Dave Lowe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Dave Lowe has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
- Graham Machin
National Physical Laboratory (NPL), Hampton Road, Teddington, TW11 0LW, UK
7 shared publications - Gavin Sutton
Department of Thermal and Radiometric Metrology, National Physical Laboratory, Teddington, United Kingdom
4 shared publications - Andrew Douglas William Todd
National Research Council Canada
2 shared publications F Bourson
2 shared publicationsG. Machin
National Physical Laboratory, Teddington UK
2 shared publications- H. C. McEvoy
National Physical Laboratory
2 shared publications
Latest Publications
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 100002
Low uncertainty thermodynamic temperature above the silver point using relative primary radiometry
The mise-en-pratique for the definition of the kelvin has given the possibility of relative primary thermometry with uncertainties competitive with the ITS-90 a The mise-en-pratique for the definition of the kelvin has given the possibility of relative primary thermometry with uncertainties competitive with the ITS-90 a
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 100002
Open AccessLow uncertainty thermodynamic temperature above the silver point using relative primary radiometry
The mise-en-pratique for the definition of the kelvin has given the possibility of relative primary thermometry with uncertainties competitive with the ITS-90 a The mise-en-pratique for the definition of the kelvin has given the possibility of relative primary thermometry with uncertainties competitive with the ITS-90 a
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 070006
High-temperature fixed-point furnace uncertainties
High-temperature fixed-points with specified temperature values for phase transition temperatures and their uncertainties can be used to establish a temperature High-temperature fixed-points with specified temperature values for phase transition temperatures and their uncertainties can be used to establish a temperature
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3230 (1) , 070006
Open AccessHigh-temperature fixed-point furnace uncertainties
High-temperature fixed-points with specified temperature values for phase transition temperatures and their uncertainties can be used to establish a temperature High-temperature fixed-points with specified temperature values for phase transition temperatures and their uncertainties can be used to establish a temperature
- Open Access
- 9 February 2022
- Published by IOP Publishing in Measurement Science and Technology
Electromagnetic immune phosphor-tipped fibre-optic thermometers
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by electro-magnetic sources. For this application, phosphor based temperature sensors with fibre-optic connection have been made following two different approaches – phosphor decay time changes and phosphor emission spectral changes – and tested by bombardment with high energy electrons and by measurements in large magnetic fields. Both sets of tests showed good immunity to exposure, and with magnetic field tests significantly better than a thermocouple. Phosphor thermometry therefore has potential to retain traceability in situations where conventional sensors might fail.
- 9 February 2022
- Published by IOP Publishing in Measurement Science and Technology
Open AccessElectromagnetic immune phosphor-tipped fibre-optic thermometers
Calibration traceability can be broken where there are significant, unquantified uncertainties. Thermometry in harsh environments using electrical sensors, such as thermocouples or resistance thermometers, can be unpredictably affected by electro-magnetic sources. For this application, phosphor based temperature sensors with fibre-optic connection have been made following two different approaches – phosphor decay time changes and phosphor emission spectral changes – and tested by bombardment with high energy electrons and by measurements in large magnetic fields. Both sets of tests showed good immunity to exposure, and with magnetic field tests significantly better than a thermocouple. Phosphor thermometry therefore has potential to retain traceability in situations where conventional sensors might fail.
