HWHaoran Wang

Haoran Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Haoran Wang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:

  • Hongyan Fu

    Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College) Xiamen University Xiamen China

    6 shared publications
  • Tongtong Xie

    Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China

    4 shared publications
  • Shiwei Liu

    Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China

    3 shared publications
  • Hao Chen

    Hangzhou Institute of advanced studies, Zhejiang Normal University, Hangzhou, China

    2 shared publications
  • Jian Luo

    2 shared publications
  • Jing Zhou

    Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China

    2 shared publications

Latest Publications

  • Machine learning based all-polarization maintaining single longitudinal mode tunable fiber laser

    by Jian Luo, Wenxun Li, Danqing Liu, Haoran Wang, Zelong Huang, Qisen Yang, Jie Xu, Changlei Guo, Zhengqian Luo

  • High-Sensitivity Micro-Newton Force Sensor With Neural Network-Assisted Demodulation of Multimode Fiber Interferometer

    by Shiwei Liu, Xiaoqian Wang, Shuaihua Gao, Wenzhao Liu, Weiyu Dai, Tongtong Xie, Haoran Wang, Shichen Zheng, Hongyan Fu

    Accurate measurement of small forces is essential in fields such as micro-robots, nanotechnology, and biological cells. This paper introduces a high-sensitive optical fiber sensor for micro-newton forces measurement utilizing neural network-assisted demodulation. This sensor employs a singlemode-multimode-singlemode (SMS) multimodal interference structure, in which a vulcanized silicone rubber film is embedded to achieve the force measurements. This design enables mechanical sensing at the micro-newton level. In traditional interference dip wavelength tracking methods, measurement results often exhibit nonlinear fitting, which increases the system demodulation complexity. Therefore, to enhance measurement accuracy, we introduced a Long Short-Term Memory (LSTM) algorithm combined with a Bayesian optimized LSTM algorithm for data processing. This approach effectively captures the sensor’s response characteristics under different external forces and significantly improves fitting accuracy. After optimization, our sensor achieved a measurement accuracy of 0.99982, with errors reduced to 23.87 μN. The manufacturing process of this sensor is simple and compact, providing essential technical support for the advancement of biomedicine and nanotechnology.

  • Numerical Analysis of Multi-Layer Grating Assisted SPR-Based D-Shaped Optical Fiber

    by Linhang Yang, Haoran Wang, Haoyuan Cai, Longqin Chen, Yushan Chen, Xuchu Deng

    A novel D-shaped fiber optic surface plasmon resonance (SPR) refractive index (RI) sensor with a bimetallic superimposed double-layer metal oxide grating structure is proposed. Ag/Au layers are coated with ZnO and Ta2O5 to considerably increase the electric field strength on the grating surface. The finite element method is used to calculate and analyze the influence of structural parameters, including grating period and the number of gratings, on the performance of the D-shaped fiber grating sensor. The parameters are optimized to achieve the maximum sensor sensitivity. The analyte RI detection range is 1.34–1.41, with a maximum sensitivity of 15,600 nm/RIU.


  • High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method

    by Tongtong Xie, Yi Zhuang, Jing Zhou, Shiwei Liu, Haoran Wang, Zuowei Xu, Hao Chen, Hongyan Fu

    In this paper, a high-resolution and measurement range expanded fiber Bragg grating (FBG) sensing system based on a microwave photonic filter (MPF) with period-breaking interrogation method is illustrated and experimentally demonstrated. With the dispersion of the dispersion compensating fiber (DCF) in the system, the wavelength shift of the FBG in the optical domain can be converted into the notch frequency shift of MPF in the microwave domain, thus realizing high-resolution FBG sensing. Still, the measurement range is limited due to the periodicity of MPF. An optical filter (OF) is inserted into the link that translates the wavelength shift of FBG into the relative amplitude change (RAC) of the MPF. Combined with the frequency shift and RAC of the MPF, this approach can break the periodicity of traditional interrogation methods, overcoming the limitation of measurement range while ensuring high precision. Taking strain sensing as an example, the experimental results show that the sensitivities of the FBG sensing system obtained at the frequencies of 0.9 GHz, 1.9 GHz, and 2.9 GHz are -8.19 kHz/μϵ, -26.57 kHz/μϵ, and -41.52 kHz/μϵ, respectively, and extended measurement ranges are by 1.51 times, 2.96 times, and 4.49 times, respectively. Furthermore, our proposed method, with its simple structure and unique advantages, can achieve adjustable sensitivity and an unrestricted measurement range.


