Luca Bifano
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luca Bifano has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Gerhard Fischerauer
Fakultät für Ingenieurwissenschaften , Universität Bayreuth , 95440 Bayreuth , Germany
9 shared publications Alice Fischerauer
Chair of Measurement and Control Systems, University of Bayreuth, 95447 Bayreuth, Germany
2 shared publicationsGerhard Fischerauer
Chair of Measurement and Control Systems, Fakultät für Ingenieurwissenschaften , 332894 Universität Bayreuth , 95440 Bayreuth , Germany
2 shared publications- Ronny Peter
Chair of Measurement and Control Systems, University of Bayreuth, 95447 Bayreuth, Germany
2 shared publications Valentin Meiler
Chair of Measurement and Control Systems , Fakultät für Ingenieurwissenschaften, Universität Bayreuth , 95440 Bayreuth , Germany
2 shared publications- Xiaohu Ma
Chair of Measurement and Control Systems, Faculty of Engineering Science, University of Bayreuth, 95440 Bayreuth, Germany
2 shared publications
Latest Publications
- 26 October 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
Design of a digital twin for an impedance-based microplastic sensor using a flow-through method
Detecting microplastic in the field is the first step to solve the microplastic challenge. To achieve this, innovative sensors must be developed. One alternative to standard laboratory methods is a sensor comprising a flow-through cell with electrodes the frequency-dependent impedance of which depends on the presence and type of particle in the cell. This has already been described in the literature. To speed up the development of such sensors and identify the influence of design details, it is advantageous to have a digital twin of the sensor. So, this work focuses on the design of a digital finite-element (FE) twin for this microplastic sensor, with the aim of predicting the output signal of the sensor derived from changes in the impedance spectrum (magnitude and phase) when a particle passes through the sensor. Ideally, it even suffices to work with features of the spectrum (such as the impedance at 2 MHz) rather than the entire spectrum; such features have to be identified first, and this represents another use of our digital twin. In our investigations, the material parameters from the standard database of the FE tool used (Ansys Electronics) were chosen to incorporate the influence of the electrical conductivity of water into the simulation. It was found that the simulation results corresponded to the measurement results during sensor characterization, i.e., when recording the impedance of the sensor with pure water filling over a frequency range from 20 Hz to 2 MHz. The signals of the sensor obtained from measurements due to a particle in the sensor were confirmed by the simulation. The simulated impedance magnitude described the measured signals both qualitatively and quantitatively. For the impedance phase, this was true only qualitatively. It was found that the particle position and size have a decisive influence on the impedance of the sensor. Effects observed in the measurements (e.g., a negative change in the magnitude of the impedance, when a particle enters the sensor) could be attributed to the particle position or size based on the simulation results. In the future, the digital twin that has been created will allow the effects of changes to the sensor geometry to be analysed digitally first (e.g., a higher sensitivity and/or selectivity on a certain polymer), before the sensor is physically built and measured. While searching the optimal sensor geometry the digital twin reduces the measurement effort and speeds up the development process.
