Krzysztof Zerdzicki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Krzysztof Zerdzicki has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Paweł Kłosowski
Politechnika Gdańska, Wydział Inżynierii Lądowej i Środowiska
8 shared publications - Andrzej Skorek
Med Univ Gdansk, Dept Otolaryngol, Gdansk, Poland
3 shared publications Krzysztof Woznica
Laboratoire de Mecanique Gabriel Lame, Institut National des Sciences Appliquees Centre Val de Loire
3 shared publications- Marcin Zmuda Trzebiatowski
Politechnika Gdańska, Wydział Inżynierii Lądowej i Środowiska
3 shared publications - Paweł Lemski
Med Univ Gdansk, Dept Otolaryngol, Gdansk, Poland
3 shared publications - Aleksander Znaczko
Department of Structural Mechanics, Faculty of Civil and Environmental Engineering, Gdansk University of Technology, 80-233 Gdansk, Poland
2 shared publications
Latest Publications
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Durability evaluation of textile hanging roofs materials
Evaluation de la durabilité de texrtiles techniques de toits suspendus: L’objet de ce travail est l’évaluation du processus de vieillissement et de la durabilité des tissus techniques utilisés en ingénierie de construction. Deux types de tissu en polyester enduit de PVC ont été testés: VALMEX vieilli naturellement et AF9032 soumis au vieillissement accéléré. L'impact du processus de vieillissement a été observé en analysant les changements des valeurs des paramètres des modèles constitutifs: linéaire par morceaux, viscoélastique de Burgers et viscoplastique de Bodner-Partom. La comparaison de tissu VALMEX utilisé pendant 20 ans à l’Opéra de la Forêt à Sopot et du même tissu stocké à l’abri a montré que la matière, après 20 années de fonctionnement, a conservé ses propriétés mécaniques et pourrait être encore utilisée pendant plusieurs années. Le vieillissement dû aux conditions environnementales d’exploitation a provoqué une augmentation de la rigidité du revêtement (PVC), alors que la raideur des fibres en polyester est restée pratiquement inchangée. Le tissu AF9032 a été soumis au processus de vieillissement accéléré. Les échantillons de tissu ont été placés dans une chambre thermique à 80 et 90 °C durant 12 semaines. Les variations des paramètres des modèles constitutifs en fonction de temps de vieillissement ont pu être exprimées par des relations linéaires. Les résultats de vieillissement thermique accéléré ont été extrapolés d’après la méthode d’Arrhenius pour obtenir des valeurs correspondantes au vieillissement naturel. Pour les deux cas de vieillissement, les changements plus importants se sont produits dans la direction de la trame. Pour les fils de chaîne, les différences sont beaucoup plus petites et parfois négligeables.
- 1 April 2026
- Published by Agence Bibliographique de l'Enseignement Supérieur
Durability evaluation of textile hanging roofs materials
Evaluation de la durabilité de texrtiles techniques de toits suspendus: L’objet de ce travail est l’évaluation du processus de vieillissement et de la durabilité des tissus techniques utilisés en ingénierie de construction. Deux types de tissu en polyester enduit de PVC ont été testés: VALMEX vieilli naturellement et AF9032 soumis au vieillissement accéléré. L'impact du processus de vieillissement a été observé en analysant les changements des valeurs des paramètres des modèles constitutifs: linéaire par morceaux, viscoélastique de Burgers et viscoplastique de Bodner-Partom. La comparaison de tissu VALMEX utilisé pendant 20 ans à l’Opéra de la Forêt à Sopot et du même tissu stocké à l’abri a montré que la matière, après 20 années de fonctionnement, a conservé ses propriétés mécaniques et pourrait être encore utilisée pendant plusieurs années. Le vieillissement dû aux conditions environnementales d’exploitation a provoqué une augmentation de la rigidité du revêtement (PVC), alors que la raideur des fibres en polyester est restée pratiquement inchangée. Le tissu AF9032 a été soumis au processus de vieillissement accéléré. Les échantillons de tissu ont été placés dans une chambre thermique à 80 et 90 °C durant 12 semaines. Les variations des paramètres des modèles constitutifs en fonction de temps de vieillissement ont pu être exprimées par des relations linéaires. Les résultats de vieillissement thermique accéléré ont été extrapolés d’après la méthode d’Arrhenius pour obtenir des valeurs correspondantes au vieillissement naturel. Pour les deux cas de vieillissement, les changements plus importants se sont produits dans la direction de la trame. Pour les fils de chaîne, les différences sont beaucoup plus petites et parfois négligeables.
