Yousuke Nakashima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Yousuke Nakashima has a total of 152 co-authors. Here are the top co-authors by number of shared publications:
- Mafumi Hirata
University of Tsukuba
6 shared publications - Masayuki Yoshikawa
University of Tsukuba
6 shared publications - Mizuki Sakamoto
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
6 shared publications - Naomichi Ezumi
University of Tsukuba
5 shared publications K. Yatsu
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
4 shared publicationsN. Nishino
Graduate School of Engineering, Hiroshima University, Higashi-Hiroshima, 739-8527, Japan
4 shared publications
Latest Publications
- Open Access
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Behavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Open AccessBehavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053506
Measurement of axial phase difference of density fluctuations owing to spontaneously excited waves by using microwave reflectometer on GAMMA 10/PDX
In the GAMMA 10/PDX tandem mirror, plasma with strong ion-temperature anisotropy is produced by using the ion cyclotron range of frequency waves. This anisotropy of ion temperature causes several Alfvén-Ion-Cyclotron (AIC) waves to spontaneously excite in the frequency range just below the ion cyclotron frequency. In addition, difference-frequency (DF) waves are excited in the radial inner region of the plasma by wave–wave coupling among the AIC waves. The radial density profiles were measured at multi-axial positions using a frequency-modulation reflectometer with an axial array of microwave antennas, and an axial variation of the density was found to be significant. In addition, a relative phase difference of the DF wave between axially separated two points was first obtained by finely choosing the probing frequency of the reflectometers with a maximum coherence used as a measure, indicating that the DF wave is a propagating wave, while the pump AIC waves are standing waves in the axial region of measurement.
- 1 May 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (5) , 053506
Measurement of axial phase difference of density fluctuations owing to spontaneously excited waves by using microwave reflectometer on GAMMA 10/PDX
In the GAMMA 10/PDX tandem mirror, plasma with strong ion-temperature anisotropy is produced by using the ion cyclotron range of frequency waves. This anisotropy of ion temperature causes several Alfvén-Ion-Cyclotron (AIC) waves to spontaneously excite in the frequency range just below the ion cyclotron frequency. In addition, difference-frequency (DF) waves are excited in the radial inner region of the plasma by wave–wave coupling among the AIC waves. The radial density profiles were measured at multi-axial positions using a frequency-modulation reflectometer with an axial array of microwave antennas, and an axial variation of the density was found to be significant. In addition, a relative phase difference of the DF wave between axially separated two points was first obtained by finely choosing the probing frequency of the reflectometers with a maximum coherence used as a measure, indicating that the DF wave is a propagating wave, while the pump AIC waves are standing waves in the axial region of measurement.
- Open Access
- 19 March 2021
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 16, 2402041
Influence of Nitrogen Ratio on Plasma Detachment during Combined Seeding with Hydrogen on Divertor Simulation Experiment of GAMMA 10/PDX
Influences of nitrogen ratio on plasma detachment and molecular activated recombination (MAR) processes during combined seeding with hydrogen have been investigated utilizing end-loss plasma in the GAMMA 10/PDX tandem mirror. Additional gases were injected under the condition that hydrogen partial pressure was fixed and nitrogen partial pressure was changed from 0% - 10% compared to that of hydrogen. Electron density and ion flux further decrease with increasing nitrogen ratio. In addition, it is suggested that the hydrogen-MAR process that begins with dissociative attachment is suppressed during combined seeding of nitrogen and hydrogen. Observed emission spectrum of NH radicals suggests that the density of NH increases as nitrogen ratio increases and nitrogen-induced MAR efficiently contributes to the reduction of particle flux.