- 26 October 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
Design of a digital twin for an impedance-based microplastic sensor using a flow-through method
Detecting microplastic in the field is the first step to solve the microplastic challenge. To achieve this, innovative sensors must be developed. One alternative to standard laboratory methods is a sensor comprising a flow-through cell with electrodes the frequency-dependent impedance of which depends on the presence and type of particle in the cell. This has already been described in the literature. To speed up the development of such sensors and identify the influence of design details, it is advantageous to have a digital twin of the sensor. So, this work focuses on the design of a digital finite-element (FE) twin for this microplastic sensor, with the aim of predicting the output signal of the sensor derived from changes in the impedance spectrum (magnitude and phase) when a particle passes through the sensor. Ideally, it even suffices to work with features of the spectrum (such as the impedance at 2 MHz) rather than the entire spectrum; such features have to be identified first, and this represents another use of our digital twin. In our investigations, the material parameters from the standard database of the FE tool used (Ansys Electronics) were chosen to incorporate the influence of the electrical conductivity of water into the simulation. It was found that the simulation results corresponded to the measurement results during sensor characterization, i.e., when recording the impedance of the sensor with pure water filling over a frequency range from 20 Hz to 2 MHz. The signals of the sensor obtained from measurements due to a particle in the sensor were confirmed by the simulation. The simulated impedance magnitude described the measured signals both qualitatively and quantitatively. For the impedance phase, this was true only qualitatively. It was found that the particle position and size have a decisive influence on the impedance of the sensor. Effects observed in the measurements (e.g., a negative change in the magnitude of the impedance, when a particle enters the sensor) could be attributed to the particle position or size based on the simulation results. In the future, the digital twin that has been created will allow the effects of changes to the sensor geometry to be analysed digitally first (e.g., a higher sensitivity and/or selectivity on a certain polymer), before the sensor is physically built and measured. While searching the optimal sensor geometry the digital twin reduces the measurement effort and speeds up the development process.
- 19 January 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (3-4) , 128-139
Temperature influence on electrical impedance spectra used to monitor dry molding materials in the foundry industry
Condition monitoring of molding material preparation processes in foundries can help to improve the processes in terms of energy consumption and use of resources. Electrical impedance spectroscopy is a suitable method for this purpose but influence effects must be carefully taken into account in field applications. Temperature, in particular, plays an important role in foundry processes and can be expected to strongly interfere with the extraction of condition information from impedance spectra. To shed light on the details of this temperature influence, we have recorded impedance spectra of measuring cells filled with molding material (quartz sand, used core sand, and regenerated material) in the frequency range from 500 Hz to 1 MHz and have evaluated the spectra with respect to their reproducibility and the quantifiability of their temperature dependence. It was found that the impedances could be measured reproducibly across the entire frequency range, with reproducibility increasing with frequency. In addition, the temperature dependence was observed to be a function of both of the molding-material composition and the frequency. Numerically, the temperature caused impedance magnitude changes of up to 34 % in the worst cases. This suggests that one should either control the temperature of molding-material samples during measurement or that the feature combination of impedance spectrum plus temperature should be used in data interpretation.
- 19 January 2026
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 93 (3-4) , 128-139
Temperature influence on electrical impedance spectra used to monitor dry molding materials in the foundry industry
Condition monitoring of molding material preparation processes in foundries can help to improve the processes in terms of energy consumption and use of resources. Electrical impedance spectroscopy is a suitable method for this purpose but influence effects must be carefully taken into account in field applications. Temperature, in particular, plays an important role in foundry processes and can be expected to strongly interfere with the extraction of condition information from impedance spectra. To shed light on the details of this temperature influence, we have recorded impedance spectra of measuring cells filled with molding material (quartz sand, used core sand, and regenerated material) in the frequency range from 500 Hz to 1 MHz and have evaluated the spectra with respect to their reproducibility and the quantifiability of their temperature dependence. It was found that the impedances could be measured reproducibly across the entire frequency range, with reproducibility increasing with frequency. In addition, the temperature dependence was observed to be a function of both of the molding-material composition and the frequency. Numerically, the temperature caused impedance magnitude changes of up to 34 % in the worst cases. This suggests that one should either control the temperature of molding-material samples during measurement or that the feature combination of impedance spectrum plus temperature should be used in data interpretation.
