SHStefan Heldt

Stefan Heldt

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stefan Heldt has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of heterogeneity on high-temperature aquifer thermal energy storage: a case study

    by Stefan Heldt, Christof Beyer, Sebastian Bauer

    High-temperature Aquifer Thermal Energy Storage (HT-ATES) has the potential to reduce greenhouse gas emissions from the heating sector due to its capability of making excess or renewable based heat from the summer period available in winter. The economic viability of HT-ATES is largely determined by the thermal recovery, i.e. the fraction of recovered heat from the previously injected heat. The heterogeneity of the storage formation has an impact on both the induced thermal plume in the subsurface and on the thermal recovery and results in uncertainties of both parameters. This study aims at quantifying these uncertainties resulting from the subsurface heterogeneity.The case study of Hamburg-Wilhelmsburg (Northern Germany) is considered, where heat can be stored in the Lower Lignite Sands at around 200 m b.g.l. The geostatistical data basis consisted of 26 boreholes in HH-Wilhelmsburg and 476 boreholes distributed over the whole of Hamburg. The lithologies described in these boreholes were grouped into three indicators with high, medium and low permeability, which were parameterized by literature data. Indicator variogram analysis was applied and the thus derived geostatistical parameters were used for conditional sequential indicator simulation, resulting in 30 realizations of indicator distributions for the model domain. HT-ATES operation was simulated for 26 years by a thermo-hydraulically coupled model with OpenGeoSys. In three additional scenarios with 30 realization each, three different exploration boreholes were added to the conditioning data at a distance of 10 m to the warm ATES well, in order to examine the resulting benefit of such an exploration borehole for reducing the prediction uncertainty.Simulation results show that considering the heterogeneity of the hydraulic permeability leads to substantial variability in the predicted thermal plume. This spatial uncertainty is reduced in all three scenarios which include an exploration borehole. Also, the predicted warm well return temperatures are significantly less variable between realizations, when the exploration boreholes are included in the conditioning data. For the scenario without an exploration well the mean thermal recovery increases from 36% in the first year to 63% in the 26th year. The standard deviation of the thermal recovery thereby increases from 7% to 10%. The exploration borehole scenarios show different mean thermal recoveries of 29%, 41% and 46% in year one and 53%, 78% and 84% in year 26. The standard deviation is maximum 2% in all three scenarios at all times. This shows, that a large reduction in uncertainty can be expected if an exploration borehole in the direct vicinity of the ATES warm well is available.

  • Open Access

    Evaluating the impact of anisotropy and low-permeability layers on high temperature aquifer thermal energy storage performance

    by Stefan Heldt, Sebastian Bauer

    The seasonal storage of heat has the potential to reduce greenhouse gas emissions, since it accounts for the seasonal disbalance between heat production and demand in renewable-based energy-systems. High temperature aquifer thermal energy storage (HT-ATES) is a heat storage technology utilising the subsurface and therefore provides high storage capacity with limited above-ground usage, which is especially required in urban areas. Since the temperature difference between the ambient groundwater and the injected water (> 50 °C) results in density differences, convective buoyancy flow can be induced by HT-ATES. This process leads to an uneven heat distribution over the aquifer thickness, reduced storage efficiency and increased thermal impacts. The occurrence and intensity of buoyancy flow is site-specific, since it depends on operational parameters, such as injection temperature, as well as geological parameters, such as aquifer thickness and especially vertical and horizontal permeability.The geological site considered for HT-ATES storage is located in Hamburg, Germany, using the Miocene Lower Braunkohlensande (brown coal sands) as storage aquifer. This sedimentological formation was deposited in a coastal transition regime between terrestrial and shallow-marine settings and consists mainly of sands. Peat swamps and lagoons formed brown coal, silt and clay layers, which have the potential to hinder convection due to their low permeability, depending on their lateral extent in relation to the size of the induced heat plume by HT-ATES. Lithological classifications of 25 wells provide the data basis for the geological analysis.The aim of this study is to evaluate the influence of thin low permeability layers on induced buoyancy flow and thus HT-ATES performance, as measured by heat recovery. To this end, a site-specific numerical HT-ATES model is created, which simulates the coupled thermo-hydraulic processes. Different scenarios with varied vertical permeability as well as the number and lateral extent of low-permeability layers show the effect on density-driven buoyancy flow and HT-ATES efficiency. Increasing the vertical permeability by a factor of 10 results in an efficiency decrease from 78 % to 57 % in the 10th storage cycle. The findings serve as a process understanding basis for complex heterogeneous facies models of the HT-ATES site, which will be based on the geostatistical evaluation of site data.

