GRGabriel Ramos-Llordén

Gabriel Ramos-Llordén

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabriel Ramos-Llordén has a total of 147 co-authors. Here are the top co-authors by number of shared publications:

  • Susie Y. Huang

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, MA, United States

    8 shared publications
  • Hong-Hsi Lee

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology Massachusetts General Hospital Charlestown Massachusetts USA

    7 shared publications
  • Anastasia Yendiki

    Athinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Charlestown, USA

    6 shared publications
  • Boris Keil

    Institute of Medical Physics and Radiation Protection, Mittelhessen University of Applied Sciences Giessen Germany

    5 shared publications
  • Thomas Witzel

    Q Bio Inc., San Carlos, USA

    5 shared publications
  • Boris Keil

    Institute of Medical Physics and Radiation Protection, TH-Mittelhessen University of Applied Sciences, Giessen, Germany

    4 shared publications

Latest Publications

  • Open Access

    Publisher Correction: Ultra-high gradient connectomics and microstructure MRI scanner for imaging of human brain circuits across scales

    by Gabriel Ramos-Llordén, Hong-Hsi Lee, Mathias Davids, Peter Dietz, Andreas Krug, John E. Kirsch, Mirsad Mahmutovic, Alina Müller, Yixin Ma, Hansol Lee, et al.


  • Top Cited Papers
    Open Access

    Ultra-high gradient connectomics and microstructure MRI scanner for imaging of human brain circuits across scales

    by Gabriel Ramos-Llordén, Hong-Hsi Lee, Mathias Davids, Peter Dietz, Andreas Krug, John E. Kirsch, Mirsad Mahmutovic, Alina Müller, Yixin Ma, Hansol Lee, et al.

    Defining the connectome, the complete matrix of structural connections between the nervous system nodes, is a challenge for human systems neuroscience due to the range of scales that must be bridged. Here we report the design of the Connectome 2.0 human magnetic resonance imaging (MRI) scanner to perform connectomics at the mesoscopic and microscopic scales with strong gradients for in vivo human imaging. We construct a 3-layer head-only gradient coil optimized to minimize peripheral nerve stimulation while achieving a gradient strength of 500 mT m −1 and a slew rate of 600 T m −1 s −1 , corresponding to a 5-fold greater gradient performance than state-of-the-art research gradient systems, including the original Connectome (Connectome 1.0) scanner. We find that gains in sensitivity of up to two times were achieved by integrating a 72-channel in vivo head coil and a 64-channel ex vivo whole-brain radiofrequency coil with built-in field monitoring for data fidelity. We demonstrate mapping of fine white matter pathways and inferences of cellular and axonal size and morphology approaching the single-micron level, with at least a 30% sensitivity improvement compared with Connectome 1.0.


  • Open Access

    High‐density MRI coil arrays with integrated field monitoring systems for human connectome mapping

    by Mirsad Mahmutovic, Manisha Shrestha, Gabriel Ramos‐Llordén, Dongsuk Sung, Luke J. Edwards, Ying Chu, Paul I. Dubovan, Alina Müller, Sam‐Luca J.D. Hansen, Anpreet Ghotra, et al.

    Purpose: To develop and test two high‐density MRI coil arrays with integrated field monitoring systems for enhanced diffusion imaging with strong diffusion‐sensitizing gradients.Methods: Two multichannel head coils were constructed for first‐ and second‐generation 3T Connectome MRI scanners, incorporating 64 and 72 receive channels, respectively. The array coils were evaluated using RF bench‐level metrics, including quality factor, tuning, matching, and coupling measurements. Imaging performance was comprehensively assessed through metrics such as SNR, efficiency, and inter‐channel noise correlations, and compared with and without field camera integration. Parallel imaging capability was evaluated using geometry (g)‐factors. The field camera performance was characterized by quantifying phase errors and field probe FID lifetimes. In vivo DWI acquisitions with high ‐values were performed to evaluate the system's ability to correct higher‐order field perturbations.Results: The developed arrays demonstrated up to 1.4‐fold higher SNR and superior g‐factor performance when compared to a commercially available 32‐channel head coil. Integration of the field camera was achieved without compromising the performance of either system. In vivo imaging with concurrent field monitoring enabled accurate spatiotemporal field corrections, significantly reducing geometric distortions, blurring, and ghosting in high ‐value DWI.Conclusion: The integration of high‐density MRI arrays with field monitoring systems facilitated the capture and correction of spatiotemporal field perturbations during strong gradient activity, substantially enhancing image quality and diffusion parameter mapping quality. These advancements provide a robust platform for exploring the structural intricacies of the human connectome.


