ASAlina Scholz

Alina Scholz

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alina Scholz has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring

    by Gabriel Ramos‐Llordén, Daniel J. Park, John E. Kirsch, Alina Scholz, Boris Keil, Chiara Maffei, Hong‐Hsi Lee, Berkin Bilgic, Brian L. Edlow, Choukri Mekkaoui, et al.

    Purpose: To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current‐induced artifacts incurred by strong diffusion‐sensitizing gradients up to 300 mT/m used in high b‐value diffusion‐weighted (DW) EPI.Methods: A dynamic field camera equipped with 16 1H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi‐shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring‐based image reconstruction was demonstrated on high‐gradient strength, submillimeter resolution whole‐brain ex vivo diffusion MRI. A 3D multi‐shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera.Results: Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k‐space trajectory. During the readout, phase modulations between odd and even EPI echoes become non‐static and diffusion encoding direction‐dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator‐ and structured low‐rank‐based methods or MUSE followed by image‐based distortion correction with the FSL tool “eddy.”Conclusion: Strong eddy current artifacts characteristic of high‐gradient strength DW‐EPI can be well corrected with dynamic field monitoring‐based image reconstruction.


  • Open Access

    A patient‐friendly 16‐channel transmit/64‐channel receive coil array for combined head–neck MRI at 7 Tesla

    by Markus W. May, Sam‐Luca J. D. Hansen, Mirsad Mahmutovic, Alina Scholz, Nicolas Kutscha, Bastien Guerin, Jason P. Stockmann, Robert L. Barry, Ehsan Kazemivalipour, Rene Gumbrecht, et al.

    Purpose: To extend the coverage of brain coil arrays to the neck and cervical–spine region to enable combined head and neck imaging at 7 Tesla (T) ultra‐high field MRI.Methods: The coil array structures of a 64‐channel receive coil and a 16‐channel transmit coil were merged into one anatomically shaped close‐fitting housing. Transmit characteristics were evaluated in a B1+‐field mapping study and an electromagnetic model. Receive SNR and the encoding capability for accelerated imaging were evaluated and compared with a commercially available 7 T brain array coil. The performance of the head–neck array coil was demonstrated in human volunteers using high‐resolution accelerated imaging.Results: In the brain, the SNR matches the commercially available 32‐channel brain array and showed improvements in accelerated imaging capabilities. More importantly, the constructed coil array improved the SNR in the face area, neck area, and cervical spine by a factor of 1.5, 3.4, and 5.2, respectively, in regions not covered by 32‐channel brain arrays at 7 T. The interelement coupling of the 16‐channel transmit coil ranged from −14 to −44 dB (mean = −19 dB, adjacent elements <−18 dB). The parallel 16‐channel transmit coil greatly facilitates B1+ field shaping required for large FOV neuroimaging at 7 T.Conclusion: This new head–neck array coil is the first demonstration of a device of this nature used for combined full‐brain, head–neck, and cervical‐spine imaging at 7 T. The array coil is well suited to provide large FOV images, which potentially improves ultrahigh field neuroimaging applications for clinical settings.


  • Open Access

    High-fidelity, high-spatial-resolution diffusion MRI of the ex-vivo whole human brain on the 3T Connectom scanner using structured low-rank EPI ghost correction

    by Gabriel Ramos-Llordén, Rodrigo A. Lobos, Tae Hyung Kim, Qiyuan Tian, Thomas Witzel, Hong-Hsi Lee, Alina Scholz, Boris Keil, Anastasia Yendiki, Berkin Bilgiç, et al.

    Diffusion MRI (dMRI) of whole, intact, fixed postmortem human brain at high spatial resolution serves as key bridging technology for 3D mapping of structural connectivity and tissue microstructure at the mesoscopic scale. Ex vivo dMRI offers superior spatial resolution compared to in vivo dMRI but comes with its own technical challenges due to the significantly reduced T2 relaxation times and decreased diffusivity incurred by tissue fixation. The altered physical properties of fixed tissue necessitate the use of alternative acquisition strategies to preserve SNR and achieve sufficient diffusion weighting. Multi-shot or segmented 3D echo planar imaging (EPI) sequences have been used to shorten echo times (TEs) with reduced distortions from field inhomogeneity and eddy currents on small-bore MR scanners and have been adopted for high b-value dMRI of ex vivo whole human brain specimens. The advent of stronger gradients on human MRI scanners has led to improved image quality and a wider range of diffusion-encoding parameters for dMRI but at the cost of more severe eddy currents that result in spatial and temporal variations in the background magnetic field, which cannot be corrected for using standard vendor-provided ghost correction solutions. In this work, we show that conventional ghost correction techniques based on navigators and linear phase correction may be insufficient for EPI sequences using strong diffusion-sensitizing gradients in ex vivo dMRI experiments, resulting in orientationally biased dMRI estimates. This previously unreported problem is a critical roadblock in any effort to leverage scanners with ultra-high gradients for high-precision mapping of human neuroanatomy at the mesoscopic scale. We propose an advanced reconstruction method based on structured low-rank matrix modeling that reduces the ghosting substantially. We show that this method leads to more accurate and reliable dMRI metrics, as exemplified by diffusion tensor imaging and high angular diffusion imaging analyses in distributed neuroanatomical areas of fixed whole human brain specimens. Our findings advocate for the use of advanced reconstruction techniques for recovering unbiased metrics from ex vivo dMRI acquisitions and represent a crucial step toward making full use of strong diffusion-encoding gradients for neuroscientific studies seeking to study brain structure at multiple spatial scales.