- 1 August 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (s1) , 72-77
Anwendung einer Support Vector Machine zur Überwachung der Altsandregeneration mit EIS-Daten
Zusammenfassung: Die Altsandregeneration stellt einen Prozess zur Wiederaufbereitung von verwendetem Formstoff im Formstoffkreislauf von Gießereien dar. Zurzeit wird ihre Überwachung alleine durch Labormethoden realisiert, was mit einem hohen Zeit- und Personalaufwand verbunden ist. Um den Prozess überwachen und automatisch regeln zu können, wurde in dieser Arbeit ein Zusammenspiel aus elektrischer Impedanzspektroskopie (EIS) als Messmethode und Support Vector Machines (SVM) als Auswerteverfahren untersucht, da es sich bei beiden Methoden um prinzipiell inlinefähige Werkzeuge handelt. Ziel der Untersuchung war es, die Leistungsfähigkeit von EIS + SVM bei der Überwachung des Prozessfortschritts zu beurteilen. Aus den Impedanzspektren extrahierte Merkmale wurden zum Entwurf einer SVM für die Klassifikation und darüber hinaus für eine Regression verwendet. Dazu wurden zu verschiedenen Zeitpunkten entnommene Zwischenstufen von Regeneraten aus einem schonenden (R1) und einem intensiven (R2) Regenerationsprozess impedimetrisch vermessen. Bei Prozessende wurde das Regenerat aus R2 als vollständig regeneriert definiert. Mit der SVM wurde abgeschätzt, welchem Zustand aus R2 das Regenerat aus R1 entsprach. Dabei zeigte sich, dass sowohl die Klassifikation als auch die Regression plausible Lösungen lieferten. Die SVM setzte den Regeneratzustand am Ende von Prozess R1 einem nur zur Hälfte regenerierten Altsand aus Prozess R2 gleich. Diese und andere SVM-Aussagen konnten über Sandlabordaten bestätigt werden.
- 1 August 2024
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 91 (s1) , 72-77
Anwendung einer Support Vector Machine zur Überwachung der Altsandregeneration mit EIS-Daten
Zusammenfassung: Die Altsandregeneration stellt einen Prozess zur Wiederaufbereitung von verwendetem Formstoff im Formstoffkreislauf von Gießereien dar. Zurzeit wird ihre Überwachung alleine durch Labormethoden realisiert, was mit einem hohen Zeit- und Personalaufwand verbunden ist. Um den Prozess überwachen und automatisch regeln zu können, wurde in dieser Arbeit ein Zusammenspiel aus elektrischer Impedanzspektroskopie (EIS) als Messmethode und Support Vector Machines (SVM) als Auswerteverfahren untersucht, da es sich bei beiden Methoden um prinzipiell inlinefähige Werkzeuge handelt. Ziel der Untersuchung war es, die Leistungsfähigkeit von EIS + SVM bei der Überwachung des Prozessfortschritts zu beurteilen. Aus den Impedanzspektren extrahierte Merkmale wurden zum Entwurf einer SVM für die Klassifikation und darüber hinaus für eine Regression verwendet. Dazu wurden zu verschiedenen Zeitpunkten entnommene Zwischenstufen von Regeneraten aus einem schonenden (R1) und einem intensiven (R2) Regenerationsprozess impedimetrisch vermessen. Bei Prozessende wurde das Regenerat aus R2 als vollständig regeneriert definiert. Mit der SVM wurde abgeschätzt, welchem Zustand aus R2 das Regenerat aus R1 entsprach. Dabei zeigte sich, dass sowohl die Klassifikation als auch die Regression plausible Lösungen lieferten. Die SVM setzte den Regeneratzustand am Ende von Prozess R1 einem nur zur Hälfte regenerierten Altsand aus Prozess R2 gleich. Diese und andere SVM-Aussagen konnten über Sandlabordaten bestätigt werden.
