Haoran Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Haoran Wang has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Hongyan Fu
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College) Xiamen University Xiamen China
6 shared publications - Tongtong Xie
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
4 shared publications - Shiwei Liu
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
3 shared publications - Hao Chen
Hangzhou Institute of advanced studies, Zhejiang Normal University, Hangzhou, China
2 shared publications Jian Luo
2 shared publications- Jing Zhou
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
2 shared publications
Latest Publications
- 12 August 2026
- Published by Elsevier in Infrared Physics & Technology
- Vol. 158
Machine learning based all-polarization maintaining single longitudinal mode tunable fiber laser
- 12 August 2026
- Published by Elsevier in Infrared Physics & Technology
- Vol. 158
Machine learning based all-polarization maintaining single longitudinal mode tunable fiber laser
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 24135-24143
High Circular Dichroism Chiral Metasurface for Mid-Infrared Molecular Fingerprint Sensing via Hybrid Fano-Phonon Resonances
- 1 August 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 24135-24143
High Circular Dichroism Chiral Metasurface for Mid-Infrared Molecular Fingerprint Sensing via Hybrid Fano-Phonon Resonances
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
High-Sensitivity Micro-Newton Force Sensor With Neural Network-Assisted Demodulation of Multimode Fiber Interferometer
Accurate measurement of small forces is essential in fields such as micro-robots, nanotechnology, and biological cells. This paper introduces a high-sensitive optical fiber sensor for micro-newton forces measurement utilizing neural network-assisted demodulation. This sensor employs a singlemode-multimode-singlemode (SMS) multimodal interference structure, in which a vulcanized silicone rubber film is embedded to achieve the force measurements. This design enables mechanical sensing at the micro-newton level. In traditional interference dip wavelength tracking methods, measurement results often exhibit nonlinear fitting, which increases the system demodulation complexity. Therefore, to enhance measurement accuracy, we introduced a Long Short-Term Memory (LSTM) algorithm combined with a Bayesian optimized LSTM algorithm for data processing. This approach effectively captures the sensor’s response characteristics under different external forces and significantly improves fitting accuracy. After optimization, our sensor achieved a measurement accuracy of 0.99982, with errors reduced to 23.87 μN. The manufacturing process of this sensor is simple and compact, providing essential technical support for the advancement of biomedicine and nanotechnology.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
High-Sensitivity Micro-Newton Force Sensor With Neural Network-Assisted Demodulation of Multimode Fiber Interferometer
Accurate measurement of small forces is essential in fields such as micro-robots, nanotechnology, and biological cells. This paper introduces a high-sensitive optical fiber sensor for micro-newton forces measurement utilizing neural network-assisted demodulation. This sensor employs a singlemode-multimode-singlemode (SMS) multimodal interference structure, in which a vulcanized silicone rubber film is embedded to achieve the force measurements. This design enables mechanical sensing at the micro-newton level. In traditional interference dip wavelength tracking methods, measurement results often exhibit nonlinear fitting, which increases the system demodulation complexity. Therefore, to enhance measurement accuracy, we introduced a Long Short-Term Memory (LSTM) algorithm combined with a Bayesian optimized LSTM algorithm for data processing. This approach effectively captures the sensor’s response characteristics under different external forces and significantly improves fitting accuracy. After optimization, our sensor achieved a measurement accuracy of 0.99982, with errors reduced to 23.87 μN. The manufacturing process of this sensor is simple and compact, providing essential technical support for the advancement of biomedicine and nanotechnology.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (22) , 1305-1308
Numerical Analysis of Multi-Layer Grating Assisted SPR-Based D-Shaped Optical Fiber
A novel D-shaped fiber optic surface plasmon resonance (SPR) refractive index (RI) sensor with a bimetallic superimposed double-layer metal oxide grating structure is proposed. Ag/Au layers are coated with ZnO and Ta2O5 to considerably increase the electric field strength on the grating surface. The finite element method is used to calculate and analyze the influence of structural parameters, including grating period and the number of gratings, on the performance of the D-shaped fiber grating sensor. The parameters are optimized to achieve the maximum sensor sensitivity. The analyte RI detection range is 1.34–1.41, with a maximum sensitivity of 15,600 nm/RIU.