  • Open Access

    Strong gradients, cool performance: A 64‐channel array coil with concurrent field monitoring and thermal control for ex vivo diffusion‐weighted brain imaging using the 3T connectome 2.0 MRI scanner

    by Alina Müller, Mirsad Mahmutovic, Mona Alem, Gabriel Ramos‐Llordén, Dongsuk Sung, Manisha Shrestha, Sam‐Luca J.D. Hansen, Chaimaa Chemlali, Anpreet Ghotra, Jason Stockmann, et al.

    Purpose: High‐resolution ex vivo diffusion‐weighted imaging (dMRI) with high ‐values presents significant challenges, including low signal‐to‐noise ratio (SNR), magnetic field perturbations, and temperature‐related measurement shifts. This work introduces a hardware‐based solution to address these limitations in human ex vivo brain imaging.Methods: A customized anatomically conformal 64‐channel receive array coil with a dedicated Tx birdcage coil was developed for 3T diffusion‐weighted imaging of whole human ex vivo brain specimens. Field monitoring capabilities were integrated to correct spatiotemporal field perturbations caused by gradient‐induced eddy currents. Temperature stability throughout extended acquisition periods was achieved through an integrated stabilization system. Coil performance was validated through comprehensive measurement of SNR, g‐factor maps, field camera free induction decays (FIDs), temperature, mean diffusivity, and fractional anisotropy across multiple diffusion‐weighted scans.Results: The system demonstrated 73% higher SNR compared with a 72‐channel in vivo head coil. Integration of the field camera maintained its FID quality without SNR penalties or significant receive coil coupling effects. Temperature stabilization improved the reliability of quantitative diffusion‐weighted measurements by eliminating measurement drift during a 13‐hour acquisition, where mean diffusivity and mean kurtosis would have increased by 22% and decreased by 19%, respectively.Conclusion: We describe an integrated hardware approach for addressing higher order field perturbations, thermal instability, and SNR challenges in human ex vivo whole brain dMRI under high‐diffusion sensitizing gradient conditions. This approach combines an anatomically optimized multichannel receive array, concurrent field monitoring, and active temperature stabilization. Enhanced image quality and improved reliability of quantitative MR imaging were demonstrated with this comprehensive hardware solution.


  • The effects of axonal beading and undulation on axonal diameter estimation from diffusion MRI: Insights from simulations in human axons segmented from three‐dimensional electron microscopy

    by Hong‐Hsi Lee, Qiyuan Tian, Maxina Sheft, Ricardo Coronado‐Leija, Gabriel Ramos‐Llorden, Ali Abdollahzadeh, Els Fieremans, Dmitry S. Novikov, Susie Y. Huang

    The increasing availability of high‐performance gradient systems in human MRI scanners has generated great interest in diffusion microstructural imaging applications such as axonal diameter mapping. Practically, sensitivity to axon diameter in diffusion MRI is attained at strong diffusion weightings , where the deviation from the expected scaling in white matter yields a finite transverse diffusivity, which is then translated into an axon diameter estimate. While axons are usually modeled as perfectly straight, impermeable cylinders, local variations in diameter (caliber variation or beading) and direction (undulation) are known to influence axonal diameter estimates and have been observed in microscopy data of human axons. In this study, we performed Monte Carlo simulations of diffusion in axons reconstructed from three‐dimensional electron microscopy of a human temporal lobe specimen using simulated sequence parameters matched to the maximal gradient strength of the next‐generation Connectome 2.0 human MRI scanner ( 500 mT/m). We show that axon diameter estimation is accurate for nonbeaded, nonundulating fibers; however, in fibers with caliber variations and undulations, the axon diameter is heavily underestimated due to caliber variations, and this effect overshadows the known overestimation of the axon diameter due to undulations. This unexpected underestimation may originate from variations in the coarse‐grained axial diffusivity due to caliber variations. Given that increased axonal beading and undulations have been observed in pathological tissues, such as traumatic brain injury and ischemia, the interpretation of axon diameter alterations in pathology may be significantly confounded.