  • Open Access

    Parameter identification and range restriction through sensitivity analysis for a high-temperature heat injection test

    by Stefan Heldt, Bo Wang, Sebastian Bauer

    In order to compensate for the variable mismatch between heat demand and heat production from renewable sources or waste heat, high-temperature aquifer thermal energy storage (HT-ATES) is a promising option. A reliable prediction of the energetic performance as well as thermal and hydraulic impacts of a HT-ATES requires a suitable model parameterization regarding the subsurface properties. In order to identify the subsurface parameters on which investigation efforts should be focused, we carried out an extensive sensitivity analysis of the thermal and hydraulic parameters for a high-temperature heat injection test (HIT) using numerical modeling of the governing coupled thermo-hydraulic processes. The heat injection test was carried out in a quaternary shallow aquifer using injection temperatures of about 75 °C over 5 days, accompanied by an extensive temperature monitoring. The sensitivity analysis is conducted for parameter ranges based on literature values, based on site investigation at the HIT site and based on a model calibrated to the measured temperature distribution following the heat injection. Comparing the parameter ranges thus obtained in this three-step approach allows to identify those parameters, for which model prediction uncertainty decreased most, which are also the parameters, that strongly affect the thermal behavior. The highest sensitivity is found for vertical and horizontal hydraulic conductivity as well as for groundwater flow velocity, indicating that investigation efforts for HT-ATES projects should focus on these parameters. Heat capacity and thermal conductivity have a smaller impact on the temperature distribution. Our work thus yields a consistent approach to identifying the parameters which can be best restricted by field investigations and subsequent model calibration. Focusing on these during field investigations thus enable improved model predictions of both HT-ATES operation and induced impacts.


  • Open Access

    Thermal Impact of High Temperature Aquifer Thermal Energy Storage on Overlying Layers

    by Stefan Heldt, Sebastian Bauer

    High temperature Aquifer Thermal Energy Storage (HT-ATES) is one option to compensate for the seasonal mismatch between supply and demand in a renewable dominated heating sector. The thermal impacts to be expected by a planned HT-ATES plant can be predicted by numerical modelling, which is necessary for the development of monitoring concepts, legal authorization and economical assessments. One aspect of numerical pre-investigations, which was mostly disregarded by previous studies, is the assessment of thermal impacts in layers above the storage formation, which are heated conductively by the warm well. Furthermore, a quantification of the related heat losses and the implications on storage efficiency need to be considered.The thermohydraulic processes induced by the HT-ATES are numerically simulated by a radially symmetric model neglecting ambient groundwater flow. The model includes the discretised warm ATES well, which reaches to a depth of ≈250 m and the surrounding geological layers. The geology and the operational scheme are based on a typical setting representative for northern Germany. The simplified operational scheme consists of half a year injection and half a year extraction, repeated for 50 years, with an injection temperature of 85 °C, varying return flow temperatures and an initial subsurface temperature of 13 °C. The thermal properties of the well casing are varied in a sensitivity study to estimate the influence of different material choices.The model results show, that a temperature increase of 5 °C propagates 7 m radially in cohesive layers around the well in the first year of operation. After 50 years, temperature increases of 5 °C or more are found within a distance of about 40 m, 30 °C within about 13 m and 50 °C within about 2 m. Density-driven buoyancy flow is observed in cohesionless layers, leading to heat accumulation near the top of these layers. The heat consequently propagates significantly further there than in the cohesive formations, e.g. a temperature increase of 5 °C propagates maximally 121 m from the well in 50 years. The conductive heat loss to the overlaying formations through the well casing is 2 % of the injected heat. The such derived estimation of thermal impacts in overlaying formations is conservative, since ambient groundwater flow is neglected, which would result in lower temperatures due to advective heat transport away from the well. The heat loss, however, would be larger with groundwater flow, since this would reduce temperatures around the well and thus increase the temperature gradients and the conductive heat transport. Material choices of the well material may increase or decrease the heat losses and thus the thermal impacts.

