Mizuki Sakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mizuki Sakamoto has a total of 175 co-authors. Here are the top co-authors by number of shared publications:
- Naomichi Ezumi
University of Tsukuba
15 shared publications - Masayuki Yoshikawa
University of Tsukuba
11 shared publications J. Kohagura
Plasma Research Center, University of Tsukuba, Tsukuba, Ibaraki 305-8577, Japan
6 shared publications- Mafumi Hirata
University of Tsukuba
6 shared publications - Yousuke Nakashima
Plasma Research Center, University of Tsukuba
6 shared publications - Ichihiro Yamada
National Institute for Fusion Science, Toki, Gifu 509-5292, Japan
5 shared publications
Latest Publications
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
Machine-learning-based high-temporal-resolution electron temperature evaluation from photomultiplier tube signals in GAMMA 10/PDX: A tandem mirror plasma confinement device
In this study, we propose a new method of electron temperature (Te) measurements with higher temporal resolution using a photomultiplier tube combined with machine learning (ML). It has been demonstrated that Te can be evaluated from Balmer series emissions Dα, Dβ, Dγ, and molecular band emission (D2) [Nishijima et al., AIP Adv. 13, 055202 (2023)]. This method is applied to hydrogen plasmas in GAMMA 10/PDX, which is a large tandem mirror device. Balmer series emissions (Hα, Hβ, Hγ) and Fulcher band emissions are measured and correlated with Langmuir probe Te measurements in a divertor simulation experiment conducted in the GAMMA 10/PDX. Training datasets are constructed using these data. Two predictive models based on the random forest algorithm and the support vector regression algorithm are developed, enabling Te estimation directly from spectroscopic data. By employing PMTs with bandpass filters, we achieved Te measurement with higher temporal resolution than the fundamental method of Langmuir probes. Our results highlight the potential of ML-assisted spectroscopy as an alternative diagnostic tool under high heat load conditions and its applicability to feedback control in future fusion devices, including tokamaks.
- 1 February 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (2)
Machine-learning-based high-temporal-resolution electron temperature evaluation from photomultiplier tube signals in GAMMA 10/PDX: A tandem mirror plasma confinement device
In this study, we propose a new method of electron temperature (Te) measurements with higher temporal resolution using a photomultiplier tube combined with machine learning (ML). It has been demonstrated that Te can be evaluated from Balmer series emissions Dα, Dβ, Dγ, and molecular band emission (D2) [Nishijima et al., AIP Adv. 13, 055202 (2023)]. This method is applied to hydrogen plasmas in GAMMA 10/PDX, which is a large tandem mirror device. Balmer series emissions (Hα, Hβ, Hγ) and Fulcher band emissions are measured and correlated with Langmuir probe Te measurements in a divertor simulation experiment conducted in the GAMMA 10/PDX. Training datasets are constructed using these data. Two predictive models based on the random forest algorithm and the support vector regression algorithm are developed, enabling Te estimation directly from spectroscopic data. By employing PMTs with bandpass filters, we achieved Te measurement with higher temporal resolution than the fundamental method of Langmuir probes. Our results highlight the potential of ML-assisted spectroscopy as an alternative diagnostic tool under high heat load conditions and its applicability to feedback control in future fusion devices, including tokamaks.
- Open Access
- 6 December 2025
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 44 (2) , 66
Implementation and Technical Evaluation of Shot-by-Shot Data Transfer from GAMMA 10/PDX To LHD LABCOM Via SNET
We report the implementation and technical evaluation of a shot-by-shot data transfer system from the GAMMA 10/PDX tandem mirror device to the LHD LABCOM system via SNET, as part of the Fusion Virtual Laboratory project. Since 2008, we have transferred approximately 1.5 TB of experimental data annually. In 2023, we successfully established real-time CAMAC data transfer on a per-shot basis. This paper details the network architecture, data acquisition systems, transfer protocols, and operational reliability. The system enables remote access and supports collaborative research by providing timely and structured data to the LABCOM database. The technical performance and future development plans are also discussed.
