Yaman Manaserh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yaman Manaserh has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad R. Gharaibeh
Department of Mechanical Engineering, ES2 Center, Binghamton University-SUNY , Binghamton, NY 13902
3 shared publications - Bahgat Sammakia
Department of Mechanical Engineering, Binghamton University-SUNY, Binghamton, NY 13902
3 shared publications - Cong Hiep Hoang
Department of Mechanical Engineering, State University of New York at Binghamton, Binghamton, NY, USA
3 shared publications - Mohammad I. Tradat
Department of Mechanical Engineering, ES2 Center, Binghamton University-SUNY , Binghamton, NY 13902
3 shared publications - Mohammad Tradat
Binghamton University
3 shared publications Alfonso Ortega
Department of Mechanical Engineering, Villanova University, Villanova, PA, USA
2 shared publications
Latest Publications
- Open Access
- 21 July 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (14) , 6229
Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling
Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO2, CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.
- 21 July 2024
- Published by MDPI AG in Sustainability
- Vol. 16 (14) , 6229
Open AccessEnergy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling
Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO2, CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.
- 24 May 2024
- Published by ASME International in Journal of Electronic Packaging
- Vol. 146 (4) , 1-17
Experimental and Numerical Investigation of Single-Phase Liquid Cooling for Heterogeneous Integration Multichip Module
The variety of new electronic packaging technologies has grown significantly over the last 20 years as a result of market demands for higher device performance at lower costs and in less space. Those demands have pushed for heterogeneous packaging, where computer chips with different stack heights are closely packed, creating nonuniform heat flux and temperature and additional challenges for thermal management. Without implementing an appropriate thermal management strategy for heterogeneous packages, large temperature gradients can be observed within the package, which would increase the thermal stresses on the chip and raise reliability issues. To mimic this real-life scenario of such packaging, an experimental setup was designed and built. The design of the new experimental setup consists of four identical 1.2 cm × 1.2 cm ceramic heaters, each of which is connected to a separate power supply and can reach a heat flux of 140 W/cm2. Accordingly, this mock package is capable of delivering different power levels to mimic different multicore microprocessor conditions. To give the heater the ability to move precisely in the x-, y-, and z-directions, each heater is mounted to an XYZ linear stage. Deionized water (DI) was used as the working fluid, and a pin-fin heat sink was used to run the initial steady-state tests on the experimental rig. The tests showed how different flow rates at a constant fluid temperature and input power affect the temperatures of the heaters and the thermohydraulic performance of the heat sink. In addition, a three-dimensional numerical model has been developed and validated with experimental data in terms of heat sink pressure drop and the temperatures of the heaters.
- 24 May 2024
- Published by ASME International in Journal of Electronic Packaging
- Vol. 146 (4) , 1-17
Experimental and Numerical Investigation of Single-Phase Liquid Cooling for Heterogeneous Integration Multichip Module
The variety of new electronic packaging technologies has grown significantly over the last 20 years as a result of market demands for higher device performance at lower costs and in less space. Those demands have pushed for heterogeneous packaging, where computer chips with different stack heights are closely packed, creating nonuniform heat flux and temperature and additional challenges for thermal management. Without implementing an appropriate thermal management strategy for heterogeneous packages, large temperature gradients can be observed within the package, which would increase the thermal stresses on the chip and raise reliability issues. To mimic this real-life scenario of such packaging, an experimental setup was designed and built. The design of the new experimental setup consists of four identical 1.2 cm × 1.2 cm ceramic heaters, each of which is connected to a separate power supply and can reach a heat flux of 140 W/cm2. Accordingly, this mock package is capable of delivering different power levels to mimic different multicore microprocessor conditions. To give the heater the ability to move precisely in the x-, y-, and z-directions, each heater is mounted to an XYZ linear stage. Deionized water (DI) was used as the working fluid, and a pin-fin heat sink was used to run the initial steady-state tests on the experimental rig. The tests showed how different flow rates at a constant fluid temperature and input power affect the temperatures of the heaters and the thermohydraulic performance of the heat sink. In addition, a three-dimensional numerical model has been developed and validated with experimental data in terms of heat sink pressure drop and the temperatures of the heaters.
- 8 August 2022
- Published by ASME International in Journal of Electronic Packaging
- Vol. 145 (2)
Performance Analysis of Corrosion Resistant Electroless Nickel-Plated Impinging Computer Numerical Control Manufactured Liquid Cooling Cold Plate
More than ever before, data centers must deploy robust thermal solutions to adequately host the high-density and high-performance computing that is in high demand. The newer generation of central processing units (CPUs) and graphics processing units (GPUs) has substantially higher thermal power densities than previous generations. In recent years, more data centers rely on liquid cooling for the high-heat processors inside the servers and air cooling for the remaining low-heat information technology equipment. This hybrid cooling approach creates a smaller and more efficient data center. The deployment of direct-to-chip cold plate liquid cooling is one of the mainstream approaches to providing concentrated cooling to targeted processors. In this study, a processor-level experimental setup was developed to evaluate the cooling performance of a novel computer numerical control (CNC) machined nickel-plated impinging cold plate on a 1 in. × 1 in. mock heater that represents a functional processing unit. The pressure drop and thermal resistance performance curves of the electroless nickel-plated cold plate are compared to those of a pure copper cold plate. A temperature uniformity analysis is done using compuational fluid dynamics and compared to the actual test data. Finally, the CNC machined pure copper one is compared to other reported cold plates to demonstrate its superiority of the design with respect to the cooling performance.
