Shiwei Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shiwei Liu has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Hongyan Fu
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College) Xiamen University Xiamen China
10 shared publications - Tongtong Xie
Department of Electronic Engineering, School of Electronic Science and Engineering (National Model Microelectronics College), and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
8 shared publications - Weiyu Dai
Department of Electronic Engineering, School of Electronic Science and Engineering, National Model Microelectronics College, and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
5 shared publications - Hao Chen
Hangzhou Institute of advanced studies, Zhejiang Normal University, Hangzhou, China
3 shared publications - Haoran Wang
Jimei University
3 shared publications - Shuaihua Gao
Department of Electronic Engineering, School of Electronic Science and Engineering, National Model Microelectronics College, and Fujian Key Laboratory of Ultrafast Laser Technology and Applications, Xiamen University, Xiamen, China
3 shared publications
Latest Publications
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
High-Sensitivity Micro-Newton Force Sensor With Neural Network-Assisted Demodulation of Multimode Fiber Interferometer
Accurate measurement of small forces is essential in fields such as micro-robots, nanotechnology, and biological cells. This paper introduces a high-sensitive optical fiber sensor for micro-newton forces measurement utilizing neural network-assisted demodulation. This sensor employs a singlemode-multimode-singlemode (SMS) multimodal interference structure, in which a vulcanized silicone rubber film is embedded to achieve the force measurements. This design enables mechanical sensing at the micro-newton level. In traditional interference dip wavelength tracking methods, measurement results often exhibit nonlinear fitting, which increases the system demodulation complexity. Therefore, to enhance measurement accuracy, we introduced a Long Short-Term Memory (LSTM) algorithm combined with a Bayesian optimized LSTM algorithm for data processing. This approach effectively captures the sensor’s response characteristics under different external forces and significantly improves fitting accuracy. After optimization, our sensor achieved a measurement accuracy of 0.99982, with errors reduced to 23.87 μN. The manufacturing process of this sensor is simple and compact, providing essential technical support for the advancement of biomedicine and nanotechnology.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-8
High-Sensitivity Micro-Newton Force Sensor With Neural Network-Assisted Demodulation of Multimode Fiber Interferometer
Accurate measurement of small forces is essential in fields such as micro-robots, nanotechnology, and biological cells. This paper introduces a high-sensitive optical fiber sensor for micro-newton forces measurement utilizing neural network-assisted demodulation. This sensor employs a singlemode-multimode-singlemode (SMS) multimodal interference structure, in which a vulcanized silicone rubber film is embedded to achieve the force measurements. This design enables mechanical sensing at the micro-newton level. In traditional interference dip wavelength tracking methods, measurement results often exhibit nonlinear fitting, which increases the system demodulation complexity. Therefore, to enhance measurement accuracy, we introduced a Long Short-Term Memory (LSTM) algorithm combined with a Bayesian optimized LSTM algorithm for data processing. This approach effectively captures the sensor’s response characteristics under different external forces and significantly improves fitting accuracy. After optimization, our sensor achieved a measurement accuracy of 0.99982, with errors reduced to 23.87 μN. The manufacturing process of this sensor is simple and compact, providing essential technical support for the advancement of biomedicine and nanotechnology.
- 23 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6855-6862
Tantalum Pentoxide Sensitization Empowers U-Shaped Dual-Channel SPR Fiber Sensor
To address the increasing demand for versatile applications, there is a pressing need for high-resolution sensing devices that can operate in intricate environmental conditions. This work demonstrates a highly sensitive U-shaped surface plasmon resonance (SPR) sensor with two independent sensing channels, based on tantalum pentoxide (Ta2O5) film sensitization technology. We systematically optimized the sensor’s key structural parameters using the transmission matrix method. The experimental findings demonstrate that the refractive index (RI) sensitivity of Channel B reaches up to 4161 nm/RIU, which is twice that of Channel A (2005 nm/RIU). Temperature variations have a significant impact on Channel B (-0.25 nm/°C) due to the Ag/Ta2O5 film coating, while Channel A (just silver film) stays practically unaffected within the measurement range of 15 to 35°C. Furthermore, the U-shaped sensor features high sensitivity, compact structure, and good stability, which establishes a novel platform for dual-channel measurement applications.
