Divya Baskaran
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Divya Baskaran has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Kavitha Arunachalam
Indian Institute of Technology Madras
4 shared publications AliArshad Kothawala
Indian Institute of Technology Madras,Chennai,India
1 shared publication- Arun Kumar Thittai
Biomedical Ultrasound Imaging Laboratory, Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras, Chennai, India
1 shared publication - Belinda Ding
Siemens Healthcare Ltd Camberley UK
1 shared publication David Andrew Porter
Imaging Centre of Excellence University of Glasgow Glasgow UK
1 shared publicationKeith Muir
Imaging Centre of Excellence University of Glasgow Glasgow UK
1 shared publication
Latest Publications
- Open Access
- 29 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 386-400
Simultaneous whole‐brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8‐channel transceiver array and 56‐channel receiver array
Purpose: To develop a 7T neurovascular head and neck (NVHN) coil with an extended longitudinal coverage of the brain and cervical spine, with eight transceiver (TxRx) channels and 56 receive (Rx) channels for dynamic parallel‐transmit (pTx) applications. Methods: A dual‐row transceiver array with six elements in the upper row and two elements in the lower row was designed using combined electromagnetic and circuit optimization and constructed. A 56Rx array covering the brain and cervical spine was designed and combined with the transceiver array. The performance of the 8TxRx56Rx NVHN coil such as , signal‐to‐noise ratio, and g‐factor were validated in phantom and in vivo studies and compared with an in‐house 8Tx64Rx head coil. High‐resolution in vivo images were acquired with the NVHN and head coil. Results: The average in phantom while exciting the upper six channels and all eight channels are 43.45 nT/V and 45.80 nT/V, respectively, demonstrating that the available field is seamlessly distributed in the brain and/or cervical spine, depending on the chosen excitation. The 8TxRx56Rx NVHN coil increases the SNR in the cervical spine and central brain by a factor of 2.18 and 1.16, respectively, compared with the 8Tx64Rx head coil. Furthermore, it demonstrates similar 1/g‐factor performance for acceleration factors up to 5 × 5 compared with the head coil and provides diagnostic‐quality images of the brain and spinal cord in a single acquisition. Conclusion: The extended longitudinal coverage of the NVHN coil promises to improve the clinical application of the current generation of pTx 7T MRI systems with 8Tx channels.
- 29 January 2025
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 94 (1) , 386-400
Open AccessSimultaneous whole‐brain and cervical spine imaging at 7 T using a neurovascular head and neck coil with 8‐channel transceiver array and 56‐channel receiver array
Purpose: To develop a 7T neurovascular head and neck (NVHN) coil with an extended longitudinal coverage of the brain and cervical spine, with eight transceiver (TxRx) channels and 56 receive (Rx) channels for dynamic parallel‐transmit (pTx) applications. Methods: A dual‐row transceiver array with six elements in the upper row and two elements in the lower row was designed using combined electromagnetic and circuit optimization and constructed. A 56Rx array covering the brain and cervical spine was designed and combined with the transceiver array. The performance of the 8TxRx56Rx NVHN coil such as , signal‐to‐noise ratio, and g‐factor were validated in phantom and in vivo studies and compared with an in‐house 8Tx64Rx head coil. High‐resolution in vivo images were acquired with the NVHN and head coil. Results: The average in phantom while exciting the upper six channels and all eight channels are 43.45 nT/V and 45.80 nT/V, respectively, demonstrating that the available field is seamlessly distributed in the brain and/or cervical spine, depending on the chosen excitation. The 8TxRx56Rx NVHN coil increases the SNR in the cervical spine and central brain by a factor of 2.18 and 1.16, respectively, compared with the 8Tx64Rx head coil. Furthermore, it demonstrates similar 1/g‐factor performance for acceleration factors up to 5 × 5 compared with the head coil and provides diagnostic‐quality images of the brain and spinal cord in a single acquisition. Conclusion: The extended longitudinal coverage of the NVHN coil promises to improve the clinical application of the current generation of pTx 7T MRI systems with 8Tx channels.
