Vera A. Shavokshina
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vera A. Shavokshina has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Arkady A. Karyakin
Chemistry Faculty of M.V. Lomonosov Moscow State University, 119991, Moscow, Russia
4 shared publications Arkady A. Karyakin
3 shared publications- Egor Andreev
M.V. Lomonosov Moscow State University Leninskie Gory, 1/3
3 shared publications Egor A. Andreev
2 shared publicationsMaria A. Komkova
2 shared publications- Maria A. Komkova
Chemistry Department, M.V. Lomonosov Moscow State University, Leninskie Gory, 1/3, Moscow 119991, Russia
2 shared publications
Latest Publications
- 12 November 2026
- Published by Elsevier in Electrochimica Acta
Ultramicroelectrodes diffusion peculiarities accessed through square-wave voltammetry
- 12 November 2026
- Published by Elsevier in Electrochimica Acta
Ultramicroelectrodes diffusion peculiarities accessed through square-wave voltammetry
- Open Access
- 10 October 2026
- Published by Elsevier in SSRN Electronic Journal
Ultramicroelectrodes Diffusion Peculiarities Accessed Through Square-Wave Voltammetry
Despite analytical solutions of diffusion equations for planar and spherical cases predict for current the Cottrell-type reciprocal square root time decay, the generally accepted apparent solution for disk electrodes involves higher exponents of time. Redox probe square-wave voltammetry on both graphite and gold (ultra)microelectrodes displays linear dependence of net peak currents on square root of frequency even at the lower end of the latter. Moreover, net peak current has been found to be proportional to the ultramicroelectrode area. Hence, faster than Cottrell-type time decay has not been confirmed experimentally for small disk electrodes.
- 10 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessUltramicroelectrodes Diffusion Peculiarities Accessed Through Square-Wave Voltammetry
Despite analytical solutions of diffusion equations for planar and spherical cases predict for current the Cottrell-type reciprocal square root time decay, the generally accepted apparent solution for disk electrodes involves higher exponents of time. Redox probe square-wave voltammetry on both graphite and gold (ultra)microelectrodes displays linear dependence of net peak currents on square root of frequency even at the lower end of the latter. Moreover, net peak current has been found to be proportional to the ultramicroelectrode area. Hence, faster than Cottrell-type time decay has not been confirmed experimentally for small disk electrodes.
- 21 June 2024
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 79 (6) , 740-748
Amperometric Signal Generation by Self-Doped Polyanilines for Ion-Selective Electrodes
Flow injection amperometry provides an opportunity to avoid common drawbacks of classical potentiometry for solid-contact ion-selective electrodes. The current is generated by solid-contact in course of the polymer chain recharging in response to an excess of cations or anions in the polymer film. Cations cause cathodic peaks on the chronoamperogram, while anions result in anodic peaks. For polyaniline with negatively charged substituents, a response to cations is observed, whereas the presence of uncharged ones results in anion detection. Moreover, in the case of the protonated –SO3H group, this compensating current is an order of magnitude lower than that for the deprotonated one. For electroactive self-doped polyanilines, the maximal amperometric signal is achieved at the working potential within the electroactivity range. The proposed constant potential amperometric approach was validated by the successful analysis of human serum with a Na+-selective electrode based on polyaniline.
- 21 June 2024
- Published by Pleiades Publishing Ltd in Journal of Analytical Chemistry
- Vol. 79 (6) , 740-748
Amperometric Signal Generation by Self-Doped Polyanilines for Ion-Selective Electrodes
Flow injection amperometry provides an opportunity to avoid common drawbacks of classical potentiometry for solid-contact ion-selective electrodes. The current is generated by solid-contact in course of the polymer chain recharging in response to an excess of cations or anions in the polymer film. Cations cause cathodic peaks on the chronoamperogram, while anions result in anodic peaks. For polyaniline with negatively charged substituents, a response to cations is observed, whereas the presence of uncharged ones results in anion detection. Moreover, in the case of the protonated –SO3H group, this compensating current is an order of magnitude lower than that for the deprotonated one. For electroactive self-doped polyanilines, the maximal amperometric signal is achieved at the working potential within the electroactivity range. The proposed constant potential amperometric approach was validated by the successful analysis of human serum with a Na+-selective electrode based on polyaniline.