- 6 December 2025
- Published by Springer Nature in Journal of Fusion Energy
- Vol. 44 (2) , 66
Open AccessImplementation and Technical Evaluation of Shot-by-Shot Data Transfer from GAMMA 10/PDX To LHD LABCOM Via SNET
We report the implementation and technical evaluation of a shot-by-shot data transfer system from the GAMMA 10/PDX tandem mirror device to the LHD LABCOM system via SNET, as part of the Fusion Virtual Laboratory project. Since 2008, we have transferred approximately 1.5 TB of experimental data annually. In 2023, we successfully established real-time CAMAC data transfer on a per-shot basis. This paper details the network architecture, data acquisition systems, transfer protocols, and operational reliability. The system enables remote access and supports collaborative research by providing timely and structured data to the LABCOM database. The technical performance and future development plans are also discussed.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10018
Development of an improved dual-path multi-pass Thomson scattering system in GAMMA 10/PDX
We report the development and optimization of a dual-path Thomson scattering (DPTS) system in GAMMA 10/PDX, designed for simultaneous measurements of electron temperature and density in both the central cell and divertor-simulated plasma regions. The system comprises a multi-pass central-cell TS and an upgraded end-cell TS (EC-TS) double-pass configuration, both tailored to enhance signal intensity. Short-pass filters were added to the polychromators to improve spectral selectivity, and newly installed apertures in the EC-TS system were used to suppress stray light. Experimental applications involving supersonic molecular beam injection, central electron cyclotron heating, and ion cyclotron heating confirmed successful concurrent observations of plasma parameters in the central cell.
- 1 October 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (10) , C10018
Development of an improved dual-path multi-pass Thomson scattering system in GAMMA 10/PDX
We report the development and optimization of a dual-path Thomson scattering (DPTS) system in GAMMA 10/PDX, designed for simultaneous measurements of electron temperature and density in both the central cell and divertor-simulated plasma regions. The system comprises a multi-pass central-cell TS and an upgraded end-cell TS (EC-TS) double-pass configuration, both tailored to enhance signal intensity. Short-pass filters were added to the polychromators to improve spectral selectivity, and newly installed apertures in the EC-TS system were used to suppress stray light. Experimental applications involving supersonic molecular beam injection, central electron cyclotron heating, and ion cyclotron heating confirmed successful concurrent observations of plasma parameters in the central cell.
- 29 May 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (6) , 060901
Discharge characteristics of a hybrid plasma source using hot cathode arc discharge and helicon wave discharge
High-density and large-diameter plasma generation is expected to contribute to semiconductor manufacturing, space propulsion, and nuclear fusion. We develop a plasma generation method for high-density, large-diameter plasma by combining the advantages of both hot cathode arc discharge and helicon wave discharge characteristics. The experiment confirmed that hybrid discharges produce a higher-density plasma compared to standalone arc discharges or helicon wave discharges across a wide range of gas pressures. Additionally, the diameter of the plasma was found to be twice as large as that of arc discharges alone. The mechanisms behind hybrid discharge and potential performance improvements are discussed.
- 29 May 2025
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 64 (6) , 060901
Discharge characteristics of a hybrid plasma source using hot cathode arc discharge and helicon wave discharge
High-density and large-diameter plasma generation is expected to contribute to semiconductor manufacturing, space propulsion, and nuclear fusion. We develop a plasma generation method for high-density, large-diameter plasma by combining the advantages of both hot cathode arc discharge and helicon wave discharge characteristics. The experiment confirmed that hybrid discharges produce a higher-density plasma compared to standalone arc discharges or helicon wave discharges across a wide range of gas pressures. Additionally, the diameter of the plasma was found to be twice as large as that of arc discharges alone. The mechanisms behind hybrid discharge and potential performance improvements are discussed.
- Open Access
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Behavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- 1 December 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (12)
Open AccessBehavior of detached simulation plasma by suddenly changed particle flux in GAMMA 10/PDX
Plasma detachment is one of the most significant factors affecting nuclear fusion reactors. GAMMA 10/PDX has a divertor simulation experimental module (D-module) for detached plasma studies in the end region. To investigate the effect of suddenly changing the higher-density particle flux into the detached plasma condition, similar to edge-localized mode simulations, we performed supersonic molecular beam injection (SMBI) and electron cyclotron heating (ECH) experiments to produce a higher-density and higher-temperature core plasma and introduced it to the divertor simulation plasma in the D-module. With the application of ECH, the detached plasma moved to the attached condition. Moreover, with the injection of SMBI into the ECH-injected plasma, the attached plasma moved to a detached condition. This study revealed the effect of sudden changes in the particle flux on detached simulation plasma for the first time.