- Open Access
Classification of Sand-Binder Mixtures from the Foundry Industry Using Electrical Impedance Spectroscopy and Support Vector Machines
Molding sand mixtures used in the foundry industry consist of various sands (quartz sands, chromite sands, etc.) and additives such as bentonite. The optimum control of the processes involved in using the mixtures and in their regeneration after the casting requires an efficient in-line monitoring method that is not available today. We are investigating whether such a method can be based on electrical impedance spectroscopy (EIS). To establish a database, we have characterized various sand mixtures by EIS in the frequency range from 0.5 kHz to 1 MHz under laboratory conditions. Attempts at classifying the different molding sand mixtures by support vector machines (SVM) show encouraging results. Already high assignment accuracies (above 90%) could even be improved with suitable feature selection (sequential feature selection). At the same time, the standard uncertainty of the SVM results is low, i.e., data assigned to a class by the presented SVMs have a high probability of being assigned correctly. The application of EIS with subsequent evaluation by machine learning (machine-learning-enhanced EIS, MLEIS) in the field of bulk material monitoring in the foundry industry appears possible.
Open AccessClassification of Sand-Binder Mixtures from the Foundry Industry Using Electrical Impedance Spectroscopy and Support Vector Machines
Molding sand mixtures used in the foundry industry consist of various sands (quartz sands, chromite sands, etc.) and additives such as bentonite. The optimum control of the processes involved in using the mixtures and in their regeneration after the casting requires an efficient in-line monitoring method that is not available today. We are investigating whether such a method can be based on electrical impedance spectroscopy (EIS). To establish a database, we have characterized various sand mixtures by EIS in the frequency range from 0.5 kHz to 1 MHz under laboratory conditions. Attempts at classifying the different molding sand mixtures by support vector machines (SVM) show encouraging results. Already high assignment accuracies (above 90%) could even be improved with suitable feature selection (sequential feature selection). At the same time, the standard uncertainty of the SVM results is low, i.e., data assigned to a class by the presented SVMs have a high probability of being assigned correctly. The application of EIS with subsequent evaluation by machine learning (machine-learning-enhanced EIS, MLEIS) in the field of bulk material monitoring in the foundry industry appears possible.
- 22 June 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (11) , 725-735
Machine learning approach for impedance locus uncertainties
This work deals with the determination of the uncertainty of measurement data, determined by electrical impedance spectroscopy. Four different types of sand were measured impedimetrically in a measuring cell designed as a plate capacitor in a frequency range from 20 Hz to 1 MHz. The measuring cell was filled ten times with each sand and 20 impedance spectra were recorded for each filling. The uncertainty at each frequency was determined from the measurement data. It was found that the measurement data variance with a given measuring-cell filling was negligibly small. However, it increased by a factor of up to 100 when the measuring cell was repeatedly emptied and re-filled with the same material. We propose a way to estimate a continuous approximation of the uncertainty band of the impedance locus in the complex plane from the discrete uncertainties at each frequency. It uses a Support Vector Machine (SVM) to generate a regression curve using the discrete uncertainties. The result of the regression was used to estimate the uncertainties of an average impedance locus. The said machine learning tool can handle large amounts of data, classes, and influencing variables. In this manner, it can help to identify cause-effect relationships. Furthermore, at the end of this work a possibility to estimate a continuous uncertainty band along the impedance locus curve via SVM regression is shown. This is an extension to the common methodology in literature, where the uncertainty is only determined at selected individual points of the impedance spectrum.
- 22 June 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (11) , 725-735
Machine learning approach for impedance locus uncertainties
This work deals with the determination of the uncertainty of measurement data, determined by electrical impedance spectroscopy. Four different types of sand were measured impedimetrically in a measuring cell designed as a plate capacitor in a frequency range from 20 Hz to 1 MHz. The measuring cell was filled ten times with each sand and 20 impedance spectra were recorded for each filling. The uncertainty at each frequency was determined from the measurement data. It was found that the measurement data variance with a given measuring-cell filling was negligibly small. However, it increased by a factor of up to 100 when the measuring cell was repeatedly emptied and re-filled with the same material. We propose a way to estimate a continuous approximation of the uncertainty band of the impedance locus in the complex plane from the discrete uncertainties at each frequency. It uses a Support Vector Machine (SVM) to generate a regression curve using the discrete uncertainties. The result of the regression was used to estimate the uncertainties of an average impedance locus. The said machine learning tool can handle large amounts of data, classes, and influencing variables. In this manner, it can help to identify cause-effect relationships. Furthermore, at the end of this work a possibility to estimate a continuous uncertainty band along the impedance locus curve via SVM regression is shown. This is an extension to the common methodology in literature, where the uncertainty is only determined at selected individual points of the impedance spectrum.