- 19 March 2021
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 16, 2402041
Open AccessInfluence of Nitrogen Ratio on Plasma Detachment during Combined Seeding with Hydrogen on Divertor Simulation Experiment of GAMMA 10/PDX
Influences of nitrogen ratio on plasma detachment and molecular activated recombination (MAR) processes during combined seeding with hydrogen have been investigated utilizing end-loss plasma in the GAMMA 10/PDX tandem mirror. Additional gases were injected under the condition that hydrogen partial pressure was fixed and nitrogen partial pressure was changed from 0% - 10% compared to that of hydrogen. Electron density and ion flux further decrease with increasing nitrogen ratio. In addition, it is suggested that the hydrogen-MAR process that begins with dissociative attachment is suppressed during combined seeding of nitrogen and hydrogen. Observed emission spectrum of NH radicals suggests that the density of NH increases as nitrogen ratio increases and nitrogen-induced MAR efficiently contributes to the reduction of particle flux.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033515
Improvement in multipass Thomson scattering system comprising laser amplification system developed in GAMMA 10/PDX
The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter–simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.
- 1 March 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (3) , 033515
Improvement in multipass Thomson scattering system comprising laser amplification system developed in GAMMA 10/PDX
The multipass Thomson scattering (MPTS) technique is one of the most useful methods for measuring low-electron-density plasmas. The MPTS system increases Thomson scattering (TS) signal intensities by integrating all multipass (MP) signals and improving the TS time resolution by analyzing each pass signal. The fully coaxial MPTS system developed in GAMMA 10/potential-control and diverter–simulator experiments has a polarization-based configuration with image-relaying optics. The MPTS system can enhance Thomson scattered signals for improving the measurement accuracy and megahertz-order time resolution. In this study, we develop a new MPTS system comprising a laser amplification system to obtain continuous MP signals. The laser amplification system can improve degraded laser power and return an amplified laser to the MP system. We obtain continuous MP signals from the laser amplification system by improving the laser beam profile adjuster in gas scattering experiments. Moreover, we demonstrate that more MP signals and stronger amplified MP signals can be achieved via multiple laser injections to the laser amplification system in the developed MP system comprising a laser amplification system.
- Open Access
- 1 May 2019
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 19, 149-154
Characteristics of plasma flow profiles in a super-X-divertor-like configuration
- 1 May 2019
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 19, 149-154
Open AccessCharacteristics of plasma flow profiles in a super-X-divertor-like configuration
- Open Access
- 24 January 2019
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 14, 2405013
Recent Advancement of Research on Plasma Direct Energy Conversion
Present plasma direct energy conversion (DEC) system has been developed since proposal of ARTEMIS. The system for D-3He reactor is composed of cusp-type DEC (CuspDEC) for particle discrimination, traveling wave DEC (TWDEC) for recovery of high energy protons, and secondary electron DEC (SEDEC) for recovery of extremely accelerated protons. Studies on each device are in the third stage, where higher capability of each device will be derived. Various proposals and examinations were reported and the present paper treats the researches comprehensively and shows explanation and discussion for some researches: separation of high density plasma and ion-ion separation in CuspDEC, studies on modulation in TWDEC, and improvement of electron collection in SEDEC.
- 24 January 2019
- Published by Japan Society of Plasma Science and Nuclear Fusion Research in Plasma and Fusion Research
- Vol. 14, 2405013
Open AccessRecent Advancement of Research on Plasma Direct Energy Conversion
Present plasma direct energy conversion (DEC) system has been developed since proposal of ARTEMIS. The system for D-3He reactor is composed of cusp-type DEC (CuspDEC) for particle discrimination, traveling wave DEC (TWDEC) for recovery of high energy protons, and secondary electron DEC (SEDEC) for recovery of extremely accelerated protons. Studies on each device are in the third stage, where higher capability of each device will be derived. Various proposals and examinations were reported and the present paper treats the researches comprehensively and shows explanation and discussion for some researches: separation of high density plasma and ion-ion separation in CuspDEC, studies on modulation in TWDEC, and improvement of electron collection in SEDEC.