- Open Access
- 1 August 2024
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 90 (4) , 975900401
Effect of the magnetic field strength on the argon plasma characteristics of a helicon plasma source with a two-turn flat-loop antenna
New plasma applications in advanced fields, such as fundamental nuclear fusion research, require high-density, large-diameter plasma with a strong and non-uniform magnetic field. A helicon plasma (HP) source using a flat-type antenna is expected to be one of the promising methods for such applications. In this study, we developed an HP source with a two-turn flat-loop antenna connected to a 30 kW radio frequency power supply in the Compact Test Plasma device. In the argon plasma generation experiment with various magnetic fields, HP generation was observed for the first time in this device. The electron density was calculated from the dispersion relation with the magnetic field strength at 45 cm from the antenna surface, assuming a fundamental radial mode and an azimuthal mode of $m=0$ . The electron density expected from the experimental result was approximately in the same range as the calculation result by a factor of 2.3 to 3.5. In addition, the magnetic field strength and shape around the antenna are important factors in the plasma properties. This plasma source has been installed in the pilot GAMMA PDX-SC, which is under development for nuclear plasma research, and it contributes to the study of the HP generation process.- 1 August 2024
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 90 (4) , 975900401
Open AccessEffect of the magnetic field strength on the argon plasma characteristics of a helicon plasma source with a two-turn flat-loop antenna
New plasma applications in advanced fields, such as fundamental nuclear fusion research, require high-density, large-diameter plasma with a strong and non-uniform magnetic field. A helicon plasma (HP) source using a flat-type antenna is expected to be one of the promising methods for such applications. In this study, we developed an HP source with a two-turn flat-loop antenna connected to a 30 kW radio frequency power supply in the Compact Test Plasma device. In the argon plasma generation experiment with various magnetic fields, HP generation was observed for the first time in this device. The electron density was calculated from the dispersion relation with the magnetic field strength at 45 cm from the antenna surface, assuming a fundamental radial mode and an azimuthal mode of $m=0$ . The electron density expected from the experimental result was approximately in the same range as the calculation result by a factor of 2.3 to 3.5. In addition, the magnetic field strength and shape around the antenna are important factors in the plasma properties. This plasma source has been installed in the pilot GAMMA PDX-SC, which is under development for nuclear plasma research, and it contributes to the study of the HP generation process. - 5 April 2024
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 90 (2) , 905900208
Study of the pellet ablation cloud using the tomography technique for two-directional simultaneous photography in GAMMA 10/PDX
The pellet ablation mechanism is an interesting subject for plasma fuelling in fusion plasmas. In GAMMA 10/PDX, pellet injection experiments for higher density plasma production are planned to conduct detached plasma experiments in the higher density plasma condition. We measured the pellet ablation cloud by using the two-directional simultaneous photography system in GAMMA 10/PDX. The tomography reconstruction technique was used for considering the pellet trajectory in the plasma and pellet ablation. The three-dimensional pellet trajectory and pellet ablation images in the plasma were clearly obtained for the first time, to the best of our knowledge.
- 5 April 2024
- Published by Cambridge University Press (CUP) in Journal of Plasma Physics
- Vol. 90 (2) , 905900208
Study of the pellet ablation cloud using the tomography technique for two-directional simultaneous photography in GAMMA 10/PDX
The pellet ablation mechanism is an interesting subject for plasma fuelling in fusion plasmas. In GAMMA 10/PDX, pellet injection experiments for higher density plasma production are planned to conduct detached plasma experiments in the higher density plasma condition. We measured the pellet ablation cloud by using the two-directional simultaneous photography system in GAMMA 10/PDX. The tomography reconstruction technique was used for considering the pellet trajectory in the plasma and pellet ablation. The three-dimensional pellet trajectory and pellet ablation images in the plasma were clearly obtained for the first time, to the best of our knowledge.