- 8 August 2022
- Published by ASME International in Journal of Electronic Packaging
- Vol. 145 (2)
Performance Analysis of Corrosion Resistant Electroless Nickel-Plated Impinging Computer Numerical Control Manufactured Liquid Cooling Cold Plate
More than ever before, data centers must deploy robust thermal solutions to adequately host the high-density and high-performance computing that is in high demand. The newer generation of central processing units (CPUs) and graphics processing units (GPUs) has substantially higher thermal power densities than previous generations. In recent years, more data centers rely on liquid cooling for the high-heat processors inside the servers and air cooling for the remaining low-heat information technology equipment. This hybrid cooling approach creates a smaller and more efficient data center. The deployment of direct-to-chip cold plate liquid cooling is one of the mainstream approaches to providing concentrated cooling to targeted processors. In this study, a processor-level experimental setup was developed to evaluate the cooling performance of a novel computer numerical control (CNC) machined nickel-plated impinging cold plate on a 1 in. × 1 in. mock heater that represents a functional processing unit. The pressure drop and thermal resistance performance curves of the electroless nickel-plated cold plate are compared to those of a pure copper cold plate. A temperature uniformity analysis is done using compuational fluid dynamics and compared to the actual test data. Finally, the CNC machined pure copper one is compared to other reported cold plates to demonstrate its superiority of the design with respect to the cooling performance.
- 1 November 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 247
Shifting to energy efficient hybrid cooled data centers using novel embedded floor tiles heat exchangers
- 1 November 2021
- Published by Elsevier in Energy Conversion and Management
- Vol. 247
Shifting to energy efficient hybrid cooled data centers using novel embedded floor tiles heat exchangers
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 11 (10) , 1565-1582
A Review of Recent Developments in Pumped Two-Phase Cooling Technologies for Electronic Devices
In this review, the heat transfer characteristics of several pumped two-phase electronic cooling technologies are quantitatively examined and compared on the basis of heat flux, coolant temperatures, heat source area, base temperature, and coolant type. Cooling by parallel flow in mini/microchannels, pin fins, spray cooling, and jet impingement are discussed in detail. Chip powers up to 2.9 kW and heat fluxes 910 W/cm 2 were demonstrated. The different surface modification techniques used to enhance heat transfer in all four technologies are also presented. Various coolants used in two-phase cooling applications are also quantitatively compared in terms of heat transfer coefficient (HTC), wall temperature, and heat source area. The current issues and potential research in two-phase cooling were also discussed. Water cooling has really high performance in terms of HTC. However, it is challenging for scientists and engineers to implement two-phase cooling with water at wall temperature lower than 100 °C due to high boiling point of water at atmospheric pressure. Therefore, two-phase cooling with water can be implemented in types of electronics that can tolerate higher junction temperature. Although having lower HTC, due to lower boiling point at atmospheric pressure, dielectric coolant can be a promising solution in two-phase cooling when lower chip temperatures are required. Geometry optimization of heat sinks is a promising research topic and has not been studied extensively considering the geometry parameters and solid–liquid interaction that affect thermal and hydraulic performance.
- 4 October 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 11 (10) , 1565-1582
A Review of Recent Developments in Pumped Two-Phase Cooling Technologies for Electronic Devices
In this review, the heat transfer characteristics of several pumped two-phase electronic cooling technologies are quantitatively examined and compared on the basis of heat flux, coolant temperatures, heat source area, base temperature, and coolant type. Cooling by parallel flow in mini/microchannels, pin fins, spray cooling, and jet impingement are discussed in detail. Chip powers up to 2.9 kW and heat fluxes 910 W/cm 2 were demonstrated. The different surface modification techniques used to enhance heat transfer in all four technologies are also presented. Various coolants used in two-phase cooling applications are also quantitatively compared in terms of heat transfer coefficient (HTC), wall temperature, and heat source area. The current issues and potential research in two-phase cooling were also discussed. Water cooling has really high performance in terms of HTC. However, it is challenging for scientists and engineers to implement two-phase cooling with water at wall temperature lower than 100 °C due to high boiling point of water at atmospheric pressure. Therefore, two-phase cooling with water can be implemented in types of electronics that can tolerate higher junction temperature. Although having lower HTC, due to lower boiling point at atmospheric pressure, dielectric coolant can be a promising solution in two-phase cooling when lower chip temperatures are required. Geometry optimization of heat sinks is a promising research topic and has not been studied extensively considering the geometry parameters and solid–liquid interaction that affect thermal and hydraulic performance.
- Open Access
- 16 July 2021
- Published by ASME International
Liquid Cooling Utilizing a Hybrid Micro-Channel/multi-Jet Heat Sink: A Component Level Study of Commercial Product
The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high-power demands can be met, while the reliability of the electronic devices is greatly improved. In this paper, thermo-hydraulic performance of a commercial hybrid micro-channel/slot-jet heat sink with
- 16 July 2021
- Published by ASME International
Open AccessLiquid Cooling Utilizing a Hybrid Micro-Channel/multi-Jet Heat Sink: A Component Level Study of Commercial Product
The miniaturization of microelectronic devices and an increasing demand for clock speed result in high heat flux systems. By adopting direct liquid cooling, the high heat flux and high-power demands can be met, while the reliability of the electronic devices is greatly improved. In this paper, thermo-hydraulic performance of a commercial hybrid micro-channel/slot-jet heat sink with