- 30 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (1) , 32-38
Implementation of Thinned Array Synthesis in Hyperthermia Treatment Planning of 434 MHz Phased Array Breast Applicator Using Genetic Algorithm
Genetic algorithm-based array thinning technique is investigated in this paper to study the performance of our 18-element 434 MHz phased array breast applicator when driven by reduced number of active antennas. Selective power deposition ability was assessed for 18, 15, 12, and 9 active antennas on 25 patient models with varying characteristics. The average hotspot to target quotient of 18-, 15-, 12-, and 9-antenna excitation in 25 patient models was 1.18, 1.09, 1.09, and 1.13, respectively. The average temperature in 50% tumor volume for 18-, 15-, 12-, and 9-antenna excitation was 42.42 °C, 42.48 °C, 42.49 °C, and 42.48 °C, respectively. The temperature induced in tumor and healthy tissues is similar for varying number of active channels. However, the amount of power consumed was 25.2%, 53.9%, 97.9% higher for 15, 12, 9 active antennas compared to the filled array. Antenna array with 12 active elements was chosen as the optimal combination as it provided selective tumor heating with good tradeoff between number of channels and power consumption. The heating ability of the thinned array was assessed for 50% reduction in the number of active antennas on patient derived heterogeneous breast phantoms for five tumor target locations. The good agreement between simulated and measured thermal distributions demonstrate the selective heating ability of our phased array applicator for 50% reduction in hardware resources. The study outcome enables us to realize a cost-effective hyperthermia treatment delivery system.
- 30 November 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 7 (1) , 32-38
Implementation of Thinned Array Synthesis in Hyperthermia Treatment Planning of 434 MHz Phased Array Breast Applicator Using Genetic Algorithm
Genetic algorithm-based array thinning technique is investigated in this paper to study the performance of our 18-element 434 MHz phased array breast applicator when driven by reduced number of active antennas. Selective power deposition ability was assessed for 18, 15, 12, and 9 active antennas on 25 patient models with varying characteristics. The average hotspot to target quotient of 18-, 15-, 12-, and 9-antenna excitation in 25 patient models was 1.18, 1.09, 1.09, and 1.13, respectively. The average temperature in 50% tumor volume for 18-, 15-, 12-, and 9-antenna excitation was 42.42 °C, 42.48 °C, 42.49 °C, and 42.48 °C, respectively. The temperature induced in tumor and healthy tissues is similar for varying number of active channels. However, the amount of power consumed was 25.2%, 53.9%, 97.9% higher for 15, 12, 9 active antennas compared to the filled array. Antenna array with 12 active elements was chosen as the optimal combination as it provided selective tumor heating with good tradeoff between number of channels and power consumption. The heating ability of the thinned array was assessed for 50% reduction in the number of active antennas on patient derived heterogeneous breast phantoms for five tumor target locations. The good agreement between simulated and measured thermal distributions demonstrate the selective heating ability of our phased array applicator for 50% reduction in hardware resources. The study outcome enables us to realize a cost-effective hyperthermia treatment delivery system.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (1) , 622-630
Multiobjective Optimization of Microwave Phased Array Excitation for Targeted Tissue Heating With Reduced Channel Power in Hyperthermia Treatment Planning
The multiobjective genetic algorithm (MOGA) is proposed for determining phased array (PA) excitation to selectively heat the tumor with minimal healthy tissue hotspot. Power absorption indicators, such as mean specific absorption rate (SAR) in tumor target (SAR targ ), hotspot to tumor quotient (HTQ), average power absorption ratio (aPA ratio), and 50% iso-SAR tumor coverage (TC 50 ), were combined in pairs as an objective function in MOGA. Coupled electromagnetic (EM) and thermal simulations of the heterogeneous breast with locally advanced breast cancer (LABC) were used for evaluating MOGA and single-objective GA (SOGA)-based treatment plans; 25 LABC patient models with varying breast (144.66–1339.3 cc) and tumor (10.53–88.88 cc) volumes and tumor location were employed. The treatment plans were assessed using aforementioned SAR indicators, steady-state thermal metrics in tumors, healthy tissue hotspots in the hyperthermia range (40 °C–44 °C), and channel power consumption of the PA. Among the treatment plans, MOGA with [1/SAR targ , HTQ] obj yielded 104.63% rise in SAR targ across patients with thermal metrics comparable to SOGA with HTQ obj [state of the art (SoA)]. MOGA with [1/SAR targ , HTQ] obj required only 50.5% channel power compared to the SoA, as the tumor was efficiently heated without wasting power in the healthy tissues. This is a significant contribution to developing an affordable PA system.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 70 (1) , 622-630
Multiobjective Optimization of Microwave Phased Array Excitation for Targeted Tissue Heating With Reduced Channel Power in Hyperthermia Treatment Planning
The multiobjective genetic algorithm (MOGA) is proposed for determining phased array (PA) excitation to selectively heat the tumor with minimal healthy tissue hotspot. Power absorption indicators, such as mean specific absorption rate (SAR) in tumor target (SAR targ ), hotspot to tumor quotient (HTQ), average power absorption ratio (aPA ratio), and 50% iso-SAR tumor coverage (TC 50 ), were combined in pairs as an objective function in MOGA. Coupled electromagnetic (EM) and thermal simulations of the heterogeneous breast with locally advanced breast cancer (LABC) were used for evaluating MOGA and single-objective GA (SOGA)-based treatment plans; 25 LABC patient models with varying breast (144.66–1339.3 cc) and tumor (10.53–88.88 cc) volumes and tumor location were employed. The treatment plans were assessed using aforementioned SAR indicators, steady-state thermal metrics in tumors, healthy tissue hotspots in the hyperthermia range (40 °C–44 °C), and channel power consumption of the PA. Among the treatment plans, MOGA with [1/SAR targ , HTQ] obj yielded 104.63% rise in SAR targ across patients with thermal metrics comparable to SOGA with HTQ obj [state of the art (SoA)]. MOGA with [1/SAR targ , HTQ] obj required only 50.5% channel power compared to the SoA, as the tumor was efficiently heated without wasting power in the healthy tissues. This is a significant contribution to developing an affordable PA system.