- 1 March 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (3) , 032501
Study of the intermittent plasma structure around the divertor simulation experimental module in GAMMA 10/PDX
We have investigated the generation region of intermittent plasma structures, which could be due to the blob-like cross field transport around the divertor simulation experimental module (D-module) in the tandem mirror device GAMMA 10/PDX. A positive skewness of the ion saturation current was clearly seen when the electrode of the movable probe was located at the radial edge and just in front of the entrance limiter of the D-module. Fourier analysis and conditional averaging clarified that positive spikes intermittently appeared in the same region. This is the first indication that the phenomenon producing the high-density isolated plasma structures occurred in the upstream of the D-module. A negative skewness was also found, and large amplitude fluctuation was detected between regions showing positive and negative skewness. Furthermore, this and light emission fluctuations become stronger during the transient state from attached to detached state on the V-shaped target.
- 1 March 2023
- Published by AIP Publishing in Physics of Plasmas
- Vol. 30 (3) , 032501
Study of the intermittent plasma structure around the divertor simulation experimental module in GAMMA 10/PDX
We have investigated the generation region of intermittent plasma structures, which could be due to the blob-like cross field transport around the divertor simulation experimental module (D-module) in the tandem mirror device GAMMA 10/PDX. A positive skewness of the ion saturation current was clearly seen when the electrode of the movable probe was located at the radial edge and just in front of the entrance limiter of the D-module. Fourier analysis and conditional averaging clarified that positive spikes intermittently appeared in the same region. This is the first indication that the phenomenon producing the high-density isolated plasma structures occurred in the upstream of the D-module. A negative skewness was also found, and large amplitude fluctuation was detected between regions showing positive and negative skewness. Furthermore, this and light emission fluctuations become stronger during the transient state from attached to detached state on the V-shaped target.
- Open Access
- 21 October 2022
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 33
Evaluation of deuterium recycling properties by fueling termination in the EAST superconducting tokamak
- 21 October 2022
- Published by Elsevier in Nuclear Materials and Energy
- Vol. 33
Open AccessEvaluation of deuterium recycling properties by fueling termination in the EAST superconducting tokamak
- Open Access
- 14 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Cytotoxic CD8+ T cells may be drivers of tissue destruction in Sjögren’s syndrome
Sjögren’s syndrome is a chronic autoimmune disorder whose pathogenesis is poorly understood and that lacks effective therapies. Detailed quantitative and spatial analyses of tissues affected by Sjögren’s syndrome were undertaken, including the quantitation of the frequency of selected cell–cell interactions in the disease milieu. Quantitative analyses of CD4+T cell subsets and of CD8+T cells in the labial salivary glands from untreated patients with primary Sjögren’s syndrome revealed that activated CD8+cytotoxic T cells (CD8+CTLs) were the most prominent T cells in these infiltrates. An accumulation of apoptotic glandular epithelial cells, mainly ductal and acinar cells, was observed, consistent with the impaired salivary secretion often observed in patients with this disease. FasL expressing activated CD8+T cells were seen to accumulate around Fas expressing apoptotic epithelial cells. Quantitative analyses of apoptotic cell types and of conjugates between cytotoxic T cells and epithelial cells undergoing apoptosis suggest that Sjögren’s syndrome is primarily driven by CD8+CTL mediated execution of epithelial cells mainly represented by ductal and acinar cells.
- 14 September 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-11
Open AccessCytotoxic CD8+ T cells may be drivers of tissue destruction in Sjögren’s syndrome
Sjögren’s syndrome is a chronic autoimmune disorder whose pathogenesis is poorly understood and that lacks effective therapies. Detailed quantitative and spatial analyses of tissues affected by Sjögren’s syndrome were undertaken, including the quantitation of the frequency of selected cell–cell interactions in the disease milieu. Quantitative analyses of CD4+T cell subsets and of CD8+T cells in the labial salivary glands from untreated patients with primary Sjögren’s syndrome revealed that activated CD8+cytotoxic T cells (CD8+CTLs) were the most prominent T cells in these infiltrates. An accumulation of apoptotic glandular epithelial cells, mainly ductal and acinar cells, was observed, consistent with the impaired salivary secretion often observed in patients with this disease. FasL expressing activated CD8+T cells were seen to accumulate around Fas expressing apoptotic epithelial cells. Quantitative analyses of apoptotic cell types and of conjugates between cytotoxic T cells and epithelial cells undergoing apoptosis suggest that Sjögren’s syndrome is primarily driven by CD8+CTL mediated execution of epithelial cells mainly represented by ductal and acinar cells.