Marcin Zmuda Trzebiatowski
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Marcin Zmuda Trzebiatowski has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Andrzej Skorek
Med Univ Gdansk, Dept Otolaryngol, Gdansk, Poland
6 shared publications - Paweł Kłosowski
Politechnika Gdańska, Wydział Inżynierii Lądowej i Środowiska
5 shared publications - Krzysztof Zerdzicki
Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, 80-233 Gdansk, Poland
3 shared publications - Paweł Lemski
Med Univ Gdansk, Dept Otolaryngol, Gdansk, Poland
3 shared publications - Mateusz Koberda
Med Univ Gdansk, Dept Ophthalmol, Gdansk, Poland
2 shared publications Paweł Lemski
Department of Otolaryngology, Medical University of Gdańsk, Gdańsk, Poland
2 shared publications
Latest Publications
- 30 November 2025
- Published by Index Copernicus in BUILDER
- Vol. 341 (12) , 28-35
Model numeryczny i fizyczny dwudziestościanu foremnego tensegrity wykonanego z prętów i tkaniny technicznej
W niniejszej pracy omówiono problemy projektowania i wykonania prototypowej prętowo-membranowej konstrukcji tensegrity ze szczególnym uwzględnieniem kształtowania węzłów prętowo-membranowych oraz sposobów łączenia ze sobą fragmentów tkaniny technicznej. Omówiono krok po kroku proces projektowania konstrukcji. Opisano badania laboratoryjne planowanych do wykorzystania materiałów, zaprojektowanych połączeń elementów, a także te obejmujące projektowaną konstrukcję tensegrity. Przedstawiono również wyniki symulacji numerycznych uproszczonego modelu przestrzennego prętowo-membranowego niniejszej konstrukcji, stanowiącego pierwszy krok do przeprowadzenia dalszych analiz, bardziej złożonych analiz, w szczególności dokładniejszego modelowania połączeń prętowo-membranowych. W szczególności, w ramach niniejszej pracy, przeprowadzono laboratoryjne testy jedno- i dwuosiowe dwóch tkanin technicznych w celu wyznaczenia parametrów wytrzymałościowych, jak również przebadano laboratoryjnie wybrane rodzaje połączeń typu tkanina–tkanina: zgrzewane, klejone, szyte, jak równie połączenia tkanina–pręt wykonane z wykorzystaniem metalowych oczek w celu oszacowania nośności takich połączeń. Przystąpiono do budowy wstępnych modeli skończenie elementowych mających odwzorować próby jedno- i dwuosiowe dla obu tkanin technicznych. Model docelowej konstrukcji tensegrity zaprojektowano jako wyidealizowany (uproszczony) układ prętowo-membranowy w postaci dwudziestościanu foremnego. Przystąpiono do budowy rzeczywistego modelu konstrukcji tensegrity możliwego do przebadania w warunkach laboratoryjnych, w szczególności poprzez przeprowadzenie badań z wykorzystaniem aparatury Digital Image Correlation (DIC). Uzyskane w ten sposób wyniki w postaci map odkształceń zestawiono z analogicznymi wynikami dla modelu numerycznego konstrukcji prototypowej. Na etapie kalibracji modeli laboratoryjnych próbek w testach jedno- i dwuosiowych uzyskano satysfakcjonującą zbieżność pomiędzy rezultatami badań laboratoryjnych i symulacji numerycznych, co zostało opisane w odrębnych pozycjach bibliograficznych. W kontekście modelu rzeczywistego tensegrity i jego numerycznego odpowiednika można zauważyć pewne podobieństwa, natomiast sam model numeryczny wymaga dalszego rozwoju, gdyż zastosowane w nim uproszczenia (wyidealizowana geometria nieuwzględniająca imperfekcji) mogą być zbyt daleko idące. Niemniej pomierzone mapy odkształceń pokrywają się ze zidentyfikowanymi numerycznie strefami ekstremalnych odkształceń, układając się w charakterystyczne trajektorie i strefy. Zaprezentowany w ramach niniejszej pracy model numeryczny odwzorowujący rzeczywisty układ tensegrity w toku dalszych prac zostanie ulepszony, by jak najwierniej odwzorowywał rzeczywisty układ.