- 7 August 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (22) , 1305-1308
Numerical Analysis of Multi-Layer Grating Assisted SPR-Based D-Shaped Optical Fiber
A novel D-shaped fiber optic surface plasmon resonance (SPR) refractive index (RI) sensor with a bimetallic superimposed double-layer metal oxide grating structure is proposed. Ag/Au layers are coated with ZnO and Ta2O5 to considerably increase the electric field strength on the grating surface. The finite element method is used to calculate and analyze the influence of structural parameters, including grating period and the number of gratings, on the performance of the D-shaped fiber grating sensor. The parameters are optimized to achieve the maximum sensor sensitivity. The analyte RI detection range is 1.34–1.41, with a maximum sensitivity of 15,600 nm/RIU.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (21) , 7717-7724
High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method
In this paper, a high-resolution and measurement range expanded fiber Bragg grating (FBG) sensing system based on a microwave photonic filter (MPF) with period-breaking interrogation method is illustrated and experimentally demonstrated. With the dispersion of the dispersion compensating fiber (DCF) in the system, the wavelength shift of the FBG in the optical domain can be converted into the notch frequency shift of MPF in the microwave domain, thus realizing high-resolution FBG sensing. Still, the measurement range is limited due to the periodicity of MPF. An optical filter (OF) is inserted into the link that translates the wavelength shift of FBG into the relative amplitude change (RAC) of the MPF. Combined with the frequency shift and RAC of the MPF, this approach can break the periodicity of traditional interrogation methods, overcoming the limitation of measurement range while ensuring high precision. Taking strain sensing as an example, the experimental results show that the sensitivities of the FBG sensing system obtained at the frequencies of 0.9 GHz, 1.9 GHz, and 2.9 GHz are -8.19 kHz/μϵ, -26.57 kHz/μϵ, and -41.52 kHz/μϵ, respectively, and extended measurement ranges are by 1.51 times, 2.96 times, and 4.49 times, respectively. Furthermore, our proposed method, with its simple structure and unique advantages, can achieve adjustable sensitivity and an unrestricted measurement range.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (21) , 7717-7724
High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method
In this paper, a high-resolution and measurement range expanded fiber Bragg grating (FBG) sensing system based on a microwave photonic filter (MPF) with period-breaking interrogation method is illustrated and experimentally demonstrated. With the dispersion of the dispersion compensating fiber (DCF) in the system, the wavelength shift of the FBG in the optical domain can be converted into the notch frequency shift of MPF in the microwave domain, thus realizing high-resolution FBG sensing. Still, the measurement range is limited due to the periodicity of MPF. An optical filter (OF) is inserted into the link that translates the wavelength shift of FBG into the relative amplitude change (RAC) of the MPF. Combined with the frequency shift and RAC of the MPF, this approach can break the periodicity of traditional interrogation methods, overcoming the limitation of measurement range while ensuring high precision. Taking strain sensing as an example, the experimental results show that the sensitivities of the FBG sensing system obtained at the frequencies of 0.9 GHz, 1.9 GHz, and 2.9 GHz are -8.19 kHz/μϵ, -26.57 kHz/μϵ, and -41.52 kHz/μϵ, respectively, and extended measurement ranges are by 1.51 times, 2.96 times, and 4.49 times, respectively. Furthermore, our proposed method, with its simple structure and unique advantages, can achieve adjustable sensitivity and an unrestricted measurement range.
