Lynne M. Hurwitz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lynne M. Hurwitz has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Philip C. Goodman
Department of Radiology, Duke University Medical Center, Box 3808, Durham, NC 27710
4 shared publicationsGreta Toncheva
Department of Radiology, Duke University Medical Center, Box 3808, Durham, NC 27710
3 shared publicationsTerry T. Yoshizumi
Department of Radiology, Duke University Medical Center, Box 3808, Durham, NC 27710
3 shared publicationsCarolyn Lowry
Department of Radiology, Duke University Medical Center, Box 3808, Durham, NC 27710
2 shared publicationsGiao Nguyen
2 shared publicationsAmanda L. Cook
Department of Pediatrics, Division of Pediatric Cardiology, Duke University Medical Center, Durham, NC 27710, USA
1 shared publication
Latest Publications
- 1 January 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (1) , 244-253
Radiation Dose Savings for Adult Pulmonary Embolus 64-MDCT Using Bismuth Breast Shields, Lower Peak Kilovoltage, and Automatic Tube Current Modulation
OBJECTIVE. The purpose of this study was to assess whether radiation dose savings using a lower peak kilovoltage (kVp) setting, bismuth breast shields, and automatic tube current modulation could be achieved while preserving the image quality of MDCT scans obtained to assess for pulmonary embolus (PE).MATERIALS AND METHODS. CT angiography (CTA) examinations were performed to assess for the presence or absence of pulmonary artery emboli using a 64-MDCT scanner with automatic tube current modulation (noise level = 10 HU), two kVp settings (120 and 140 kVp), and bismuth breast shields. Absorbed organ doses were measured using anthropomorphic phantoms and metal oxide semiconductor field effect transistor (MOSFET) detectors. Image quality was assessed quantitatively as well as qualitatively in various anatomic sites of the thorax.RESULTS. Using a lower kVp (120 vs 140 kVp) and automatic tube current modulation resulted in a dose savings of 27% to the breast and 47% to the lungs. The use of a lower kVp (120 kVp...
- 1 January 2009
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 192 (1) , 244-253
Radiation Dose Savings for Adult Pulmonary Embolus 64-MDCT Using Bismuth Breast Shields, Lower Peak Kilovoltage, and Automatic Tube Current Modulation
OBJECTIVE. The purpose of this study was to assess whether radiation dose savings using a lower peak kilovoltage (kVp) setting, bismuth breast shields, and automatic tube current modulation could be achieved while preserving the image quality of MDCT scans obtained to assess for pulmonary embolus (PE).MATERIALS AND METHODS. CT angiography (CTA) examinations were performed to assess for the presence or absence of pulmonary artery emboli using a 64-MDCT scanner with automatic tube current modulation (noise level = 10 HU), two kVp settings (120 and 140 kVp), and bismuth breast shields. Absorbed organ doses were measured using anthropomorphic phantoms and metal oxide semiconductor field effect transistor (MOSFET) detectors. Image quality was assessed quantitatively as well as qualitatively in various anatomic sites of the thorax.RESULTS. Using a lower kVp (120 vs 140 kVp) and automatic tube current modulation resulted in a dose savings of 27% to the breast and 47% to the lungs. The use of a lower kVp (120 kVp...
- 1 December 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 245 (3) , 742-750
Radiation Dose from Contemporary Cardiothoracic Multidetector CT Protocols with an Anthropomorphic Female Phantom: Implications for Cancer Induction
To measure prospectively and directly both organ dose and effective dose (ED) for adult cardiac and pulmonary computed tomographic (CT) angiography by using current clinical protocols for 64-detector CT in an anthropomorphic female phantom and to estimate lifetime attributable risk of breast and lung cancer incidence on the basis of measured ED and organ dose. Cardiac and pulmonary 64-detector CT angiography was performed by using current clinical protocols to evaluate the pulmonary veins (electrocardiographically [ECG] gated, 64 sections at 0.625-mm collimation, 120 kVp, 300 mA, 0.35-second tube rotation), native coronary arteries (ECG gated; 64 sections at 0.625 mm; 120 kVp; maximum current, 500-750 mA; minimum, 100-350 mA; 0.35-second tube rotation) and pulmonary embolus (64 sections at 1.25 mm, 140 kVp, 645 mA, 0.5-second tube rotation). Absorbed organ doses were measured by using an anthropomorphic female phantom and metal oxide semiconductor field effect transistor detectors. ED was calculated from measured organ doses and the dose-length product. ED for current adult cardiac and pulmonary 64-detector CT angiography protocols were 12.4-31.8 mSv. Overall, skin, breast, and esophagus and heart had the highest recorded absorbed organ doses. Relative risk for breast cancer incidence for girls and women was 1.004-1.042 for a single examination. Relative risk for lung cancer incidence for men and women was 1.005-1.076 from a single examination. EDs and organ doses from 64-detector CT are higher than those previously reported for adult cardiac and pulmonary CT angiography protocols. Risk for breast and lung cancer induction from these studies is greatest for the younger patient population.