  • Open Access

    A size‐adaptive 32‐channel array coil for awake infant neuroimaging at 3 Tesla MRI

    by Anpreet Ghotra, Heather L. Kosakowski, Atsushi Takahashi, Robin Etzel, Markus W. May, Alina Scholz, Andreas Jansen, Lawrence L. Wald, Nancy Kanwisher, Rebecca Saxe, et al.

    Purpose: Functional magnetic resonance imaging (fMRI) during infancy poses challenges due to practical, methodological, and analytical considerations. The aim of this study was to implement a hardware‐related approach to increase subject compliance for fMRI involving awake infants. To accomplish this, we designed, constructed, and evaluated an adaptive 32‐channel array coil.Methods: To allow imaging with a close‐fitting head array coil for infants aged 1‐18 months, an adjustable head coil concept was developed. The coil setup facilitates a half‐seated scanning position to improve the infant’s overall scan compliance. Earmuff compartments are integrated directly into the coil housing to enable the usage of sound protection without losing a snug fit of the coil around the infant’s head. The constructed array coil was evaluated from phantom data using bench‐level metrics, signal‐to‐noise ratio (SNR) performances, and accelerated imaging capabilities for both in‐plane and simultaneous multislice (SMS) reconstruction methodologies. Furthermore, preliminary fMRI data were acquired to evaluate the in vivo coil performance.Results: Phantom data showed a 2.7‐fold SNR increase on average when compared with a commercially available 32‐channel head coil. At the center and periphery regions of the infant head phantom, the SNR gains were measured to be 1.25‐fold and 3‐fold, respectively. The infant coil further showed favorable encoding capabilities for undersampled k‐space reconstruction methods and SMS techniques.Conclusions: An infant‐friendly head coil array was developed to improve sensitivity, spatial resolution, accelerated encoding, motion insensitivity, and subject tolerance in pediatric MRI. The adaptive 32‐channel array coil is well‐suited for fMRI acquisitions in awake infants.


  • Open Access

    A 48-Channel Receive Array Coil for Mesoscopic Diffusion-Weighted MRI of Human ex vivo Brain Imaging on the 3T Connectome Scanner

    by Alina Scholz, Robin Etzel, Markus W May, Mirsad Mahmutovic, Qiyuan Tian, Gabriel Ramos-Llordén, Berkin Bilgiç, Thomas Witzel, Jason P Stockmann, Choukri Mekkaoui, et al.

    In vivo diffusion-weighted magnetic resonance imaging is limited in signal-to-noise-ratio (SNR) and acquisition time, which constrains spatial resolution to the macroscale regime. Ex vivo imaging, which allows for arbitrarily long scan times, is critical for exploring human brain structure in the mesoscale regime without loss of SNR. Standard head array coils designed for patients are sub-optimal for imaging ex vivo whole brain specimens. The goal of this work was to design and construct a 48-channel ex vivo whole brain array coil for high-resolution and high b -value diffusion-weighted imaging on a 3T Connectome scanner. The coil was validated with bench measurements and characterized by imaging metrics on an agar brain phantom and an ex vivo human brain sample. The two-segment coil former was constructed for a close fit to a whole human brain, with small receive elements distributed over the entire brain. Imaging tests including SNR and G-factor maps were compared to a 64-channel head coil designed for in vivo use. There was a 2.9-fold increase in SNR in the peripheral cortex and a 1.3-fold gain in the center when compared to the 64-ch head coil. The 48-channel ex vivo whole brain coil also decreases noise amplification in highly parallel imaging, allowing acceleration factors of approximately one unit higher for a given noise amplification level. The acquired diffusion-weighted images in a whole ex vivo brain specimen demonstrate the applicability of the developed coil for high-resolution and high b -value diffusion-weighted ex vivo brain MRI studies.