Bo Zhang
Bo Zhang has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Liu Yapei
Pinggao Group Co., Ltd, State Grid Corporation of China Pingdingshan City P. R. China
2 shared publicationsWang Zhijun
Pinggao Group Co., Ltd, State Grid Corporation of China Pingdingshan City P. R. China
2 shared publicationsYao Yongqi
Pinggao Group Co., Ltd, State Grid Corporation of China Pingdingshan City P. R. China
2 shared publicationsYujing Guo
Pinggao Group Co., Ltd. Pingdingshan People's Republic of China
2 shared publicationsZhong Jianying
Pinggao Group Co., Ltd, State Grid Corporation of China Pingdingshan City P. R. China
2 shared publicationsGang Sun
State Grid Corporation of China Beijing People's Republic of China
1 shared publication
Latest Publications
- 25 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (4) , 496-504
Research on Parameters Optimization of High Voltage Circuit Breaker Nozzle Based on Image Recognition and Deep Learning
Traditional modeling and optimization methods for high voltage equipment, specially, circuit breaker components and nozzles, require manual testing and improvement of a large number of parameters, and the efficiency is relatively low. The strong processing power of artificial intelligence technology in the identification and prediction of complex systems is an effective solution in such case. This paper presents the optimization approach of image recognition combined with deep learning for circuit breaker nozzle. The nozzle model was conducted using the high Mach flow model in a commercial software (COMSOL Multiphysics 5.4) to study the gas flow state and behavior during cold flow, and obtains Shock wave image recognition model of the nozzle chamber based on the convolutional neural network (CNN) method of multiscale layered features. On the basis of effective image recognition, combined with deep learning Convolutional Recurrent Neural Network (CRNN), the image sequence under different parameters is sent to the convolutional layer for feature extraction, and then the feature map is input into the loop. The prediction sequence is obtained through the layer, and finally the relationship between the kinematic parameters of the nozzle and the internal gas flow state is predicted through the prediction layer. Results indicated, according to the prediction of CRNN, the range of the throat length should be between 7 and 13 mm and the angle should be between 8 ∼ 15°. The presented method could be also used for similar materials and components, with certain universality. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 25 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (4) , 496-504
Research on Parameters Optimization of High Voltage Circuit Breaker Nozzle Based on Image Recognition and Deep Learning
Traditional modeling and optimization methods for high voltage equipment, specially, circuit breaker components and nozzles, require manual testing and improvement of a large number of parameters, and the efficiency is relatively low. The strong processing power of artificial intelligence technology in the identification and prediction of complex systems is an effective solution in such case. This paper presents the optimization approach of image recognition combined with deep learning for circuit breaker nozzle. The nozzle model was conducted using the high Mach flow model in a commercial software (COMSOL Multiphysics 5.4) to study the gas flow state and behavior during cold flow, and obtains Shock wave image recognition model of the nozzle chamber based on the convolutional neural network (CNN) method of multiscale layered features. On the basis of effective image recognition, combined with deep learning Convolutional Recurrent Neural Network (CRNN), the image sequence under different parameters is sent to the convolutional layer for feature extraction, and then the feature map is input into the loop. The prediction sequence is obtained through the layer, and finally the relationship between the kinematic parameters of the nozzle and the internal gas flow state is predicted through the prediction layer. Results indicated, according to the prediction of CRNN, the range of the throat length should be between 7 and 13 mm and the angle should be between 8 ∼ 15°. The presented method could be also used for similar materials and components, with certain universality. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 23 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (4) , 511-518
Research on Steady‐State Thermal Behavior ofSF6/N2andCF3I/N2Mixtures in High Voltage Gas‐Insulated Lines (GIL)
Gas‐insulated lines (GIL) are widely used due to their many advantages in power plants and substations. The security and reliability of GIL is achieved by continues testing and monitoring. The main fault in the GIL compartments is overheating, which is rarely to occur, nonetheless, it cannot be ignored. In the present study, GIL steady‐state thermal behavior was investigated. For this reason, a multiphysics finite element model (FEM) was built to analyze the magneto‐hydro‐thermal characteristics of the GIL insulation gas. The simulation coupling includes the electromagnetic field, flow field and thermal heat transfer field. SF6/N2and CF3I/N2mixtures were studied and the influence of different gas properties on the magnetic flux density, heat distribution and flow velocity had been investigated. The results were compared to an experimental setup to validate the model calculations. Temperature rise tests have been conducted on the GIL inner and outer shell. The measurements were in good agreement with the simulation results. Finally, the presented work is also to serve as a good reference in future design and optimization of GIL structure. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- 23 February 2021
- Published by Wiley in IEEJ Transactions on Electrical and Electronic Engineering
- Vol. 16 (4) , 511-518
Research on Steady‐State Thermal Behavior ofSF6/N2andCF3I/N2Mixtures in High Voltage Gas‐Insulated Lines (GIL)
Gas‐insulated lines (GIL) are widely used due to their many advantages in power plants and substations. The security and reliability of GIL is achieved by continues testing and monitoring. The main fault in the GIL compartments is overheating, which is rarely to occur, nonetheless, it cannot be ignored. In the present study, GIL steady‐state thermal behavior was investigated. For this reason, a multiphysics finite element model (FEM) was built to analyze the magneto‐hydro‐thermal characteristics of the GIL insulation gas. The simulation coupling includes the electromagnetic field, flow field and thermal heat transfer field. SF6/N2and CF3I/N2mixtures were studied and the influence of different gas properties on the magnetic flux density, heat distribution and flow velocity had been investigated. The results were compared to an experimental setup to validate the model calculations. Temperature rise tests have been conducted on the GIL inner and outer shell. The measurements were in good agreement with the simulation results. Finally, the presented work is also to serve as a good reference in future design and optimization of GIL structure. © 2021 Institute of Electrical Engineers of Japan. Published by Wiley Periodicals LLC.