- 30 November 2025
- Published by Index Copernicus in BUILDER
- Vol. 341 (12) , 28-35
Model numeryczny i fizyczny dwudziestościanu foremnego tensegrity wykonanego z prętów i tkaniny technicznej
W niniejszej pracy omówiono problemy projektowania i wykonania prototypowej prętowo-membranowej konstrukcji tensegrity ze szczególnym uwzględnieniem kształtowania węzłów prętowo-membranowych oraz sposobów łączenia ze sobą fragmentów tkaniny technicznej. Omówiono krok po kroku proces projektowania konstrukcji. Opisano badania laboratoryjne planowanych do wykorzystania materiałów, zaprojektowanych połączeń elementów, a także te obejmujące projektowaną konstrukcję tensegrity. Przedstawiono również wyniki symulacji numerycznych uproszczonego modelu przestrzennego prętowo-membranowego niniejszej konstrukcji, stanowiącego pierwszy krok do przeprowadzenia dalszych analiz, bardziej złożonych analiz, w szczególności dokładniejszego modelowania połączeń prętowo-membranowych. W szczególności, w ramach niniejszej pracy, przeprowadzono laboratoryjne testy jedno- i dwuosiowe dwóch tkanin technicznych w celu wyznaczenia parametrów wytrzymałościowych, jak również przebadano laboratoryjnie wybrane rodzaje połączeń typu tkanina–tkanina: zgrzewane, klejone, szyte, jak równie połączenia tkanina–pręt wykonane z wykorzystaniem metalowych oczek w celu oszacowania nośności takich połączeń. Przystąpiono do budowy wstępnych modeli skończenie elementowych mających odwzorować próby jedno- i dwuosiowe dla obu tkanin technicznych. Model docelowej konstrukcji tensegrity zaprojektowano jako wyidealizowany (uproszczony) układ prętowo-membranowy w postaci dwudziestościanu foremnego. Przystąpiono do budowy rzeczywistego modelu konstrukcji tensegrity możliwego do przebadania w warunkach laboratoryjnych, w szczególności poprzez przeprowadzenie badań z wykorzystaniem aparatury Digital Image Correlation (DIC). Uzyskane w ten sposób wyniki w postaci map odkształceń zestawiono z analogicznymi wynikami dla modelu numerycznego konstrukcji prototypowej. Na etapie kalibracji modeli laboratoryjnych próbek w testach jedno- i dwuosiowych uzyskano satysfakcjonującą zbieżność pomiędzy rezultatami badań laboratoryjnych i symulacji numerycznych, co zostało opisane w odrębnych pozycjach bibliograficznych. W kontekście modelu rzeczywistego tensegrity i jego numerycznego odpowiednika można zauważyć pewne podobieństwa, natomiast sam model numeryczny wymaga dalszego rozwoju, gdyż zastosowane w nim uproszczenia (wyidealizowana geometria nieuwzględniająca imperfekcji) mogą być zbyt daleko idące. Niemniej pomierzone mapy odkształceń pokrywają się ze zidentyfikowanymi numerycznie strefami ekstremalnych odkształceń, układając się w charakterystyczne trajektorie i strefy. Zaprezentowany w ramach niniejszej pracy model numeryczny odwzorowujący rzeczywisty układ tensegrity w toku dalszych prac zostanie ulepszony, by jak najwierniej odwzorowywał rzeczywisty układ.
- Open Access
- 18 May 2023
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 36 (2) , 263-273
Numerical and clinical analysis of an eyeball injuries under direct impact
Objectives: The objective of this study was to develop a numerical model of the eyeball and orbit to simulate a blunt injury to the eyeball leading to its rupture, as well as to conduct a comparative analysis of the results obtained using the finite element method against the clinical material...
