Clayton Henrique Rocha
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Clayton Henrique Rocha has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Alessandra Giannella Samelli
Universidade de São Paulo, Brasil
11 shared publications - Carla Gentile Matas
Universidade de São Paulo, Faculdade de Medicina, Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional, São Paulo SP, Brazil
4 shared publications Renata Rodrigues Moreira
Serviço de Audiologia, Hospital Universitário da Universidade de São Paulo (HU-USP), São Paulo, SP, Brazil
4 shared publications- Beatriz Peixoto Perini
Universidade de São Paulo, Brazil
2 shared publications - Camila Maia Rabelo
I Universidade de São Paulo. Faculdade de Medicina. Departamento de Fisioterapia, Fonoaudiologia e Terapia Ocupacional. São Paulo, SP, Brasil
2 shared publications - Giselle Carvalho Said
Universidade de São Paulo, Brazil
2 shared publications
Latest Publications
- Open Access
- 1 January 2026
- Published by Georg Thieme Verlag KG in International Archives of Otorhinolaryngology
- Vol. 30 (01) , 001-006
Assessment of Two Types of Headphones Used in a Tablet-Based Automated Hearing Screening Method in Different Noise Conditions
To compare the performance of two types of supra-aural headphones in both silence and noise in automated hearing screening in adults via tablet computers. Basic audiological assessments and audiometry screenings via tablet were conducted in silence and noise in 35 participants. The hearing screening application assesses frequencies of 1, 2, and 4 kHz (20 dBHL) and 0.5 kHz (30 dBHL) in each ear separately. Two different headphones were tested: TDH 39 (Telephonics Corporation) and Sennheiser HD 280 PRO (Sennheiser) (with passive noise cancellation)—in silence, white noise, and cafeteria noise, emitted in a free field. The screening results were compared with the gold standard (audiometry). The results of the 35 participants with Sennheiser HD 280 PRO were compatible with the gold standard in the 3 situations. With TDH 39, the results of 33 individuals in silence and 34 in white noise were compatible with the gold standard. Both headphones, in automated screening in silence and noise, had 100% sensitivity, more than 93% specificity, and more than 94% accuracy. Both headphones performed well in the tablet automated hearing screening in the three situations. The HD 280 PRO performed better in silence and noise regarding specificity and accuracy. In cafeteria noise, there was no difference between the two headphones.
- 1 January 2026
- Published by Georg Thieme Verlag KG in International Archives of Otorhinolaryngology
- Vol. 30 (01) , 001-006
Open AccessAssessment of Two Types of Headphones Used in a Tablet-Based Automated Hearing Screening Method in Different Noise Conditions
To compare the performance of two types of supra-aural headphones in both silence and noise in automated hearing screening in adults via tablet computers. Basic audiological assessments and audiometry screenings via tablet were conducted in silence and noise in 35 participants. The hearing screening application assesses frequencies of 1, 2, and 4 kHz (20 dBHL) and 0.5 kHz (30 dBHL) in each ear separately. Two different headphones were tested: TDH 39 (Telephonics Corporation) and Sennheiser HD 280 PRO (Sennheiser) (with passive noise cancellation)—in silence, white noise, and cafeteria noise, emitted in a free field. The screening results were compared with the gold standard (audiometry). The results of the 35 participants with Sennheiser HD 280 PRO were compatible with the gold standard in the 3 situations. With TDH 39, the results of 33 individuals in silence and 34 in white noise were compatible with the gold standard. Both headphones, in automated screening in silence and noise, had 100% sensitivity, more than 93% specificity, and more than 94% accuracy. Both headphones performed well in the tablet automated hearing screening in the three situations. The HD 280 PRO performed better in silence and noise regarding specificity and accuracy. In cafeteria noise, there was no difference between the two headphones.