- Open Access
- 29 January 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (4) , 1-16
Toward Gamma Ray Immune Fibre-Optic Phosphor Thermometry for Nuclear Decommissioning
Temperature measurement of stored nuclear waste is important for long-term monitoring. Conventional sensors can degrade in ionizing radiation from induced transmutations and their frequent replacement is inconvenient. A thermometer based on suitable phosphors can overcome some problems, but the optical signal needs to be transmitted through an optical fibre and processed remotely away from the dangerous area. This requires that the optical fibre itself be suitably resistant to radiation-induced damage. Here, we report transmission measurements through a type of hollow-core fibre based on anti-resonance and with transmission windows at wavelengths suitable for use with the thermographic phosphor magnesium fluorogermanate whilst subjected to gamma radiation. Its performance is compared to commercially available standard fibres (single mode and radiation hard fibres) at dose rates equivalent to decades of use in a storage facility. Transmission was unchanged for the anti-resonant fibre at the phosphor emission wavelength and it was successfully incorporated into a fibre thermometer that worked from $${20}\,^{\circ }\hbox {C}$$ to $$200\,^{\circ }\hbox {C}$$ . Performance at the phosphor excitation wavelength needs to be improved by modification to the hollow-core fibre design, but we show that a hybrid of single mode and anti-resonant fibres can already be made into a thermometer with suitable gamma immunity.- 29 January 2022
- Published by Springer Nature in International Journal of Thermophysics
- Vol. 43 (4) , 1-16
Open AccessToward Gamma Ray Immune Fibre-Optic Phosphor Thermometry for Nuclear Decommissioning
Temperature measurement of stored nuclear waste is important for long-term monitoring. Conventional sensors can degrade in ionizing radiation from induced transmutations and their frequent replacement is inconvenient. A thermometer based on suitable phosphors can overcome some problems, but the optical signal needs to be transmitted through an optical fibre and processed remotely away from the dangerous area. This requires that the optical fibre itself be suitably resistant to radiation-induced damage. Here, we report transmission measurements through a type of hollow-core fibre based on anti-resonance and with transmission windows at wavelengths suitable for use with the thermographic phosphor magnesium fluorogermanate whilst subjected to gamma radiation. Its performance is compared to commercially available standard fibres (single mode and radiation hard fibres) at dose rates equivalent to decades of use in a storage facility. Transmission was unchanged for the anti-resonant fibre at the phosphor emission wavelength and it was successfully incorporated into a fibre thermometer that worked from $${20}\,^{\circ }\hbox {C}$$ to $$200\,^{\circ }\hbox {C}$$ . Performance at the phosphor excitation wavelength needs to be improved by modification to the hollow-core fibre design, but we show that a hybrid of single mode and anti-resonant fibres can already be made into a thermometer with suitable gamma immunity. - 13 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035007
On the uncertainties in the realization of the kelvin based on thermodynamic temperatures of high-temperature fixed-point cells
In July 2016 the Consultative Committee for Thermometry’s Non-Contact Thermometry Working Group formed a task group to compile a complete list of uncertainties for high-temperature fixed points, categorize them as well specified or not, and recommend areas of future research. We describe herein two paths to realizing T by indirect primary radiometry using high-temperature fixed-point blackbody cells: one in which published values for the metal–carbon eutectic material transition temperatures are used and the other where a set of cells has their transition temperatures determined directly. The uncertainty components that need to be considered for each path are given together with typically achievable values and how well those values are known. This work concentrates on Co–C, Pt–C and Re–C.
- 13 April 2021
- Published by IOP Publishing in Metrologia
- Vol. 58 (3) , 035007
On the uncertainties in the realization of the kelvin based on thermodynamic temperatures of high-temperature fixed-point cells
In July 2016 the Consultative Committee for Thermometry’s Non-Contact Thermometry Working Group formed a task group to compile a complete list of uncertainties for high-temperature fixed points, categorize them as well specified or not, and recommend areas of future research. We describe herein two paths to realizing T by indirect primary radiometry using high-temperature fixed-point blackbody cells: one in which published values for the metal–carbon eutectic material transition temperatures are used and the other where a set of cells has their transition temperatures determined directly. The uncertainty components that need to be considered for each path are given together with typically achievable values and how well those values are known. This work concentrates on Co–C, Pt–C and Re–C.
- Open Access
- 12 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 094004
Design, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
Measurement traceability, in which there is a documented chain of calibration links from a measurement back to a primary realisation of a unit, is vital for achieving the smallest uncertainty in metrology. A sensor that can provide a traceable link in harsh environments may be advantageous even if its uncertainty is larger than that of typical calibrated devices. A phosphor-based thermometer that has optical rather than electrical connections has been built and then calibrated in terms of the International Temperature Scale of 1990. Its standard uncertainty ranges from 0.5 °C at 0 °C to 2 °C at 650 °C. While this uncertainty cannot match what is possible with thermocouples or resistance thermometers, the optical basis of the sensor means it can be used in situations where electrical connections are precluded.