- 18 May 2023
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 36 (2) , 263-273
Open AccessNumerical and clinical analysis of an eyeball injuries under direct impact
Objectives: The objective of this study was to develop a numerical model of the eyeball and orbit to simulate a blunt injury to the eyeball leading to its rupture, as well as to conduct a comparative analysis of the results obtained using the finite element method against the clinical material...
- Open Access
- 4 March 2021
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2021, 1-12
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
The more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanisms veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanisms theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model of the orbit were performed. The intraorbital hydraulic pressure was introduced as a face load applied directly to the orbit in the first variant, while in the second one the load was applied to the orbit indirectly as a set of nodal forces transferred from the external surface of the eyeball via the intraorbital tissues to the orbital walls within the contact problem. Such an approach is aimed at a better understanding of the pattern for the formation of blowout fractures during the indirect load applied to the orbital bones. The nonlinear dynamic analysis of both numerical models showed that the potential fracture was observed in the second variant only, embracing a relatively large area: both medial and lower wall of the orbit. Interestingly, the pressure generated by the intraorbital entities transferred the energy of the impact to the orbital sidewalls mainly; thus, the nature of the mechanism known as the hydraulic was far from the expected hydraulic pressure. According to the eyeballs deformation as well as the areas of the greatest Huber-Mises-Hencky (H-M-H) stress within the orbit, a new term of strut mechanism was proposed instead of the hydraulic mechanism as more realistic regarding the investigated phenomenon. The results of the current research may strongly influence the development of modern implantology as well as affect forensic medicine.
- 4 March 2021
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2021, 1-12
Open AccessValidation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
The more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanisms veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanisms theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model of the orbit were performed. The intraorbital hydraulic pressure was introduced as a face load applied directly to the orbit in the first variant, while in the second one the load was applied to the orbit indirectly as a set of nodal forces transferred from the external surface of the eyeball via the intraorbital tissues to the orbital walls within the contact problem. Such an approach is aimed at a better understanding of the pattern for the formation of blowout fractures during the indirect load applied to the orbital bones. The nonlinear dynamic analysis of both numerical models showed that the potential fracture was observed in the second variant only, embracing a relatively large area: both medial and lower wall of the orbit. Interestingly, the pressure generated by the intraorbital entities transferred the energy of the impact to the orbital sidewalls mainly; thus, the nature of the mechanism known as the hydraulic was far from the expected hydraulic pressure. According to the eyeballs deformation as well as the areas of the greatest Huber-Mises-Hencky (H-M-H) stress within the orbit, a new term of strut mechanism was proposed instead of the hydraulic mechanism as more realistic regarding the investigated phenomenon. The results of the current research may strongly influence the development of modern implantology as well as affect forensic medicine.
- 1 November 2020
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 121 (5) , 611-613
Sophistication assessment of existing FEM models of orbital blowout trauma: Is models valuation justified?
- 1 November 2020
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 121 (5) , 611-613
Sophistication assessment of existing FEM models of orbital blowout trauma: Is models valuation justified?
- Open Access
- 17 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-13
Nonlinear dynamic analysis of the pure “buckling” mechanism during blow-out trauma of the human orbit
Considering the interplay between orbital bones and intraorbital soft tissues, commonly accepted patterns of the blow-out type of trauma within the human orbit require more thorough investigation to assess the minimal health-threatening impact value. Two different three-dimensional finite element method (FEM) models of the human orbital region were developed to simulate the pure “buckling” mechanism of orbital wall fracture in two variants: the model of orbital bone elements and the model of orbital bone, orbit and intraorbital tissue elements. The mechanical properties of the so-defined numerical skull fragment were applied to the model according to the unique laboratory tensile stress tests performed on small and fragile specimens of orbital bones as well as using the data available in the literature. The nonlinear transient analysis of the contact problem between bodies that differ substantially in terms of the Young’s modulus was carried out to investigate the interaction of different bodies within an instant injury. Potential damage areas were found within the lower orbital wall as well as the destructive load values for both FEM skull models (7,660 N and 8,520 N). Moreover, numerical simulations were validated by comparing them with computed tomography scans of real injuries.