- 23 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (5) , 6855-6862
Tantalum Pentoxide Sensitization Empowers U-Shaped Dual-Channel SPR Fiber Sensor
To address the increasing demand for versatile applications, there is a pressing need for high-resolution sensing devices that can operate in intricate environmental conditions. This work demonstrates a highly sensitive U-shaped surface plasmon resonance (SPR) sensor with two independent sensing channels, based on tantalum pentoxide (Ta2O5) film sensitization technology. We systematically optimized the sensor’s key structural parameters using the transmission matrix method. The experimental findings demonstrate that the refractive index (RI) sensitivity of Channel B reaches up to 4161 nm/RIU, which is twice that of Channel A (2005 nm/RIU). Temperature variations have a significant impact on Channel B (-0.25 nm/°C) due to the Ag/Ta2O5 film coating, while Channel A (just silver film) stays practically unaffected within the measurement range of 15 to 35°C. Furthermore, the U-shaped sensor features high sensitivity, compact structure, and good stability, which establishes a novel platform for dual-channel measurement applications.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A High-Resolution Fiber Bragg Grating Liquid Level Sensing System Based on Optical Carrier Microwave Interferometry
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
A High-Resolution Fiber Bragg Grating Liquid Level Sensing System Based on Optical Carrier Microwave Interferometry
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (1) , 950-959
Sensitivity-Enhanced Optical Fiber Interferometric Phase Demodulation Based on Multipassband Microwave Photonic Filter With Frequency Down-Conversion
A phase sensitivity-enhanced demodulation system for optical fiber interferometers based on a multi passband microwave photonic (MWP) filter is proposed and experimentally demonstrated, which effectively breaks the trade-off between detection frequency and phase sensitivity, enabling the simultaneous realization of high sensitivity and low-frequency detection. In the experimental setup, an optical fiber Fabry–Pérot interferometer (FPI) served as the sensing head, and an additional optical fiber FPI was introduced as a reference. The interference between the two FPIs generated both independent passbands and cross-interference passbands of the MPF, the latter enabling frequency down-conversion. The passband associated with the sensing FPI, initially centered at 1.752 GHz, was translated to 0.537 GHz via the interference between the sensing and reference FPIs, effectively mapping the phase modulation to a lower frequency. Consequently, a 3.26-fold enhancement in the detected phase shift was achieved at 0.537 GHz. Moreover, simultaneous phase demodulation from multiple passbands (e.g., 1.752 and 2.202GHz), down-converted to 1.032 and 0.545GHz, respectively, was successfully realized without spectral interference, demonstrating the scalability of the scheme. This system significantly enhances the detection performance of optical fiber interferometers simply and cost-effectively, offering a novel and scalable strategy for the design of high-resolution fiber interferometric sensing systems.
- 24 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 74 (1) , 950-959
Sensitivity-Enhanced Optical Fiber Interferometric Phase Demodulation Based on Multipassband Microwave Photonic Filter With Frequency Down-Conversion
A phase sensitivity-enhanced demodulation system for optical fiber interferometers based on a multi passband microwave photonic (MWP) filter is proposed and experimentally demonstrated, which effectively breaks the trade-off between detection frequency and phase sensitivity, enabling the simultaneous realization of high sensitivity and low-frequency detection. In the experimental setup, an optical fiber Fabry–Pérot interferometer (FPI) served as the sensing head, and an additional optical fiber FPI was introduced as a reference. The interference between the two FPIs generated both independent passbands and cross-interference passbands of the MPF, the latter enabling frequency down-conversion. The passband associated with the sensing FPI, initially centered at 1.752 GHz, was translated to 0.537 GHz via the interference between the sensing and reference FPIs, effectively mapping the phase modulation to a lower frequency. Consequently, a 3.26-fold enhancement in the detected phase shift was achieved at 0.537 GHz. Moreover, simultaneous phase demodulation from multiple passbands (e.g., 1.752 and 2.202GHz), down-converted to 1.032 and 0.545GHz, respectively, was successfully realized without spectral interference, demonstrating the scalability of the scheme. This system significantly enhances the detection performance of optical fiber interferometers simply and cost-effectively, offering a novel and scalable strategy for the design of high-resolution fiber interferometric sensing systems.