- 23 March 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (6) , 374-387
Detection of microplastics in water using electrical impedance spectroscopy and support vector machines
The detection of microplastics in water requires a series of processes (sample collection, purification, and preparation) until a sample can be analyzed in the laboratory. To shorten this process chain, we are investigating whether electrical impedance spectroscopy (EIS) enhanced by a classifier based on support vector machine (SVM) can be applied to the problem of microplastics detection. Results with suspensions of polypropylene (PP) and polyolefin (PO) in deionized water proved promising: The relative permittivities extracted from the measured impedances agree with literature data. The subsequent classification of measured impedances by SVM shows that the three classes “no plastic” (below the detection limit of 1 g plastic per filling), “PP” and “PO” can be distinguished securely independent of the background medium water. Mixtures of PO and PP were not examined, i.e. either PO or PP was filled into the measuring cell. An SVM regression performed after the SVM classification yields the microplastic concentration of the respective sample. Further tests with varying salinity and content of organic or biological material in the water confirmed the good results. We conclude that EIS in combination with machine learning (MLEIS) seems to be a promising approach for in situ detection of microplastics and certainly warrants further research activities.
- 23 March 2023
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 90 (6) , 374-387
Detection of microplastics in water using electrical impedance spectroscopy and support vector machines
The detection of microplastics in water requires a series of processes (sample collection, purification, and preparation) until a sample can be analyzed in the laboratory. To shorten this process chain, we are investigating whether electrical impedance spectroscopy (EIS) enhanced by a classifier based on support vector machine (SVM) can be applied to the problem of microplastics detection. Results with suspensions of polypropylene (PP) and polyolefin (PO) in deionized water proved promising: The relative permittivities extracted from the measured impedances agree with literature data. The subsequent classification of measured impedances by SVM shows that the three classes “no plastic” (below the detection limit of 1 g plastic per filling), “PP” and “PO” can be distinguished securely independent of the background medium water. Mixtures of PO and PP were not examined, i.e. either PO or PP was filled into the measuring cell. An SVM regression performed after the SVM classification yields the microplastic concentration of the respective sample. Further tests with varying salinity and content of organic or biological material in the water confirmed the good results. We conclude that EIS in combination with machine learning (MLEIS) seems to be a promising approach for in situ detection of microplastics and certainly warrants further research activities.
- Open Access
Evaluation of Electrical Impedance Spectra by Long Short-Term Memory to Estimate Nitrate Concentrations in Soil
Monitoring the nitrate concentration in soil is crucial to guide the use of nitrate-based fertilizers. This study presents the characteristics of an impedance sensor used to estimate the nitrate concentration in soil based on the sensitivity of the soil dielectric constant to ion conductivity and on electrical double layer effects at electrodes. The impedance of synthetic sandy soil samples with nitrate nitrogen concentrations ranging from 0 to 15 mg/L was measured at frequencies between 20 Hz and 5 kHz and noticeable conductance and susceptance effects were observed. Long short-term memory (LSTM), a variant of recurrent artificial neural networks (RNN), was investigated with respect to its suitability to extract nitrate concentrations from the measured impedance spectra and additional physical properties of the soils, such as mass density and water content. Both random forest and LSTM were tested as feature selection methods. Then, numerous LSTMs were trained to estimate the nitrate concentrations in the soils. To increase estimation accuracy, hyperparameters were optimized with Bayesian optimization. The resulting optimal regression model showed coefficients of determination between true and predicted nitrate concentrations as high as 0.95. Thus, it could be demonstrated that the system has the potential to monitor nitrate concentrations in soils in real time and in situ.