- Open Access
- 16 December 2025
- Published by Mattioli1885 in La Medicina del Lavoro
- Vol. 116 (6) , 17196
Steady-State Auditory Evoked Potentials in Workers Exposed to Occupational Noise
Background: The present study aims to investigate neural synchrony, as measured by Auditory Steady State Response (ASSR), in individuals with normal hearing who are exposed and not exposed to occupational noise, thereby providing insights into hidden hearing loss within the central auditory nervous system, and justifying the importance of exploring auditory neural function in populations at risk. Methods: A cross-sectional study involved 30 noise-exposed individuals in the Study Group and 30 unexposed individuals in the Control Group, all paired by an average age of 35 years. The following procedures were performed on all individuals: clinical and occupational history, meatoscopy, immitanciometry, pure tone audiometry, speech audiometry, and ASSR (40Hz). We analyzed the audiometric hearing thresholds at frequencies of 1 kHz and 4 kHz, the electrophysiological thresholds estimated by ASSR, and the comparison of the differences between them: the thresholds estimated by ASSR and the audiometry thresholds. The data were analyzed using both descriptive and inferential statistics. P-values ≤ 0.05 were considered significant. Results: When comparing hearing thresholds at 1 kHz and 4 kHz between groups, we found significant differences, with the SG showing higher hearing thresholds than the CG bilaterally. No significant differences were seen in the electrophysiological thresholds estimated by ASSR, nor in the comparison between the ASSR-estimated threshold and the psychoacoustic hearing threshold groups. Conclusions: The results of this study suggest that workers exposed to occupational noise did not show detectable changes in neural synchrony in the midbrain, thalamus, or primary auditory cortex when compared to individuals without occupational noise exposure.
- 16 December 2025
- Published by Mattioli1885 in La Medicina del Lavoro
- Vol. 116 (6) , 17196
Open AccessSteady-State Auditory Evoked Potentials in Workers Exposed to Occupational Noise
Background: The present study aims to investigate neural synchrony, as measured by Auditory Steady State Response (ASSR), in individuals with normal hearing who are exposed and not exposed to occupational noise, thereby providing insights into hidden hearing loss within the central auditory nervous system, and justifying the importance of exploring auditory neural function in populations at risk. Methods: A cross-sectional study involved 30 noise-exposed individuals in the Study Group and 30 unexposed individuals in the Control Group, all paired by an average age of 35 years. The following procedures were performed on all individuals: clinical and occupational history, meatoscopy, immitanciometry, pure tone audiometry, speech audiometry, and ASSR (40Hz). We analyzed the audiometric hearing thresholds at frequencies of 1 kHz and 4 kHz, the electrophysiological thresholds estimated by ASSR, and the comparison of the differences between them: the thresholds estimated by ASSR and the audiometry thresholds. The data were analyzed using both descriptive and inferential statistics. P-values ≤ 0.05 were considered significant. Results: When comparing hearing thresholds at 1 kHz and 4 kHz between groups, we found significant differences, with the SG showing higher hearing thresholds than the CG bilaterally. No significant differences were seen in the electrophysiological thresholds estimated by ASSR, nor in the comparison between the ASSR-estimated threshold and the psychoacoustic hearing threshold groups. Conclusions: The results of this study suggest that workers exposed to occupational noise did not show detectable changes in neural synchrony in the midbrain, thalamus, or primary auditory cortex when compared to individuals without occupational noise exposure.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 26 (4) , e3124
Prontuário virtual para monitoramento audiológico de exposição ao ruído ocupacional