- 1 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14328-14334
Temperature-Compensated Highly Sensitive Reflective SPR Fiber Sensor Based on Tapered Seven-Core Fiber
Temperature interference is often inevitable for fiber optic sensors in various practical applications. In this article, a reflective surface plasmon resonance (SPR) sensor based on a tapered multimode fiber (MMF) and seven-core fiber (SCF) structure is proposed for simultaneous measurement of RI and temperature. Along the SCF, polydimethylsiloxane (PDMS) film is applied to the Au-coated surface near the Ag-reflector to achieve the simultaneous measurement function and protect the silver film. To get a better sensing performance, the waist diameter is optimized by simulation and experiment. In the experiment, the maximum sensitivities of RI and temperature of the proposed sensor reach 2078 nm/RIU and -2.76 nm/°C, respectively. Furthermore, the reflective dual-parameter SPR sensor allows fewer samples and simplifies the measurement process, which has great potential in environmental monitoring, disease diagnosis, and biochemical sensing.
- 1 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (9) , 14328-14334
Temperature-Compensated Highly Sensitive Reflective SPR Fiber Sensor Based on Tapered Seven-Core Fiber
Temperature interference is often inevitable for fiber optic sensors in various practical applications. In this article, a reflective surface plasmon resonance (SPR) sensor based on a tapered multimode fiber (MMF) and seven-core fiber (SCF) structure is proposed for simultaneous measurement of RI and temperature. Along the SCF, polydimethylsiloxane (PDMS) film is applied to the Au-coated surface near the Ag-reflector to achieve the simultaneous measurement function and protect the silver film. To get a better sensing performance, the waist diameter is optimized by simulation and experiment. In the experiment, the maximum sensitivities of RI and temperature of the proposed sensor reach 2078 nm/RIU and -2.76 nm/°C, respectively. Furthermore, the reflective dual-parameter SPR sensor allows fewer samples and simplifies the measurement process, which has great potential in environmental monitoring, disease diagnosis, and biochemical sensing.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (1) , 477-484
Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach–Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/°C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/°C to 8.44 MHz/°C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59–16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (1) , 477-484
Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach–Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/°C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/°C to 8.44 MHz/°C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59–16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.
- Open Access
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-8
Microwave Photonic Filter by Using Recirculating Frequency Shifter to Generate Optical Frequency Comb
In this paper, a continuously tunable microwave photonic filter (MPF) with optical frequency comb (OFC) generated by recirculating frequency shifter (RFS) based on an inphase/quadrature (I/Q) modulator is proposed and experimentally demonstrated. A chirped fiber Bragg grating (CFBG) is inserted into the RFS loop to act as an optical bandpass filter. The central frequencies of two passbands of the MPF in 20 GHz range have been tuned linearly from 7.67 GHz to 9.04 GHz, and 15.34 GHz to 18.03 GHz, respectively by changing the frequency of the driving microwave signal onto the I/Q modulator from 20 GHz to 17 GHz. When the frequency of the driving microwave signal is decreased, OFC with smaller tone spacing is generated, and then the MPF's passbands move to higher frequency. So that, the proposed MPF's passbands with high frequencies can be achieved by applying driving microwave signal with low frequency to generate the OFC. By varying the bandwidth of the CFBG, the number of comb lines can be changed, which results in different bandwidth of the MPF's passband. Furthermore, in our experiment by carefully adjusting bias voltage of the Mach-Zenhder modulator, when the frequencies of driving microwave signal onto the I/Q modulator is 20 GHz and 18 GHz, one passband in the 20 GHz range can be suppressed at the frequency of 15.34 GHz, and 8.52 GHz, respectively.