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 41345-41353
Silicone-Encapsulated Wearable Fiber-Optic Sensor for Respiratory and Heart Rate Measurement
This paper proposes a silicone-encapsulated wearable fiber-optic sensor based on a single-mode-multimode -few-mode-multimode-single-mode fiber-optic Mach-Zehnder interferometer configuration, achieving simultaneous extraction of respiratory and heartbeat signals through the variational mode decomposition algorithm. The sensing region is fully encapsulated within a soft and elastic silicone layer, improving the durability and maintaining high biocompatibility. The proposed sensor exhibits high curvature sensitivity, achieving an average sensitivity of -17.45 dB/m⁻¹, with a maximum sensitivity of -69.42 dB/m⁻¹ within the curvature range of 2.77-3.92 m⁻¹, and an average of 22.76 dB/m⁻¹ with a maximum of 65.25 dB/m⁻¹ in the extended range of 3.92-4.96 m⁻¹. Experimental results show that the sensor can be freely worn at different positions on the chest, and it successfully acquires both respiratory and heartbeat signals under various breathing patterns. The respiratory and heart rates measured by the system show good agreement with manual breath counting and a commercial heart rate monitor, respectively. With advantages including cost-effective fabrication, simplified manufacturing process, and low temperature cross-sensitivity, this design provides a practical approach for implementing fiber-optic sensors in clinical respiration and heart rate monitoring.
- 2 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (22) , 41345-41353
Silicone-Encapsulated Wearable Fiber-Optic Sensor for Respiratory and Heart Rate Measurement
This paper proposes a silicone-encapsulated wearable fiber-optic sensor based on a single-mode-multimode -few-mode-multimode-single-mode fiber-optic Mach-Zehnder interferometer configuration, achieving simultaneous extraction of respiratory and heartbeat signals through the variational mode decomposition algorithm. The sensing region is fully encapsulated within a soft and elastic silicone layer, improving the durability and maintaining high biocompatibility. The proposed sensor exhibits high curvature sensitivity, achieving an average sensitivity of -17.45 dB/m⁻¹, with a maximum sensitivity of -69.42 dB/m⁻¹ within the curvature range of 2.77-3.92 m⁻¹, and an average of 22.76 dB/m⁻¹ with a maximum of 65.25 dB/m⁻¹ in the extended range of 3.92-4.96 m⁻¹. Experimental results show that the sensor can be freely worn at different positions on the chest, and it successfully acquires both respiratory and heartbeat signals under various breathing patterns. The respiratory and heart rates measured by the system show good agreement with manual breath counting and a commercial heart rate monitor, respectively. With advantages including cost-effective fabrication, simplified manufacturing process, and low temperature cross-sensitivity, this design provides a practical approach for implementing fiber-optic sensors in clinical respiration and heart rate monitoring.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28390-28396
Dual-Parameter Surface Plasmon Resonance Sensor for Simultaneous Detection of Humidity and Temperature Based on Cascaded PVA-GO Composite Film and PDMS Film
A surface plasmon resonance (SPR) sensor based on a polyvinyl alcohol-graphene oxide (PVA-GO) composite film and a polydimethylsiloxane (PDMS) film was proposed for simultaneous measurement of relative humidity (RH) and temperature. The SPR effect was excited by an MMF-SMF-MMF cascaded structure coated with Ag film, and one channel was excited by coating PVA-GO film on its surface for RH sensing, while the other channel excited by coating PDMS film is used for temperature measurement. The experimental results show that the RH sensitivity of the sensor is 0.507 nm/% RH, and the temperature sensitivity is -3.27 nm/°C. The proposed sensor offers the advantages of compact structure, low cost, and stability, and is suitable for fields that require simultaneous measurement of temperature and relative humidity, such as agricultural storage, industrial production, and weather forecasting.
- 20 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28390-28396
Dual-Parameter Surface Plasmon Resonance Sensor for Simultaneous Detection of Humidity and Temperature Based on Cascaded PVA-GO Composite Film and PDMS Film
A surface plasmon resonance (SPR) sensor based on a polyvinyl alcohol-graphene oxide (PVA-GO) composite film and a polydimethylsiloxane (PDMS) film was proposed for simultaneous measurement of relative humidity (RH) and temperature. The SPR effect was excited by an MMF-SMF-MMF cascaded structure coated with Ag film, and one channel was excited by coating PVA-GO film on its surface for RH sensing, while the other channel excited by coating PDMS film is used for temperature measurement. The experimental results show that the RH sensitivity of the sensor is 0.507 nm/% RH, and the temperature sensitivity is -3.27 nm/°C. The proposed sensor offers the advantages of compact structure, low cost, and stability, and is suitable for fields that require simultaneous measurement of temperature and relative humidity, such as agricultural storage, industrial production, and weather forecasting.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19268-19274
Deep Learning Assisted Liquid Level Sensing Based on an MZI by Using Thin-Core Fiber With a Diaphragm
We propose a liquid level sensing scheme utilizing a Mach -Zehnder interferometer (MZI), achieving high accuracy and wide-range measurements through the application of deep learning algorithms. In the scheme, the MZI is constructed by connecting a thin-core fiber (TCF) with a core-offset in the middle of the single-mode fiber (SMF). A cylindrical cavity is fabricated using 3D printing technology, with the MZI optical fiber structure bonded to the diaphragm on the surface of the cavity. Liquid pressure is exerted on the diaphragm, resulting in the deformation of the MZI structure and inducing changes in the optical spectrum. However, traditional spectral dip tracking methods cannot achieve wide-range and high-precision liquid level sensing. By introducing deep learning Long Short-Term Memory (LSTM) and Convolutional Neural Network-Long Short-Term Memory (CNN-LSTM) models to analyze the sensing spectra, we overcome the limitations of measurement range and accuracy of the liquid level measurements, extending the measurement range to 450 mm, achieving a coefficient of determination of 0.99986, and reducing the error within 2 mm. The proposed analysis method has been successfully applied in the liquid level sensing field, demonstrating the great potential of deep learning algorithms in signal demodulation.