RESUMO Objetivos: desenvolver e implementar um prontuário virtual para gerenciamento das avaliações audiológicas de trabalhadores expostos ao ruído ocupacional de uma universidade. Métodos: foi desenvolvido um sistema informatizado para um serviço de audiologia de um hospital universitário de São Paulo, o Programa de Prontuários Virtuais de Audiologia (PPVA), utilizando o programa Microsoft Access, onde foram incluídas informações funcionais, ocupacionais e audiológicas. Após período de testes, o sistema foi implementado no serviço. Resultados: o PPVA é um sistema personalizado, no qual é possível realizar o cadastro de funcionários, exames audiológicos, histórico clínico e de riscos para perda auditiva induzida por níveis de pressão sonora elevados, além da geração de relatórios indicando a periodicidade para o monitoramento audiológico. Conclusão: o PPVA mostrou-se adequado para atender às demandas do serviço. Sua implementação trouxe melhorias na usabilidade, eficiência e qualidade do registro dos usuários do serviço, sendo também uma potencial ferramenta de vigilância em saúde, indicando que este tipo de ferramenta pode trazer benefícios para um programa de prevenção de perdas auditivas ocupacionais.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 26 (4) , e3124
Open AccessProntuário virtual para monitoramento audiológico de exposição ao ruído ocupacional
RESUMO Objetivos: desenvolver e implementar um prontuário virtual para gerenciamento das avaliações audiológicas de trabalhadores expostos ao ruído ocupacional de uma universidade. Métodos: foi desenvolvido um sistema informatizado para um serviço de audiologia de um hospital universitário de São Paulo, o Programa de Prontuários Virtuais de Audiologia (PPVA), utilizando o programa Microsoft Access, onde foram incluídas informações funcionais, ocupacionais e audiológicas. Após período de testes, o sistema foi implementado no serviço. Resultados: o PPVA é um sistema personalizado, no qual é possível realizar o cadastro de funcionários, exames audiológicos, histórico clínico e de riscos para perda auditiva induzida por níveis de pressão sonora elevados, além da geração de relatórios indicando a periodicidade para o monitoramento audiológico. Conclusão: o PPVA mostrou-se adequado para atender às demandas do serviço. Sua implementação trouxe melhorias na usabilidade, eficiência e qualidade do registro dos usuários do serviço, sendo também uma potencial ferramenta de vigilância em saúde, indicando que este tipo de ferramenta pode trazer benefícios para um programa de prevenção de perdas auditivas ocupacionais.
- Open Access
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 26 (4) , e3124
Electronic medical record for audiological monitoring of occupational noise exposure
Purpose: to develop and implement an electronic medical record for managing audiological assessments of workers exposed to occupational noise at a university. Methods: a computer system - the Electronic Audiology Record Program (PPVA, in Portuguese) - was developed with Microsoft Access for a university hospital’s audiology service, encompassing functional, occupational, and audiological information. After a testing period, the system was implemented in the service. Results: the PPVA is a personalized system that registers employees, audiological exams, clinical history, and risks for hearing loss induced by high sound pressure levels. It also generates reports indicating audiological monitoring frequency. Conclusion: the PPVA proved to meet the service’s needs, adequately. Its implementation improved the usability, efficiency, and quality of the service user records. Hence, it is a potential health surveillance tool, indicating that this type of instrument can benefit occupational hearing loss prevention programs.
- 1 January 2024
- Published by FapUNIFESP (SciELO) in Revista CEFAC
- Vol. 26 (4) , e3124
Open AccessElectronic medical record for audiological monitoring of occupational noise exposure
Purpose: to develop and implement an electronic medical record for managing audiological assessments of workers exposed to occupational noise at a university. Methods: a computer system - the Electronic Audiology Record Program (PPVA, in Portuguese) - was developed with Microsoft Access for a university hospital’s audiology service, encompassing functional, occupational, and audiological information. After a testing period, the system was implemented in the service. Results: the PPVA is a personalized system that registers employees, audiological exams, clinical history, and risks for hearing loss induced by high sound pressure levels. It also generates reports indicating audiological monitoring frequency. Conclusion: the PPVA proved to meet the service’s needs, adequately. Its implementation improved the usability, efficiency, and quality of the service user records. Hence, it is a potential health surveillance tool, indicating that this type of instrument can benefit occupational hearing loss prevention programs.