Open AccessEvaluation of Electrical Impedance Spectra by Long Short-Term Memory to Estimate Nitrate Concentrations in Soil
Monitoring the nitrate concentration in soil is crucial to guide the use of nitrate-based fertilizers. This study presents the characteristics of an impedance sensor used to estimate the nitrate concentration in soil based on the sensitivity of the soil dielectric constant to ion conductivity and on electrical double layer effects at electrodes. The impedance of synthetic sandy soil samples with nitrate nitrogen concentrations ranging from 0 to 15 mg/L was measured at frequencies between 20 Hz and 5 kHz and noticeable conductance and susceptance effects were observed. Long short-term memory (LSTM), a variant of recurrent artificial neural networks (RNN), was investigated with respect to its suitability to extract nitrate concentrations from the measured impedance spectra and additional physical properties of the soils, such as mass density and water content. Both random forest and LSTM were tested as feature selection methods. Then, numerous LSTMs were trained to estimate the nitrate concentrations in the soils. To increase estimation accuracy, hyperparameters were optimized with Bayesian optimization. The resulting optimal regression model showed coefficients of determination between true and predicted nitrate concentrations as high as 0.95. Thus, it could be demonstrated that the system has the potential to monitor nitrate concentrations in soils in real time and in situ.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (5) , 4863-4872
Approaches to Detect Microplastics in Water Using Electrical Impedance Measurements and Support Vector Machines
We propose electrical impedance spectroscopy enhanced by machine learning, in particular support vector machines, as a non-invasive, in-situ method for detecting microplastics in water and as an alternative to slow, expensive laboratory measurements. The primary measurand is the complex-valued electrical impedance of a water-filled measuring cell. We carried out stationary measurements on numerous water samples contaminated with different plastic concentrations in a cylindrical measuring cell and in the frequency range from 20 Hz to 2 MHz. The effects of various influence quantities, such as the concentration of organic material (1.0 %, 3.0 %, 5.0 %) or the salinity of water (0.5 %, 1.0 %, 3.5 %), were also investigated. Measurements at 2 MHz with water flows carrying microplastic particles of different materials and sizes served to investigate the dynamic capabilities of the measurement method. The impedance spectra (stationary measurements) or the measured impedances (dynamic measurements) were then evaluated by specific SVMs. The classification task consisted of distinguishing different plastic materials and particle sizes. In the stationary case, the application of the SVM resulted in assignment accuracies of over 98 %. In the dynamic case, the classification accuracies exceeded 91 % for the mere classification of particle sizes and 85 % for the classification of plastic particles by size and material.
- 18 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (5) , 4863-4872
Approaches to Detect Microplastics in Water Using Electrical Impedance Measurements and Support Vector Machines
We propose electrical impedance spectroscopy enhanced by machine learning, in particular support vector machines, as a non-invasive, in-situ method for detecting microplastics in water and as an alternative to slow, expensive laboratory measurements. The primary measurand is the complex-valued electrical impedance of a water-filled measuring cell. We carried out stationary measurements on numerous water samples contaminated with different plastic concentrations in a cylindrical measuring cell and in the frequency range from 20 Hz to 2 MHz. The effects of various influence quantities, such as the concentration of organic material (1.0 %, 3.0 %, 5.0 %) or the salinity of water (0.5 %, 1.0 %, 3.5 %), were also investigated. Measurements at 2 MHz with water flows carrying microplastic particles of different materials and sizes served to investigate the dynamic capabilities of the measurement method. The impedance spectra (stationary measurements) or the measured impedances (dynamic measurements) were then evaluated by specific SVMs. The classification task consisted of distinguishing different plastic materials and particle sizes. In the stationary case, the application of the SVM resulted in assignment accuracies of over 98 %. In the dynamic case, the classification accuracies exceeded 91 % for the mere classification of particle sizes and 85 % for the classification of plastic particles by size and material.
