G. Martinez-Lema
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
G. Martinez-Lema has a total of 250 co-authors. Here are the top co-authors by number of shared publications:
- Lior Arazi
Ben-Gurion University of the Negev
7 shared publications N. Byrnes
University of Texas at Arlington
7 shared publicationsA. Para
Fermi National Accelerator Laboratory
6 shared publications- J. Renner
Universidade de Santiago de Compostela
6 shared publications - Josè Juan Gomez Cadenas
Donostia International Physics Center
6 shared publications - A. Castillo
Donostia International Physics Center, BERC Basque Excellence Research Centre
5 shared publications
Latest Publications
- Open Access
- 19 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11)
ITACA revisited: ion tracking apparatus with CMOS ASICs
High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ half-lives in excess of $$10^{28}$$ yr.- 19 November 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (11)
Open AccessITACA revisited: ion tracking apparatus with CMOS ASICs
High-pressure xenon gas TPCs with electroluminescent amplification provide detailed topological reconstruction of charged-particle trajectories, offering a distinctive two-electron signature for neutrinoless double beta decay ( $$\beta \beta 0\nu $$ ) searches. We recently proposed ITACA, a detector concept that images both the electron track and the corresponding ion track. While electrons drift rapidly to the anode for standard EL imaging, the positive ions drift slowly to the cathode with millimetre-scale diffusion, allowing time to determine the event energy and barycenter and to position a movable ion detector at the projected arrival point of the ion cloud. We present a conceptual design of the ITACA detector, addressing key feasibility questions. First, we define the detector geometry and operating parameters for a 1-tonne-scale instrument at 15 bar, including a modular tiled electroluminescent structure. Second, we present the conceptual design of the Magnetically Actuated Rotor System (MARS), the mechanism that positions the ion sensor at any coordinate below the cathode, and show that the expected movement time is fast enough to retain $$\sim 93\%$$ of the drift volume for ion detection, while not significantly perturbing the gas on the scales of the ion drift. Third, we propose using a Topmetal CMOS ASIC-based ion detector, enabling real-time, 3D imaging of the ion track without the need for offline laser scanning. Finally, we estimate the sensitivity of the proposed apparatus, showing that enhanced topological discrimination from the ion track, combined with an ultra-low background design, allows exploration of $$\beta \beta 0\nu $$ half-lives in excess of $$10^{28}$$ yr. - Open Access
- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Demonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ .- 10 September 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (9) , 1057
Open AccessDemonstration of sub-percent energy resolution in the NEXT-100 detector
NEXT-100 is a high-pressure xenon time projection chamber with electroluminescent amplification, designed to operate with up to $$\sim $$ 70.5 kg at 13.5 bar. It is the most recent detector developed by the NEXT collaboration to search for the neutrinoless double-beta decay ( $$\beta \beta 0\nu $$ ) of $$ ^{136}\mathrm Xe$$ . The NEXT gas TPC technology offers the best energy resolution near the Q-value of the decay ( $$Q_{\beta \beta }$$ = 2458 keV) among xenon detectors, which is set by design to be <1% FWHM. We report here the high-energy calibration of the detector using a $$ ^{228}\textrm{Th}$$ source, demonstrating excellent linear response and an energy resolution of $$(0.90 \pm 0.02)\%$$ FWHM at the $$^{208}$$ Tl photopeak (2615 keV). This performance extrapolates to a resolution at the double-beta decay end-point of $$R(Q_{\beta \beta }) = (0.93 \pm 0.02)\%$$ FWHM, confirming the detector’s capability for precision energy measurement in the search for $$\beta \beta 0\nu $$ . - Open Access
- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
First results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target.- 1 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessFirst results of the NEXT-100 detector using 83mKr decays
The NEXT collaboration is investigating the double beta decay of $$ ^{136}\mathrm Xe$$ using high-pressure gas electroluminescent time projection chambers, which provide excellent energy resolution together with a robust topological signature. Operating at the Laboratorio Subterráneo de Canfranc (LSC) and building on the success of the NEXT-White detector, the NEXT-100 apparatus began commissioning in May 2024 and started operation with xenon at a pressure of 4 bar in October 2024. We report here the first results obtained with NEXT-100 using low-energy calibration data from $$^{83\text {m}}\textrm{Kr}$$ decays, which allow mapping of the detector response in the active volume and monitoring of its stability over time. After homogenizing the light response, we achieve an energy resolution of 4.37% FWHM at 41.5 keV for $$^{83\text {m}}\textrm{Kr}$$ point-like energy deposits contained in a radius of 425 mm. In a fiducial region representing the operating conditions of NEXT-100 at 10 bar we obtain an improved energy resolution of 4.16% FWHM. These results are in good agreement with that obtained in NEXT-White, and an $$E^{-1/2}$$ extrapolation to $$Q_{\beta \beta }$$ yields an energy resolution close to 0.5% FWHM, well below the 1% FWHM design target. - Top Cited PapersOpen Access
- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
The NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.- 5 February 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (2) , 114
Top Cited PapersOpen AccessThe NEXT-100 Detector
The NEXT collaboration is dedicated to the study of double beta decays of $$^{136}$$ Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution ( $$\le 1\%$$ FWHM at the $$Q_{\beta \beta }$$ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at $$\sim $$ 4 bar and drift fields of $$74\hbox { V cm}^{-1}$$ and $$118\hbox { V cm}^{-1}$$ , respectively. Alpha decays from the $$^{222}$$ Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget. - Open Access
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10041
Electroluminescence and charge multiplication in liquid xenon with a VCC-like Microstrip Plate
