses and voltage profiles of the IEEE 33 bus and IEEE 69 bus standards This MATLAB-based method establishes an objective function that converges more quickly to the optimal results.


  • Open Access

    Performance Comparison of Empirical Models for Estimating Global Solar Irradiation in the Soudano-Sahelian Zone of Cameroon: The Case of the City of Maroua and Garoua

    by Kodji Deli, Etienne Houdji, Albert Ayang, Dieudonne Kaoga, Noel Djongyang

    The main objective of this study is to compare thirty-five (35) solar radiation models available in the open literature in order to predict monthly solar radiation in two main cities of Cameroon. This estimation and comparison are based on selected statistical comparison parameters named, root mean square error (RMSE), mean bias error (MBE), mean percentage error (MPE) and determination coefficient (R 2 ). These different models are implemented using regression analysis tools named Exel and MATLAB. Estimated values were compared with measured values according to normalized values of statistical parameters, using measured meteorological data of more than 19 years, from 1984 to 2015. All the models have been classified with their associated ranking according to their statistical parameter accuracy. From this study it appears that the models of Ertekin and Yaldiz (MOD20), Togrul and Onat (MOD28), are more accurate than other models. Indeed, for the city of Maroua (MBE%=-2.82E-14; RMSE%=0.862; MPE=-0.00845; R 2 =0.985), while for Garoua (MBE%=-9.21E-15; RMSE%=0.806; MPE=-0.00631; R 2 =0.959). according to their accuracy these models can be therefore be used to predict monthly solar radiation for soudano-sahelian regions of Cameroon. Correlation equations found in this paper will help solar energy researcher to estimate data with trust because of its fine agreement with the observed one. hence the models presented in this study could be used to evaluate accurately the solar radiation at any locations with similar climate.


  • Open Access

    Statistical analysis of wind speed distribution based on sixWeibull Methods for wind power evaluation in Garoua, Cameroon

    by Dieudonné Kidmo Kaoga, Raidandi Danwe, Serge Yamigno Doka, Noël Djongyang

    Wind data analysis and accurate wind energy potential assessment are critical factors for suitable development of wind power application at a given location. This paper explores wind speed distribution to select the two-parameter Weibull methods that provide accurate and efficient estimation of energy output for Wind Energy Conversion Systems (WECS).The dimensionless shape parameter k and the scale parameter C are determined based on measured hourly mean wind speed data in times-series from 2007 to 2012, collected at the Garoua International Airport, main meteorological station, in Garoua, Cameroon. Six numerical methods, namely Empirical Method (EM), Energy Pattern Factor method (EPF), Graphical Method (GM), Maximum Likelihood Method (MLM), Moment Method (MM) and Modified Maximum Likelihood Method (MMLM) are examined to estimate the Weibull parameters. To analyze the efficiency of the methods and to ascertain how closely the measured data follow the Weibull methods, goodness of fit tests were performed using the chi-square test (X2), correlation coefficient (R2), root mean square error (RMSE) and Kolmogorov-Smirnov test (KOL). The results revealed that the EPF followed by the MM were the most accurate and efficient methods for determining the value of C and k to approximate wind speed distribution. The statistical tests rejected the GM as an adequate method and revealed as well that the EM, MLM and MMLM ranked respectively third, fourth and fifth. Furthermore, the potential for wind energy development in Garoua is not fitted for generating electricity and a very fruitful result would be achieved if windmills were installed for producing community water supply, livestock watering, and farm irrigation.


  • Open Access

    Performance Analysis of Compression Ignition Engines Using Emulsion Fuel Blended with Aluminium Oxide Nanoparticles

    by A. R. Sivaram, N. Prabhu, R. Praveen Kumar, G. Navaneethakrishnan, R. Palanisamy, Kareem M. AboRas, Mohit Bajaj, Repele Djidimbele, Kidmo Kaoga Dieudonné, V. Leela Vinodhan

    One of the excellent choices for compression ignition engines is emulsions. The current experimental analysis deals with transesterified Pongamia biodiesel. This work gives a substantial track to synthesize and to enhance fuel by including aluminium oxide nanoparticles. Emulsification is used to prepare fuel consisting of 88% of Pongamia biodiesel, 10% water, and 2% surfactants with series chemical emulsification techniques. This is then mixed with the ratio of 50 ppm and 100 ppm by mass with aluminium oxide nanoparticles by employing ultrasonication techniques. This work is carried out on compression ignition engines in different phases using biodiesel, nanoparticles, surfactants, and water. It was inferred from the results that there was a considerable enhancement in performance and decrease in emission when compared with diesel. It is found that the system exhibited 15% improvement in brake thermal efficiency and 45% reduction in oxides of nitrogen. The system exhibited considerable improvement in performance and reduction in emission.