- Open Access
Influence of the Cortical Layer Thickness and Trabecular Layer Pattern Density on 3D-Printed Femur Strength
This paper presents the process of preparing and conducting a uniaxial compression test, developing the results, and determining the compressive strength of a femur made using 3D printing technology. The study considers the variable thickness of the outer layer—imitating cortical bone tissue—and the varying density of the inner layer—imitating trabecular bone tissue—which, with further analysis, may aim to replicate different states of osteoporosis. The compressive strength of the bones varied depending on the thickness of the outer layer and the filling degree. Failure patterns were observed, corresponding to different variants of the produced bones. The predominant failure pattern was the fracture of the femoral head or neck at the proximal end of the femur. The results were compared with previous studies on commercial femur bones, as well as those created using 3D printing technology by other authors. The highest compressive strength was found in the bone with an outer layer thickness of 3.0 mm and 30% infill, with a value of 4778 N. A very similar compressive strength was recorded for the bone with an outer thickness of 2.1 mm and 30% infill, reaching 4519 N. The lowest compressive strength, 2116 N, was observed in the bone with an outer thickness of 1.2 mm and 20% infill.
Open AccessInfluence of the Cortical Layer Thickness and Trabecular Layer Pattern Density on 3D-Printed Femur Strength
This paper presents the process of preparing and conducting a uniaxial compression test, developing the results, and determining the compressive strength of a femur made using 3D printing technology. The study considers the variable thickness of the outer layer—imitating cortical bone tissue—and the varying density of the inner layer—imitating trabecular bone tissue—which, with further analysis, may aim to replicate different states of osteoporosis. The compressive strength of the bones varied depending on the thickness of the outer layer and the filling degree. Failure patterns were observed, corresponding to different variants of the produced bones. The predominant failure pattern was the fracture of the femoral head or neck at the proximal end of the femur. The results were compared with previous studies on commercial femur bones, as well as those created using 3D printing technology by other authors. The highest compressive strength was found in the bone with an outer layer thickness of 3.0 mm and 30% infill, with a value of 4778 N. A very similar compressive strength was recorded for the bone with an outer thickness of 2.1 mm and 30% infill, reaching 4519 N. The lowest compressive strength, 2116 N, was observed in the bone with an outer thickness of 1.2 mm and 20% infill.
- Open Access
- 17 January 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1482165
Compressive and tensile properties of polyurethane foam mimicking trabecular tissue in artificial femoral head bones
Introduction: Most orthopedic implants for fracture fixation and joint replacement are commonly tested on artificial bones. Polyurethane foam is one of the most frequently used synthetic bone materials for mimicking human trabecular tissue. The study aimed to examine the compressive and tensile behavior of polyurethane foams mimicking trabecular tissue in artificial human femurs and assess their potential to replicate the osteoporotic type of human bone tissue.Materials and methods: Two types of SYNBONE femur models, one of normal density (model 2350) and one of lower density (model LD2350), and three types of Sawbones femur models (models 1130-21-8, 1130-21-3, and 1130-192) were investigated. Polyurethane foams were extracted as slices cut in the coronal plane from the femoral head. Cuboid samples were cut in three directions and uniaxial tested to identify compressive and tensile properties, including elastic modulus, Poisson’s ratio, yield limit, and ultimate strength.Results: The ANOVA test revealed that only SYNBONE LD2350 trabecular tissue exhibits anisotropy properties (p < 0.001). In most cases, the tensile properties were greater than compressive ones (t-test, p < 0.001).Conclusion: The obtained results are within the ranges suggested by other authors for mimicking osteoporotic human tissue. The presented data broadens the range of data on mechanical properties provided by the producers. These data can serve as a reference for research using composite femurs made of these particular polyurethane foams for conducting biomechanical studies and validating accompanying numerical simulations.