- Open Access
- 19 June 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (6) , 968
Evaluation of Subtle Auditory Impairments with Multiple Audiological Assessments in Normal Hearing Workers Exposed to Occupational Noise
Recent studies involving guinea pigs have shown that noise can damage the synapses between the inner hair cells and spiral ganglion neurons, even with normal hearing thresholds—which makes it important to investigate this kind of impairment in humans. The aim was to investigate, with multiple audiological assessments, the auditory function of normal hearing workers exposed to occupational noise. Altogether, 60 workers were assessed (30 in the noise-exposure group [NEG], who were exposed to occupational noise, and 30 in the control group [CG], who were not exposed to occupational noise); the workers were matched according to age. The following procedures were used: complete audiological assessment; speech recognition threshold in noise (SRTN); speech in noise (SN) in an acoustic field; gaps-in-noise (GIN); transient evoked otoacoustic emissions (TEOAE) and inhibitory effect of the efferent auditory pathway; auditory brainstem response (ABR); and long-latency auditory evoked potentials (LLAEP). No significant difference was found between the groups in SRTN. In SN, the NEG performed worse than the CG in signal-to-noise ratio (SNR) 0 (p-value 0.023). In GIN, the NEG had a significantly lower percentage of correct answers (p-value 0.042). In TEOAE, the NEG had smaller amplitude values bilaterally (RE p-value 0.048; LE p-value 0.045) and a smaller inhibitory effect of the efferent pathway (p-value 0.009). In ABR, the NEG had greater latencies of wave V (p-value 0.017) and interpeak intervals III-V and I-V in the LE (respective p-values: 0.005 and 0.04). In LLAEP, the NEG had a smaller P3 amplitude bilaterally (RE p-value 0.001; LE p-value 0.002). The NEG performed worse than the CG in most of the assessments, suggesting that the auditory function in individuals exposed to occupational noise is impaired, even with normal audiometric thresholds.
- 19 June 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (6) , 968
Open AccessEvaluation of Subtle Auditory Impairments with Multiple Audiological Assessments in Normal Hearing Workers Exposed to Occupational Noise
Recent studies involving guinea pigs have shown that noise can damage the synapses between the inner hair cells and spiral ganglion neurons, even with normal hearing thresholds—which makes it important to investigate this kind of impairment in humans. The aim was to investigate, with multiple audiological assessments, the auditory function of normal hearing workers exposed to occupational noise. Altogether, 60 workers were assessed (30 in the noise-exposure group [NEG], who were exposed to occupational noise, and 30 in the control group [CG], who were not exposed to occupational noise); the workers were matched according to age. The following procedures were used: complete audiological assessment; speech recognition threshold in noise (SRTN); speech in noise (SN) in an acoustic field; gaps-in-noise (GIN); transient evoked otoacoustic emissions (TEOAE) and inhibitory effect of the efferent auditory pathway; auditory brainstem response (ABR); and long-latency auditory evoked potentials (LLAEP). No significant difference was found between the groups in SRTN. In SN, the NEG performed worse than the CG in signal-to-noise ratio (SNR) 0 (p-value 0.023). In GIN, the NEG had a significantly lower percentage of correct answers (p-value 0.042). In TEOAE, the NEG had smaller amplitude values bilaterally (RE p-value 0.048; LE p-value 0.045) and a smaller inhibitory effect of the efferent pathway (p-value 0.009). In ABR, the NEG had greater latencies of wave V (p-value 0.017) and interpeak intervals III-V and I-V in the LE (respective p-values: 0.005 and 0.04). In LLAEP, the NEG had a smaller P3 amplitude bilaterally (RE p-value 0.001; LE p-value 0.002). The NEG performed worse than the CG in most of the assessments, suggesting that the auditory function in individuals exposed to occupational noise is impaired, even with normal audiometric thresholds.