- Open Access
- 25 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 4
Amperometric Ion-Selective Electrodes Based on Prussian Blue Nanoparticles
We report amperometric solid-contact potassium-selective electrodes based on catalytically synthesized Prussian Blue nanoparticles. Both the films and nanoparticles were able to generate an amperometric response in the flow-injection mode under a constant potential. However, the nanoparticles provided a higher sensitivity than the films. Moreover, the intrinsic permeability of Prussian Blue for potassium ions allowed for selective detection of potassium in comparison to sodium even without an ion-selective membrane. The results of electrochemical impedance spectroscopy were used to manage the sensitivity by controlling the charge transfer resistance for ion-selective membranes of different density. By performing measurements in Bis-Tris as a carrier buffer containing no interfering cations, an additional increase in selectivity was enabled. A record selectivity coefficient logK Na+/K+ of −2.7 for the amperometric flow-injection mode was achieved. The obtained results indicate the prospects for analysis of biological fluids as the Na+/K+ ratio is approximately 20–40.
- 25 September 2023
- Published by MDPI AG in Engineering Proceedings
- Vol. 48 (1) , 4
Open AccessAmperometric Ion-Selective Electrodes Based on Prussian Blue Nanoparticles
We report amperometric solid-contact potassium-selective electrodes based on catalytically synthesized Prussian Blue nanoparticles. Both the films and nanoparticles were able to generate an amperometric response in the flow-injection mode under a constant potential. However, the nanoparticles provided a higher sensitivity than the films. Moreover, the intrinsic permeability of Prussian Blue for potassium ions allowed for selective detection of potassium in comparison to sodium even without an ion-selective membrane. The results of electrochemical impedance spectroscopy were used to manage the sensitivity by controlling the charge transfer resistance for ion-selective membranes of different density. By performing measurements in Bis-Tris as a carrier buffer containing no interfering cations, an additional increase in selectivity was enabled. A record selectivity coefficient logK Na+/K+ of −2.7 for the amperometric flow-injection mode was achieved. The obtained results indicate the prospects for analysis of biological fluids as the Na+/K+ ratio is approximately 20–40.
- 25 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 3 (3) , 1518-1524
Improved Electroactivity of Redox Probes onto Electropolymerized Azidomethyl-PEDOT: Enabling Click Chemistry for Advanced (Bio)Sensors
- 25 February 2021
- Published by American Chemical Society (ACS) in ACS Applied Polymer Materials
- Vol. 3 (3) , 1518-1524
Improved Electroactivity of Redox Probes onto Electropolymerized Azidomethyl-PEDOT: Enabling Click Chemistry for Advanced (Bio)Sensors
- 12 December 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (4) , 602-606
Reagentless Microsensor Based on Conducting Poly(3‐aminophenylboronic Acid) for Rapid Detection of Microorganisms in Aerosol
We report on microsensor for direct detection of microorganisms in aerosol. Microsensor is based on interdigitated ultramicroelectrodes modified with electropolymerized 3‐aminophenylboronic acid (3‐APBA). Appearance of Penicillium chrysogenum in aerosol as well as further increase of its concentration lead to poly(3‐APBA) conductivity increase found by impedance spectroscopy. According to Raman spectroscopy data, the presence of microorganism affects polymer conductivity similarly to binding of glucose to polymer which results in self‐doping phenomenon. The elaborated detection technique is 100 times faster comparing to agar plate cultivation: it requires less than 20 minutes for analysis. Dynamic range of microsensor includes the upper limit for non‐contaminated air in Russian hygienic standard (500 colony‐forming units per cubic meter). The first reported reagentless detection of Penicillium chrysogenum in aerosol by conductivity increase reveals a prospect for creation of a promising alternative to conventional techniques for detection of microorganisms.
- 12 December 2017
- Published by Wiley in Electroanalysis
- Vol. 30 (4) , 602-606
Reagentless Microsensor Based on Conducting Poly(3‐aminophenylboronic Acid) for Rapid Detection of Microorganisms in Aerosol
We report on microsensor for direct detection of microorganisms in aerosol. Microsensor is based on interdigitated ultramicroelectrodes modified with electropolymerized 3‐aminophenylboronic acid (3‐APBA). Appearance of Penicillium chrysogenum in aerosol as well as further increase of its concentration lead to poly(3‐APBA) conductivity increase found by impedance spectroscopy. According to Raman spectroscopy data, the presence of microorganism affects polymer conductivity similarly to binding of glucose to polymer which results in self‐doping phenomenon. The elaborated detection technique is 100 times faster comparing to agar plate cultivation: it requires less than 20 minutes for analysis. Dynamic range of microsensor includes the upper limit for non‐contaminated air in Russian hygienic standard (500 colony‐forming units per cubic meter). The first reported reagentless detection of Penicillium chrysogenum in aerosol by conductivity increase reveals a prospect for creation of a promising alternative to conventional techniques for detection of microorganisms.