  • Open Access

    Predictability of initial hydrogeochemical effects induced by short-term infiltration of ∼75 °C hot water into a shallow glaciogenic aquifer

    by Klas Lüders, Götz Hornbruch, Nilufar Zarrabi, Stefan Heldt, Andreas Dahmke, Ralf Köber


  • Open Access

    Data of a high temperature heat injection test

    by Stefan Heldt, Bo Wang, Linwei Hu, Götz Hornbruch, Klas Lüders, Ulrike Werban, Sebastian Bauer


  • Open Access

    A High Temperature Heat Injection Test – Numerical Modelling and Sensitivity Analysis

    by Stefan Heldt, Bo Wang, Sebastian Bauer

    With the transition of the heating sector towards renewable energy sources technologies are needed to compensate for the seasonal mismatch between heat supply and demand. Aquifer thermal energy storage (ATES) is considered a promising candidate for that purpose. Especially high temperature ATES (HT-ATES) with temperatures up to 90 °C has the advantage of higher storage capacities and allows for the direct use of the stored heat without intermediate heat pumps. In order to improve the understanding of processes induced by HT-ATES and to validate numerical tools for the prediction of storage capacities, storage rates as well as thermal impacts, a heat injection field test with an injection temperature of 75 °C was conducted, densely monitored and numerically simulated. This work presents a sensitivity analysis of the governing processes and parameters, from which the parameters on which the simulation results are most dependent are derived and thus identified for future site characterization and monitoring studies.The heat injection test took place at a shallow aquifer with a low natural groundwater flow velocity of 0.07 m/d. Hot water was injected at a borehole using flow rates of 14 l/min for 4.5 days and the resulting thermal plume was monitored by a dense arrangement of thermocouples. Previous to the experiment, the field site was thoroughly investigated for the thermal and hydraulic parameters by standard hydrogeological methods, such as pumping tests, hydraulic head measurements, Hydraulic Profiling Tool (HTP) employment, liner sampling and laboratory measurements.  A coupled heat transport and fluid flow model was set up and the heat injection test was simulated using high resolution numerical modelling of the coupled thermo-hydraulic processes using the OpenGeoSys (OGS) simulation code.The comparison of measured and simulated temperature breakthrough curves showed a good correspondence, indicating the capability of the model to predict the general thermal behaviour of the heat injection test. The accuracy was higher for larger distances to the injection well and at the longer time scale, while the largest deviations occurred close to the injection well and shortly after the injection. The model was then used to estimate the sensitivity of the simulated temperature distribution on thermal and hydraulic aquifer parameters, which were varied according to the span of measurements. The thermal plume development is most sensitive on the hydraulic conductivity, since this parameter influences the intensity of buoyancy driven flow and was measured in the large range 3.00E-05 to 7.15 E-04 m/s. The dispersivity and the anisotropy in hydraulic conductivity effect the same process and show a significant impact on the result as well, together with the thermal conductivity. The sensitivity of the simulated temperature distribution on the groundwater flow velocity and the specific heat capacity is a little lower compared to the previously mentioned parameters, while the result is insensitive to the specific storage. It is shown, that a heat injection test in combination with numerical simulations is suitable for identifying parameter sensitivities also on small scales, thus showing the investigation needs for HT-ATES projects.