- Open Access
Effects of Conventional and Musician-Specific Hearing Protection Devices on Speech Intelligibility
(1) Background: To assess and compare speech intelligibility with conventional and universal musician-specific hearing protection devices (HPD); (2) Methods: The sample comprised 15 normal-hearing musicians of both sexes who had been professionals for more than 5 years. They underwent thorough audiological assessment and free-field audiometry to measure the attenuation levels of three HPD models (musician-specific, silicone, and foam devices). The sentence recognition thresholds in quiet (SRTQ) and noise (SRTN) were assessed with the Lists of Sentences in Portuguese. User satisfaction with musician HPD was assessed after 2 months; (3) Results: Conventional HPD had higher pure-tone mean attenuation levels than musician HPD. No statistically significant differences were found in SRTQ and SRTN between the three HPD types. However, the musician HPD had higher mean signal-to-noise ratios and percentages of correct words from sentences presented in noise than the other HPD. The answers also indicated a positive trend toward satisfaction with the musician-specific HPD; (4) Conclusions: Despite the lack of significant differences in speech intelligibility while wearing the three HPD models in either quiet or noise, the musician-specific HPD provided greater musical sound quality. This reinforces the possibility of an effective and adequate use of protection to preserve musicians’ hearing.
Open AccessEffects of Conventional and Musician-Specific Hearing Protection Devices on Speech Intelligibility
(1) Background: To assess and compare speech intelligibility with conventional and universal musician-specific hearing protection devices (HPD); (2) Methods: The sample comprised 15 normal-hearing musicians of both sexes who had been professionals for more than 5 years. They underwent thorough audiological assessment and free-field audiometry to measure the attenuation levels of three HPD models (musician-specific, silicone, and foam devices). The sentence recognition thresholds in quiet (SRTQ) and noise (SRTN) were assessed with the Lists of Sentences in Portuguese. User satisfaction with musician HPD was assessed after 2 months; (3) Results: Conventional HPD had higher pure-tone mean attenuation levels than musician HPD. No statistically significant differences were found in SRTQ and SRTN between the three HPD types. However, the musician HPD had higher mean signal-to-noise ratios and percentages of correct words from sentences presented in noise than the other HPD. The answers also indicated a positive trend toward satisfaction with the musician-specific HPD; (4) Conclusions: Despite the lack of significant differences in speech intelligibility while wearing the three HPD models in either quiet or noise, the musician-specific HPD provided greater musical sound quality. This reinforces the possibility of an effective and adequate use of protection to preserve musicians’ hearing.
- 27 February 2021
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 28 (2) , 1227-1234
Effects of hearing protector devices on speech intelligibility: the importance of individualized assessment
Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, −5, −10 and −15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of −5, −10 and −15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
- 27 February 2021
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 28 (2) , 1227-1234
Effects of hearing protector devices on speech intelligibility: the importance of individualized assessment
Objectives. This study aimed to compare speech intelligibility in noise with and without hearing protection devices (HPDs). Methods. Fifty-one workers were distributed into three groups: noise-induced hearing loss group (NIHLG), normally hearing noise-exposed group (NG) and normally hearing non-exposed to noise group (CG). A free field system was used to emit monosyllables (65, 70 and 75 dB) and pink noise in different signal-to-noise ratios (SNRs) (0, −5, −10 and −15). Results. In situations with HPDs, all groups showed a decrease in the percentage of correct responses with an increase in noise level. The HPD had little effect on speech intelligibility in the NIHLG and NG. Considering the effect caused by the HPD on speech intelligibility, it was observed that the group with the greatest loss was the CG for SNRs of −5, −10 and −15. Conclusion. Although speech intelligibility is influenced by the hearing threshold, the noise level and SNR are crucial for good speech intelligibility, either with or without an HPD. It is highlighted that the NG had worse results when compared with the CG, which may indicate changes in the auditory pathway resulting from continuous noise exposure, even in the absence of changes in the audiometric thresholds.
