Shinian Fu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Shinian Fu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Jianfei Tong
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
2 shared publications - Lingbo Zhu
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
2 shared publications - Longwei Mei
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
2 shared publications - Yiping Lu
Department of Mechanical and Power Engineering, Harbin University of Science and Technology, Harbin 150080, China
2 shared publications - Congju Yao
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication - Fei Shen
Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
1 shared publication
Latest Publications
- Open Access
Comparative Research on Ventilation Characteristics of Scattering and Sample Room from Chinese Spallation Neutron Source
Ventilation design of the scattering room and sample room in the Chinese Spallation Neutron Source (CSNS) is of great significance to maintain good indoor air quality and ensure the health of radiation workers. Based on the computational fluid dynamics (CFD) theory, the three-dimensional models of the scattering and sample rooms were established and fourteen layout schemes were simulated. Subsequently, the best schemes were selected among three typical layout schemes. On this basis, the paper presents research about the influence of changing the height of the outlet on the ventilation quality. The results show that the trend of numerical simulation is consistent with experimental data, which verifies the reliability of the numerical method. The change of the exhaust port position has an apparent influence on indoor ventilation, which reduces the air age by 4–27%. When the position of the outlet descends 0.5 m, the air age decreases by 2–11%, and this study provides guidance and suggestions for the design of the scattering and sample rooms.
Open AccessComparative Research on Ventilation Characteristics of Scattering and Sample Room from Chinese Spallation Neutron Source
Ventilation design of the scattering room and sample room in the Chinese Spallation Neutron Source (CSNS) is of great significance to maintain good indoor air quality and ensure the health of radiation workers. Based on the computational fluid dynamics (CFD) theory, the three-dimensional models of the scattering and sample rooms were established and fourteen layout schemes were simulated. Subsequently, the best schemes were selected among three typical layout schemes. On this basis, the paper presents research about the influence of changing the height of the outlet on the ventilation quality. The results show that the trend of numerical simulation is consistent with experimental data, which verifies the reliability of the numerical method. The change of the exhaust port position has an apparent influence on indoor ventilation, which reduces the air age by 4–27%. When the position of the outlet descends 0.5 m, the air age decreases by 2–11%, and this study provides guidance and suggestions for the design of the scattering and sample rooms.
- Open Access
Study on Convective Heat Transfer Characteristics of Supercritical Liquid Hydrogen in a U-Type Tube inside a Moderator
The flow and heat transfer characteristics of supercritical fluid in a U-tube have an important influence on the safe operation of a moderator, and the variation of gravity direction is suitable for special working conditions of the moderator. In this study, the three-dimensional turbulence flow and heat transfers of supercritical liquid hydrogen in a U-tube were investigated at an Re number ranging from 16,425 to 54,750 under constant heat flux (q = 80 kW/m2). The total length of the U-tube was 1725 mm, which had an entrance length L/D of 23, with the inner diameter and wall thickness of D × δ = 10 × 2 mm. The finite volume method was adopted, and the grid independence was verified by the grid convergence index (GCI). The calculation results of three turbulence models (SST k-w, RNG k-ε, Standard k-ε) were compared with the corresponding experimental data to obtain the turbulence model with the smallest error. The convective heat transfer characteristics with different values of heat flux (q = 30 kW/m2~100 kW/m2), mass flow (G = 3 g/s~10 g/s), and gravity (gx, gy, gz) were compared. Meanwhile, the heat transfer characteristics of supercritical liquid and conventional liquid hydrogen were compared. The results show that Nu increased from 5 g/s to 10 g/s by 56.6%, and mass flow rate had a greater impact on the variation of Nu; when gravity direction was consistent with the flow direction of liquid hydrogen (gx direction), the Nu number inside the channel was 4.21% and 5.56% higher than that in gy and gz direction, respectively. Supercritical liquid hydrogen has a stronger heat transfer ability than conventional liquid hydrogen, of which the Nu number is 16.7% higher. This study can provide useful guidance for the design of flow and heat transfer of supercritical liquid hydrogen in a U-tube and its application in moderators. Furthermore, it provides reference technical values for thermal safety and thermal management of the target station to ensure its safe and stable operation.
Open AccessStudy on Convective Heat Transfer Characteristics of Supercritical Liquid Hydrogen in a U-Type Tube inside a Moderator
The flow and heat transfer characteristics of supercritical fluid in a U-tube have an important influence on the safe operation of a moderator, and the variation of gravity direction is suitable for special working conditions of the moderator. In this study, the three-dimensional turbulence flow and heat transfers of supercritical liquid hydrogen in a U-tube were investigated at an Re number ranging from 16,425 to 54,750 under constant heat flux (q = 80 kW/m2). The total length of the U-tube was 1725 mm, which had an entrance length L/D of 23, with the inner diameter and wall thickness of D × δ = 10 × 2 mm. The finite volume method was adopted, and the grid independence was verified by the grid convergence index (GCI). The calculation results of three turbulence models (SST k-w, RNG k-ε, Standard k-ε) were compared with the corresponding experimental data to obtain the turbulence model with the smallest error. The convective heat transfer characteristics with different values of heat flux (q = 30 kW/m2~100 kW/m2), mass flow (G = 3 g/s~10 g/s), and gravity (gx, gy, gz) were compared. Meanwhile, the heat transfer characteristics of supercritical liquid and conventional liquid hydrogen were compared. The results show that Nu increased from 5 g/s to 10 g/s by 56.6%, and mass flow rate had a greater impact on the variation of Nu; when gravity direction was consistent with the flow direction of liquid hydrogen (gx direction), the Nu number inside the channel was 4.21% and 5.56% higher than that in gy and gz direction, respectively. Supercritical liquid hydrogen has a stronger heat transfer ability than conventional liquid hydrogen, of which the Nu number is 16.7% higher. This study can provide useful guidance for the design of flow and heat transfer of supercritical liquid hydrogen in a U-tube and its application in moderators. Furthermore, it provides reference technical values for thermal safety and thermal management of the target station to ensure its safe and stable operation.
- Open Access
- 19 December 2012
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 57 (36) , 4663-4667
Research progress on high intensity hadron accelerator in China
- 19 December 2012
- Published by Springer Nature in Chinese Science Bulletin
- Vol. 57 (36) , 4663-4667
Open AccessResearch progress on high intensity hadron accelerator in China