  • Contributors

    by Santiago Aja-Fernández, Carlos Alberola-López, Andre Altmann, Sophia Bano, Vincent Christlein, Shan Cong, Sailesh Conjeti, Tim Cootes, Ariel H. Curiale, Marleen de Bruijne, et al.

  • Eddy current‐induced artifact correction in high b‐value ex vivo human brain diffusion MRI with dynamic field monitoring

    by Gabriel Ramos‐Llordén, Daniel J. Park, John E. Kirsch, Alina Scholz, Boris Keil, Chiara Maffei, Hong‐Hsi Lee, Berkin Bilgic, Brian L. Edlow, Choukri Mekkaoui, et al.

    Purpose: To investigate whether spatiotemporal magnetic field monitoring can correct pronounced eddy current‐induced artifacts incurred by strong diffusion‐sensitizing gradients up to 300 mT/m used in high b‐value diffusion‐weighted (DW) EPI.Methods: A dynamic field camera equipped with 16 1H NMR field probes was first used to characterize field perturbations caused by residual eddy currents from diffusion gradients waveforms in a 3D multi‐shot EPI sequence on a 3T Connectom scanner for different gradient strengths (up to 300 mT/m), diffusion directions, and shots. The efficacy of dynamic field monitoring‐based image reconstruction was demonstrated on high‐gradient strength, submillimeter resolution whole‐brain ex vivo diffusion MRI. A 3D multi‐shot image reconstruction framework was developed that incorporated the nonlinear phase evolution measured with the dynamic field camera.Results: Phase perturbations in the readout induced by residual eddy currents from strong diffusion gradients are highly nonlinear in space and time, vary among diffusion directions, and interfere significantly with the image encoding gradients, changing the k‐space trajectory. During the readout, phase modulations between odd and even EPI echoes become non‐static and diffusion encoding direction‐dependent. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting reduction approaches such as navigator‐ and structured low‐rank‐based methods or MUSE followed by image‐based distortion correction with the FSL tool “eddy.”Conclusion: Strong eddy current artifacts characteristic of high‐gradient strength DW‐EPI can be well corrected with dynamic field monitoring‐based image reconstruction.


  • Open Access

    The influence of axonal beading and undulation on axonal diameter mapping

    by Hong-Hsi Lee, Qiyuan Tian, Maxina Sheft, Ricardo Coronado-Leija, Gabriel Ramos-Llorden, Ali Abdollahzadeh, Els Fieremans, Dmitry S. Novikov, Susie Y. Huang

    We consider the effect of non-cylindrical axonal shape on axonal diameter mapping with diffusion MRI. Practical sensitivity to axon diameter is attained at strong diffusion weightings b , where the deviation from the scaling yields the finite transverse diffusivity, which is then translated into axon diameter. While axons are usually modeled as perfectly straight, impermeable cylinders, the local variations in diameter (caliber variation or beading) and direction (undulation) have been observed in microscopy data of human axons. Here we quantify the influence of cellular-level features such as caliber variation and undulation on axon diameter estimation. For that, we simulate the diffusion MRI signal in realistic axons segmented from 3-dimensional electron microscopy of a human brain sample. We then create artificial fibers with the same features and tune the amplitude of their caliber variations and undulations. Numerical simulations of diffusion in fibers with such tunable features show that caliber variations and undulations result in under- and over-estimation of axon diameters, correspondingly; this bias can be as large as 100%. Given that increased axonal beading and undulations have been observed in pathological tissues, such as traumatic brain injury and ischemia, the interpretation of axon diameter alterations in pathology may be significantly confounded.