- 26 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (2) , 1-8
Open AccessMicrowave Photonic Filter by Using Recirculating Frequency Shifter to Generate Optical Frequency Comb
In this paper, a continuously tunable microwave photonic filter (MPF) with optical frequency comb (OFC) generated by recirculating frequency shifter (RFS) based on an inphase/quadrature (I/Q) modulator is proposed and experimentally demonstrated. A chirped fiber Bragg grating (CFBG) is inserted into the RFS loop to act as an optical bandpass filter. The central frequencies of two passbands of the MPF in 20 GHz range have been tuned linearly from 7.67 GHz to 9.04 GHz, and 15.34 GHz to 18.03 GHz, respectively by changing the frequency of the driving microwave signal onto the I/Q modulator from 20 GHz to 17 GHz. When the frequency of the driving microwave signal is decreased, OFC with smaller tone spacing is generated, and then the MPF's passbands move to higher frequency. So that, the proposed MPF's passbands with high frequencies can be achieved by applying driving microwave signal with low frequency to generate the OFC. By varying the bandwidth of the CFBG, the number of comb lines can be changed, which results in different bandwidth of the MPF's passband. Furthermore, in our experiment by carefully adjusting bias voltage of the Mach-Zenhder modulator, when the frequencies of driving microwave signal onto the I/Q modulator is 20 GHz and 18 GHz, one passband in the 20 GHz range can be suppressed at the frequency of 15.34 GHz, and 8.52 GHz, respectively.
- Open Access
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (1) , 1-11
A Dual-Channel Surface Plasmon Resonance Sensor Based on Dual-Polarized Photonic Crystal Fiber for Ultra-Wide Range and High Sensitivity of Refractive Index Detection
A surface plasmon resonance sensor based on a dual-groove photonic crystal fiber (PCF) for refractive index (RI) sensing with ultra-wide measurement range and high sensitivity is designed and theoretically investigated. The upper and right grooves of the PCF as different sensing channels are coated with Au or Au-TiO2 compound film. The influence of the parameters on the sensing performance of the designed sensor are analyzed. Numerical results show that the maximum wavelength sensitivity (WS) of 6800 nm/RIU with a wavelength resolution of 1.47 × 10 -5 RIU and maximum amplitude sensitivity (AS) of 5440 RIU -1 for the x polarization in the ultra-wide measurement range from 1.25 to 1.43 have been achieved. For y polarization, the proposed sensor has a maximum WS of 13200 nm/RIU and AS of 3465 RIU -1 in the detection range from 1.39 to 1.43. The corresponding wavelength resolution is obtained about 7.58 × 10 -6 RIU. Moreover, the ultra-wide range and high sensitivity of the sensor can be flexibly adjusted by a polarization controller to meet different practical requirements. Therefore, the proposed sensor would be a suitable candidate for medical testing, bio-sensing and environmental monitoring.
- 26 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 13 (1) , 1-11
Open AccessA Dual-Channel Surface Plasmon Resonance Sensor Based on Dual-Polarized Photonic Crystal Fiber for Ultra-Wide Range and High Sensitivity of Refractive Index Detection
A surface plasmon resonance sensor based on a dual-groove photonic crystal fiber (PCF) for refractive index (RI) sensing with ultra-wide measurement range and high sensitivity is designed and theoretically investigated. The upper and right grooves of the PCF as different sensing channels are coated with Au or Au-TiO2 compound film. The influence of the parameters on the sensing performance of the designed sensor are analyzed. Numerical results show that the maximum wavelength sensitivity (WS) of 6800 nm/RIU with a wavelength resolution of 1.47 × 10 -5 RIU and maximum amplitude sensitivity (AS) of 5440 RIU -1 for the x polarization in the ultra-wide measurement range from 1.25 to 1.43 have been achieved. For y polarization, the proposed sensor has a maximum WS of 13200 nm/RIU and AS of 3465 RIU -1 in the detection range from 1.39 to 1.43. The corresponding wavelength resolution is obtained about 7.58 × 10 -6 RIU. Moreover, the ultra-wide range and high sensitivity of the sensor can be flexibly adjusted by a polarization controller to meet different practical requirements. Therefore, the proposed sensor would be a suitable candidate for medical testing, bio-sensing and environmental monitoring.