- 15 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (11) , 19268-19274
Deep Learning Assisted Liquid Level Sensing Based on an MZI by Using Thin-Core Fiber With a Diaphragm
We propose a liquid level sensing scheme utilizing a Mach -Zehnder interferometer (MZI), achieving high accuracy and wide-range measurements through the application of deep learning algorithms. In the scheme, the MZI is constructed by connecting a thin-core fiber (TCF) with a core-offset in the middle of the single-mode fiber (SMF). A cylindrical cavity is fabricated using 3D printing technology, with the MZI optical fiber structure bonded to the diaphragm on the surface of the cavity. Liquid pressure is exerted on the diaphragm, resulting in the deformation of the MZI structure and inducing changes in the optical spectrum. However, traditional spectral dip tracking methods cannot achieve wide-range and high-precision liquid level sensing. By introducing deep learning Long Short-Term Memory (LSTM) and Convolutional Neural Network-Long Short-Term Memory (CNN-LSTM) models to analyze the sensing spectra, we overcome the limitations of measurement range and accuracy of the liquid level measurements, extending the measurement range to 450 mm, achieving a coefficient of determination of 0.99986, and reducing the error within 2 mm. The proposed analysis method has been successfully applied in the liquid level sensing field, demonstrating the great potential of deep learning algorithms in signal demodulation.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (3) , 149-152
Shortwave Infrared Electro-Optic Frequency Combs Generation Based on Wideband Parametric Conversion
An all-fiber short-wave infrared electro-optic frequency combs (SWIR E-O combs) based on parametric amplification is proposed and experimentally demonstrated by converting the near-infrared combs into the shortwave infrared region. The SWIR E-O combs shows tunable central wavelength and spectral line spacing. Based on the simple combination of the fiber optical parametric amplifier and the Thulium-doped fiber amplifier directly pumped by C-band E-O combs, the power of SWIR E-O combs has been effectively enhanced. In addition, a section of single-mode fiber is used for pulse compression of the C-band E-O combs, and the 10 dB spectral width of the SWIR E-O combs is 17.81nm. The proposed SWIR combs with repetition rates of tens of GHz is of high interest for coherent communication and gas sensing in the SWIR region.
- 19 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Technology Letters
- Vol. 37 (3) , 149-152
Shortwave Infrared Electro-Optic Frequency Combs Generation Based on Wideband Parametric Conversion
An all-fiber short-wave infrared electro-optic frequency combs (SWIR E-O combs) based on parametric amplification is proposed and experimentally demonstrated by converting the near-infrared combs into the shortwave infrared region. The SWIR E-O combs shows tunable central wavelength and spectral line spacing. Based on the simple combination of the fiber optical parametric amplifier and the Thulium-doped fiber amplifier directly pumped by C-band E-O combs, the power of SWIR E-O combs has been effectively enhanced. In addition, a section of single-mode fiber is used for pulse compression of the C-band E-O combs, and the 10 dB spectral width of the SWIR E-O combs is 17.81nm. The proposed SWIR combs with repetition rates of tens of GHz is of high interest for coherent communication and gas sensing in the SWIR region.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (21) , 7717-7724
High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method
In this paper, a high-resolution and measurement range expanded fiber Bragg grating (FBG) sensing system based on a microwave photonic filter (MPF) with period-breaking interrogation method is illustrated and experimentally demonstrated. With the dispersion of the dispersion compensating fiber (DCF) in the system, the wavelength shift of the FBG in the optical domain can be converted into the notch frequency shift of MPF in the microwave domain, thus realizing high-resolution FBG sensing. Still, the measurement range is limited due to the periodicity of MPF. An optical filter (OF) is inserted into the link that translates the wavelength shift of FBG into the relative amplitude change (RAC) of the MPF. Combined with the frequency shift and RAC of the MPF, this approach can break the periodicity of traditional interrogation methods, overcoming the limitation of measurement range while ensuring high precision. Taking strain sensing as an example, the experimental results show that the sensitivities of the FBG sensing system obtained at the frequencies of 0.9 GHz, 1.9 GHz, and 2.9 GHz are -8.19 kHz/μϵ, -26.57 kHz/μϵ, and -41.52 kHz/μϵ, respectively, and extended measurement ranges are by 1.51 times, 2.96 times, and 4.49 times, respectively. Furthermore, our proposed method, with its simple structure and unique advantages, can achieve adjustable sensitivity and an unrestricted measurement range.