  • Open Access

    Influence of cotton bark and rice ball on thermo-physical characteristics of clay bricks

    by Modjonda Modjonda, Dieudonné Kaoga Kidmo, Mohammadou Sali, Bello Pierre Ngoussandou, Danwe Raidandi

    The aim of this work is to contribute to improving thermal comfort in dwellings in the Sudano-Sahelian zone of Cameroon by reducing the temperature gradient between the interior and the exterior of the dwelling during the overheating period. This requires the perfect mastery of the materials used for the construction of the habitat. Terracotta brick seems to meet these criteria. The present work has made it possible to produce fired bricks with interesting thermomechanical properties.The tests carried out on the clays collected in the district of Tchatibali are carried out in order to manufacture specimens. Cotton hulls and rice husks are incorporated into the clay raw material at 0, 2, 4, 6, 8 and 10% to create pores therein. All samples are cooked at 900 ℃ in the laboratory of the Mission for the Promotion of Local Materials in Garoua.Geotechnical, thermal and mechanical properties are determined to assess their potential for use in habitats. The results show that these clays have a water content of 11.90% and a consistency index of 19.10%. These clays are classified as class A-7-6 sandy clays (2). At 6% adjuvants, the results present a thermal conductivity of 0.4 and 0.45 W/m/°K, respectively for rice husks and cotton hulls, and a compressive strength of 20.50 MPa for cotton bark and 20.75 MPa for rice ball. Consequently, the clays collected in the Tchatibali district can be deemed suitable for the manufacture of terracotta bricks which improve thermal comfort in the home.

  • Open Access

    Wind energy potential mapping of the far-north region of Cameroon

    by Godwe Gormo Vincent, Bachirou Bogno, Dieudonné Kaoga Kidmo, Bello Pierre Ngoussandou, Danwe Raidandi, Michel Aillerie

    Globally, wind energy has become one of the least-cost power sources. The Far North Region of Cameroon is credited with exploitable potential in terms of wind energy. However, the step towards harnessing the power of the wind has not yet been reached. The lack of reliable wind energy resource is additionally hindered by its inaccuracy, which makes the development of reliable and accurate wind atlas a very challenging task. This paper aims at developing the wind atlas of the Far North Region of Cameroon by providing location wind characteristics. Ten-year (2011-2020) wind data has been analyzed to obtain wind including wind speeds frequency, direction, power density, energy distributions and wind resource topographic maps. The Golden surfer software modeled 2D and 3D maps, while Global mapper software established topographical maps. These maps allowed selecting higher wind resource areas in which a hypothetical wind farm consisting of 100kW wind turbines was considered. Weibull density function has been considered to determine the wind power density and energy of the region. Economic evaluation and analysis of different wind turbines are presented in this paper.

  • Open Access

    Nonlinear neuro-adaptive MPPT controller and voltage stabilization of PV Systems under real environmental conditions

    by Jean de Dieu Nguimfack-Ndongmo, Bello Pierre Ngoussandou, Deli Goron, Derek Ajesam Asoh, Dieudonné Kaoga Kidmo, Eustace Mbaka Nfah, Godpromesse Kenné


  • Open Access

    An Optimized Synergetic Nonlinear Controller (OSNC) based maximum power point tracking for a standalone photovoltaic system using a boost converter

    by Awe Taissala, Deli Goron, Nicodem Nisso, Dieudonné Kaoga Kidmo, Paul-Salomon Ngohe Ekam, Fabrice Kwefeu Mbakop, Noël Djongyang


  • Open Access

    Hydropower generation potential and prospective scenarios for sustainable electricity supply for the period 2022–2042: A case study of the NIN zone of Cameroon

    by Dieudonné Kaoga Kidmo, Bachirou Bogno, Paul-Salomon Ngohe Ekam, Nicodem Nisso, Michel Aillerie