- 22 June 2020
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 63 (6) , 2016-2026
Personal Audio System: Hearing Symptoms, Habits, and Sound Pressure Levels Measured in Real Ear and a Manikin
Purpose: The aims of this study were to characterize hearing symptoms, habits, and sound pressure levels (SPLs) of personal audio system (PAS) used by young adults; estimate the risk of developing hearing loss and assess whether instructions given to users led to behavioral changes; and propose recommendations for PAS users. Method: A cross-sectional study was performed in 50 subjects with normal hearing. Procedures included questionnaire and measurement of PAS SPLs (real ear and manikin) through the users' own headphones and devices while they listened to four songs. After 1 year, 30 subjects answered questions about their usage habits. For the statistical analysis, one-way analysis of variance, Tukey's post hoc test, Lin and Spearman coefficients, the chi-square test, and logistic regression were used. Results: Most subjects listened to music every day, usually in noisy environments. Sixty percent of the subjects reported hearing symptoms after using a PAS. Substantial variability in the equivalent music listening level (Leq) was noted ( M = 84.7 dBA; min = 65.1 dBA, max = 97.5 dBA). A significant difference was found only in the 4-kHz band when comparing the real-ear and manikin techniques. Based on the Leq, 38% of the individuals exceeded the maximum daily time allowance. Comparison of the subjects according to the maximum allowed daily exposure time revealed a higher number of hearing complaints from people with greater exposure. After 1 year, 43% of the subjects reduced their usage time, and 70% reduced the volume. A volume not exceeding 80% was recommended, and at this volume, the maximum usage time should be 160 min. Conclusions: The habit of listening to music at high intensities on a daily basis seems to cause hearing symptoms, even in individuals with normal hearing. The real-ear and manikin techniques produced similar results. Providing instructions on this topic combined with measuring PAS SPLs may be an appropriate strategy for raising the awareness of people who are at risk. Supplemental Material: https://doi.org/10.23641/asha.12431435
- 22 June 2020
- Published by American Speech Language Hearing Association in Journal of Speech, Language, and Hearing Research
- Vol. 63 (6) , 2016-2026
Personal Audio System: Hearing Symptoms, Habits, and Sound Pressure Levels Measured in Real Ear and a Manikin
Purpose: The aims of this study were to characterize hearing symptoms, habits, and sound pressure levels (SPLs) of personal audio system (PAS) used by young adults; estimate the risk of developing hearing loss and assess whether instructions given to users led to behavioral changes; and propose recommendations for PAS users. Method: A cross-sectional study was performed in 50 subjects with normal hearing. Procedures included questionnaire and measurement of PAS SPLs (real ear and manikin) through the users' own headphones and devices while they listened to four songs. After 1 year, 30 subjects answered questions about their usage habits. For the statistical analysis, one-way analysis of variance, Tukey's post hoc test, Lin and Spearman coefficients, the chi-square test, and logistic regression were used. Results: Most subjects listened to music every day, usually in noisy environments. Sixty percent of the subjects reported hearing symptoms after using a PAS. Substantial variability in the equivalent music listening level (Leq) was noted ( M = 84.7 dBA; min = 65.1 dBA, max = 97.5 dBA). A significant difference was found only in the 4-kHz band when comparing the real-ear and manikin techniques. Based on the Leq, 38% of the individuals exceeded the maximum daily time allowance. Comparison of the subjects according to the maximum allowed daily exposure time revealed a higher number of hearing complaints from people with greater exposure. After 1 year, 43% of the subjects reduced their usage time, and 70% reduced the volume. A volume not exceeding 80% was recommended, and at this volume, the maximum usage time should be 160 min. Conclusions: The habit of listening to music at high intensities on a daily basis seems to cause hearing symptoms, even in individuals with normal hearing. The real-ear and manikin techniques produced similar results. Providing instructions on this topic combined with measuring PAS SPLs may be an appropriate strategy for raising the awareness of people who are at risk. Supplemental Material: https://doi.org/10.23641/asha.12431435