- 19 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (3) , 1706-1715
Design and Experimental Verification of 434 MHz Phased Array Applicator for Hyperthermia Treatment of Locally Advanced Breast Cancer
Design and experimental verification of a phased array (PA) of 434 MHz water-loaded cavity-backed patch antennas is presented for hyperthermia treatment (HT) of locally advanced breast cancer (LABC). A staggered annular array of 18 antennas distributed across three rings with 6 antennas per ring and 40 mm ring spacing is presented for HT. The applicator performance is assessed on three layered breast models of varying volumes (105 – 1025 cm3) with 64 cm3 tumor target at three different locations in the individual breast model, and an anatomically realistic patient model with LABC (46 cm3) in the upper outer quadrant. HT indicators for the optimized applicator indicated average power absorption ratio (αPAratio) ≥ 3.93 and 10.48, and hotspot to target quotient (HTQ) ≤ 1.34 and 1.08 in the large and small breast models, respectively. αPAratio and HTQ was 6.14 and 1.23 in the anatomically realistic model, respectively. Simulation results were experimentally verified on a 3D phantom fabricated based on the patient model with thermo-dielectric properties of breast tissues. Temperature rise of 6.04 °C, 6.55 °C, and 5.5 °C measured for centered and two off-centered tumor locations in the phantom for 20 min heating, respectively were in excellent agreement with the simulations without any significant healthy tissue hotspots.
- 19 August 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Antennas and Propagation
- Vol. 69 (3) , 1706-1715
Design and Experimental Verification of 434 MHz Phased Array Applicator for Hyperthermia Treatment of Locally Advanced Breast Cancer
Design and experimental verification of a phased array (PA) of 434 MHz water-loaded cavity-backed patch antennas is presented for hyperthermia treatment (HT) of locally advanced breast cancer (LABC). A staggered annular array of 18 antennas distributed across three rings with 6 antennas per ring and 40 mm ring spacing is presented for HT. The applicator performance is assessed on three layered breast models of varying volumes (105 – 1025 cm3) with 64 cm3 tumor target at three different locations in the individual breast model, and an anatomically realistic patient model with LABC (46 cm3) in the upper outer quadrant. HT indicators for the optimized applicator indicated average power absorption ratio (αPAratio) ≥ 3.93 and 10.48, and hotspot to target quotient (HTQ) ≤ 1.34 and 1.08 in the large and small breast models, respectively. αPAratio and HTQ was 6.14 and 1.23 in the anatomically realistic model, respectively. Simulation results were experimentally verified on a 3D phantom fabricated based on the patient model with thermo-dielectric properties of breast tissues. Temperature rise of 6.04 °C, 6.55 °C, and 5.5 °C measured for centered and two off-centered tumor locations in the phantom for 20 min heating, respectively were in excellent agreement with the simulations without any significant healthy tissue hotspots.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 321-324
Regularized Kurtosis Imaging and its Comparison with Regularized Log Spectral Difference and Regularized Nakagami Imaging for Microwave Hyperthermia Hotspot Monitoring
Microwave hyperthermia makes use of microwaves to deliver heat to biological tissues. Real time temperature monitoring during treatment is important for efficacy and effectiveness of the treatment. Non-invasive methods such as CT, MR and ultrasound (US) have been actively researched for use in hyperthermia monitoring. US has inherent advantages of real-time imaging, portability and non-ionizing nature. It is also known from the literature that acoustic properties of tissue are sensitive to temperature and this has been harnessed to track the evolution of hotspot and temperature in high temperature zones encountered in ablation treatments. However, their usage in low temperature zones typically observed in hyperthermia appears to be less explored. This study introduces an improved method of regularized Kurtosis imaging (RKI) and compares its performance against regularized log spectral difference (RLSD) and regularized Nakagami imaging methods. The performance of these methods is compared against the ground truth estimated from IR thermal images in an experimental study on tissue-mimicking PAG-agar based phantoms. The error in the area estimated by RKI was 10.6%. The error in the lateral and axial co-ordinate of the centroid was 5.92% and 0.47%, respectively. The structural similarity index was 0.82 for RKI when compared with RLSD and RNI having score of 0.76 and 0.72, respectively. The results are promising and offer an alternative way to track the hotspot during microwave hyperthermia treatment.