- 11 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (21) , 7717-7724
High-Resolution and Extended-Range Fiber Bragg Grating Sensing System Based on a Microwave Photonic Filter with Period-breaking Interrogation Method
In this paper, a high-resolution and measurement range expanded fiber Bragg grating (FBG) sensing system based on a microwave photonic filter (MPF) with period-breaking interrogation method is illustrated and experimentally demonstrated. With the dispersion of the dispersion compensating fiber (DCF) in the system, the wavelength shift of the FBG in the optical domain can be converted into the notch frequency shift of MPF in the microwave domain, thus realizing high-resolution FBG sensing. Still, the measurement range is limited due to the periodicity of MPF. An optical filter (OF) is inserted into the link that translates the wavelength shift of FBG into the relative amplitude change (RAC) of the MPF. Combined with the frequency shift and RAC of the MPF, this approach can break the periodicity of traditional interrogation methods, overcoming the limitation of measurement range while ensuring high precision. Taking strain sensing as an example, the experimental results show that the sensitivities of the FBG sensing system obtained at the frequencies of 0.9 GHz, 1.9 GHz, and 2.9 GHz are -8.19 kHz/μϵ, -26.57 kHz/μϵ, and -41.52 kHz/μϵ, respectively, and extended measurement ranges are by 1.51 times, 2.96 times, and 4.49 times, respectively. Furthermore, our proposed method, with its simple structure and unique advantages, can achieve adjustable sensitivity and an unrestricted measurement range.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (1) , 477-484
Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach–Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/°C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/°C to 8.44 MHz/°C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59–16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.
- 23 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (1) , 477-484
Frequency Down-Converted and Sensitivity Enhanced Fiber Optic Sensing System Based on Multi-Passband Microwave Photonic Filter by Cascaded Fiber Optic Interferometers
We propose and experimentally demonstrate a frequency down-converted and sensitivity enhanced fiber optic sensing technique based on a multi-passband microwave photonic filter (MPF) employing two cascaded fiber optic interferometers and dispersive medium. The frequency shift of the passband centered at high frequency where the sensing element is related can be down-converted to the frequency shift of low-frequency passband and enjoying narrower 3 dB bandwidth. And even greater frequency shift of passband located at low frequency have been achieved in our proposed fiber optic sensing system. Two interferometers, the Sagnac interferometer (SI), and the Mach–Zehnder interferometer (MZI) are used as a demonstration and the proof-of-concept experiments of temperature measurement are demonstrated, which show that our proposed fiber optic sensing system can down-converted the monitoring passband of SI based MPF from 687 MHz to 437 MHz, while enjoying narrower 3 dB bandwidth and maintaining the same sensitivity (0.81 MHz/°C) that of at 687 MHz, and thus bring convenience to detection. In addition, when taking the SI and MZI both as sensing elements, enhanced and adjustable sensitivity of sensing system can be achieved by adjusting the sensing fiber length of MZI. In our experiment, we have achieved enhanced and tailorable sensitivity from 0.81 MHz/°C to 8.44 MHz/°C, by monitoring the MPF's passband centered at low frequency of 437 MHz, which is about 1.59–16.55 times of the SI based single passband MPF centered at the similar frequency (446 MHz). Lower frequency and higher sensitivity can be obtained by designing the parameters of the fiber optic interferometers, which provides a powerful tool for high sensitivity, high-resolution, and low-cost fiber optic interferometer-based sensor systems.