- Open Access
- 11 October 2022
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 11 (2) , 287-298
In situ monitoring of used-sand regeneration in foundries by impedance spectroscopy
This work deals with the impedimetric monitoring of used-sand regeneration in the foundry industry. During the regeneration of used sand, a quartz sand similar to new sand is produced from already used molding and core sand, which especially serves to produce new cores. We explore whether the regeneration progress can be assessed in situ based on measured impedance spectra and their features. The impedances of plate capacitors filled with different typical used-sand mixtures, consisting of quartz sand, coal dust, and bentonite, were repeatedly measured in a frequency range from 500 Hz to 1 MHz. The reproducibility of the measurements proved to be sufficient for practical applications. The mean impedances were plotted in Nyquist diagrams. From these plots, systematic impedance–composition correlations could be determined for two of the three component systems. Conclusions about the regeneration state could be drawn from the impedance curves by introducing various features. These were the median, the mean, and the standard deviation of the frequency-dependent resistance and reactance. With these indicators, it was then possible to establish one-to-one relations between the material composition of the molding materials and the impedance measurement. In field measurements on regenerated used sands, this observation was confirmed, and the regeneration progress was observed on the basis of the impedimetrically determined characteristic data.
- 11 October 2022
- Published by Copernicus GmbH in Journal of Sensors and Sensor Systems
- Vol. 11 (2) , 287-298
Open AccessIn situ monitoring of used-sand regeneration in foundries by impedance spectroscopy
This work deals with the impedimetric monitoring of used-sand regeneration in the foundry industry. During the regeneration of used sand, a quartz sand similar to new sand is produced from already used molding and core sand, which especially serves to produce new cores. We explore whether the regeneration progress can be assessed in situ based on measured impedance spectra and their features. The impedances of plate capacitors filled with different typical used-sand mixtures, consisting of quartz sand, coal dust, and bentonite, were repeatedly measured in a frequency range from 500 Hz to 1 MHz. The reproducibility of the measurements proved to be sufficient for practical applications. The mean impedances were plotted in Nyquist diagrams. From these plots, systematic impedance–composition correlations could be determined for two of the three component systems. Conclusions about the regeneration state could be drawn from the impedance curves by introducing various features. These were the median, the mean, and the standard deviation of the frequency-dependent resistance and reactance. With these indicators, it was then possible to establish one-to-one relations between the material composition of the molding materials and the impedance measurement. In field measurements on regenerated used sands, this observation was confirmed, and the regeneration progress was observed on the basis of the impedimetrically determined characteristic data.
- 25 March 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (5) , 303-310
Monte Carlo method for the reduction of measurement errors in the material parameter estimation with cavities
The quantitative determination of material parameter distributions in resonant cavities is a relatively new method for the real-time monitoring of chemical processes. For this purpose, electromagnetic resonances of the cavity resonator are used as input data for the reverse calculation (inversion). However, the reverse calculation algorithm is sensitive to disturbances of the input data, which produces measurement errors and tends to diverge, which leads to no measurement result at all. In this work a correction algorithm based on the Monte Carlo method is presented which ensures a convergent behavior of the reverse calculation algorithm.
- 25 March 2021
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 88 (5) , 303-310
Monte Carlo method for the reduction of measurement errors in the material parameter estimation with cavities
The quantitative determination of material parameter distributions in resonant cavities is a relatively new method for the real-time monitoring of chemical processes. For this purpose, electromagnetic resonances of the cavity resonator are used as input data for the reverse calculation (inversion). However, the reverse calculation algorithm is sensitive to disturbances of the input data, which produces measurement errors and tends to diverge, which leads to no measurement result at all. In this work a correction algorithm based on the Monte Carlo method is presented which ensures a convergent behavior of the reverse calculation algorithm.