- 17 January 2025
- Published by Frontiers Media SA in Frontiers in Bioengineering and Biotechnology
- Vol. 12, 1482165
Open AccessCompressive and tensile properties of polyurethane foam mimicking trabecular tissue in artificial femoral head bones
Introduction: Most orthopedic implants for fracture fixation and joint replacement are commonly tested on artificial bones. Polyurethane foam is one of the most frequently used synthetic bone materials for mimicking human trabecular tissue. The study aimed to examine the compressive and tensile behavior of polyurethane foams mimicking trabecular tissue in artificial human femurs and assess their potential to replicate the osteoporotic type of human bone tissue.Materials and methods: Two types of SYNBONE femur models, one of normal density (model 2350) and one of lower density (model LD2350), and three types of Sawbones femur models (models 1130-21-8, 1130-21-3, and 1130-192) were investigated. Polyurethane foams were extracted as slices cut in the coronal plane from the femoral head. Cuboid samples were cut in three directions and uniaxial tested to identify compressive and tensile properties, including elastic modulus, Poisson’s ratio, yield limit, and ultimate strength.Results: The ANOVA test revealed that only SYNBONE LD2350 trabecular tissue exhibits anisotropy properties (p < 0.001). In most cases, the tensile properties were greater than compressive ones (t-test, p < 0.001).Conclusion: The obtained results are within the ranges suggested by other authors for mimicking osteoporotic human tissue. The presented data broadens the range of data on mechanical properties provided by the producers. These data can serve as a reference for research using composite femurs made of these particular polyurethane foams for conducting biomechanical studies and validating accompanying numerical simulations.
- Open Access
- 18 May 2023
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 36 (2) , 263-273
Numerical and clinical analysis of an eyeball injuries under direct impact
Objectives: The objective of this study was to develop a numerical model of the eyeball and orbit to simulate a blunt injury to the eyeball leading to its rupture, as well as to conduct a comparative analysis of the results obtained using the finite element method against the clinical material...
- 18 May 2023
- Published by Nofer Institute of Occupational Medicine in International Journal of Occupational Medicine and Environmental Health
- Vol. 36 (2) , 263-273
Open AccessNumerical and clinical analysis of an eyeball injuries under direct impact
Objectives: The objective of this study was to develop a numerical model of the eyeball and orbit to simulate a blunt injury to the eyeball leading to its rupture, as well as to conduct a comparative analysis of the results obtained using the finite element method against the clinical material...
- 1 January 2023
- Published by Politechnika Wroclawska Oficyna Wydawnicza in Acta of Bioengineering and Biomechanics
- Vol. 25 (3) , 53-60
Tensile and flexural moduli for human orbital wall bones – comparative study
- 1 January 2023
- Published by Politechnika Wroclawska Oficyna Wydawnicza in Acta of Bioengineering and Biomechanics
- Vol. 25 (3) , 53-60
Tensile and flexural moduli for human orbital wall bones – comparative study
- 1 June 2022
- Published by Springer Nature
- p. 233-241
Flexural Modulus of Synthetic Femur Polyurethane Foam Bone Components Based on Three-Point Bending Tests
- 1 June 2022
- Published by Springer Nature
- p. 233-241
Flexural Modulus of Synthetic Femur Polyurethane Foam Bone Components Based on Three-Point Bending Tests
- Open Access
- 5 November 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (11) , e0259363
Tensile modulus of human orbital wall bones cut in sagittal and coronal planes
In the current research, 68 specimens of orbital superior and/or medial walls taken from 33 human cadavers (12 females, 21 males) were subjected to uniaxial tension untill fracture. The samples were cut in the coronal (38 specimens) and sagittal (30 specimens) planes of the orbital wall. Apparent density (ρapp), tensile Young’s modulus (E-modulus) and ultimate tensile strength (UTS) were identified. Innovative test protocols were used to minimize artifacts and analyze the obtained data: (1) grips dedicated to non-symmetrical samples clamping were applied for mechanical testing, (2) non-contact measuring system of video-extensometer was employed for displacement registration, (3) ink imprint technique coupled with CAD analysis was applied to precisely access the cross-sectional areas of tested samples. With regard to a pooled group, apparent density for the coronal and sagittal cut plane was equal 1.53 g/cm3 and 1.57 g/cm3, tensile Young’s modulus 2.36 GPa and 2.14 GPa, and ultimate tensile strength 12.66 MPa and 14.35 MPa, respectively. No significant statistical differences (p > 0.05) were found for all the analyzed parameters when comparing coronal and sagittal plane cut groups. These observations confirmed the hypothesis that direction of sample cut does not affect the mechanical response of the orbital wall tissue, thus suggesting that mechanical properties of orbital wall bone show isotropic character.