- 20 February 2020
- Published by SAGE Publications in WORK: A Journal of Prevention, Assessment & Rehabilitation
- Vol. 65 (2) , 401-407
Training in the proper use of earplugs: An objective evaluation
BACKGROUND: Discrepancies between attenuation obtained in the laboratory and the field are caused by several factors associated with hearing protection devices (HPDs). The effects of some factors can be minimized with proper training provided to HPD
- 20 February 2020
- Published by SAGE Publications in WORK: A Journal of Prevention, Assessment & Rehabilitation
- Vol. 65 (2) , 401-407
Training in the proper use of earplugs: An objective evaluation
BACKGROUND: Discrepancies between attenuation obtained in the laboratory and the field are caused by several factors associated with hearing protection devices (HPDs). The effects of some factors can be minimized with proper training provided to HPD
- Open Access
- 1 April 2016
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 28 (2) , 99-105
Avaliação do protetor auditivo em situação real de trabalho pelo método field Microphone-in-real-ear
RESUMO Objetivo Avaliar a eficácia da atenuação de um protetor auditivo em uma situação real de trabalho utilizando o método f-Microphone-in-real-ear (f-MIRE). Métodos Participaram 18 indivíduos, de ambos os gêneros (média de idade 47,17±8 anos). No local de trabalho, foi realizada a avaliação do nível pessoal de atenuação do Protetor Auditivo (PA) pelo método Field Microphone-in-Real-Ear (f-MIRE), seguido por orientações sobre a importância do uso do PA, higienização, armazenamento e treinamento para sua colocação efetiva. Resultados As análises mostraram que houve atenuação estatisticamente significante para todos os dados coletados (ruído total, por banda de frequência e dose) quando comparados os níveis de ruído no microfone lapela e no microfone sonda. Na comparação entre os valores de atenuação fornecidos pelo fabricante e os encontrados neste estudo, observou-se valores maiores para o fabricante em todas as bandas de frequência. Não houve diferença para os níveis de ruído nas diferentes atividades e horários avaliados. Conclusão Os achados do presente estudo possibilitaram conhecer o nível pessoal de atenuação do protetor auditivo durante uma situação real de trabalho, que estava dentro dos limites de tolerância. Também foi possível coletar informações sobre o ruído do ambiente em que esses trabalhadores estão expostos, onde observamos situações nas quais esse nível ultrapassava os valores de segurança, sendo assim recomendável o uso do PA. É importante que mais estudos sejam realizados utilizando o método f-MIRE, pois pode ser um aliado para avaliar a eficácia da atenuação do PA no local de trabalho.
- 1 April 2016
- Published by FapUNIFESP (SciELO) in CoDAS
- Vol. 28 (2) , 99-105
Open AccessAvaliação do protetor auditivo em situação real de trabalho pelo método field Microphone-in-real-ear
RESUMO Objetivo Avaliar a eficácia da atenuação de um protetor auditivo em uma situação real de trabalho utilizando o método f-Microphone-in-real-ear (f-MIRE). Métodos Participaram 18 indivíduos, de ambos os gêneros (média de idade 47,17±8 anos). No local de trabalho, foi realizada a avaliação do nível pessoal de atenuação do Protetor Auditivo (PA) pelo método Field Microphone-in-Real-Ear (f-MIRE), seguido por orientações sobre a importância do uso do PA, higienização, armazenamento e treinamento para sua colocação efetiva. Resultados As análises mostraram que houve atenuação estatisticamente significante para todos os dados coletados (ruído total, por banda de frequência e dose) quando comparados os níveis de ruído no microfone lapela e no microfone sonda. Na comparação entre os valores de atenuação fornecidos pelo fabricante e os encontrados neste estudo, observou-se valores maiores para o fabricante em todas as bandas de frequência. Não houve diferença para os níveis de ruído nas diferentes atividades e horários avaliados. Conclusão Os achados do presente estudo possibilitaram conhecer o nível pessoal de atenuação do protetor auditivo durante uma situação real de trabalho, que estava dentro dos limites de tolerância. Também foi possível coletar informações sobre o ruído do ambiente em que esses trabalhadores estão expostos, onde observamos situações nas quais esse nível ultrapassava os valores de segurança, sendo assim recomendável o uso do PA. É importante que mais estudos sejam realizados utilizando o método f-MIRE, pois pode ser um aliado para avaliar a eficácia da atenuação do PA no local de trabalho.