- 12 March 2021
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 32 (9) , 094004
Open AccessDesign, construction and traceable calibration of a phosphor-based fibre-optic thermometer from 0 °C to 650 °C
Measurement traceability, in which there is a documented chain of calibration links from a measurement back to a primary realisation of a unit, is vital for achieving the smallest uncertainty in metrology. A sensor that can provide a traceable link in harsh environments may be advantageous even if its uncertainty is larger than that of typical calibrated devices. A phosphor-based thermometer that has optical rather than electrical connections has been built and then calibrated in terms of the International Temperature Scale of 1990. Its standard uncertainty ranges from 0.5 °C at 0 °C to 2 °C at 650 °C. While this uncertainty cannot match what is possible with thermocouples or resistance thermometers, the optical basis of the sensor means it can be used in situations where electrical connections are precluded.
- Open Access
- 15 December 2020
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 5 (4) , 31
Towards an Ultra-High-Speed Combustion Pyrometer
Measuring reliably the correct temperature of a sooty flame in an internal combustion engine is important to optimise its efficiency; however, conventional contact thermometers, such as thermocouples, are not adequate in this context, due to drift, temperature limitation (≤2100 K) and slow response time (~10 ms). In this paper, we report on the progress towards the development of a novel ultra-high-speed combustion pyrometer, based on collection of thermal radiation via an optical fibre, traceably calibrated to the International Temperature Scale of 1990 (ITS-90) over the temperature range T = (1073–2873) K, with residuals <1%, and capable of measuring at a sampling rate of 250 kHz.
- 15 December 2020
- Published by MDPI AG in International Journal of Turbomachinery, Propulsion and Power
- Vol. 5 (4) , 31
Open AccessTowards an Ultra-High-Speed Combustion Pyrometer
Measuring reliably the correct temperature of a sooty flame in an internal combustion engine is important to optimise its efficiency; however, conventional contact thermometers, such as thermocouples, are not adequate in this context, due to drift, temperature limitation (≤2100 K) and slow response time (~10 ms). In this paper, we report on the progress towards the development of a novel ultra-high-speed combustion pyrometer, based on collection of thermal radiation via an optical fibre, traceably calibrated to the International Temperature Scale of 1990 (ITS-90) over the temperature range T = (1073–2873) K, with residuals <1%, and capable of measuring at a sampling rate of 250 kHz.
- Open Access
- 23 September 2019
- Published by EDP Sciences
- p. 24002
Improving fixed-point cell realization by modifying furnace heater shape
Recent changes to the SI make it possible to set up a primary temperature scale using established values for certain high-temperature fixed points. As the furnace used with the fixed points can itself have a significant impact on measurements, improving furnace temperature uniformity can help to reduce uncertainties. A thermal model was used to redesign heaters to reduce temperature gradients where the fixed-point cell is positioned in the furnace. A heater optimised for 1325 °C was compared to the standard one with a cobalt carbon high-temperature fixed-point cells, where the cell was installed in the middle, and also moved 10 mm to each end. The modified heater showed reduced melting range, improved plateau run-off and less sensitivity to fixed-point cell position. The improvements will reduce the uncertainties associated with this type of furnace.
- 23 September 2019
- Published by EDP Sciences
- p. 24002
Open AccessImproving fixed-point cell realization by modifying furnace heater shape
Recent changes to the SI make it possible to set up a primary temperature scale using established values for certain high-temperature fixed points. As the furnace used with the fixed points can itself have a significant impact on measurements, improving furnace temperature uniformity can help to reduce uncertainties. A thermal model was used to redesign heaters to reduce temperature gradients where the fixed-point cell is positioned in the furnace. A heater optimised for 1325 °C was compared to the standard one with a cobalt carbon high-temperature fixed-point cells, where the cell was installed in the middle, and also moved 10 mm to each end. The modified heater showed reduced melting range, improved plateau run-off and less sensitivity to fixed-point cell position. The improvements will reduce the uncertainties associated with this type of furnace.