- 5 November 2021
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 16 (11) , e0259363
Open AccessTensile modulus of human orbital wall bones cut in sagittal and coronal planes
In the current research, 68 specimens of orbital superior and/or medial walls taken from 33 human cadavers (12 females, 21 males) were subjected to uniaxial tension untill fracture. The samples were cut in the coronal (38 specimens) and sagittal (30 specimens) planes of the orbital wall. Apparent density (ρapp), tensile Young’s modulus (E-modulus) and ultimate tensile strength (UTS) were identified. Innovative test protocols were used to minimize artifacts and analyze the obtained data: (1) grips dedicated to non-symmetrical samples clamping were applied for mechanical testing, (2) non-contact measuring system of video-extensometer was employed for displacement registration, (3) ink imprint technique coupled with CAD analysis was applied to precisely access the cross-sectional areas of tested samples. With regard to a pooled group, apparent density for the coronal and sagittal cut plane was equal 1.53 g/cm3 and 1.57 g/cm3, tensile Young’s modulus 2.36 GPa and 2.14 GPa, and ultimate tensile strength 12.66 MPa and 14.35 MPa, respectively. No significant statistical differences (p > 0.05) were found for all the analyzed parameters when comparing coronal and sagittal plane cut groups. These observations confirmed the hypothesis that direction of sample cut does not affect the mechanical response of the orbital wall tissue, thus suggesting that mechanical properties of orbital wall bone show isotropic character.
- Open Access
- 4 March 2021
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2021, 1-12
Validation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
The more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanisms veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanisms theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model of the orbit were performed. The intraorbital hydraulic pressure was introduced as a face load applied directly to the orbit in the first variant, while in the second one the load was applied to the orbit indirectly as a set of nodal forces transferred from the external surface of the eyeball via the intraorbital tissues to the orbital walls within the contact problem. Such an approach is aimed at a better understanding of the pattern for the formation of blowout fractures during the indirect load applied to the orbital bones. The nonlinear dynamic analysis of both numerical models showed that the potential fracture was observed in the second variant only, embracing a relatively large area: both medial and lower wall of the orbit. Interestingly, the pressure generated by the intraorbital entities transferred the energy of the impact to the orbital sidewalls mainly; thus, the nature of the mechanism known as the hydraulic was far from the expected hydraulic pressure. According to the eyeballs deformation as well as the areas of the greatest Huber-Mises-Hencky (H-M-H) stress within the orbit, a new term of strut mechanism was proposed instead of the hydraulic mechanism as more realistic regarding the investigated phenomenon. The results of the current research may strongly influence the development of modern implantology as well as affect forensic medicine.