- Open Access
- 14 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2610-2614
Charge transport and accumulation around the cone‐type insulator in SF 6 ‐filled 550 kV DC GIL
The gas‐insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability and environmental friendliness. It is suitable for the high voltage direct current (HVDC) power transmission of hydropower stations or nuclear power stations. However, due to the serious surface charge accumulation problem of the cone‐type insulator under DC, its flashover performance is reduced, which restricts the engineering application of HVDC GIL. In this study, a charge transport model of SF 6 gas and epoxy is established for a 550 kV cone‐type insulator and the charge accumulation characteristics of the concave and convex surfaces of the cone‐type insulator are obtained. Computational results show that the gas conductivity around the cone‐type insulator is not uniform due to the charged particles drifting under a constant electric field. Compared with the AC, the difference of the electric field distribution caused by charge accumulation under DC stress is analysed. Based on the established model, the influence of the gas ion‐pair generation rate and epoxy volume conductivity on the charge accumulation on the surface of 550 kV cone‐type insulator was studied. This study is helpful to further optimise the geometry and material properties of the cone‐type insulator and reduce the surface charge accumulation and critical area electric field to improve HVDC GIL insulation design.
- 14 January 2019
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2610-2614
Open AccessCharge transport and accumulation around the cone‐type insulator in SF 6 ‐filled 550 kV DC GIL
The gas‐insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability and environmental friendliness. It is suitable for the high voltage direct current (HVDC) power transmission of hydropower stations or nuclear power stations. However, due to the serious surface charge accumulation problem of the cone‐type insulator under DC, its flashover performance is reduced, which restricts the engineering application of HVDC GIL. In this study, a charge transport model of SF 6 gas and epoxy is established for a 550 kV cone‐type insulator and the charge accumulation characteristics of the concave and convex surfaces of the cone‐type insulator are obtained. Computational results show that the gas conductivity around the cone‐type insulator is not uniform due to the charged particles drifting under a constant electric field. Compared with the AC, the difference of the electric field distribution caused by charge accumulation under DC stress is analysed. Based on the established model, the influence of the gas ion‐pair generation rate and epoxy volume conductivity on the charge accumulation on the surface of 550 kV cone‐type insulator was studied. This study is helpful to further optimise the geometry and material properties of the cone‐type insulator and reduce the surface charge accumulation and critical area electric field to improve HVDC GIL insulation design.
- Open Access
- 13 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2324-2327
Motion of metallic particle near the conical insulator of UHVAC gas‐insulated transmission line
The UHV gas‐insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability, and environmental friendliness. It is suitable for the power transmission of hydropower stations and nuclear power stations and the restricted environmental or geographical conditions. China is constructing a single‐phase length of 5.8 km from Suzhou to Nantong UHVAC GIL over the Yangtze River project. However, due to the large size of the UHV GIL, the long standard units, and the large capacity, it is of great significance to study the motion of metallic particles near the disc insulator for the safety and stability of UHV GIL. Taking the typical insulation structure of UHVAC GIL as an example, a numerical model of the movement of spherical metal particles near the conical insulator was established. The influence of different initial positions, different loading voltages, and different particle quality on the motion characteristics of the particles was analysed. The conclusions of the study provide theoretical support for the design of insulation structure and engineering application of UHVAC GIL.
- 13 December 2018
- Published by Institution of Engineering and Technology (IET) in The Journal of Engineering
- Vol. 2019 (16) , 2324-2327
Open AccessMotion of metallic particle near the conical insulator of UHVAC gas‐insulated transmission line
The UHV gas‐insulated transmission line (GIL) has the advantages of large transmission capacity, high operation reliability, and environmental friendliness. It is suitable for the power transmission of hydropower stations and nuclear power stations and the restricted environmental or geographical conditions. China is constructing a single‐phase length of 5.8 km from Suzhou to Nantong UHVAC GIL over the Yangtze River project. However, due to the large size of the UHV GIL, the long standard units, and the large capacity, it is of great significance to study the motion of metallic particles near the disc insulator for the safety and stability of UHV GIL. Taking the typical insulation structure of UHVAC GIL as an example, a numerical model of the movement of spherical metal particles near the conical insulator was established. The influence of different initial positions, different loading voltages, and different particle quality on the motion characteristics of the particles was analysed. The conclusions of the study provide theoretical support for the design of insulation structure and engineering application of UHVAC GIL.