We report on the first observation of electroluminescence and charge amplification with a Virtual Cathode Chamber (VCC) microstrips plate immersed in liquid xenon. Both were observed in an intense non-uniform electric field in the vicinity of 2-μm narrow anode strips deposited, with a 2 mm pitch, on a semiconductive glass substrate (S8900), with a cathode film on its backside. An initial light yield of ∼ 460 VUV photons per drifting electron was measured, which degraded within tens of minutes stabilizing at (27.0 ± 3.1) photons per electron. The electroluminescence was accompanied by electron multiplication with an estimated charge gain ≲ 5. Further investigations are necessary to understand and mitigate the light yield degradation phenomenon. We expect other substrate materials, including VUV-transparent ones, to provide large stable photon yields, compatible with our model predictions. The VCC configuration has demonstrated great potential in single-phase noble-liquid detectors, particularly for dark-matter searches, neutrino physics and other fields.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , P10041
Open AccessElectroluminescence and charge multiplication in liquid xenon with a VCC-like Microstrip Plate
We report on the first observation of electroluminescence and charge amplification with a Virtual Cathode Chamber (VCC) microstrips plate immersed in liquid xenon. Both were observed in an intense non-uniform electric field in the vicinity of 2-μm narrow anode strips deposited, with a 2 mm pitch, on a semiconductive glass substrate (S8900), with a cathode film on its backside. An initial light yield of ∼ 460 VUV photons per drifting electron was measured, which degraded within tens of minutes stabilizing at (27.0 ± 3.1) photons per electron. The electroluminescence was accompanied by electron multiplication with an estimated charge gain ≲ 5. Further investigations are necessary to understand and mitigate the light yield degradation phenomenon. We expect other substrate materials, including VUV-transparent ones, to provide large stable photon yields, compatible with our model predictions. The VCC configuration has demonstrated great potential in single-phase noble-liquid detectors, particularly for dark-matter searches, neutrino physics and other fields.
- Open Access
- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Performance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and .- 28 August 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (8) , 1-9
Open AccessPerformance of an optical TPC Geant4 simulation with opticks GPU-accelerated photon propagation
We investigate the performance of , a 7.5 GPU-accelerated photon propagation tool compared with a single-threaded simulation. We compare the simulations using an improved model of the gaseous time projection chamber. Performance results suggest that improves simulation speeds by between $$58.47\pm {0.02}$$ and $$181.39\pm {0.28}$$ times relative to a CPU-only simulation and these results vary between different types of GPU and CPU. A detailed comparison shows that the number of detected photons, along with their times and wavelengths, are in good agreement between and . - Open Access
- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Reconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected.- 15 July 2025
- Published by Springer Nature in Journal of High Energy Physics
- Vol. 2025 (7) , 1-22
Open AccessReconstructing neutrinoless double beta decay event kinematics in a xenon gas detector with vertex tagging
A bstract: If neutrinoless double beta decay is discovered, the next natural step would be understanding the lepton number violating physics responsible for it. Several alternatives exist beyond the exchange of light neutrinos. Some of these mechanisms can be distinguished by measuring phase-space observables, namely the opening angle cos θ among the two decay electrons, and the electron energy spectra, T 1 and T 2 . In this work, we study the statistical accuracy and precision in measuring these kinematic observables in a future xenon gas detector with the added capability to precisely locate the decay vertex. For realistic detector conditions (a gas pressure of 10 bar and spatial resolution of 4 mm), we find that the average $$ \overline{\cos\ \theta } $$ and $$ \overline{T_1} $$ values can be reconstructed with a precision of 0.19 and 110 keV, respectively, assuming that only 10 neutrinoless double beta decay events are detected. - Open Access
- 3 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
First studies on cascaded dual-phase liquid hole-multipliers in xenon
- 3 March 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1075
Open AccessFirst studies on cascaded dual-phase liquid hole-multipliers in xenon
- Open Access
- 1 February 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (02) , P02037
First observation of liquid xenon electroluminescence with a MicroStrip Plate
We report on the first observation of electroluminescence amplification with a MicroStrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-μm narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yield in the liquid reached a value of (35.5 ± 2.6) VUV photons/electron. We propose ways of enhancing this response with more appropriate microstructures towards their potential incorporation as sensing elements in single-phase noble-liquid detectors.
- 1 February 2024
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 19 (02) , P02037
Open AccessFirst observation of liquid xenon electroluminescence with a MicroStrip Plate
We report on the first observation of electroluminescence amplification with a MicroStrip Plate immersed in liquid xenon. The electroluminescence of the liquid, induced by alpha-particles, was observed in an intense non-uniform electric field in the vicinity of 8-μm narrow anode strips interlaced with wider cathode ones, deposited on the same side of a glass substrate. The electroluminescence yield in the liquid reached a value of (35.5 ± 2.6) VUV photons/electron. We propose ways of enhancing this response with more appropriate microstructures towards their potential incorporation as sensing elements in single-phase noble-liquid detectors.
- 1 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1061
SiPM-based fast-neutron resonance radiography camera part I- evaluation of intrinsic factors influencing image quality in a thick neutron converter
- 1 February 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1061
SiPM-based fast-neutron resonance radiography camera part I- evaluation of intrinsic factors influencing image quality in a thick neutron converter