- 1 January 2011
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 59 (1T) , 61-66
Research Plan for Divertor Simulation Studies and Its Recent Results Using the GAMMA 10 Tandem Mirror
As the new research plan of Plasma Research Center of the University of Tsukuba, we are planning to start a study of divertor simulation under the closely resemble to actual fusion plasmas environment making an advantage of the GAMMA 10 tandem mirror and to contribute the solution for realizing the divertor in future toroidal systems. In the research plan, the concepts of two divertor devices are introduced. One has an axi-symmetric divertor configuration with separatrix (A-Div.) and the other is a high heat flux divertor simulator by using an end-mirror exit of the large tandem mirror device (E-Div.). Preparative experiments have been successfully started at the end-mirror region of GAMMA 10 and detailed behavior of end-loss particles has been investigated by using newly developed diagnostic instruments. In standard hot-ion mode plasmas (ne0 ~ 2 × 1018 m-3, Ti0 ~ 5 keV), the heat flux density of 0.8 MW/m2 and the particle flux density of 4 × 1022/s·m2 were observed at 30 cm downstream of the end-mirror exit on the machine axis. It is confirmed that the heat flux density increases in proportion to the applied RF power. Superimposing the ECH pulse induces a remarkable enhancement of heat flux and a peak value in the net heat flux density of 8 MW/m2 was attained during the ECH injection, which almost comes up to the heat load level of the divertor plate of ITER. Two-dimensional visible image measurement of newly installed target plates using high-speed camera revealed a significant difference in the behavior of visible emission from plasma-material interaction. The above results give a clear prospect of generating the required performance and providing useful information for divertor studies in GAMMA 10.
- 1 January 2011
- Published by Taylor & Francis in Fusion Science and Technology
- Vol. 59 (1T) , 61-66
Research Plan for Divertor Simulation Studies and Its Recent Results Using the GAMMA 10 Tandem Mirror
As the new research plan of Plasma Research Center of the University of Tsukuba, we are planning to start a study of divertor simulation under the closely resemble to actual fusion plasmas environment making an advantage of the GAMMA 10 tandem mirror and to contribute the solution for realizing the divertor in future toroidal systems. In the research plan, the concepts of two divertor devices are introduced. One has an axi-symmetric divertor configuration with separatrix (A-Div.) and the other is a high heat flux divertor simulator by using an end-mirror exit of the large tandem mirror device (E-Div.). Preparative experiments have been successfully started at the end-mirror region of GAMMA 10 and detailed behavior of end-loss particles has been investigated by using newly developed diagnostic instruments. In standard hot-ion mode plasmas (ne0 ~ 2 × 1018 m-3, Ti0 ~ 5 keV), the heat flux density of 0.8 MW/m2 and the particle flux density of 4 × 1022/s·m2 were observed at 30 cm downstream of the end-mirror exit on the machine axis. It is confirmed that the heat flux density increases in proportion to the applied RF power. Superimposing the ECH pulse induces a remarkable enhancement of heat flux and a peak value in the net heat flux density of 8 MW/m2 was attained during the ECH injection, which almost comes up to the heat load level of the divertor plate of ITER. Two-dimensional visible image measurement of newly installed target plates using high-speed camera revealed a significant difference in the behavior of visible emission from plasma-material interaction. The above results give a clear prospect of generating the required performance and providing useful information for divertor studies in GAMMA 10.
