    Parameters of performance: A deep dive into liquid-to-air CDU assessment

    by Ali Heydari, Ahmad R. Gharaibeh, Mohammad Tradat, Qusai Soud, Yaman Manaserh, Vahideh Radmard, Bahareh Eslami, Jeremy Rodriguez, Bahgat Sammakia


  • Experimental and Numerical Investigation of Single-Phase Liquid Cooling for Heterogeneous Integration Multichip Module

    by Ahmad R. Gharaibeh, Qusai Soud, Yaman Manaserh, Mohammad Tradat, Bahgat Sammakia

    The variety of new electronic packaging technologies has grown significantly over the last 20 years as a result of market demands for higher device performance at lower costs and in less space. Those demands have pushed for heterogeneous packaging, where computer chips with different stack heights are closely packed, creating nonuniform heat flux and temperature and additional challenges for thermal management. Without implementing an appropriate thermal management strategy for heterogeneous packages, large temperature gradients can be observed within the package, which would increase the thermal stresses on the chip and raise reliability issues. To mimic this real-life scenario of such packaging, an experimental setup was designed and built. The design of the new experimental setup consists of four identical 1.2 cm × 1.2 cm ceramic heaters, each of which is connected to a separate power supply and can reach a heat flux of 140 W/cm2. Accordingly, this mock package is capable of delivering different power levels to mimic different multicore microprocessor conditions. To give the heater the ability to move precisely in the x-, y-, and z-directions, each heater is mounted to an XYZ linear stage. Deionized water (DI) was used as the working fluid, and a pin-fin heat sink was used to run the initial steady-state tests on the experimental rig. The tests showed how different flow rates at a constant fluid temperature and input power affect the temperatures of the heaters and the thermohydraulic performance of the heat sink. In addition, a three-dimensional numerical model has been developed and validated with experimental data in terms of heat sink pressure drop and the temperatures of the heaters.


  • Top Cited Papers

    Experimental evaluation of direct-to-chip cold plate liquid cooling for high-heat-density data centers

    by Ali Heydari, Ahmad R. Gharaibeh, Mohammad Tradat, Qusai Soud, Yaman Manaserh, Vahideh Radmard, Bahareh Eslami, Jeremy Rodriguez, Bahgat Sammakia


  • Performance Analysis of Corrosion Resistant Electroless Nickel-Plated Impinging Computer Numerical Control Manufactured Liquid Cooling Cold Plate

    by Vahideh Radmard, Ahmad R. Gharaibeh, Mohammad I. Tradat, Cong Hiep Hoang, Yaman Yaseen Manaserh, Kourosh Nemati, Scott N. Schiffres, Bahgat G. Sammakia

    More than ever before, data centers must deploy robust thermal solutions to adequately host the high-density and high-performance computing that is in high demand. The newer generation of central processing units (CPUs) and graphics processing units (GPUs) has substantially higher thermal power densities than previous generations. In recent years, more data centers rely on liquid cooling for the high-heat processors inside the servers and air cooling for the remaining low-heat information technology equipment. This hybrid cooling approach creates a smaller and more efficient data center. The deployment of direct-to-chip cold plate liquid cooling is one of the mainstream approaches to providing concentrated cooling to targeted processors. In this study, a processor-level experimental setup was developed to evaluate the cooling performance of a novel computer numerical control (CNC) machined nickel-plated impinging cold plate on a 1 in. × 1 in. mock heater that represents a functional processing unit. The pressure drop and thermal resistance performance curves of the electroless nickel-plated cold plate are compared to those of a pure copper cold plate. A temperature uniformity analysis is done using compuational fluid dynamics and compared to the actual test data. Finally, the CNC machined pure copper one is compared to other reported cold plates to demonstrate its superiority of the design with respect to the cooling performance.


  • Using a Multi-Inlet/Outlet Manifold to Improve Heat Transfer and Flow Distribution of a Pin Fin Heat Sink

    by Ahmad R. Gharaibeh, Yaman M. Manaserh, Mohammad I. Tradat, Firas W. AlShatnawi, Scott N. Schiffres, Bahgat G. Sammakia

    The increased power consumption and continued miniaturization of high-powered electronic components have presented many challenges to their thermal management. To improve the efficiency and reliability of these devices, the high amount of heat that they generate must be properly removed. In this paper, a three-dimensional numerical model has been developed and experimentally validated for several manifold heat sink designs. The goal was to enhance the heat sink's thermal performance while reducing the required pumping power by lowering the pressure drop across the heat sink. The considered designs were benchmarked to a commercially available heat sink in terms of their thermal and hydraulic performances. The proposed manifolds were designed to distribute fluid through alternating inlet and outlet branched internal channels. It was found that using the manifold design with 3 channels reduced the thermal resistance from 0.061 to 0.054 °C/W with a pressure drop reduction of 0.77 kPa from the commercial cold plate. A geometric parametric study was performed to investigate the effect of the manifold's internal channel width on the thermohydraulic performance of the proposed designs. It was found that the thermal resistance decreased as the manifold's channel width decreased, up until a certain width value, below which the thermal resistance started to increase while maintaining low-pressure drop values. Where the thermal resistance significantly decreased in the 7 channels design by 16.4% and maintained a lower pressure drop value below 0.6 kPa.


  • Shifting to energy efficient hybrid cooled data centers using novel embedded floor tiles heat exchangers

    by Yaman M. Manaserh, Mohammad I. Tradat, Ahmad R. Gharaibeh, Bahgat G. Sammakia, Russ Tipton