- 17 September 2020
- Published by Springer Nature in Scientific Reports
- Vol. 10 (1) , 1-13
Open AccessNonlinear dynamic analysis of the pure “buckling” mechanism during blow-out trauma of the human orbit
Considering the interplay between orbital bones and intraorbital soft tissues, commonly accepted patterns of the blow-out type of trauma within the human orbit require more thorough investigation to assess the minimal health-threatening impact value. Two different three-dimensional finite element method (FEM) models of the human orbital region were developed to simulate the pure “buckling” mechanism of orbital wall fracture in two variants: the model of orbital bone elements and the model of orbital bone, orbit and intraorbital tissue elements. The mechanical properties of the so-defined numerical skull fragment were applied to the model according to the unique laboratory tensile stress tests performed on small and fragile specimens of orbital bones as well as using the data available in the literature. The nonlinear transient analysis of the contact problem between bodies that differ substantially in terms of the Young’s modulus was carried out to investigate the interaction of different bodies within an instant injury. Potential damage areas were found within the lower orbital wall as well as the destructive load values for both FEM skull models (7,660 N and 8,520 N). Moreover, numerical simulations were validated by comparing them with computed tomography scans of real injuries.
- Open Access
- 24 June 2020
- Published by Institute of Rural Health in Journal of Pre-Clinical and Clinical Research
- Vol. 14 (2) , 39-43
Orbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
Introduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal...
- 24 June 2020
- Published by Institute of Rural Health in Journal of Pre-Clinical and Clinical Research
- Vol. 14 (2) , 39-43
Open AccessOrbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
Introduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal...
- Open Access
- 16 September 2014
- Published by Wiley in Journal of Ophthalmology
- Vol. 2014, 1-5
Posttraumatic Orbital Emphysema: A Numerical Model
Orbital emphysema is a common symptom accompanying orbital fracture. The pathomechanism is still not recognized and the usually assumed cause, elevated pressure in the upper airways connected with sneezing or coughing, does not always contribute to the occurrence of this type of fracture. Observations based on the finite model (simulating blowout type fracture) of the deformations of the inferior orbital wall after a strike in its lower rim. Authors created a computer numeric model of the orbit with specified features—thickness and resilience modulus. During simulation an evenly spread 14400 N force was applied to the nodular points in the inferior rim (the maximal value not causing cracking of the outer rim, but only ruptures in the inferior wall). The observation was made fromtosecond after a strike. Right after a strike dislocations of the inferior orbital wall toward the maxillary sinus were observed. Afterwards a retrograde wave of the dislocation of the inferior wall toward the orbit was noticed. Overall dislocation amplitude reached about 6 mm. Based on a numeric model of the orbit submitted to a strike in the inferior wall an existence of a retrograde shock wave causing orbital emphysema has been found.- 16 September 2014
- Published by Wiley in Journal of Ophthalmology
- Vol. 2014, 1-5
Open AccessPosttraumatic Orbital Emphysema: A Numerical Model
Orbital emphysema is a common symptom accompanying orbital fracture. The pathomechanism is still not recognized and the usually assumed cause, elevated pressure in the upper airways connected with sneezing or coughing, does not always contribute to the occurrence of this type of fracture. Observations based on the finite model (simulating blowout type fracture) of the deformations of the inferior orbital wall after a strike in its lower rim. Authors created a computer numeric model of the orbit with specified features—thickness and resilience modulus. During simulation an evenly spread 14400 N force was applied to the nodular points in the inferior rim (the maximal value not causing cracking of the outer rim, but only ruptures in the inferior wall). The observation was made fromtosecond after a strike. Right after a strike dislocations of the inferior orbital wall toward the maxillary sinus were observed. Afterwards a retrograde wave of the dislocation of the inferior wall toward the orbit was noticed. Overall dislocation amplitude reached about 6 mm. Based on a numeric model of the orbit submitted to a strike in the inferior wall an existence of a retrograde shock wave causing orbital emphysema has been found.