- 28 April 2009
- Published by IOP Publishing in Nuclear Fusion
- Vol. 49 (5) , 055020
Active particle control experiments and critical particle flux discriminating between the wall pumping and fuelling in the compact plasma wall interaction device CPD spherical tokamak
Two approaches associated with wall recycling have been performed in a small spherical tokamak device CPD (compact plasma wall interaction experimental device), that is, (1) demonstration of active particle recycling control, namely, ‘active wall pumping’ using a rotating poloidal limiter whose surface is continuously gettered by lithium and (2) a basic study of the key parameters which discriminates between ‘wall pumping and fuelling’. For the former, active control of ‘wall pumping’ has been demonstrated during 50 kW RF current drive discharges whose pulse length is typically ∼300 ms. Although the rotating limiter is located at the outer board, as soon as the rotating drum is gettered with lithium, hydrogen recycling measured with Hα spectroscopy decreases by about a factor of 3 not only near the limiter but also in the centre stack region. Also, the oxygen impurity level measured with O II spectroscopy is reduced by about a factor of 3. As a consequence of the reduced recycling and impurity level, RF driven current has nearly doubled at the same vertical magnetic field. For the latter, global plasma wall interaction with plasma facing components in the vessel is studied in a simple torus produced by electron cyclotron waves with I p < 1 kA. A static gas balance (pressure measurement) without external pumping systems has been performed to investigate the role of particle flux on a transition of ‘wall fuelling’ to ‘wall pumping’. It is found that a critical particle flux exists to discriminate between them. Beyond the critical value, a large fraction (∼80%) of pressure drop (‘wall pumping’) is found, suggesting that almost all injected particles are retained in the wall. Below it, a significant pressure rise (‘wall fuelling’) is found, which indicates that particles are fuelled from the wall during/just after the discharge. Shot history effects (integrated particle recycling behaviour from the plasma facing surfaces) are seen on that the critical particle flux is reducing from 0.8 × 10−4 to ∼0.1 × 10−4 Torr during the experimental campaign (∼3000 shots). In the wall pumping pressure range the wall pumping fraction is reduced with increasing surface temperature up to 150 °C.
- 28 April 2009
- Published by IOP Publishing in Nuclear Fusion
- Vol. 49 (5) , 055020
Active particle control experiments and critical particle flux discriminating between the wall pumping and fuelling in the compact plasma wall interaction device CPD spherical tokamak
Two approaches associated with wall recycling have been performed in a small spherical tokamak device CPD (compact plasma wall interaction experimental device), that is, (1) demonstration of active particle recycling control, namely, ‘active wall pumping’ using a rotating poloidal limiter whose surface is continuously gettered by lithium and (2) a basic study of the key parameters which discriminates between ‘wall pumping and fuelling’. For the former, active control of ‘wall pumping’ has been demonstrated during 50 kW RF current drive discharges whose pulse length is typically ∼300 ms. Although the rotating limiter is located at the outer board, as soon as the rotating drum is gettered with lithium, hydrogen recycling measured with Hα spectroscopy decreases by about a factor of 3 not only near the limiter but also in the centre stack region. Also, the oxygen impurity level measured with O II spectroscopy is reduced by about a factor of 3. As a consequence of the reduced recycling and impurity level, RF driven current has nearly doubled at the same vertical magnetic field. For the latter, global plasma wall interaction with plasma facing components in the vessel is studied in a simple torus produced by electron cyclotron waves with I p < 1 kA. A static gas balance (pressure measurement) without external pumping systems has been performed to investigate the role of particle flux on a transition of ‘wall fuelling’ to ‘wall pumping’. It is found that a critical particle flux exists to discriminate between them. Beyond the critical value, a large fraction (∼80%) of pressure drop (‘wall pumping’) is found, suggesting that almost all injected particles are retained in the wall. Below it, a significant pressure rise (‘wall fuelling’) is found, which indicates that particles are fuelled from the wall during/just after the discharge. Shot history effects (integrated particle recycling behaviour from the plasma facing surfaces) are seen on that the critical particle flux is reducing from 0.8 × 10−4 to ∼0.1 × 10−4 Torr during the experimental campaign (∼3000 shots). In the wall pumping pressure range the wall pumping fraction is reduced with increasing surface temperature up to 150 °C.
- 24 January 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 511-515
Recycling studies based on two-dimensional visible light measurements and Monte-Carlo simulation in mirror and helical systems
- 24 January 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 511-515
Recycling studies based on two-dimensional visible light measurements and Monte-Carlo simulation in mirror and helical systems
- 23 January 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 428-431
Comparison of edge plasma behavior at different poloidal positions in Heliotron J
- 23 January 2009
- Published by Elsevier in Journal of Nuclear Materials
- Vol. 390-391, 428-431
Comparison of edge plasma behavior at different poloidal positions in Heliotron J