Harish K. Sharma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Harish K. Sharma has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
R. K. Nema
Department of Electrical Engineering Maulana Azad National Institute of Technology Bhopal India
1 shared publication- Rajesh Kumar Nema
Department of Electrical Engineering, Maulana Azad National Institute of Technology, Bhopal, India
1 shared publication Savita Nema
Department of Electrical Engineering Maulana Azad National Institute of Technology Bhopal India
1 shared publication- Savita Nema
Department of Electrical Engineering, MANIT, Bhopal, India
1 shared publication
Latest Publications
- 1 March 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (4) , e12850
Normograms preparation and interpretation for 400/ 800 kV class of converter transformers/reactors with and without oil using sweep frequency response analysis ( SFRA )
Converter transformers of voltage class 400 kV and above mainly cater to HVDC transmission and have a different structure of core and winding than generator transformer of same voltage class. Preinstallation diagnosis/inspection of these large transformers is of great importance due to possible mechanical movement during transportation in the active part. Sweep frequency response analysis (SFRA) is generally used to detect such mechanical movement by comparing site test results with the record of baseline measurement conducted at works and archived in the form of normograms. The meticulous documentation of test results is therefore of significant importance as a tool for future diagnosis. Present literature mostly encompasses 400 kV class of generator transformer or autotransformers, while the normograms (SFRA test results) of specialized 800 kV/400 kV class of converter transformer and interpretation thereof are yet to be reported. The SFRA test conducted at works and the results so archived therefore serve as baseline measurement for all future diagnosis. The present paper discusses theory, procedure, and results of SFRA tests conducted at works on 800 kV/400 kV class of converter transformers and on 400 kV reactors under oil‐filled and oil‐drained out conditions. The paper also discusses some statistical indicators used to interpret SFRA results, the interpretation otherwise is based on the experience of experts/interpreter. In addition, the proposed work will save lead time and cost saving by adopting SFRA test without oil filled condition as user can peep into transformer assembly by observing its SFRA traces and comparing it with normograms for any deviation before installing at site.
- 1 March 2021
- Published by Hindawi Limited in International Transactions on Electrical Energy Systems
- Vol. 31 (4) , e12850
Normograms preparation and interpretation for 400/ 800 kV class of converter transformers/reactors with and without oil using sweep frequency response analysis ( SFRA )
Converter transformers of voltage class 400 kV and above mainly cater to HVDC transmission and have a different structure of core and winding than generator transformer of same voltage class. Preinstallation diagnosis/inspection of these large transformers is of great importance due to possible mechanical movement during transportation in the active part. Sweep frequency response analysis (SFRA) is generally used to detect such mechanical movement by comparing site test results with the record of baseline measurement conducted at works and archived in the form of normograms. The meticulous documentation of test results is therefore of significant importance as a tool for future diagnosis. Present literature mostly encompasses 400 kV class of generator transformer or autotransformers, while the normograms (SFRA test results) of specialized 800 kV/400 kV class of converter transformer and interpretation thereof are yet to be reported. The SFRA test conducted at works and the results so archived therefore serve as baseline measurement for all future diagnosis. The present paper discusses theory, procedure, and results of SFRA tests conducted at works on 800 kV/400 kV class of converter transformers and on 400 kV reactors under oil‐filled and oil‐drained out conditions. The paper also discusses some statistical indicators used to interpret SFRA results, the interpretation otherwise is based on the experience of experts/interpreter. In addition, the proposed work will save lead time and cost saving by adopting SFRA test without oil filled condition as user can peep into transformer assembly by observing its SFRA traces and comparing it with normograms for any deviation before installing at site.
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (1) , 17-23
IMPROVING DIELECTRIC DISSIPATION FACTOR OF 420 kV CLASS OIL-SF6 RIP BUSHINGS AT SITE
The resin-impregnated paper (RIP) bushing offers many benefits over the resin-bonded paper (RBP) or oil-impregnated paper (OIP) bushings. RIP bushing that is upgraded with a new generation of epoxy resin-impregnated crepe paper insulation, which is hygroscopic in nature, is highly cured, dried, and processed during the production. The challenging job is to ensure the dried conditions during the long lead time of transportation, storage, erection, testing, and commissioning, though they are preserved and transported in a very protective environment. During the pre-installation check at various commissioning sites, the Tan delta value of RIP bushing must conform to the International Council on Large Electric Systems (CIGRE) standard, else it had to be replaced with a new healthy bushing, causing unnecessary delay in the project schedule and increase in the project cost. As on date, no such on-site Tand improvement procedure is reported/available in the literature that could improve Tand of the RIP bushing with the detrimental value. A new on-site dry-out procedure is evolved and discussed in this paper to improve Tand of the RIP bushing.'
- 1 January 2021
- Published by ACTA Press in International Journal of Power and Energy Systems
- Vol. 41 (1) , 17-23
IMPROVING DIELECTRIC DISSIPATION FACTOR OF 420 kV CLASS OIL-SF6 RIP BUSHINGS AT SITE
The resin-impregnated paper (RIP) bushing offers many benefits over the resin-bonded paper (RBP) or oil-impregnated paper (OIP) bushings. RIP bushing that is upgraded with a new generation of epoxy resin-impregnated crepe paper insulation, which is hygroscopic in nature, is highly cured, dried, and processed during the production. The challenging job is to ensure the dried conditions during the long lead time of transportation, storage, erection, testing, and commissioning, though they are preserved and transported in a very protective environment. During the pre-installation check at various commissioning sites, the Tan delta value of RIP bushing must conform to the International Council on Large Electric Systems (CIGRE) standard, else it had to be replaced with a new healthy bushing, causing unnecessary delay in the project schedule and increase in the project cost. As on date, no such on-site Tand improvement procedure is reported/available in the literature that could improve Tand of the RIP bushing with the detrimental value. A new on-site dry-out procedure is evolved and discussed in this paper to improve Tand of the RIP bushing.'