  • Temperature-Compensated Highly Sensitive Reflective SPR Fiber Sensor Based on Tapered Seven-Core Fiber

    by Mengyuan Wu, Jing Zhou, Haoran Wang, Shichen Zheng, Tongtong Xie, Hongyan Fu, Nan Chen, Yikun Bu

    Temperature interference is often inevitable for fiber optic sensors in various practical applications. In this article, a reflective surface plasmon resonance (SPR) sensor based on a tapered multimode fiber (MMF) and seven-core fiber (SCF) structure is proposed for simultaneous measurement of RI and temperature. Along the SCF, polydimethylsiloxane (PDMS) film is applied to the Au-coated surface near the Ag-reflector to achieve the simultaneous measurement function and protect the silver film. To get a better sensing performance, the waist diameter is optimized by simulation and experiment. In the experiment, the maximum sensitivities of RI and temperature of the proposed sensor reach 2078 nm/RIU and -2.76 nm/°C, respectively. Furthermore, the reflective dual-parameter SPR sensor allows fewer samples and simplifies the measurement process, which has great potential in environmental monitoring, disease diagnosis, and biochemical sensing.


  • Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers

    by Tongtong Xie, Haoran Wang, Shiwei Liu, Weiyu Dai, Zuowei Xu, Hao Chen, Hongyan Fu

    We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach–Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/°C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/°C to 8.44 MHz/°C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59–16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.


  • Open Access

    Microwave Photonic Filter by Using Recirculating Frequency Shifter to Generate Optical Frequency Comb

    by Weiyu Dai, Weiying Rao, Haoran Wang, Hongyan Fu

    In this paper, a continuously tunable microwave photonic filter (MPF) with optical frequency comb (OFC) generated by recirculating frequency shifter (RFS) based on an inphase/quadrature (I/Q) modulator is proposed and experimentally demonstrated. A chirped fiber Bragg grating (CFBG) is inserted into the RFS loop to act as an optical bandpass filter. The central frequencies of two passbands of the MPF in 20 GHz range have been tuned linearly from 7.67 GHz to 9.04 GHz, and 15.34 GHz to 18.03 GHz, respectively by changing the frequency of the driving microwave signal onto the I/Q modulator from 20 GHz to 17 GHz. When the frequency of the driving microwave signal is decreased, OFC with smaller tone spacing is generated, and then the MPF's passbands move to higher frequency. So that, the proposed MPF's passbands with high frequencies can be achieved by applying driving microwave signal with low frequency to generate the OFC. By varying the bandwidth of the CFBG, the number of comb lines can be changed, which results in different bandwidth of the MPF's passband. Furthermore, in our experiment by carefully adjusting bias voltage of the Mach-Zenhder modulator, when the frequencies of driving microwave signal onto the I/Q modulator is 20 GHz and 18 GHz, one passband in the 20 GHz range can be suppressed at the frequency of 15.34 GHz, and 8.52 GHz, respectively.


  • Open Access

    A Dual-Channel Surface Plasmon Resonance Sensor Based on Dual-Polarized Photonic Crystal Fiber for Ultra-Wide Range and High Sensitivity of Refractive Index Detection

    by Haoran Wang, Weiying Rao, Jian Luo, Hongyan Fu

    A surface plasmon resonance sensor based on a dual-groove photonic crystal fiber (PCF) for refractive index (RI) sensing with ultra-wide measurement range and high sensitivity is designed and theoretically investigated. The upper and right grooves of the PCF as different sensing channels are coated with Au or Au-TiO2 compound film. The influence of the parameters on the sensing performance of the designed sensor are analyzed. Numerical results show that the maximum wavelength sensitivity (WS) of 6800 nm/RIU with a wavelength resolution of 1.47 × 10 -5 RIU and maximum amplitude sensitivity (AS) of 5440 RIU -1 for the x polarization in the ultra-wide measurement range from 1.25 to 1.43 have been achieved. For y polarization, the proposed sensor has a maximum WS of 13200 nm/RIU and AS of 3465 RIU -1 in the detection range from 1.39 to 1.43. The corresponding wavelength resolution is obtained about 7.58 × 10 -6 RIU. Moreover, the ultra-wide range and high sensitivity of the sensor can be flexibly adjusted by a polarization controller to meet different practical requirements. Therefore, the proposed sensor would be a suitable candidate for medical testing, bio-sensing and environmental monitoring.