- 1 December 2007
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 245 (3) , 742-750
Radiation Dose from Contemporary Cardiothoracic Multidetector CT Protocols with an Anthropomorphic Female Phantom: Implications for Cancer Induction
To measure prospectively and directly both organ dose and effective dose (ED) for adult cardiac and pulmonary computed tomographic (CT) angiography by using current clinical protocols for 64-detector CT in an anthropomorphic female phantom and to estimate lifetime attributable risk of breast and lung cancer incidence on the basis of measured ED and organ dose. Cardiac and pulmonary 64-detector CT angiography was performed by using current clinical protocols to evaluate the pulmonary veins (electrocardiographically [ECG] gated, 64 sections at 0.625-mm collimation, 120 kVp, 300 mA, 0.35-second tube rotation), native coronary arteries (ECG gated; 64 sections at 0.625 mm; 120 kVp; maximum current, 500-750 mA; minimum, 100-350 mA; 0.35-second tube rotation) and pulmonary embolus (64 sections at 1.25 mm, 140 kVp, 645 mA, 0.5-second tube rotation). Absorbed organ doses were measured by using an anthropomorphic female phantom and metal oxide semiconductor field effect transistor detectors. ED was calculated from measured organ doses and the dose-length product. ED for current adult cardiac and pulmonary 64-detector CT angiography protocols were 12.4-31.8 mSv. Overall, skin, breast, and esophagus and heart had the highest recorded absorbed organ doses. Relative risk for breast cancer incidence for girls and women was 1.004-1.042 for a single examination. Relative risk for lung cancer incidence for men and women was 1.005-1.076 from a single examination. EDs and organ doses from 64-detector CT are higher than those previously reported for adult cardiac and pulmonary CT angiography protocols. Risk for breast and lung cancer induction from these studies is greatest for the younger patient population.
- 1 September 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (3) , 592-601
Right Heart Dilatation in Adults: Congenital Causes
OBJECTIVE. The purpose of this article is to illustrate the common congenital cardiac lesions that are characterized by right-sided heart enlargement that may be seen on routine thoracic or cardiac imaging.CONCLUSION. A systematic approach to the evaluation of the right heart and an understanding of the congenital abnormalities causing right chamber enlargement will allow the radiologist to diagnose unsuspected cardiac abnormalities on routine clinical thoracic and cardiac imaging as well as accurately identify these defects on dedicated cardiac CT or MRI examinations.
- 1 September 2007
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 189 (3) , 592-601
Right Heart Dilatation in Adults: Congenital Causes
OBJECTIVE. The purpose of this article is to illustrate the common congenital cardiac lesions that are characterized by right-sided heart enlargement that may be seen on routine thoracic or cardiac imaging.CONCLUSION. A systematic approach to the evaluation of the right heart and an understanding of the congenital abnormalities causing right chamber enlargement will allow the radiologist to diagnose unsuspected cardiac abnormalities on routine clinical thoracic and cardiac imaging as well as accurately identify these defects on dedicated cardiac CT or MRI examinations.
- 1 July 2007
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 31 (4) , 544-549
Effective Dose Determination Using an Anthropomorphic Phantom and Metal Oxide Semiconductor Field Effect Transistor Technology for Clinical Adult Body Multidetector Array Computed Tomography Protocols
Purpose: To determine the organ doses and total body effective dose (ED) delivered to an anthropomorphic phantom by multidetector array computed tomography (MDCT) when using standard clinical adult body imaging protocols. Materials and Methods: Metal oxide semiconductor field effect transistor (MOSFET) technology was applied during the scanning of a female anthropomorphic phantom to determine 20 organ doses delivered during clinical body computed tomography (CT) imaging protocols. A 16-row MDCT scanner (LightSpeed, General Electric Healthcare, Milwaukee, Wis) was used. Effective dose was calculated as the sum of organ doses multiplied by a weighting factor determinant found in the International Commission on Radiological Protection Publication 60. Volume CT dose index and dose length product (DLP) values were recorded at the same time for the same scan. Results: Effective dose (mSv) for body MDCT imaging protocols were as follows: standard chest CT, 6.80 ± 0.6; pulmonary embolus CT, 13.7 ± 0.4; gated coronary CT angiography, 20.6 ± 0.4; standard abdomen and pelvic CT, 13.3 + 1.0; renal stone CT, 4.51 + 0.45. Effective dose calculated by direct organ measurements in the phantom was 14% to 37% greater than those determined by the DLP method. Conclusions: Effective dose calculated by the DLP method underestimates ED as compared with direct organ measurements for the same CT examination. Organ doses and total body ED are higher than previously reported for MDCT clinical body imaging protocols.
- 1 July 2007
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 31 (4) , 544-549
Effective Dose Determination Using an Anthropomorphic Phantom and Metal Oxide Semiconductor Field Effect Transistor Technology for Clinical Adult Body Multidetector Array Computed Tomography Protocols
Purpose: To determine the organ doses and total body effective dose (ED) delivered to an anthropomorphic phantom by multidetector array computed tomography (MDCT) when using standard clinical adult body imaging protocols. Materials and Methods: Metal oxide semiconductor field effect transistor (MOSFET) technology was applied during the scanning of a female anthropomorphic phantom to determine 20 organ doses delivered during clinical body computed tomography (CT) imaging protocols. A 16-row MDCT scanner (LightSpeed, General Electric Healthcare, Milwaukee, Wis) was used. Effective dose was calculated as the sum of organ doses multiplied by a weighting factor determinant found in the International Commission on Radiological Protection Publication 60. Volume CT dose index and dose length product (DLP) values were recorded at the same time for the same scan. Results: Effective dose (mSv) for body MDCT imaging protocols were as follows: standard chest CT, 6.80 ± 0.6; pulmonary embolus CT, 13.7 ± 0.4; gated coronary CT angiography, 20.6 ± 0.4; standard abdomen and pelvic CT, 13.3 + 1.0; renal stone CT, 4.51 + 0.45. Effective dose calculated by direct organ measurements in the phantom was 14% to 37% greater than those determined by the DLP method. Conclusions: Effective dose calculated by the DLP method underestimates ED as compared with direct organ measurements for the same CT examination. Organ doses and total body ED are higher than previously reported for MDCT clinical body imaging protocols.
- 1 April 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (4) , 1245-1246
Intraaortic Balloon Pump Location and Aortic Dissection
- 1 April 2005
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 184 (4) , 1245-1246
Intraaortic Balloon Pump Location and Aortic Dissection