  • Open Access

    Eddy current-induced artifacts correction in high gradient strength diffusion MRI with dynamic field monitoring: demonstration in ex vivo human brain imaging

    by Gabriel Ramos-Llordén, Daniel Park, John E. Kirsch, Alina Scholz, Boris Keil, Chiara Maffei, Hong-Hsi Lee, Berkin Bilgiç, Brian L. Edlow, Choukri Mekkaoui, et al.

    Purpose To demonstrate the advantages of spatiotemporal magnetic field monitoring to correct eddy current-induced artifacts (ghosting and geometric distortions) in high gradient strength diffusion MRI (dMRI). Methods A dynamic field camera with 16 NMR field probes was used to characterize eddy current fields induced from diffusion gradients for different gradients strengths (up to 300 mT/m), diffusion directions, and shots in a 3D multi-shot EPI sequence on a 3T Connectom scanner. The efficacy of dynamic field monitoring-based image reconstruction was demonstrated on high-resolution whole brain ex vivo dMRI. A 3D multi-shot image reconstruction framework was informed with the actual nonlinear phase evolution measured with the dynamic field camera, thereby accounting for high-order eddy currents fields on top of the image encoding gradients in the image formation model. Results Eddy current fields from diffusion gradients at high gradient strength in a 3T Connectom scanner are highly nonlinear in space and time, inducing high-order spatial phase modulations between odd/even echoes and shots that are not static during the readout. Superior reduction of ghosting and geometric distortion was achieved with dynamic field monitoring compared to ghosting approaches such as navigator- and structured low-rank-based methods or MUSE, followed by image-based distortion correction with eddy. Improved dMRI analysis is demonstrated with diffusion tensor imaging and high-angular resolution diffusion imaging. Conclusion Strong eddy current artifacts characteristic of high gradient strength dMRI can be well corrected with dynamic field monitoring-based image reconstruction, unlike the two-step approach consisting of ghosting correction followed by geometric distortion reduction with eddy.

  • High‐fidelity, high‐spatial‐resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra‐high gradient strength with structured low‐rank echo‐planar imaging ghost correction

    by Gabriel Ramos‐Llordén, Rodrigo A. Lobos, Tae Hyung Kim, Qiyuan Tian, Thomas Witzel, Hong‐Hsi Lee, Alina Scholz, Boris Keil, Anastasia Yendiki, Berkin Bilgiç, et al.

    Diffusion magnetic resonance imaging (dMRI) of whole ex vivo human brain specimens enables three‐dimensional (3D) mapping of structural connectivity at the mesoscopic scale, providing detailed evaluation of fiber architecture and tissue microstructure at a spatial resolution that is difficult to access in vivo. To account for the short T2 and low diffusivity of fixed tissue, ex vivo dMRI is often acquired using strong diffusion‐sensitizing gradients and multishot/segmented 3D echo‐planar imaging (EPI) sequences to achieve high spatial resolution. However, the combination of strong diffusion‐sensitizing gradients and multishot/segmented EPI readout can result in pronounced ghosting artifacts incurred by nonlinear spatiotemporal variations in the magnetic field produced by eddy currents. Such ghosting artifacts cannot be corrected with conventional correction solutions and pose a significant roadblock to leveraging human MRI scanners with ultrahigh gradients for ex vivo whole‐brain dMRI. Here, we show that ghosting‐correction approaches that correct for either polarity‐related ghosting or shot‐to‐shot variations in a separate manner are suboptimal for 3D multishot diffusion‐weighted EPI experiments in fixed human brain specimens using strong diffusion‐sensitizing gradients on the 3‐T Connectom MRI scanner, resulting in orientationally biased dMRI estimates. We apply a recently developed advanced k‐space reconstruction method based on structured low‐rank matrix (SLM) modeling that handles both polarity‐related ghosting and shot‐to‐shot variation simultaneously, to mitigate artifacts in high‐angular resolution multishot dMRI data acquired in several fixed human brain specimens at 0.7–0.8‐mm isotropic spatial resolution using b‐values up to 10,000 s/mm2 and gradient strengths up to 280 mT/m. We demonstrate the improved mapping of diffusion tensor imaging and fiber orientation distribution functions in key neuroanatomical areas distributed across the whole brain using SLM‐based EPI ghost correction compared with alternative techniques.