- 4 March 2021
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2021, 1-12
Open AccessValidation of Hydraulic Mechanism during Blowout Trauma of Human Orbit Depending on the Method of Load Application
The more we know about mechanisms of the human orbital blowout type of trauma, the better we will be able to prevent them in the future. As long as the buckling mechanisms veracity is not in doubt, the hydraulic mechanism is not based on equally strong premises. To investigate the correctness of the hydraulic mechanisms theory, two different methods of implementation of the hydraulic load to the finite element method (FEM) model of the orbit were performed. The intraorbital hydraulic pressure was introduced as a face load applied directly to the orbit in the first variant, while in the second one the load was applied to the orbit indirectly as a set of nodal forces transferred from the external surface of the eyeball via the intraorbital tissues to the orbital walls within the contact problem. Such an approach is aimed at a better understanding of the pattern for the formation of blowout fractures during the indirect load applied to the orbital bones. The nonlinear dynamic analysis of both numerical models showed that the potential fracture was observed in the second variant only, embracing a relatively large area: both medial and lower wall of the orbit. Interestingly, the pressure generated by the intraorbital entities transferred the energy of the impact to the orbital sidewalls mainly; thus, the nature of the mechanism known as the hydraulic was far from the expected hydraulic pressure. According to the eyeballs deformation as well as the areas of the greatest Huber-Mises-Hencky (H-M-H) stress within the orbit, a new term of strut mechanism was proposed instead of the hydraulic mechanism as more realistic regarding the investigated phenomenon. The results of the current research may strongly influence the development of modern implantology as well as affect forensic medicine.
- Open Access
- 24 June 2020
- Published by Institute of Rural Health in Journal of Pre-Clinical and Clinical Research
- Vol. 14 (2) , 39-43
Orbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
Introduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal...
- 24 June 2020
- Published by Institute of Rural Health in Journal of Pre-Clinical and Clinical Research
- Vol. 14 (2) , 39-43
Open AccessOrbital blowout trauma occurring at the workplace – clinical, biomechanical and legal aspects
Introduction and objective: Craniofacial injury at the workplace may lead to orbital blowout fractures. The aim of the study is the development of own numerical model of the eye orbit, assessment of the damage zones, and comparing them with clinical examinations. In addition, the current legal...
- 29 January 2020
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 155,p. e60737
Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Architectural fabric AF9032 has been subjected to artificial thermal ageing to determine changes of the material parameters of the fabric. The proposed method is based on the accelerated ageing approach proposed by Arrhenius. 300 mm x 50 mm samples were cut in the warp and fill directions and placed in a thermal chamber at 80 °C for up to 12 weeks or at 90 °C for up to 6 weeks. Then after one week of conditioning at ambient temperature, the samples were uniaxially tensioned at a constant strain rate. Experimentally, the parameters were determined for the non-linear elastic (linear piecewise) and viscoplastic (Bodner–Partom) models. Changes in these parameters were studied with respect to the ageing temperature and ageing period. In both cases, the linear approximation function was successfully applied using the simplified methodology of Arrhenius. A correlation was obtained for the fill direction between experimental results and the results from the Arrhenius approach. For the warp direction, the extrapolation results exhibited some differences. Increasing and decreasing tendencies have been observed at both temperatures. The Arrhenius law was confirmed by the experimental results only for the fill direction. The proposed method makes it possible to predict real fabric behavior during long term exploitation, which is a critical issue in the design process.
- 29 January 2020
- Published by MyJove Corporation in Journal of Visualized Experiments
- No. 155,p. e60737
Artificial Thermal Ageing of Polyester Reinforced and Polyvinyl Chloride Coated Technical Fabric
Architectural fabric AF9032 has been subjected to artificial thermal ageing to determine changes of the material parameters of the fabric. The proposed method is based on the accelerated ageing approach proposed by Arrhenius. 300 mm x 50 mm samples were cut in the warp and fill directions and placed in a thermal chamber at 80 °C for up to 12 weeks or at 90 °C for up to 6 weeks. Then after one week of conditioning at ambient temperature, the samples were uniaxially tensioned at a constant strain rate. Experimentally, the parameters were determined for the non-linear elastic (linear piecewise) and viscoplastic (Bodner–Partom) models. Changes in these parameters were studied with respect to the ageing temperature and ageing period. In both cases, the linear approximation function was successfully applied using the simplified methodology of Arrhenius. A correlation was obtained for the fill direction between experimental results and the results from the Arrhenius approach. For the warp direction, the extrapolation results exhibited some differences. Increasing and decreasing tendencies have been observed at both temperatures. The Arrhenius law was confirmed by the experimental results only for the fill direction. The proposed method makes it possible to predict real fabric behavior during long term exploitation, which is a critical issue in the design process.