- 1 April 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 321-324
Regularized Kurtosis Imaging and its Comparison with Regularized Log Spectral Difference and Regularized Nakagami Imaging for Microwave Hyperthermia Hotspot Monitoring
Microwave hyperthermia makes use of microwaves to deliver heat to biological tissues. Real time temperature monitoring during treatment is important for efficacy and effectiveness of the treatment. Non-invasive methods such as CT, MR and ultrasound (US) have been actively researched for use in hyperthermia monitoring. US has inherent advantages of real-time imaging, portability and non-ionizing nature. It is also known from the literature that acoustic properties of tissue are sensitive to temperature and this has been harnessed to track the evolution of hotspot and temperature in high temperature zones encountered in ablation treatments. However, their usage in low temperature zones typically observed in hyperthermia appears to be less explored. This study introduces an improved method of regularized Kurtosis imaging (RKI) and compares its performance against regularized log spectral difference (RLSD) and regularized Nakagami imaging methods. The performance of these methods is compared against the ground truth estimated from IR thermal images in an experimental study on tissue-mimicking PAG-agar based phantoms. The error in the area estimated by RKI was 10.6%. The error in the lateral and axial co-ordinate of the centroid was 5.92% and 0.47%, respectively. The structural similarity index was 0.82 for RKI when compared with RLSD and RNI having score of 0.76 and 0.72, respectively. The results are promising and offer an alternative way to track the hotspot during microwave hyperthermia treatment.
- 22 October 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 67 (1) , 49-59
Breast Tissue Tumor Analysis Using Wideband Antenna and Microwave Scattering
This paper proposes a simple and computationally efficient algorithm for the detection and localization of early tumors (<5 mm) in the breast tissues. The feasibility of the proposed technique is demonstrated with three-dimensional EM simulators and validated with experimental results on a breast phantom using wideband patch antenna operating in 2.4–4.7 GHz band. The proposed method identifies the tumor location and the depth of the tumor. This is accomplished by employing a mean value approach and an efficient algorithm. Average value of the backscattered signal received by the antenna at different location is considered in the mean value technique. The depth of tumor is identified by Ground Penetrating Radar algorithm which employs the backscattered signals from the breast tissues. These data are converted to B-scan image which in turn gives the depth of the tumor. The results obtained in the experiment are in congruence with the simulated results. In the experimental analysis, the tumor location is identified when the size of the tumor is large owing to the low sensitivity of the antenna.
- 22 October 2018
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 67 (1) , 49-59
Breast Tissue Tumor Analysis Using Wideband Antenna and Microwave Scattering
This paper proposes a simple and computationally efficient algorithm for the detection and localization of early tumors (<5 mm) in the breast tissues. The feasibility of the proposed technique is demonstrated with three-dimensional EM simulators and validated with experimental results on a breast phantom using wideband patch antenna operating in 2.4–4.7 GHz band. The proposed method identifies the tumor location and the depth of the tumor. This is accomplished by employing a mean value approach and an efficient algorithm. Average value of the backscattered signal received by the antenna at different location is considered in the mean value technique. The depth of tumor is identified by Ground Penetrating Radar algorithm which employs the backscattered signals from the breast tissues. These data are converted to B-scan image which in turn gives the depth of the tumor. The results obtained in the experiment are in congruence with the simulated results. In the experimental analysis, the tumor location is identified when the size of the tumor is large owing to the low sensitivity of the antenna.